ML20137T137: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 27: Line 27:
==SUBJECT:==
==SUBJECT:==
INJECTION AP PENALTY FOR ECCS EVALUATION MODEL Re:            Yankee Nuclear Power Station (Yankee)
INJECTION AP PENALTY FOR ECCS EVALUATION MODEL Re:            Yankee Nuclear Power Station (Yankee)
In a letter dated August 16, 1985, Yankee Atomic Electric Company proposed a modification to their ECCS evaluation model used for. Yankee. The model modification proposes to reduce the injection AP penalty, which accounts for the thermal-hydraulic interaction between steam and the emergency core cooling water, from 0.8 psid to 0.15 psid during the pumped ECCS injection phase.
In a {{letter dated|date=August 16, 1985|text=letter dated August 16, 1985}}, Yankee Atomic Electric Company proposed a modification to their ECCS evaluation model used for. Yankee. The model modification proposes to reduce the injection AP penalty, which accounts for the thermal-hydraulic interaction between steam and the emergency core cooling water, from 0.8 psid to 0.15 psid during the pumped ECCS injection phase.
Enclosed is our safety evaluation on this model modification. Based upon            ,
Enclosed is our safety evaluation on this model modification. Based upon            ,
the EPRI ECC mixing data and independent staff calculations, we have concluded that the proposed modific.ation complies with Section I.D.4 of            1 Appendix K to 10 CFR 50. Thus, we find this model modification acceptable as part of the approved Yankee Atomic ECCS evaluation model for Yankee.
the EPRI ECC mixing data and independent staff calculations, we have concluded that the proposed modific.ation complies with Section I.D.4 of            1 Appendix K to 10 CFR 50. Thus, we find this model modification acceptable as part of the approved Yankee Atomic ECCS evaluation model for Yankee.

Latest revision as of 08:20, 13 December 2021

Forwards Safety Evaluation Supporting Mod to ECCS Evaluation Model to Reduce Injection Delta P Penalty.Model Mod Acceptable as Part of Approved ECCS Evaluation Model
ML20137T137
Person / Time
Site: Yankee Rowe
Issue date: 11/27/1985
From: Lear G
Office of Nuclear Reactor Regulation
To: Papanic G
YANKEE ATOMIC ELECTRIC CO.
Shared Package
ML20137T143 List:
References
NUDOCS 8512060396
Download: ML20137T137 (2)


Text

. - - - _ - _ - . - _ _ _ _ - _- - . - .

NOV 271915

/, Docket No. 50-29

'f a j Mr. George Papanic, Jr.

Senior Project Engineer - Licensing Yankee Atomic Electric Company 1671 Worcester Road Framingham, Massachusetts 01701

Dear Mr. Papanic:

SUBJECT:

INJECTION AP PENALTY FOR ECCS EVALUATION MODEL Re: Yankee Nuclear Power Station (Yankee)

In a letter dated August 16, 1985, Yankee Atomic Electric Company proposed a modification to their ECCS evaluation model used for. Yankee. The model modification proposes to reduce the injection AP penalty, which accounts for the thermal-hydraulic interaction between steam and the emergency core cooling water, from 0.8 psid to 0.15 psid during the pumped ECCS injection phase.

Enclosed is our safety evaluation on this model modification. Based upon ,

the EPRI ECC mixing data and independent staff calculations, we have concluded that the proposed modific.ation complies with Section I.D.4 of 1 Appendix K to 10 CFR 50. Thus, we find this model modification acceptable as part of the approved Yankee Atomic ECCS evaluation model for Yankee.

Sincerely, George E. Lear, Director PWR Project Directorate #1 Division of PWR Licensing-A '

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page DISTRIBUTION QesteW H W - EJordan NRC PDR BGrimes Local PDR JPartlow PWR#1 Rdg JClifford '

HThompson PShuttleworth OELD ACRS (10)

RJones Glear DBL:PD#1['t DPL: M1 DPL: PWR#1 CJamersoK JClifford: tm GLear ll />f,/85 ll /3&85 j(/p/85 0512060396 851127 PDR ADOCK 05000029 P PDR

V i

i i l i

s i

i Mr. George Papanic, Jr.

4 Yankee Atomic Electric Company Yankee Nuclear Power Station ,

i cc:

i Mr. James E. Tribble, President i Yankee Atomic Electric Company

1671 Worcester Road Framingham, Massachusetts 01701  ;

1 Thomas Dignan Esquire Ropes and Gray [

i ,

l 225 Franklin Street Boston, Massachusetts 02110

! Mr. N. N. St. Laurent i Plant Superintendent j Yankee Atomic Electric Company i Star Route Rowe, Massachusetts 01367 i

Chairman 1

l Board of Selectmen l Town of Rowe i

Rowe, Massachusetts 01367 t

Resident inspector ,

i Yankee Nuclear Power Station

! c/o U.S. NRC t

! Post Office Box 28 l Monroe Bridge, Massachusetts 01350

Regional Administrator, Region I *
U.S. Nuclear Regulatory Commission

, 631 Park Avenue i King of Prussia, Pennsylvania 19406 Robert M. Hallisey, Director l Radiation Control Program 4

j Massachusetts Department of Public Health .

j 150 Tremont Street, 7th Floor Boston, Massachusetts 02111 t

l t

_ - _ - _ _ - - - - - - --