TA Tennessee Valley Authonty. Post Offce Box 2000. Soddy-Daisy Tennessee 37379 August 16, 1999 10 CFR 2.790 U.S. Nuclear Regulatory Commission y
ATTN:
Document Control Desk Washington, D.C.
20555 1
Gentlemen:
In the Matter of
)
Docket Nos.
50-327 Tennessee Valley Authority
)
50-328 SEQUOYAH NUCLEAR PLANT (SON) - WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT Enclosed are copies of the proprietary and non-proprietary versions of the Westinghouse Topical Report (WCAP 15128) for your review.
This report is provided to you in advance of a SON technical specification (TS) change that is being prepared by TVA to support the SON Unit 1 Cycle 10 refueling outage (currently scheduled to begin in February 2000).
This Topical Report contains analysis for an alternate repair criteria for primary water stress corrosion cracking at dented tube support plates.
The analysis provides eddy current techniques, criteria to detect and size tube indications, and alternate repair criteria methodology for this damage mechanism.
The Topical Report is generic in nature and is currently planned to be utilized by both SON and Diablo Canyon.
As such, TVA and Pacific Gas and Electric (PG&E) are requesting
{ fC(
that the billable manhours be addressed in accordance with NRC's processes for generic review. provides the application for withholding and l
affidavit (CAW-99-1351) signed by Westinghouse, the owner of k
j the information, as well as the proprietary information jl notice and copyright notice.
The application for withholding j
and the affidavit set forth the basis on which the information may be with held from public disclosure by NRC and address the considerations listed in Paragraph (b) (4 ),
l Section 2.790 of NRC regulations.
( hbw LTR e i4 c t v
.., n n PDR ADOCK 05000327 I
1 0908230213 990016
\\% b I
gO {4J I
f j
PDR i
L Og
'P
F r..
.9
\\l i
U.S. Nuclear. Regulatory. Commission Page 2 August}16, 1999
- Accordingly,.itiis respectfully requested that the information that.is proprietary to Westinghouse be withheld D
Lfrom public disclosure in accordance with 10 CFR, 1Section 2.790.
' Enclosure 2;provides the proprietary. version of WCAP 15128.
, Jprovides the non-proprietary. version.
Correspondence,' with respect to the copyright _or proprietary aspects-of the subject report or the supporting Westinghouse affidavit, should reference. CAW-99-1351' and should be addressed to:
John'S. Galembush-Regulatory and Licensing Engineering-Westinghouse Electric. Company Box 355-Pittsburgh, Pennsylvania 15230-0355 If-you have'any: questions, please call.me at (423) 843-7170 or
, Jim Smith at ' (423)' 843-6672.
L Ne las
. Licensing and-Industry Affairs Manager i Enclosures cc (Enclosures):
'Mr. R. ii. Hernan, Project Manager
.U.S.
Nuclear Regulatory-Commission One White 1 Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 NRC. Resident Inspector (w/o Enclosures)
L
.Sequoyah Nuclear Plant 2600 Igou Ferry Road Soddy-Daisy,. Tennessee 37379-3624
-Regional Administrator-(w/o Enclosures)
EU.S. Nuclear Regulatory Commission 1 Region II 1 Atlanta-Federal Reserve 61 Forsyth St.,
SW, Suite 23T85
- Atlanta ~LGeorgia'30303-3415' p-n b
rc
)
I 1
i ENCLOSURE 1 WESTINGilOUSE ELECTRIC COMPANY SEQUOYAH NUCLEAR PLANT (SON) UNITS 1 AND 2 DOCKET NOS. 50-327 AND 50-328 1
APPLICATION FOR WITHHOLDING AND AFFIDAVIT i
i (CAW-99-1351) j l
l l