Advises That Schedule for Completing Work Re Essential Raw Cooling Water Pumphouse & Roadway Access Cells,Per Insp Repts 50-327/88-12 & 50-328/88-12 Acceptable
ML20248D990
Person / Time
Site: Sequoyah  
Issue date: 08/04/1989
From: Black S
Office of Nuclear Reactor Regulation
To: Kingsley O
TENNESSEE VALLEY AUTHORITY
References
TAC-R00488, TAC-R00489, TAC-R488, TAC-R489, NUDOCS 8908110189
Download: ML20248D990 (3)


Text

_

..

.

.

.[pua k

'..

.

n j

p UNITED STATES g.

g NUCLEAR REGULATORY COMMISSION

.

-4

4 WASHINGTON, O C. 20555

%,

/

,

  • ...+

August 4, 1989

Docket Nos. 50-327 and 50-328 i

l Mr. Oliver D. Kingsley, Jr.

I Senior Vice President, Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Mr. Kingsley:

l SUBJECT:

ESSENTIAL RAW COOLING WATER PUMPHOUSE FOUNDATION AND ROADWAY ACCESS CELLS (TAC - R00488/R00489)

In your letters. dated October 20 and December 28 1988, you provided the plan to close out Unresolved Items 88-12-05 and 88-12-09, on the essential raw cooling water pumphouse foundation and roadway access, in Inspection Report 50-327/50-328/88-12.

The inspection report was issued June 24, 1988.

This plan was accepted by the staff in its summary of the meeting of November 28, 1988. The summary of this meeting was issued on January 27, 1989.

In your letter dated July 10, 1989, you provided (1) the schedule for complet-ing work in the plan and (2) two refinements of the original plan. The schedule for the Tennessee Valley Authority (TVA) to start drilling the roadway access cells was July 2^, 1989. Completion of this drilling is expected approximately one month later.

The drilling would then start in Element D of the pumphouse foundation on approximately August 28, 1989. Completion of this drilling is expected by approximately October 16, 1989.

The two refinements of the original plan involve the definition of the grouting pressure to be used for the pumping station and the hole drilling depth into rock. A maximum grouting pressure has been established in the pumphouse foundation of 15 pounds per square inch at elevation 625.0 feet, the bottom of

.the intake liner.

This, you state, will ensure that grouting does not develop pressures exceeding the calculated allowable stress for the steel intake liner.

TVA will drill five feet into sound rock at each location to investigate the concrete / rock interface. You stated that coring five feet into sound rock will provide sufficient information for evaluating the interface to meet the plan re.; air %ents.

OFoi I i 8908110189 890804 PDR ADOCK C3000327 Q

PDC

,_

- _ _ _ - _ _ _

.

_

_

'

i

-

.

i

-.

..

e

'Mr. Oliver D. Kingsley, Jr.

-2-

,{

.

p,

)

,

We have reviewed the schedule for completing work in the plan and two refine-ments in the original plan. We conclude that'they both are acceptable. We may have an inspector visit the Sequoyah site to observe the drilling in the-roadway cells and/or the pumping station.

,.3

Sincerely, Original signed by Gerald E. Gears for Suzanne C. Black, Assistant Director for Projects TVA Projects Division Office of Nuclear Reactor Regulation cc: See next page Distribution Docket File NRC PDR Local PDR ADSP Reading D. Crutchfield B. D. Liaw S. Black R. Pierson B. Wilson L. Watson J. Brady M. Simms J. Donohew OGC J. Zwolinski E. Jordan ACRS(10)

GPA/CA SQN Rdg. File x(S)$

iVA: D/TPr

g.y:....pJ_jhg:.TVA-OFC :NRR:TVA/LA :NR

NRR:TVA/PM :TV :E3/BC/

7.............._.

...._:.....____.._:..

...:...........:

.

IRPieboS'

T n

'

NAME:MSimmsg...'J:J'

as :SB

,

rao p

__:.......

__:._.........:.................____..

.... :......

..:..

..........

...

DATE:8/3/89

B/2/89
8/4 / <
8/3 /89
8/'l/89
8/3 /89

\\

OFFICIAL RECORD COPY

._

_ _ _ _ _ _ __

__

t

.

.

-

-

..

Mr. Oliver D. Kingsley, Jr.

-2-cc:

General Counsel Mr. Kenneth M. Jenison Tennessee Valley Authority Senior Resident Inspector 400 West Summit Hill Drive Sequoyah Nuclear Plant ET llB 33H U.S. Nuclear Regulatory Commission Knoxville, Tennessee 37902 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 Mr. F. L. Moreadith Vice President, Nuclear Engineering Mr. Michael H. Mobley, Director Tennessee Valley Authority Division of Radiological Health 400 West Summit Hill Drive T.E.R.R.A. Building 6th Floor WT 12A 12A 150 9th Avenue North Knoxville, Tennessee 37902 Nashville, Tennessee 37219-5404 Dr. Mark 0. Medford Dr. Henry Myers, Science Advisor Vice President and Nuclear Committee on Interior Technical Director and Insular Affairs Tennessee Valley Authority U.S. House of Representatives 6N 38A Lookout Place Washington, D.C.

20515 Chattanooga, Tennessee 37402-2801 Tennessee Valley Authority Manager, Nuclear Licensing Rockville Office and Regulatory Affairs 11921 Rockville Pike Tennessee Valley *.uthority Suite 402 5N 157B Lookout Place Rockville, Maryland 20852 Chattanooga, Tennessee 37402-2801 Mr. John L. LaPoint Site Director Sequoyah Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Soddy Daisy, Tennessee 37379 j

Mr. M. Burzynski Acting Site Licensing Manager Sequoyah Nuclear Plant P. O. Box 2000 Soddy Daisy, Tennessee 37379 County Judge Hamilton County Courthouse Chattanooga, Tennessee 37402 Regional Administrator, Region II U.S. Nuclear Regulato*y Commission 101 Marietta Street, n.W.

Atlanta, Georgia 30323 i

_ ____.

. _ _..

-[