Text
e
%/
y e <-
IUA Tennessee Valley Authenty, Post Othce Box 2000. Soddy-Da:sy. Tennessee 37379 August 2, 1999 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D.C.
20555 Gentlemen:
In the Matter of
)
Docket No. 50-328 Tennessee Valley Authority
)
i SEQUOYAH NUCLEAR PLANT (SQN) - UNIT 2 CYCLE 9 12-MONTH STEAM GENERATOR (SG) INSPECTION REPORT AND 90-DAY REPORT FOR VOLTAGE-BASED ALTERNATE REPAIR CRITERIA In accordance with the requirements of SON Unit 2 Technical Specifications 4.4.5.5.b and TS 4.4.5.5.c, TVA is submitting the enclosed report that includes the following:
l (1) results of SG incervice inspections, j
(2) written follow-up information for a SG categorized as C-3, l
(3) results of voltage-based repair criteria for Cycle 10
(
operation.
I During the scheduled SON U2C9 refueling outage, extensive inservice inspections were conducted in all four SGs to address i
active and potential damage mechanisms identified in the Unit 2 Degradation Assessment.
The results of the inspections were classified as follows:
l l
SG 1 SG 2 SG 3 SG 4 Bobbin C-2 C-2 C-2 C-2 i
TTS RPC C-2 C-2 C-2 C-2 Freespan Dents C-1 C-1 C-1 C-1 U-Bend + Point C-2 C-3 C-1 C-1 (TTS - top of tubesheet, RPC - rotating pancake coil) 9900090125 990802
\\
PDR ADOCK 05000328 P
)
=-
9
-1.
.U.S.
Nuclear Regulatory Commission Page 2
~ August 2, 1999 The.results of voltage-based repair criteria for Cycle 10 operation are provided as an attachment to the enclosed report.
This-report is submitted to you in accordance with SON Unit 2
- License Condition 2.C. (8) (b).
The report was prepared by Westinghouse Electric Company.
TVA has reviewed the report and concurs with the results.
If you have any questions, please call me at (423) 843-7170 or Jim Smith at (423) 843-6672.
e alas Licensing and Industry Affairs Manager Enclosure cc (Enclosure):
Mr. R. W. Hernan, Project Manager U.S.
Nuclear. Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 NRC' Resident Inspector Sequoyah Nuclear Plant 2600 Igou Ferry Road Soddy-Daisy, Tennessee 37379-3624 Regional Administrator U.S. Nuclear Regulatory Commission Region II Atlanta Federal Reserve 61.Forsyth St.,
SW, Suite 23T85 Atlanta, Georgia 30303-3415 l
.)
'