Letter Sequence RAI |
---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance
- Supplement
Results
Other: ML22122A200, ML22273A141, ML22297A126, ML24031A564, ML24095A041, ML24095A044, ML24095A045, ML24095A046, ML24240A118, ML24240A119, ML24240A120, ML24240A121, ML24240A122, ML24240A124, ML24240A125, ML24240A126
|
MONTHYEARML21349B4182021-12-15015 December 2021 International, Submittal of HI-STORM 100 Request for Amendment 18 Project stage: Request ML21349B4192021-12-15015 December 2021 International, Submittal of HI-STORM 100 Request for Amendment 18 Project stage: Request ML22038A9402022-02-0707 February 2022 International, Submittal of RAI Responses on the Topical Report on Methodology for Fuel Qualification Project stage: Request ML22122A1992022-06-22022 June 2022 Acceptance Review of Holtec Intl HI-STORM 100 Application for Certificate of Compliance No. 1014, Amendment No. 18 - Request for Supplemental Information Project stage: Acceptance Review ML22122A1982022-06-22022 June 2022, 23 June 2022 CoC 1014 Amendment No.18 Project stage: Request ML22122A2002022-06-23023 June 2022 Enclosure - Request for Supplemental Information - Rsi Project stage: Other ML22207B7832022-07-0606 July 2022, 7 July 2022, 1 August 2022 HI-STORM 100 Amendment No. 18 - Rsi Clarifications Meeting Summary Project stage: Request ML22187A2702022-07-0606 July 2022 International, HI-STORM 100 Amendment 18 Rsi Clarification Meeting Project stage: Request ML22207B7842022-08-0101 August 2022 Memo Meeting Summary for CoC No. 1014, Amendment No. 18 - Rsi Clarifications Project stage: Meeting ML22245A1042022-09-0202 September 2022 International, HI-STORM 100 Amendment 18 Responses to Requests for Supplemental Information Project stage: Supplement ML22245A1032022-09-0202 September 2022 International, HI-STORM 100 Amendment 18 Responses to Requests for Supplemental Information Project stage: Request ML22297A1242022-09-28028 September 2022, 31 October 2022 Meeting Summary for Shielding Topical Report - Clarification of Holtec RAI Responses Project stage: Request ML22273A1412022-10-13013 October 2022 CoC 1014 Amendment 18 - Acceptance Determination Letter Project stage: Other ML22297A1252022-10-31031 October 2022 Enclosure 1 - Summary of RAI Discussion Between NRC and Holtec Staff Project stage: RAI ML22297A1272022-10-31031 October 2022 Summary of Meeting with Holtec International to Discuss Clarification of Holtecs Responses to Request for Additional Information for the Shielding Topical Report Project stage: RAI ML22297A1262022-10-31031 October 2022 Enclosure 2 - List of Attendees Project stage: Other ML23058A1262023-03-0606 March 2023 CoC No.1014 Amendment 18 Project stage: Request ML23058A1272023-03-0606 March 2023 CoC No.1014 Amendment 18 - Enclosure RAI (Public) Project stage: RAI ML23058A1282023-03-0606 March 2023 CoC No.1014 Amendment 18 - RAI Letter (Public) Project stage: RAI ML23146A1382023-05-26026 May 2023 International - Submittal of RAI Responses on HI-STORM 100 Amendment 18 Project stage: Request ML23215A0592023-08-0202 August 2023 Conversation Record Between Holtec and NRC - Clarification Call 08-02-2023 HI-STORM 100 A18 RAIs Project stage: Request ML23283A1242023-11-0202 November 2023 Enclosure 1 (Public) - HI-STORM 100 Amd 18 - 2nd RAI Round Project stage: RAI ML23283A1262023-11-0202 November 2023 Letter - Second Request for Additional Information - HI-STORM 100 Amd 18 Project stage: RAI ML24018A1982024-01-18018 January 2024 International, Administrative Change to HI-2200343-A Project stage: Request ML24031A5622024-01-24024 January 2024 Enclosure 1 -(Public) - Second Round Requests for Additional Information Clarifications Project stage: RAI ML24031A5642024-01-24024 January 2024 Conversation Record Between Holtec and the U.S. Nuclear Regulatory Commission Holtecs Responses to HI-STORM 100 Amendment No. 18 Project stage: Other ML24046A2542024-02-15015 February 2024 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 Project stage: Request ML24095A0412024-08-22022 August 2024 1 Proposed Certificate of Compliance No. 1014, Renewed Amendment 18 Project stage: Other ML24095A0452024-08-22022 August 2024 5 Proposed TS, Appendix D, Certificate of Compliance No. 1014, Renewed Amendment 18 Project stage: Other ML24095A0442024-08-22022 August 2024 4 Proposed TS, Appendix C, Certificate of Compliance No. 1014, Renewed Amendment 18 Project stage: Other ML24095A0462024-08-22022 August 2024 6 Proposed TS, Appendix A-100U, Certificate of Compliance No. 1014, Renewed Amendment 18 Project stage: Other ML24240A1192024-10-0808 October 2024 1 Certificate of Compliance 1014 A18 Final Certificate of Compliance Project stage: Other ML24240A1262024-10-0808 October 2024 7 Certificate of Compliance 1014 A18 Final Appendix B-100U Project stage: Other ML24240A1252024-10-0808 October 2024 6 Certificate of Compliance 1014 A18 Final Appendix A-100U Project stage: Other ML24240A1212024-10-0808 October 2024 3 Certificate of Compliance 1014 A18 Final Appendix B Project stage: Other ML24240A1202024-10-0808 October 2024 2 Certificate of Compliance 1014 A18 Final Appendix a Project stage: Other ML24240A1242024-10-0808 October 2024 5 Certificate of Compliance 1014 A18 Final Appendix D Project stage: Other ML24240A1272024-10-0808 October 2024 8 HI-STORM 100 Amendment 18 - Final Safety Evaluation Report Project stage: Approval ML24240A1222024-10-0808 October 2024 4 Certificate of Compliance 1014 A18 Final Appendix C Project stage: Other ML24240A1182024-10-0808 October 2024 0 Issuance Letter Amendment 18 to Renewed Certificate of Compliance No. 1014 for the HI-STORM 100 Cask System Project stage: Other 2022-09-28
[Table View] |
|
---|
Category:Meeting Summary
MONTHYEARML24192A1662024-07-23023 July 2024 Summary of June 17, 2024 Pre-application Meeting for Amendment No. 19 to the HI-STORM 100 System ML24066A1602024-03-0808 March 2024 Enclosure 1 - Summary of February 8, 2024 Public Meeting with Holtec and Hug: Attendee List ML24066A1632024-03-0808 March 2024 Memorandum - Summary of February 8, 2024 Public Meeting with Holtec International and Holtec Users Group on EA 23-044 and Path Forward ML24067A3022024-03-0808 March 2024 Memorandum: Summary of March 6, 2024, Public Meeting with Holtec International Inc. and the Holtec Users Group to Discuss the Path Forward for General Licensees Affected by the Continuous Basket Shims Basket Design Change ML23313A1172023-11-21021 November 2023 October 26, 2023 Summary of Holtec International Pre-decisional Enforcement Conference ML23097A1162023-04-0505 April 2023 Enclosusummary of Discussion 04-05-2023 ML23058A1232023-02-22022 February 2023 Enclosusummary of Phone Call with Holtec International (Holtec) on 02-22-2023 Shielding Topical Report ML22297A1272022-10-31031 October 2022 Summary of Meeting with Holtec International to Discuss Clarification of Holtecs Responses to Request for Additional Information for the Shielding Topical Report ML22297A1252022-10-31031 October 2022 Enclosure 1 - Summary of RAI Discussion Between NRC and Holtec Staff ML22207B7842022-08-0101 August 2022 Memo Meeting Summary for CoC No. 1014, Amendment No. 18 - Rsi Clarifications ML21326A0812021-11-30030 November 2021 November 10, 2021, Summary of Public Meeting with Holtec International to Discuss Pre-Application of Certificate of Compliance No. 1014, Amendment No. 18 ML21237A0432021-08-25025 August 2021 Summary of July 27, 2021, Public Meeting with Holtec International to Discuss Certificate of Compliance No. 1014 for the HI-STORM 100, Amendment No. 16, Graded Approach ML21082A0852021-04-0909 April 2021 Summary of Closed Meeting with Holtec International and U.S. Nuclear Regulatory Commission Regarding Topical Report for Allowance of Heat Load Patterns in Hi-Storm 100 and Hi-Storm FW Systems ML20064F6162020-02-29029 February 2020 January 15, 2020, Summary of Meeting with Holtec International, Inc., to Discuss the Upcoming Submittal of the Application for Renewal of the Storage Certificate of Compliance No. 1014 for the HI-Storm 100 Cask System ML19241A2762019-08-29029 August 2019 Memorandum to C. Regan Summary of August 19, 2019, Partially Closed Public Meeting with Holtec International to Discuss Pre-Application of Thermal Topical Report (W/Enclosure) ML18289A4132018-10-16016 October 2018 Memorandum to A. Rivera-Varona Summary of September 12, 2018, Licensing Meeting with Holtec International to Discuss Technical Topics Related to Two Amendments Applications (W/Enclosure) ML18254A0762018-09-11011 September 2018 Public Meeting Summary: Meeting Handouts for Amendment No. 13 to Certificate of Compliance No. 1014 for the HI-STORE 100 Multi-Purpose Canister Storage System Docket No. 72-1014: Summary of Technical Issues ML13119A5812008-04-0909 April 2008 April 9, 2008, Conference Call Summary Hydrogen Event at CSG 2024-07-23
[Table view] Category:Memoranda
MONTHYEARML24192A1662024-07-23023 July 2024 Summary of June 17, 2024 Pre-application Meeting for Amendment No. 19 to the HI-STORM 100 System ML24159A0402024-06-17017 June 2024 Public Memo: Redacted Summary of April 24, 2024, Pre-Application Meeting with Holtec International on Proposed Amendment 19 to the HI-STORM 100 Storage System ML24095A0402024-05-20020 May 2024 0 User Need Rulemaking Memo for HI-STORM 100 Cask System, Certificate of Compliance No. 1014, Renewed Amendment No. 18 ML24066A1632024-03-0808 March 2024 Memorandum - Summary of February 8, 2024 Public Meeting with Holtec International and Holtec Users Group on EA 23-044 and Path Forward ML24067A3022024-03-0808 March 2024 Memorandum: Summary of March 6, 2024, Public Meeting with Holtec International Inc. and the Holtec Users Group to Discuss the Path Forward for General Licensees Affected by the Continuous Basket Shims Basket Design Change ML24018A0852024-01-31031 January 2024 Safety Determination of a Potential Structural Failure of the Full Basket During Accident Conditions for the HI-STORM 100 and HI-STORM Flood/Wind Dry Cask Storage Systems ML23123A1032023-12-20020 December 2023 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 16 ML23313A1172023-11-21021 November 2023 October 26, 2023 Summary of Holtec International Pre-decisional Enforcement Conference ML22313A0382022-12-19019 December 2022 Corrected User Need for Rulemaking for Amendment No. 17 to HI-STORM 100 System ML22297A1272022-10-31031 October 2022 Summary of Meeting with Holtec International to Discuss Clarification of Holtecs Responses to Request for Additional Information for the Shielding Topical Report ML22175A0872022-08-24024 August 2022 Preliminary HI-STORM 100 Amendment 17 User Need Memo ML22207B7842022-08-0101 August 2022 Memo Meeting Summary for CoC No. 1014, Amendment No. 18 - Rsi Clarifications ML22098A2342022-04-14014 April 2022 User Need Memo for Renewal of CoC No. 1014 (HI-STORM 100 Cask System) ML21326A0812021-11-30030 November 2021 November 10, 2021, Summary of Public Meeting with Holtec International to Discuss Pre-Application of Certificate of Compliance No. 1014, Amendment No. 18 ML21237A0432021-08-25025 August 2021 Summary of July 27, 2021, Public Meeting with Holtec International to Discuss Certificate of Compliance No. 1014 for the HI-STORM 100, Amendment No. 16, Graded Approach ML21082A0852021-04-0909 April 2021 Summary of Closed Meeting with Holtec International and U.S. Nuclear Regulatory Commission Regarding Topical Report for Allowance of Heat Load Patterns in Hi-Storm 100 and Hi-Storm FW Systems ML21077A2682021-03-22022 March 2021 Summary of March 10, 2021, Public Meeting with Holtec International to Discuss Pre-Application of Shielding Method of Evaluation Topical Report ML20295A4132021-01-27027 January 2021 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 15 ML20064F6162020-02-29029 February 2020 January 15, 2020, Summary of Meeting with Holtec International, Inc., to Discuss the Upcoming Submittal of the Application for Renewal of the Storage Certificate of Compliance No. 1014 for the HI-Storm 100 Cask System ML19330E4052019-12-0404 December 2019 Holtec Thermal Topical Report Pre-application Meeting #2 Summary ML19241A2762019-08-29029 August 2019 Memorandum to C. Regan Summary of August 19, 2019, Partially Closed Public Meeting with Holtec International to Discuss Pre-Application of Thermal Topical Report (W/Enclosure) ML19120A0572019-07-0909 July 2019 Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14 ML19071A2942019-03-12012 March 2019 Regulatory History for CoC 1014 Amendment Nos. 11 and 12 ML19024A0502019-01-24024 January 2019 Summary of Partially Closed Pre-Application Meeting with Holtec International to Discuss Proposed Amendment Application to CoC No. 1014 for HI-STORM 100 Multipurpose Canister Storage System (W/Encl. 1) ML18351A1722019-01-17017 January 2019 Memorandum to K. Morgan-Butler User Need for Rulemaking for Amendment No. 13 to the Holtec International HI-STORE 100 Cask System ML18306A7682018-11-0101 November 2018 Memorandum to Y. Diaz-Sanabria Summary of October 17, 2018, Partially Closed Pre-Application Meeting with Holtec International to Discuss Proposed Amendment Application to Certificate of Compliance No. 1014 for HI-STORM 100 (W/Enclosure 1) ML18289A4132018-10-16016 October 2018 Memorandum to A. Rivera-Varona Summary of September 12, 2018, Licensing Meeting with Holtec International to Discuss Technical Topics Related to Two Amendments Applications (W/Enclosure) ML18087A0562018-05-25025 May 2018 Memorandum to K. Morgan-Butler User Need for Rulemaking for the Holtec Hi-Storm 100 Cask System, Amendment No. 12 ML17143A1552017-06-0606 June 2017 Memorandum to C. Bladey Notice of Availability of Exemption for Entergy Energy Operations, Inc., Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation ML17045A5282017-05-25025 May 2017 Memo to C. Bladey Notice of Availability of Environmental Assessment and Finding of No Significant Impact for Entergy Nuclear Operations, Inc., Vermont Yankee Nuclear Power Station, Independent Spent Fuel Storage Installation Exemption Requ ML14351A2602014-12-19019 December 2014 Memo C K Bladey Re Notice of Issuance of Exemption from Holtec Intl CoC No. 1014 Fuel Specification and Loading Conditions at Arkansas Nuclear One ISFSI ML14345B0652014-12-11011 December 2014 Memo C Bladey Re Federal Register Notice of Issuance of Environmental Assessment and Finding of No Significant Impact ANO Units 1 & 2 ISFSI 72-12 and 72-1014 ML0726300142007-09-26026 September 2007 L. Reyes Memo Direct Final Rule - HI-STORM 100, Amend 4 - EDO Pkg. - to Amend 10 CFR Part 72 List of Approved Spent Fuel Storage Casks ML0215803662002-06-0606 June 2002 Memo to R. Bellamy, RGN-I from: M. Tokar Subject: Region I Independent Spent Fuel Storage Installation Inspection Plans Attachment: Sfpo Comments to Region I Integrated Inspection Plans 2024-07-23
[Table view] |
Text
MEMORANDUM TO:
Linda Howell, Deputy Director Division of Fuel Management Office of Nuclear Material Safety and Safeguards FROM:
Christian Jacobs, Sr. Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards
SUBJECT:
SUMMARY
OF OCTOBER 19, 2022, PUBLIC MEETING WITH HOLTEC INTERNATIONAL TO DISCUSS CLARIFICATIONS OF HOLTECS RESPONSES TO THE REQUEST FOR ADDITIONAL INFORMATION FOR THE SHIELDING TOPICAL REPORT On October 19, 2022, an Observation public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and Holtec International (Holtec, the applicant). The purpose of the meeting was for NRC staff to seek clarifications (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22265A131) regarding Holtecs responses to a request of additional information (RAI) (ML22038A940) pertaining to the application of a Topical Report on Methodology for Fuel Qualification. The meeting notice and agenda, dated October 19, 2022, are available in ADAMS at Accession No. ML22272A004. Enclosure 1 to this document contains a summary of the clarification questions asked by NRC staff, and the responses/discussion between Holtec and NRC staff during the meeting. Enclosure 2 contains the meeting attendance list.
No regulatory decisions were made during the meeting. Two members of the public attended the meeting. No one asked any questions during the Questions and Answers session. Holtec did not commit to a date when supplemental responses will be provided to the unresolved RAIs.
Holtec will follow-up with the NRC Project Manager regarding the submittal date for the supplemental response after Holtec has determined the timeframe needed to develop the responses.
CONTACT: Christian Jacobs, NMSS/DFM 301-415-6825 CAC: 001028 Docket No.: 72-1014 EPID: L-2022-LLA-0002
Enclosures:
- 1. Summary of RAI discussion between NRC and Holtec staff
- 2. List of Attendees October 31, 2022 Signed by Jacobs, Christia on 10/31/22
ML22297A124 (pkg), ML22297A127 (memo),
ML22297A125 (Enclosure 1), ML22297A126 (Enclosure 2),
ML22272A004 (meeting notice)
OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NAME CJacobs WWheatley YDiazSanabria DATE 10/25/2022 10/25/2022 10/28/2022