MONTHYEARIR 05000309/20240012024-06-26026 June 2024 Company – Independent Spent Fuel Storage Installation NRC Inspection Reports 07200030/2024001 And05000309/2024001 IR 07200030/20234012023-01-26026 January 2023 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2023401 (Letter Only) IR 07200030/20224012022-10-11011 October 2022 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2022401 IR 05000309/20210012021-10-28028 October 2021 Company - NRC Independent Spent Fuel Storage Installation Inspection Report Nos. 07200030/2021001 and 05000309/2021001 IR 07200030/20204012020-10-21021 October 2020 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2020401 IR 05000309/20180012018-05-30030 May 2018 NRC Independent Spent Fuel Storage Installation Report Nos. 07200030/2018001 and 05000309/2018001, Maine Yankee Atomic Power Company, Wiscasset, Maine Site IR 07200030/20184012018-05-17017 May 2018 IR 07200030-18-401, on May 17, 2018, Maine Yankee - NRC ISFSI Security Inspection Report 07200030/2018401 (Cover Letter Only) IR 05000309/20160012016-05-18018 May 2016 IR 07200030-16-001 and 05000309-16-001 on 4/19/16, Maine Yankee Atomic Power Company, Wiscasset, Me Site IR 07200030/20140012014-05-0606 May 2014 IR 07200030-14-001, on 04/16/14, Independent Spent Fuel Storage Installation, Maine Yankee Atomic Power Company, Wiscasset, Me Site ML1036300172010-12-28028 December 2010 IR 07200030-10-002, on 12/01/10, Maine Yankee Atomic Power Company, Wiscasset, Me (Transmittal Letter) IR 07200030/20100022010-12-28028 December 2010 IR 07200030-10-002, on 12/01/10, Maine Yankee Atomic Power Company, Wiscasset, Me IR 05000309/20080012008-01-28028 January 2008 IR 05000309-08-001, on 06/04/2007 - 07/02/2007 and 11/15/2007 - 12/31/2007, Maine Yankee, Wiscasset, Maine IR 05000309/20050012005-10-0505 October 2005 IR 05000309-05-001 on 02/05/2005 - 07/29/2005 for Maine Yankee Atomic Power Company, Wiscasset, Maine IR 05000309/20050022005-09-30030 September 2005 IR 05000309-05-002 on 06/10/2005 - 09-09/2005, Maine Yankee, Licensee Safety Reviews, Design Changes, and Modifications; Final Status Surveys (Fss); and Radioactive Waste Management Programs IR 05000309/20040022005-02-0101 February 2005 IR 05000309-04-002, on 05/24/2004 - 12/31/2004, Maine Yankee Atomic Power Company, Integrated Inspection IR 05000309/20040012004-08-18018 August 2004 IR 05000309-04-001, on January 12, 2004 - July 29, 2004, Maine Yankee Atomic Power Company IR 05000309/19990011999-06-0707 June 1999 Insp Rept 50-309/99-01 on 990214-0513.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000309/19980051999-03-26026 March 1999 Insp Rept 50-309/98-05 on 981101-990213.Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Licensee Operations,Engineering & Plant Support IR 05000309/19980041998-11-27027 November 1998 Insp Rept 50-309/98-04 on 980803-1031.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000306/19960091998-10-0808 October 1998 Discusses Results of Several NRC Insp Repts 50-306/96-09, 50-309/96-10,50-309/96-11,50-309/96-16 & 50-309/97-01, Conducted Between 960715 & 970315,three Investigations Repts 1-95-050,1-96-025 & 1-96-043 & Forwards Notice of Violation IR 05000309/19980031998-09-28028 September 1998 Insp Rept 50-309/98-03 on 980503-0801.No Violations Noted. Major Areas Inspected:Operations,Engineering & Plant Support IR 05000309/19980021998-08-26026 August 1998 Insp Rept 50-309/98-02 on 980317-0506.No Violations Noted. Major Areas Inspected:Water Samples Collected from within & in Vicinity of Wiscasset Landfill IR 05000309/19980011998-05-20020 May 1998 Forwards Insp Rept 50-309/98-01 on 980308-0502 & Nov. Violation Re Poor Implementation of Spent Fuel Pool Foreign Matl Exclusion Program.Vague Procedure & Poor Worker Training Noted IR 05000309/19970091998-05-15015 May 1998 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-309/97-09. Corrective Actions Will Be Examined During Future Insp IR 05000309/19970081997-12-29029 December 1997 Insp Rept 50-309/97-08 on 970908-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Security & Safeguards Activities IR 05000309/19970071997-10-0101 October 1997 Insp Rept 50-309/97-07 on 970728-0907.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19970041997-09-29029 September 1997 Forwards NRC Operator Licensing Exam Rept 50-309/97-04OL (Including Completed & Graded Tests) for Tests Administered on 970609-12 IR 05000309/19970031997-08-28028 August 1997 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-309/97-03 IR 05000309/19970061997-08-14014 August 1997 Insp Rept 50-309/97-06 on 970609-0727.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000309/19960121997-07-31031 July 1997 Ack Receipt of 970107 & 0425 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-309/96-12 & 50-309/96-14.Security Violation Involving Control of Safeguards Info Discussed IR 05000309/19970051997-07-11011 July 1997 Insp Rept 50-309/97-05 on 970427-0608.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000309/19970011997-05-0202 May 1997 Insp Rept 50-309/97-01 on 970126-0315.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint, Plant Support & Conduct of Security & Safeguards Activities IR 05000309/19960141997-04-0808 April 1997 Errata to Insp Rept 50-309/96-14.Second Bullet on Page 39 Contained Typo IR 05000309/19960161997-02-11011 February 1997 Insp Rept 50-309/96-16 on 961208-970128.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19960131997-01-15015 January 1997 Insp Rept 50-309/96-13 on 961027-1207.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19960091996-11-20020 November 1996 Insp Rept 50-309/96-09 on 960804-0914.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19960111996-11-20020 November 1996 Insp Rept 50-309/96-11 on 960811-0913.Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Surveillance Procedures,Test & Independent Oversight Activities IR 05000309/19960101996-09-20020 September 1996 Insp Rept 50-309/96-10 on 960806-09.Violation Noted But Not Cited.Major Areas Inspected:Engineering Support of Facility & Equipment IR 05000309/19930231993-12-16016 December 1993 Insp Rept 50-309/93-23 on 931012-1119.No Violations Noted. Major Areas Inspected:Plant Activities Including Operations, Maint & Surveillance,Engineering & Technical Support & Overall Plant Support IR 05000309/19930261993-12-14014 December 1993 Exam Rept 50-309/93-26OL on 931115 & 16-18.Exam Results: All Individuals Passed Test & Were Issued Licenses IR 05000309/19930251993-12-0808 December 1993 Insp Rept 50-309/93-25 on 931115-19.No Violations Noted. Major Areas Inspected:Protected Area & Isolation Zone Lighting,Vital Area Physical Barriers & Detection Aids, Protected & Vital Area Acess of Personnel & Power Supply IR 05000309/19930241993-11-24024 November 1993 Insp Rept 50-309/93-24 on 931108-12.Inspectors Found Effective EP Program Implementation in All Areas.Major Areas Inspected:Ep Program Changes,Emergency Facilities,Equipment & Supplies & Organization & Mgt Control IR 05000309/19930221993-10-25025 October 1993 Insp Rept 50-309/93-22 on 930830-1011.Violation Noted But Not Cited.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Overall Plant Support IR 05000309/19930171993-10-22022 October 1993 Insp Rept 50-309/93-17 on 930917-21.Violations Noted.Major Areas Inspected:Testing of safety-related MOVs Witnessed by Inspector & Safety of Equipment,Matls & Personnel IR 05000309/19930211993-10-19019 October 1993 Insp Rept 50-309/93-21 on 930823-27.No Violations Noted. Major Areas Inspected:Emergency Diesel Generator Load Permissive Relays IR 05000309/19930181993-09-14014 September 1993 Insp Rept 50-309/93-18 on 930728-0829.No Violations Noted. Major Areas Inspected:Operations,Maint/Surveillance, Engineering/Technical Support & Plant Support IR 05000309/19920211993-01-25025 January 1993 Insp Rept 50-309/92-21 on 921120-1231.No Violations Noted. Major Areas Inspected:Plant Operations,Maint & Surveillance Activities,Security,Engineering & Technical Support & Safety Assessment IR 05000309/19920091993-01-25025 January 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-309/92-09 IR 05000309/19930011993-01-15015 January 1993 Insp Rept 50-309/93-01 on 930104-08.No Violations Noted. Major Areas Inspected:Mgt Organization,Radiation Control During Normal Operations,Alara & Implementation of Programs IR 05000309/19920801992-12-23023 December 1992 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp 50-309/92-80.Actions Re Failure to Perform Review of Mod of Power Supply for App R DG Fuel Oil Day Tank Level Alarm Sensor Will Be Examined 2024-06-26
[Table view] Category:Letter
MONTHYEARIR 05000309/20240012024-06-26026 June 2024 Company – Independent Spent Fuel Storage Installation NRC Inspection Reports 07200030/2024001 And05000309/2024001 ML24124A1372024-04-30030 April 2024 Independent Spent Fuel Storage Installation - 2023 Individual Monitoring NRC Form 5 Report ML24117A0602024-04-23023 April 2024 Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2023 ML24094A0602024-03-28028 March 2024 Independent Spent Fuel Storage Installation, Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for the Maine Yankee Independent Spent Fuel Storage Installation ML24074A3822024-03-11011 March 2024 Independent Spent Fuel Storage Installation, Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML24074A3812024-03-11011 March 2024 Independent Spent Fuel Storage Installation, Decommissioning Funding Assurance Status Report NG-24-0001, 2024 Annual Decommissioning and Spent Fuel Management Funding Status Report and Independent Spent Fuel Storage Installation (ISFSI) Decommissioning Financial Assurance Update2024-03-0606 March 2024 2024 Annual Decommissioning and Spent Fuel Management Funding Status Report and Independent Spent Fuel Storage Installation (ISFSI) Decommissioning Financial Assurance Update ML23286A3262024-02-29029 February 2024 Issuance of Exemption for Maine Yankee Atomic Power Company Regarding Maine Yankee Independent Spent Fuel Storage Installation ML24025A0392024-01-12012 January 2024 Independent Spent Fuel Storage Installation, Property Insurance Coverage ML23342A1112024-01-0909 January 2024 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML23117A0452023-04-25025 April 2023 Independent Spent Fuel Storage Installation, Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2022 ML23113A0052023-03-31031 March 2023 Request for Exemption from 10 CFR 50.82 10 CFR 50.75 for the Maine Yankee Independent Spent Fuel Storage Installation NG-23-0001, 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report2023-03-27027 March 2023 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report ML23068A0112023-03-0606 March 2023 Independent Spent Fuel Storage Installation, Decommissioning Funding Assurance Status Report ML23068A0132023-03-0606 March 2023 Independent Spent Fuel Storage Installation, Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML22340A4622023-02-24024 February 2023 Closeout Letter to Maine Yankee Atomic Power Company Regarding 2018 and 2021 Updated DFPs for Maine Yankee ISFSI IR 07200030/20234012023-01-26026 January 2023 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2023401 (Letter Only) ML23026A0802023-01-17017 January 2023 Company - Property Insurance Coverage IR 07200030/20224012022-10-11011 October 2022 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2022401 ML22216A0682022-07-28028 July 2022 Independent Spent Fuel Storage Installation, Supplemental Information for the Three-Year Update to the Independent Spent Fuel Storage Installation Decommissioning Funding Plan ML22088A0212022-04-0101 April 2022 Independent Spent Fuel Storage Installation, 10 CFR 72.48 Biennial Report ML22088A0182022-04-0101 April 2022 Independent Spent Fuel Storage Installation, 10 CFR 50.59 Biennial Report NG-22-0041, And Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report2022-03-31031 March 2022 And Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report ML22088A0122022-03-14014 March 2022 Independent Spent Fuel Storage Installation - Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML22088A0162022-03-14014 March 2022 Independent Spent Fuel Storage Installation, Decommissioning Funding Assurance Status Report ML22011A1332022-01-31031 January 2022 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML22045A0662022-01-20020 January 2022 Independent Spent Fuel Storage Installation - Property Insurance Coverage ML22045A0652022-01-20020 January 2022 Independent Spent Fuel Storage Installation, Nuclear Liability Insurance Coverage ML21362A1592021-12-10010 December 2021 Independent Spent Fuel Storage Installation, Three-Year Update to the Independent Spent Fuel Storage Installation Decommissioning Funding Plan IR 05000309/20210012021-10-28028 October 2021 Company - NRC Independent Spent Fuel Storage Installation Inspection Report Nos. 07200030/2021001 and 05000309/2021001 NG-21-0006, 2021 Annual Decommissioning and Spent Fuel Management Funding Status Report2021-03-31031 March 2021 2021 Annual Decommissioning and Spent Fuel Management Funding Status Report ML21077A1672021-03-0202 March 2021 Independent Spent Fuel Storage Installation - Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML21105A7392021-03-0202 March 2021 Independent Spent Fuel Storage Installation - Decommissioning Funding Assurance Status Report ML21042B5932021-01-27027 January 2021 Independent Spent Fuel Storage Installation, Property Insurance Coverage ML21042B5942021-01-27027 January 2021 Independent Spent Fuel Storage Installation, Nuclear Liability Insurance Coverage ML21012A3992021-01-13013 January 2021 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML21042B8962021-01-11011 January 2021 Independent Spent Fuel Storage Installation, Biennial Update of the Defueled Safety Analysis Report ML21050A2302021-01-11011 January 2021 Independent Spent Fuel Storage Installation - Formal Announcement of New ISFSI Manager IR 07200030/20204012020-10-21021 October 2020 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2020401 ML20136A3372020-04-22022 April 2020 Independent Spent Fuel Storage Installation, Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2019 ML20101H9312020-04-0101 April 2020 Independent Spent Fuel Storage Installation - 10 CFR 50.59 Biennial Report ML20097B6692020-03-19019 March 2020 Independent Spent Fuel Storage Installation, Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML20087J6772020-03-11011 March 2020 Independent Spent Fuel Storage Installation - Decommissioning Funding Assurance Status Report ML20015A5492020-01-15015 January 2020 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML19241A4582019-08-29029 August 2019 Letter to T. Matthews Maine Yankee Atomic Power Company - Threshold Determination That NRC Consent Is Not Required in Connection with Acquisition of Emera Maine by Enmaz Corporation ML19182A0322019-07-0505 July 2019 Letter to J. Brown Maine Yankee Atomic Power Company Exemption Request from Certain Requirements of 10 CFR 72.214 for the ISFSI ML19182A0402019-07-0505 July 2019 Letter to P. Dostie Maine Yankee Atomic Power Company Exemption Request from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for the ISFSI ML19113A1032019-04-23023 April 2019 Request for NRC Threshold Determination That NRC Consent Is Not Required in Connection with Acquisition of Emera Maine by Enmax Corporation ML19127A2892019-04-16016 April 2019 Independent Spent Fuel Storage Installation, Submittal of Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2018 ML19112A0242019-04-11011 April 2019 Independent Spent Fuel Storage Installation, Reference Correction - Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 2024-06-26
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION May 30, 2018
SUBJECT:
NRC INDEPENDENT SPENT FUEL STORAGE INSTALLATION INSPECTION REPORT NOS. 07200030/2018001 AND 05000309/2018001, MAINE YANKEE ATOMIC POWER COMPANY, WISCASSET, MAINE SITE
Dear Mr. Brown:
On May 1, 2018, the U.S. Nuclear Regulatory Commission (NRC) completed a safety inspection of the Maine Yankee Atomic Power Company (Maine Yankee) Independent Spent Fuel Storage Installation (ISFSI). The inspection examined activities under your license as they relate to safety and compliance with the Commission's regulations and the conditions of your license.
The inspection consisted of observations by the inspectors, interviews with personnel, and a review of records and procedures. The results of the inspection were discussed with you at the conclusion of the inspection. The enclosed report presents the results of this inspection.
Within the scope of this inspection, no violations were identified.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response, if you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room or from the NRC document system (ADAMS), accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction.
Current NRC regulations and guidance are included on the NRC's website at www.nrc.gov; select Nuclear Materials; Med, Ind, & Academic Uses; then Regulations, Guidance and Communications. The current Enforcement Policy is included on the NRC's website at www.nrc.gov; select About NRC, Organizations & Functions; Office of Enforcement; Enforcement documents; then Enforcement Policy (Under 'Related Information'). You may also obtain these documents by contacting the Government Printing Office (GPO) toll-free at 1-866-512-1800. The GPO is open from 8:00 a.m. to 5:30 p.m. EST, Monday through Friday (except Federal holidays).
J. No reply to this letter is required. Please contact Orysia Masnyk Bailey at 864-427-1032 if you have any questions regarding this matter.
Sincerely,
~/~
Raymond J. Powell, Chief Decommissioning, ISFSI and Reactor HP Branch Division of Nuclear Materials Safety Dockets Nos.; 07200030, 05000309 License Nos.: SFGL-14, DPR-36
Enclosure:
Inspection Report Nos. 07200030/2018001 and 05000309/2018001
REGION I==
INSPECTION REPORT Inspection Nos. 07200030/2018001 and 05000309/2018001 Docket Nos. 07200030 and 05000309 License Nos. DPR-36 and SFGL-14 Licensee: Maine Yankee Atomic Power Company Location: 321 Old Ferry Road Wiscasset, ME 04578 Inspection Dates: May 1, 2018, 2018 Inspectors: Orysia Masnyk Bailey Health Physicist Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety Katherine Warner Health Physicist Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety Approved By: Raymond J. Powell, Chief Decommissioning, ISFSI, and Reactor HP Branch Division of Nuclear Materials Safety Enclosure Inspection Report 07200030/2018001 and 05000309/2018001
EXECUTIVE SUMMARY Maine Yankee Atomic Power Company NRC Inspection Report Nos. 07200030/2018001 and 05000309/2018001 An announced safety inspection was conducted on May 1, 2018, at the Maine Yankee Atomic Power Company (Maine Yankee) Independent Spent Fuel Storage Installation (ISFSI). The inspectors assessed whether Maine Yankee personnel were operating and maintaining ISFSI programs at an away-from-reactor (AFR) ISFSI in conformance with the commitments and requirements contained in the Final Safety Analysis Report (FSAR), Safety Evaluation Report (SER), Certificate of Compliance (CoC), Technical Specifications (TS), Quality Assurance (QA)
program, Maine Yankee procedures, and 10 CFR Part 72. The inspectors' review was directed toward confirming the ongoing adequacy of the radiation protection, fire protection, emergency preparedness, surveillance, maintenance, environmental monitoring, training, QA, and corrective action programs. The inspectors observed activities, interviewed personnel, and reviewed records and procedures. Based on the results of this inspection, no findings of significance were identified.
Inspection Report 07200030/2018001 and 05000309/2018001
The inspectors reviewed the most recent independent audit of the ISFSI program. The inspectors determined that issues were entered into the corrective action program, prioritized, and evaluated commensurate with their safety significance. Corrective actions were implemented to address identified issues and were tracked to closure. The QA program evaluated changes in the ISFSI program to ensure that any changes that were implemented would not decrease the overall effectiveness of the program. The inspector also reviewed Maine Yankee's 10 CFR 72.212 evaluation report and ensured it was being appropriately updated.
c. Findings Based on the results of this inspection, no findings of significance were identified.
II. Exit Meeting Summary On May 1, 2018, the inspectors presented the inspection results to J. Stanley Brown, ISFSI Manager and other Maine Yankee personnel.
Inspection Report 07200030/2018001 and 05000309/2018001
SUPPLEMENTAL INFORMATION PARTIAL UST OF PERSONS CONTACTED M. Atwood, Shift Supervisor A. Blake, Facilities Specialist J. Bourassa, RPM/QA Representative J. Stanley Brown, ISFSI Manager S. Day, Licensing Engineer P. Dostie, Maine Nuclear Safety Inspector L. Doucette, Technical Specialist P. Fitzmaurice, Security Project Manager J. Lenois, 3 Yankee Security Program Manager D. Mercer, Operations Specialist J. Miller, ISFSI Security Supervisor R. Mitchell, Assistant Director of Operations ITEMS OPEN, CLOSED, AND DISCUSSED None UST OF DOCUMENTS REVIEWED Audits and Reports 2016 June Approved RP Survey 2017 June Approved RP Survey 2017 VCC Vent Screen Approved Survey Neutron Survey June 2013 MY Quality Assurance Program for the MY ISFSI, Rev. 36, December 2015 Annual Special Nuclear Material (SNM) Report for 2017, 8/24/2017 Miscellaneous RWP 2018-01, 02, and 03, '12/11/2017 Continuous Improvement Plan Integrated Improvement Plan Maine Yankee Quality Assurance Audit No. MY-18-A05-01, 4/26/2018 MY ISFSI Off-Site Dose Calculation Manual, Change No. 36, December 3, 2014 MY- RCM-003, Rev. 2, Radiation Protection Program, February 10, 2015 MY- RCM-014, Rev. 0, Radwaste Management/Radioactive Shipment, September 15, 2011 MY- RCM-021, Rev. 1, Offsite Dose Calculation Manual, February 10, 2015 MY- RCM-022, Rev. 0, Special Nuclear Materials Accountability, November 10, 2011 MY- RCM-030, Rev. 2, GTCC Waste Storage, January 21, 2016 Quality Assurance Program for the MY ISFSI, Rev. 36, December 16, 2015 Work Order 17-086 Replace al fuel VCC inlet screens Procedures EF-3, Rev. 4, Special Nuclear Material and Greater than Class C Waste Control, Accountability, and Reporting Program FP-1, Rev. 10, ISFSI Fire Protection Program FP-2, Rev. 9, Fire Hazards Analysis FP-3, Rev. 10, ISFSI Fire Fighting Preplan FP-4, Rev. 6, ISFSI Fires and Fire Alarms Inspection Report 07200030/2018001 and 05000309/2018001
FP-5, Rev. 8, Hot Work and Combustible Controls FP-6, Rev. 17, Fire System Surveillance Fp-7, Rev. 3, ISFSI Fire Protection System QA-2, Quality Assurance RP-1, Rev. 4, Conduct of Radiation Protection RP-2, Rev. 15, Radiological Surveys and Postings RP-3, Rev. 6, ISFSI Radiological Environmental Monitoring Program RP-4, Rev. 7, Personnel Radiation Monitoring RP-5, Rev. 3, Radiation Work Permits USJ Of ACRONYMS USED AFR Away-From-Reactor CFR Code of Federal Regulations Coe Certificate of Compliance FSAR Final Safety Analysis Report IP Inspection Procedure ISFSI Independent Spent Fuel Storage Installation LLEA Local Law Enforcement Agencies MY Maine Yankee Atomic Power Company Maine Yankee Maine Yankee Atomic Power Company NSIR Office of Nuclear Security and Incident Response QA Quality Assurance SER Safety Evaluation Report SNM Special Nuclear Material TS Technical Specification vcc Vertical Concrete Cask Inspection Report 07200030/2018001 and 05000309/2018001