Forwards Staff Evaluation Re Response to Oct 1984 Assessment Rept,Nus Mgt Audit & Systematic Evaluation of Licensee Performance Rept for 1984.Info Should Be Provided in Third Quarterly Status Rept on Performance Enhancement Program
ML20133D467
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 10/03/1985
From: Hunter D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Lee O
PUBLIC SERVICE CO. OF COLORADO
Shared Package
ML20133D471 List:
References
TAC-60566, NUDOCS 8510090070
Download: ML20133D467 (2)


Text

-

' Docket: 267 OCT 0 31985 Public Service Company of Colorado ATTN: 0. R. Lee, Vice President Electric Production P. O. Box 84C Denver, Colorado 80201-0840 Gentlemen:

=We have reviewed-your various submittals which respond to our October 1984

-Assessment Report, the NUS Management Audit and our Systematic Evaluation of

' Licensee Performance Report for 1984. The results of our review are contained o-in -the enclosed staff evaluation.

We have found that'your submittals are responsive to these reports and that your Performance Enhancement Program should materiallJ strengthen the can' duct

~

of operations at the Fort St. Vrain Station. However, as discussed in the-enclosed evaluation, there are some findings and recomendations which we require additional information. We request-that you review the enclosure and provide;the information requested therein as a part'of the third quarterly status report on the Performance Enhancement Program, which is due in-the December 1985 timeframe.

If you have any questions on this subject, please contact the NRC Project Manager.

". ~ Since this reporting requirement relates solely to Fort St.;Vrain, 0MB ,

. clearance is not required under P.L.96-511.

Sincerely,

'? Original Signed By:

D.R. HUNTER" Dorwin~R. Hunter, Chief Reactor Safety Branch

Enclosure:

- Staff Evaluation -

cc: .(See next page)

.RIV:RSB/ES ES -RS PCWagner:gb REIr[ eland DRHtTnter

  • ) /$0/85 /0/3/85- io/g/85

!GA e

E8E M%!n7 Bdf.}(

j Public Service. Company of Colorado -cc: .

Mr. D. W. Warembourg, Manager Nuclear Engineering Division Public Service Company of Colorado P._0. Box 840

. Denver, Colorado 80201 Mr. David Alberstein, 14/159A GA Technologies, Inc.

~

P. O. Box'85608

. San.Diego, California 92138

Kelley, Stansfield & 0'Donnell l Public Service Company-Bullding '
550 15th. Street, Room 900  ;

Denver,' Colorado 80202 '

Chairman, Board of County Comm.

of Weld County, Colorado

- Greeley, Colorado 80631 Regional Representative

. Radiation Programs Environmental Protection Agency 1860 Lincoln Street.

Denver, Colorado 80203 Mr. H. L. Brey, Manager q Nuclear Licensing / Fuels Div.

J 'Public Service Company of Colorado- _

.P. O. Box:840 i .l' . Denver,' Colorado 80201 J. W. Gahm, Manager, Nuclear.,

f Production Division Fort St.'Vrain Nuclear Statitn c 16805 WCR'191 Platteville, Colorado 80651 o

b L. Singleton,' Manager, Quality Assurance Division ' '

[ (same address)

Colorado Radiation Control Program Director-bec distrib. by -RIV:

RPB- Resident Inspector R. D. Martin, RA RSB' Section Chief, RSB/ES EP&RPB P.-Wagner,RSB/ES R. Denise, DRSP E. Haycraft, DRSP/LA RIV Official. Reading File E. Butcher, ORB 3 CPB/NRR D.' Eisenhut D/DL~ G. Lainas, DL K. Heitner, ORB 3 J. Taylor, IE E. Jordan, IE L. Crocker, DAFS/NRR D. Becham, DHFS/NRR P. Tremblay, ORAB/NRR

. _ . . .