Letter Sequence Other |
|---|
CAC:001028, ECCS Response Time Testing (Approved, Closed) EPID:L-2021-LLA-0053, Attachment 2: Updated Summary of Proposed Changes (non-proprietary) (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML17318A087, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI 2018-01-10
[Table View] |
Text
Page 1 of 4 Holtec Response to Request for Additional Information (Part 2)
Docket No. 72-1032 Holtec International HI-STORM FW Multipurpose Canister Storage System Certificate of Compliance No. 1032 Amendment No. 7 RAI 3-1 Provide descriptions of the evaluations of the Version unventilated high density (UVH) cask in chapter 3.I of the safety analysis report (SAR). These descriptions should include the methodologies and acceptance criteria used in the evaluations as well as the results and discussions of those results that supports the stated conclusions. Specifically include the following evaluations:
a) The evaluation of the MPC containment boundary in the Version UVH cask, b) The evaluation of Version UVH cask under internal and external pressure loads mentioned in section 3.I.3.2 of the SAR, c) The evaluation of Version UVH closure lid under lifting and snow load conditions mentioned in section 3.I.3.3 of the SAR, d) The evaluations of Version UVH casks stability in the event of flood, explosion, and earthquake mentioned in sections 3.I.3.4 through 3.I.3.6 of the SAR, e) The evaluation of Version UVH cask in the event of tornado (wind and missile impacts) mentioned in section 3.I.3.7 of the SAR, and f) The evaluation of Version UVH cask in the event of non-mechanistic tip-over mentioned in section 3.I.3.8 of the SAR.
In accordance with 10 CFR 72.230(a), the applicant for a CoC must submit a SAR describing the proposed cask design and how the cask should be used to store spent fuel safely. However, the description of the design of the Version UVH cask in the SAR, specifically for the structural evaluations listed above, merely refences other reports in lieu of describing the methodology, acceptance criteria, results, and discussion for the structural evaluations. For example, the description of the tornado missile penetration analysis in SAR section 3.I.3.7 is a single sentence, The penetration analysis for Version UVH cask using the wind and missile characteristics defined in Tables 2.2.4 and 2.2.5 is presented in Appendix J of [3.4.15]
demonstrating all results are acceptable. This statement does not describe the penetration analysis; it references other tables and reports. The staff requests descriptions of the structural evaluations of Version UVH cask be added to the HI-STORM FW SAR that include the methodologies used in the evaluations, the acceptance criteria considered for the evaluations, the results of the analyses, discussions of those results that support the conclusions, and the conclusions of the evaluations.
This information is needed to determine compliance with the regulatory requirements in 10 CFR 72.230(a) and 10 CFR 72.236(l).
Holtec RAI Response:
Holtec understands Staffs concerns regarding the presentation of analysis material in Chapter 3.I of the SAR.
Therefore, additional discussion related to methodology, acceptance criteria and results is added for all evaluations in Section 3.I.3. However, in certain cases where the methodology and acceptance criteria are same as those presented in the main Chapter 3 for specific evaluations, references to those sections or Holtec Letter 5018096 Attachment 1
Page 2 of 4 paragraphs in Chapter 3 are made.
For example, the MPC confinement boundary evaluation is performed using the same analysis model, methodology and acceptance criteria described in Section 3.4 of Chapter 3 as the MPCs are not different in the HI-STORM UVH system, and only the input pressure and temperatures are varied based on the pressure limits in Table 2.2.1 and the thermal analysis results of HI-STORM UVH system presented in Chapter 4.I, respectively. Therefore, references to Paragraphs 3.1.3.2 and 3.4.3.2, and Subparagraph 3.4.4.1.5 are made in Subsection 3.I.3.1 along with the presentation of results for the two new analyses under normal and off-normal conditions to respond to Staffs request. The analyses under design, handling, short-term normal and accident conditions are bounded by those presented in Section 3.4 of Chapter 3 for the MPC confinement boundary.
Similarly, references to the main chapter section/paragraph are made in the discussion of other evaluations, where applicable, to avoid repetition of information.
RAI 3-2 Provide full versions of the following reports: (1) Holtec proprietary report HI-2094418, Structural Calculation Package for HI-STORM FW System, revision 37 and (2) Holtec proprietary report HI-2094392, Tornado Missile Analysis for HI-STORM FW System, revision 13.
The applicant submitted change pages of the three documents requested to assist the staff in the review.
However, some of the changes in this amendment rely on or reference information in sections of these documents that were not included in the change pages versions. For example, table 2.I.2.1 of the SAR states, the lifting analysis of Version E cask using bounding lifted weight in Table 3.2.8 remains applicable for Version UVH cask. To verify this statement, the staff needs to review the lifting analysis of the Version E cask, which was not included in the change pages versions of HI-2094418.
This information is needed to determine compliance with the regulatory requirements in 10 CFR 72.236(l).
Holtec RAI Response:
Holtec understands Staffs concerns and therefore, the complete reports, HI-2094418R37 and HI-2094392R13, are provided with this RAI response.
RAI 3-3 Clarify the editorial changes with regard to handling and short-term operations made in sections 2.2.3 and 9.1 of the SAR. Specifically, address the followings:
a) Discuss the intent of the editorial changes, including which regulatory requirements, if any, these statements are addressing, and explain the view that the changes are merely editorial.
In the Summary of Proposed Changes for this amendment, the applicant listed these changes in the last two bullets under editorial changes. However, it appears to the staff that the applicant may be defining new methods of evaluation for loadings, operations, and equipment. If these changes are intended to define new methods of evaluation, they would be considered technical changes, not editorial changes. NRC Regulatory Information Summary 2017-05, Administration of 10 CFR Part 72 Certificate of Compliance Corrections and Revisions, and section 4.3 of NEI 12-04, Guidelines for 10CFR 72.48 Implementation, provide guidance on editorial changes.
The staff requests clarification on the intent of these editorial changes and the reasoning for listing them as editorial.
b) Describe in the SAR the methods of evaluation and acceptance criteria for the analyses of the loadings, handling operations, and equipment used for the safety analysis mentioned in section 2.2.3 of the SAR and for the reports referenced in section 9.1.
Holtec Letter 5018096 Attachment 1
Page 3 of 4 The changes in sections 2.2.3 and 9.1 of the SAR state that the method of analysis shall follow prior established precedent and a series of generic reports [9.1.4 thru 9.1.7] that address various loading scenarios have been adopted in Holtecs configuration control system. The staff requests the applicant supplement these statements to describe in the SAR the methodologies and acceptance criteria used in these analyses.
c) Clarify the statement in section 2.2.3 of the SAR, To perform the site-specific safety analysis of the handling evolutions, the magnitude of the incident load should be informed by its frequency of likely occurrence and the mitigative measures employed.
It appears to the staff that this statement is introducing a new method of evaluation for analyzing handling operations that includes considerations of the likelihood of certain loads and potential mitigative measures. Clarify the followings: (1) what was the intent of this statement; (2) what loads does this statement apply to; (3) how are these likelihoods and mitigative measures determined; (4) how are the likelihood and mitigative measures considered in or affect these site-specific safety analyses; and (5) what regulatory requirement, if any, does this statement address.
d) Define the terms short-term operations and transitional transitory steps as they are used in the statement from section 2.2.3 of the SAR, All short-term operations, except the transitional transitory steps (such as upending or down-ending of the cask, placement of the Closure Lid on HI-STORM),
shall be subject to safety analysis under the postulated environmental loads.
e) Justify the exception of transitional transitory steps to the conditions that require safety analysis, as stated in section 2.2.3 of the SAR.
In accordance with 10 CFR 72.236(l), an applicant for a CoC shall evaluate the Important to Safety (ITS) Systems, Structures, and Components (SSCs) under normal, off-normal, and credible accident conditions, and the definition of ITS SSCs in 10 CFR 72.3 includes features that prevent damage to the spent fuel during handling. Given these regulatory requirements, its not clear to the staff what transitional transitory steps are or why they do not require safety analysis.
f) Describe in the SAR the method of evaluation and acceptance criteria for the probabilistic risk assessment (PRA) discussed in the statement from section 2.2.3 of the SAR, With respect to short-term operations in dry storage campaigns, a [PRA] may be employed at a geologically stable and low return frequency site, characterized by a small number of annual loadings, to evaluate the risk associated with a simultaneous earthquake event. Additionally, clarify: (1) how this PRA would be considered in or affect the safety evaluation of operations; (2) which operations would be affected; (3) how the PRA would be used to address regulatory requirements, if any; (4) which regulatory requirements would the PRA address; (5) the definitions of geologically stable and low return frequency site; and (6) the justification for those definitions.
It appears to the staff that the quoted sentence from SAR section 2.2.3 is attempting to establish a new method of evaluating operations using a risk assessment, however, the applicant has not provided any information on this analysis.
g) Describe in the SAR the methods of evaluation and acceptance criteria for the sliding analysis mentioned in the statement from section 2.2.3 of the SAR, Safety against potential sliding of the assemblage leading to an impact with a safety significant structure proximate to the haul path shall also be ascertained.
h) Justify the statement in section 9.1 of the SAR that characterizes loading configurations and ancillary equipment as being outside of the scope of the final safety analysis report (FSAR). Additionally, clarify which loading configurations and ancillary equipment are being discussed in the editorial change in section 9.1 of the SAR and which regulatory requirements this editorial change is addressing, if any.
In section 9.1 of the SAR, the applicant stated, The safety evaluation of the various loading Holtec Letter 5018096 Attachment 1
Page 4 of 4 configurations and ancillaries is outside the scope of this FSAR because such equipment and analyses must, of necessity, be site specific to accord with the exigencies of the architecture of each plant. Its not clear to the staff which loading configurations and ancillary equipment the applicant is referring to. The staff notes that 10 CFR 72.236(l) requires an applicant for a CoC to evaluate the ITS SSCs under normal, off-normal, and credible accident conditions and the definition of ITS SSCs in 10 CFR 72.3 includes features that prevent damage to the spent fuel during handling. Given these regulatory requirements, its not clear to the staff why the applicant considers the safety evaluation of certain loading configurations and equipment outside the scope of this FSAR. The staff recognizes the site-specific nature of handling operations at individual independent spent fuel storage installations, but its not clear to the staff how the presence of site-specific characteristics preclude the applicant from meeting the regulatory requirements applicable to CoC holders in 10 CFR Part
- 72.
This information is needed to determine compliance with the regulatory requirements in 10 CFR 72.230(a) and 10 CFR 72.236(l).
Holtec RAI Response:
The changes in FSAR Sections 2.2.3 and 9.1 were intended to clarify the approach to various short-term operations, in light of some of the on-going industry discussions around this topic. However, since the submittal of this amendment, there have been further industry wide discussions with NRC staff, and issuance of an Enforcement Guidance Memorandum. Additionally, there has been submittal of a guidance document for potential NRC endorsement. Therefore, to avoid inconsistency between this FSAR and other industry activities, these proposed FSAR changes have been removed from this application.
Holtec Letter 5018096 Attachment 1