IR 05000400/1986088: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 2: Line 2:
| number = ML20207T792
| number = ML20207T792
| issue date = 02/24/1987
| issue date = 02/24/1987
| title = Ack Receipt of 870206 Ltr Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-400/86-88
| title = Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-400/86-88
| author name = Reyes L
| author name = Reyes L
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Line 11: Line 11:
| contact person =  
| contact person =  
| document report number = NUDOCS 8703240346
| document report number = NUDOCS 8703240346
| title reference date = 02-06-1987
| document type = CORRESPONDENCE-LETTERS, NRC TO UTILITY, OUTGOING CORRESPONDENCE
| document type = CORRESPONDENCE-LETTERS, NRC TO UTILITY, OUTGOING CORRESPONDENCE
| page count = 1
| page count = 1

Latest revision as of 12:53, 5 December 2021

Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-400/86-88
ML20207T792
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 02/24/1987
From: Reyes L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Utley E
CAROLINA POWER & LIGHT CO.
References
NUDOCS 8703240346
Download: ML20207T792 (1)


Text

l-FEB 2 41987 Docket No. 50-400 License No. NPF-63

,Cyolina Power and Light Company WITN: Mr. E. E. Utley Senior Executive Vice President Power Supply and Engineering and Construction P. O. Box 1551 Raleigh, NC 27602 Gentlemen:

SUBJECT: NRC INSPECTION REPORT N0. 50-400/86-88 Thank you for your response of February 6,1987, to our Notice of Violation issued on January 8,1987, concerning activities conducted at your Harris facility under NRC License No. NPF-6 We have evaluated your response and found that it meets the requirements of 10 CFR 2.201. We will examine the implementation of your corrective actions during future inspection We appreciate your cooperation in this matte

Sincerely, Original Signed by Luis A. Reyes Luis A. Reyes, Director Division of Reactor Projects cc: t,R'. A. Watson, Vice President Harris Nuclear Project tF' L. Tibbitts, Director of

)tegulatory Compliance W. L. Willis, Plant General Manager bec: Barth, 0GC d. Moore, 0GC kNRC Resident Inspector Document Control Desk State of North Carolina MDHunt:ht ATa l~

j f 2/#ylor TEConlon h

ARHerdt VWRanciera th Fredrickson h f h//3/87 P /87 2/g/87 2/q/87 2/h/87 2/f i/87 8703240346 870224 PDR ADOCK 05000400 0 PDR Z.E of