IR 05000309/1989011
| ML20247N826 | |
| Person / Time | |
|---|---|
| Site: | Maine Yankee |
| Issue date: | 09/19/1989 |
| From: | Jerrica Johnson NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Frizzle C Maine Yankee |
| Shared Package | |
| ML20247N832 | List: |
| References | |
| NUDOCS 8909260311 | |
| Download: ML20247N826 (2) | |
Text
,
_ _ _ _ _ _
+-
,
.
.
-
SEP 191989 Docket / License: 50-309/DPR-36 Maine Yankee Atomic Power Company ATTN:
Mr. C. D. Frizzle President 83 Edison Drive-Augusta, Maine 04336 Subject-Resident Inspection 50-309/89-11 (8/1-31/89)
Gentlemen:
This transmits the August 1-31, 1989 inspection findings by Messrs. C. Holden and R. Freudenberger at the Maine Yankee Atomic Power Plant. Those findings have been discussed with Dr. Boulette and Mr. R. Blackmore of your staff.
This inspection identified instances where additional management or supervisory attention is needed.
Examp es included overfilling the spent resin storage tank and troubleshooting which resulted in a dropped Control Element Assembly.
In addition, radiological controls implemented for the low pressure safety in-jection pump overhaul indicate a need for further supervisory attention to pre-vent the spread of contamination outside of work boundaries.
Thank you for your cooperation in these matters.
Sincerely, Original Signed By:
Jon R. Johnson Jon R. Johnson, Chief Projects Branch No. 3 Division of Reactor Projects Enclosure: NRC Region I Inspection Report 50-309/89-11 cc w/ encl:
J. H. Garrity, Vice President, Engineering and Licensing
!
E. T. Boulette, Vice President Operations R. W. Blackmore, Acting Plant Manager G. D. Whittier, Manager Nuclear Engineering and Licensing P. L. Anderson, Project Manager YAEC J. A. Ritsher, Attorney (Ropes and Gray)
Public Document Room (PDR)
!
Local Public Document Room (LPDR)
'
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector State of Maine (2)
0FFICIAL RECORD COPY IR MY 89-11 - 0001.0.0 gg 09/14/89 l
8909260311 890919 l
PDR ADOCK 0500030 '
/
l
roc
_ _ _ _
h_ _ __.
__
~ -
_
J'. ' V
,
l
Saine Yankee Atomic Power Company
'
SEP !9 m bec w/ enc 1:
Region I Docket Rocm (with concurrences)
Management Assistant, DRMA (w/o encl.)
DRP Section Chief H. Eichenholz, SRI, Yankee E. Leeds, LPM, NRR J. Durr, RI (see Detail 3.c)
C. Anderson, RI (see Detail-3.c)
R. Keimig, RI (see Detail 6)
W. Pasciak, RI (see Detail 7)
W. Lancaster, DRSS (see Detail 6)
-Te Oqe r, 6 60 RI:DRP RI:DRP RI:DRP RI RP
@&
Q? V P
Freudenberger Holden McCabe Jo nson 9/14/89 q\\d q(M
'l li
0FFICIAL RECORD COPY IR MY 89-11 - 0002.0.0 09/14/89 i
- _ _ _