Category:INSPECTION REPORT
MONTHYEARIR 05000348/19990051999-09-0202 September 1999 Insp Repts 50-348/99-05 & 50-364/99-05 on 990627-0807.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19990041999-07-26026 July 1999 Insp Repts 50-348/99-04 & 50-364/99-04 on 990516-0626.One Noncited Violation Identified.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000348/19990031999-06-10010 June 1999 Insp Repts 50-348/99-03 & 50-364/99-03 on 990404-0515.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19990021999-04-29029 April 1999 Insp Repts 50-348/99-02 & 50-364/99-02 on 990221-0403.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20205Q1721999-04-0606 April 1999 Partially Withheld Insp Repts 50-348/99-09 & 50-364/99-09 on 990308-10 (Ref 10CFR73.21).Non-cited Violation Identified. Major Areas Inspected:Area of Plant Support Re Physical Security Program for Power Reactors IR 05000348/19990011999-03-19019 March 1999 Insp Repts 50-348/99-01 & 50-364/99-01 on 990110-0220. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19980081999-02-0202 February 1999 Insp Repts 50-348/98-08 & 50-364/98-08 on 981129-990109.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000348/19980141999-01-0808 January 1999 Partially Withheld Insp Repts 50-348/98-14 & 50-364/98-14 on 981207-10 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Procedures & Representative Records,Interviews with Personnel & Observations of Activities in Progress IR 05000348/19980071998-12-28028 December 1998 Insp Repts 50-348/98-07 & 50-364/98-07 on 981018-1128.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980061998-11-10010 November 1998 Insp Repts 50-348/98-06 & 50-364/98-06 on 980830-1017.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980101998-11-0303 November 1998 Insp Repts 50-348/98-10 & 50-364/98-10 on 980908-11.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise & Response in Control Room Simulator & Technical Support Ctr IR 05000348/19980051998-09-28028 September 1998 Insp Repts 50-348/98-05 & 50-364/98-05 on 980712-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980041998-08-10010 August 1998 Insp Repts 50-348/98-04 & 50-364/98-04 on 980601-0711.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20236J7021998-07-0101 July 1998 Insp Repts 50-348/98-03 & 50-364/98-03 on 980412-0530.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19980091998-05-11011 May 1998 Special Insp Repts 50-348/98-09 & 50-364/98-09 on 980323-25. Violations Noted.Major Areas Inspected:Follow Up on OI Rept 2-97-011 Issued on 980209 Re Improper Weld Repair IR 05000348/19980021998-05-0808 May 1998 Insp Repts 50-348/98-02 & 50-364/98-02 on 980221-0411.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980011998-03-23023 March 1998 Insp Repts 50-348/98-01 & 50-364/98-01 on 980111-0221. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19970151998-02-0909 February 1998 Insp Repts 50-348/97-15 & 50-364/97-15 on 971130-980110. No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20198N9961997-12-29029 December 1997 Insp Repts 50-348/97-14 & 50-364/97-14 on 971019-1129. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000348/19970131997-11-20020 November 1997 Partially Withheld Insp Repts 50-348/97-13 & 50-364/97-13 on 971021-24 (Ref 10CFR73.21).Major Areas Inspected:Physical Security Program for Power Reactors ML20199H1541997-11-17017 November 1997 Insp Repts 50-348/97-11 & 50-364/97-11 on 970907-1018. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19970071997-10-10010 October 1997 Insp Repts 50-348/97-07 & 50-364/97-07 on 970825-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Action Program,Including Problem Identification & Resolution IR 05000348/19970101997-10-0606 October 1997 Insp Repts 50-348/97-10 & 50-364/97-10 on 970803-0906. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000348/19970121997-09-26026 September 1997 Insp Repts 50-348/97-12 & 50-364/97-12 on 970818-22. Violations Noted.Major Areas Inspected:Review of Fire Protection Program Activities to Support Design Basis of Silicone Foam Fire Barrier Penetration Seals IR 05000348/19970081997-08-28028 August 1997 Insp Repts 50-348/97-08 & 50-364/97-08 on 970622-0802. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19970061997-07-18018 July 1997 Insp Repts 50-348/97-06 & 50-364/97-06 on 970511-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148K6511997-06-0909 June 1997 Insp Repts 50-348/97-05 & 50-364/97-05 on 970330-0510. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19972011997-05-13013 May 1997 Insp Repts 50-348/97-201 & 50-364/97-201 on 970127-0314.No Violations Noted.Major Areas Inspected:Engineering, Auxiliary Feedwater Sys,Component Cooling Water Sys & Sys Interface Design Review ML20138J6661997-04-28028 April 1997 Insp Repts 50-348/97-03 & 50-364/97-03 on 970216-0329. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support,Including Health Physics ML20137U6021997-04-0202 April 1997 Insp Repts 50-348/97-04 & 50-364/97-04 on 970125-0314. Violations Noted.Major Areas Inspected:Detailed Esfs Review & Walkdown of Units 1 & 2 PRF Sys,Including Associated Surveillance Test & Sys Design Requirements ML20140B7921997-03-17017 March 1997 Insp Repts 50-348/97-01 & 50-364/97-01 on 970104-0215. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19960151997-02-0303 February 1997 Insp Repts 50-348/96-15 & 50-364/96-15 on 961124-970104.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134G3961997-01-24024 January 1997 Insp Repts 50-348/96-14 & 50-364/96-14 on 961209-13.No Violations Noted.Major Areas Inspected:Biennial Emergency Preparedness Exercise ML20133F6921996-12-23023 December 1996 Insp Repts 50-348/96-13 & 50-364/96-13 on 961013-1123. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134J4391996-11-0808 November 1996 Insp Repts 50-348/96-09 & 50-364/96-09 on 960901-1012. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19960111996-10-11011 October 1996 Insp Repts 50-348/96-11 & 50-364/96-11 on 961007-11.No Violations Noted.Major Areas Inspected:Plant Support ML20128J9761996-09-27027 September 1996 Insp Repts 50-348/96-07 & 50-364/96-07 on 960721-0831. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support ML20128H8371996-09-27027 September 1996 Insp Repts 50-348/96-10 & 50-364/96-10 on 960812-16 & 26-30. Violations Noted.Major Areas Inspected:Radiation Monitoring Sys Radwaste Processing & Storage & Operational Radiation Protection Programs IR 05000348/19930301994-01-0606 January 1994 Insp Repts 50-348/93-30 & 50-364/93-30 on 931206-1210.No Violations or Deviations Noted.Major Areas Inspected: Process & Effluent Monitors,Post Accident Sampling Sys, Annual Radiological Environmental Operating Rept IR 05000348/19930291994-01-0505 January 1994 Insp Repts 50-348/93-29 & 50-364/93-29 on 931206-10.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Annual Emergency Preparedness Exercise IR 05000348/19930281993-12-14014 December 1993 Insp Repts 50-348/93-28 & 50-364/93-28 on 931022-1122. Noncited Violation Identified.Major Areas Inspected:Licensee Operations,Maint/Surveillance Activities & Unit 2 Refueling Activities IR 05000348/19930251993-12-0202 December 1993 Insp Repts 50-348/93-25 & 50-364/93-25 on 931018-22 & 931101-05.Noncited Violation Identified.Major Areas Inspected:Sg Tubes,Review Laser Welding Procedures to Be Used for Securing Sleeves & Review Design Changes IR 05000348/19930271993-11-24024 November 1993 Insp Repts 50-348/93-27 & 50-364/93-27 on 931025-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Actions for safety-significant Findings Identified During Electrical Distribution Sys Functional Insp IR 05000348/19930221993-11-17017 November 1993 Insp Repts 50-348/93-22 & 50-364/93-22 on 930925-1022.No Violations Noted.Major Areas Inspected:Maintenance, Surveillance,Industry Technical Issues,Event Repts,Unit 2 Refueling Activities & Continuing Review of self-assessment IR 05000364/19934001993-11-10010 November 1993 Insp Rept 50-364/93-400 on 931004-15.No Violations Noted. Majors Areas Inspected:Review of Licensee ISI Program Submittal & Nondestructive Exams of safety-related Weldments,Hanger & Supports Selected from SI IR 05000348/19930231993-11-10010 November 1993 Insp Repts 50-348/93-23 & 50-364/93-23 on 931012-15.No Violations Noted.Major Areas Inspected:Organization & Mgt Controls,Audits & Appraisals,External & Internal Control, Control of Radioactive Matl & Contamination IR 05000348/19930261993-11-0404 November 1993 Insp Repts 50-348/93-26 & 50-364/93-26 on Stated Dates. Violation Being Considered for Escalated Enforcement Action. Major Areas Inspected:Review of Plant Conditions Re Recent Listed Events IR 05000348/19930241993-11-0101 November 1993 Insp Repts 50-348/93-24 & 50-364/93-24 on 931012-15.No Violations or Deviations Noted.Major Areas Inspected:Isi, Including Nondestructive Exam Procedures & Observation of Work & Work Activities IR 05000348/19930211993-10-21021 October 1993 Insp Repts 50-348/93-21 & 50-364/93-21 on 930830-0925.No Violations Noted.Major Areas Inspected:Operations,Maint, Surveillance,Industry Technical Issues,Event Repts,Unit 2 Refueling Activities & Licensee self-assessment ML20057E4981993-09-29029 September 1993 Insp Repts 50-348/93-13 & 50-364/93-13 on 930816-0903. Violations Noted.Major Areas Inspected:Sws 1999-09-02
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000348/19990051999-09-0202 September 1999 Insp Repts 50-348/99-05 & 50-364/99-05 on 990627-0807.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19990041999-07-26026 July 1999 Insp Repts 50-348/99-04 & 50-364/99-04 on 990516-0626.One Noncited Violation Identified.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000348/19990031999-06-10010 June 1999 Insp Repts 50-348/99-03 & 50-364/99-03 on 990404-0515.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19990021999-04-29029 April 1999 Insp Repts 50-348/99-02 & 50-364/99-02 on 990221-0403.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20205Q1721999-04-0606 April 1999 Partially Withheld Insp Repts 50-348/99-09 & 50-364/99-09 on 990308-10 (Ref 10CFR73.21).Non-cited Violation Identified. Major Areas Inspected:Area of Plant Support Re Physical Security Program for Power Reactors IR 05000348/19990011999-03-19019 March 1999 Insp Repts 50-348/99-01 & 50-364/99-01 on 990110-0220. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19980081999-02-0202 February 1999 Insp Repts 50-348/98-08 & 50-364/98-08 on 981129-990109.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000348/19980141999-01-0808 January 1999 Partially Withheld Insp Repts 50-348/98-14 & 50-364/98-14 on 981207-10 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Procedures & Representative Records,Interviews with Personnel & Observations of Activities in Progress IR 05000348/19980071998-12-28028 December 1998 Insp Repts 50-348/98-07 & 50-364/98-07 on 981018-1128.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980061998-11-10010 November 1998 Insp Repts 50-348/98-06 & 50-364/98-06 on 980830-1017.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980101998-11-0303 November 1998 Insp Repts 50-348/98-10 & 50-364/98-10 on 980908-11.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise & Response in Control Room Simulator & Technical Support Ctr IR 05000348/19980051998-09-28028 September 1998 Insp Repts 50-348/98-05 & 50-364/98-05 on 980712-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980041998-08-10010 August 1998 Insp Repts 50-348/98-04 & 50-364/98-04 on 980601-0711.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20236J7021998-07-0101 July 1998 Insp Repts 50-348/98-03 & 50-364/98-03 on 980412-0530.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19980091998-05-11011 May 1998 Special Insp Repts 50-348/98-09 & 50-364/98-09 on 980323-25. Violations Noted.Major Areas Inspected:Follow Up on OI Rept 2-97-011 Issued on 980209 Re Improper Weld Repair IR 05000348/19980021998-05-0808 May 1998 Insp Repts 50-348/98-02 & 50-364/98-02 on 980221-0411.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980011998-03-23023 March 1998 Insp Repts 50-348/98-01 & 50-364/98-01 on 980111-0221. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19970151998-02-0909 February 1998 Insp Repts 50-348/97-15 & 50-364/97-15 on 971130-980110. No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20198N9961997-12-29029 December 1997 Insp Repts 50-348/97-14 & 50-364/97-14 on 971019-1129. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000348/19970131997-11-20020 November 1997 Partially Withheld Insp Repts 50-348/97-13 & 50-364/97-13 on 971021-24 (Ref 10CFR73.21).Major Areas Inspected:Physical Security Program for Power Reactors ML20199H1541997-11-17017 November 1997 Insp Repts 50-348/97-11 & 50-364/97-11 on 970907-1018. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19970071997-10-10010 October 1997 Insp Repts 50-348/97-07 & 50-364/97-07 on 970825-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Action Program,Including Problem Identification & Resolution IR 05000348/19970101997-10-0606 October 1997 Insp Repts 50-348/97-10 & 50-364/97-10 on 970803-0906. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000348/19970121997-09-26026 September 1997 Insp Repts 50-348/97-12 & 50-364/97-12 on 970818-22. Violations Noted.Major Areas Inspected:Review of Fire Protection Program Activities to Support Design Basis of Silicone Foam Fire Barrier Penetration Seals IR 05000348/19970081997-08-28028 August 1997 Insp Repts 50-348/97-08 & 50-364/97-08 on 970622-0802. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19970061997-07-18018 July 1997 Insp Repts 50-348/97-06 & 50-364/97-06 on 970511-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148K6511997-06-0909 June 1997 Insp Repts 50-348/97-05 & 50-364/97-05 on 970330-0510. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19972011997-05-13013 May 1997 Insp Repts 50-348/97-201 & 50-364/97-201 on 970127-0314.No Violations Noted.Major Areas Inspected:Engineering, Auxiliary Feedwater Sys,Component Cooling Water Sys & Sys Interface Design Review ML20138J6661997-04-28028 April 1997 Insp Repts 50-348/97-03 & 50-364/97-03 on 970216-0329. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support,Including Health Physics ML20137U6021997-04-0202 April 1997 Insp Repts 50-348/97-04 & 50-364/97-04 on 970125-0314. Violations Noted.Major Areas Inspected:Detailed Esfs Review & Walkdown of Units 1 & 2 PRF Sys,Including Associated Surveillance Test & Sys Design Requirements ML20140B7921997-03-17017 March 1997 Insp Repts 50-348/97-01 & 50-364/97-01 on 970104-0215. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19960151997-02-0303 February 1997 Insp Repts 50-348/96-15 & 50-364/96-15 on 961124-970104.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134G3961997-01-24024 January 1997 Insp Repts 50-348/96-14 & 50-364/96-14 on 961209-13.No Violations Noted.Major Areas Inspected:Biennial Emergency Preparedness Exercise ML20133F6921996-12-23023 December 1996 Insp Repts 50-348/96-13 & 50-364/96-13 on 961013-1123. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134J4391996-11-0808 November 1996 Insp Repts 50-348/96-09 & 50-364/96-09 on 960901-1012. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19960111996-10-11011 October 1996 Insp Repts 50-348/96-11 & 50-364/96-11 on 961007-11.No Violations Noted.Major Areas Inspected:Plant Support ML20128J9761996-09-27027 September 1996 Insp Repts 50-348/96-07 & 50-364/96-07 on 960721-0831. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support ML20128H8371996-09-27027 September 1996 Insp Repts 50-348/96-10 & 50-364/96-10 on 960812-16 & 26-30. Violations Noted.Major Areas Inspected:Radiation Monitoring Sys Radwaste Processing & Storage & Operational Radiation Protection Programs IR 05000348/19930301994-01-0606 January 1994 Insp Repts 50-348/93-30 & 50-364/93-30 on 931206-1210.No Violations or Deviations Noted.Major Areas Inspected: Process & Effluent Monitors,Post Accident Sampling Sys, Annual Radiological Environmental Operating Rept IR 05000348/19930291994-01-0505 January 1994 Insp Repts 50-348/93-29 & 50-364/93-29 on 931206-10.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Annual Emergency Preparedness Exercise IR 05000348/19930281993-12-14014 December 1993 Insp Repts 50-348/93-28 & 50-364/93-28 on 931022-1122. Noncited Violation Identified.Major Areas Inspected:Licensee Operations,Maint/Surveillance Activities & Unit 2 Refueling Activities IR 05000348/19930251993-12-0202 December 1993 Insp Repts 50-348/93-25 & 50-364/93-25 on 931018-22 & 931101-05.Noncited Violation Identified.Major Areas Inspected:Sg Tubes,Review Laser Welding Procedures to Be Used for Securing Sleeves & Review Design Changes IR 05000348/19930271993-11-24024 November 1993 Insp Repts 50-348/93-27 & 50-364/93-27 on 931025-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Actions for safety-significant Findings Identified During Electrical Distribution Sys Functional Insp IR 05000348/19930221993-11-17017 November 1993 Insp Repts 50-348/93-22 & 50-364/93-22 on 930925-1022.No Violations Noted.Major Areas Inspected:Maintenance, Surveillance,Industry Technical Issues,Event Repts,Unit 2 Refueling Activities & Continuing Review of self-assessment IR 05000364/19934001993-11-10010 November 1993 Insp Rept 50-364/93-400 on 931004-15.No Violations Noted. Majors Areas Inspected:Review of Licensee ISI Program Submittal & Nondestructive Exams of safety-related Weldments,Hanger & Supports Selected from SI IR 05000348/19930231993-11-10010 November 1993 Insp Repts 50-348/93-23 & 50-364/93-23 on 931012-15.No Violations Noted.Major Areas Inspected:Organization & Mgt Controls,Audits & Appraisals,External & Internal Control, Control of Radioactive Matl & Contamination IR 05000348/19930261993-11-0404 November 1993 Insp Repts 50-348/93-26 & 50-364/93-26 on Stated Dates. Violation Being Considered for Escalated Enforcement Action. Major Areas Inspected:Review of Plant Conditions Re Recent Listed Events IR 05000348/19930241993-11-0101 November 1993 Insp Repts 50-348/93-24 & 50-364/93-24 on 931012-15.No Violations or Deviations Noted.Major Areas Inspected:Isi, Including Nondestructive Exam Procedures & Observation of Work & Work Activities IR 05000348/19930211993-10-21021 October 1993 Insp Repts 50-348/93-21 & 50-364/93-21 on 930830-0925.No Violations Noted.Major Areas Inspected:Operations,Maint, Surveillance,Industry Technical Issues,Event Repts,Unit 2 Refueling Activities & Licensee self-assessment ML20057E4981993-09-29029 September 1993 Insp Repts 50-348/93-13 & 50-364/93-13 on 930816-0903. Violations Noted.Major Areas Inspected:Sws 1999-09-02
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000348/19990051999-09-0202 September 1999 Insp Repts 50-348/99-05 & 50-364/99-05 on 990627-0807.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19990041999-07-26026 July 1999 Insp Repts 50-348/99-04 & 50-364/99-04 on 990516-0626.One Noncited Violation Identified.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000348/19990031999-06-10010 June 1999 Insp Repts 50-348/99-03 & 50-364/99-03 on 990404-0515.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19990021999-04-29029 April 1999 Insp Repts 50-348/99-02 & 50-364/99-02 on 990221-0403.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20205Q1721999-04-0606 April 1999 Partially Withheld Insp Repts 50-348/99-09 & 50-364/99-09 on 990308-10 (Ref 10CFR73.21).Non-cited Violation Identified. Major Areas Inspected:Area of Plant Support Re Physical Security Program for Power Reactors IR 05000348/19990011999-03-19019 March 1999 Insp Repts 50-348/99-01 & 50-364/99-01 on 990110-0220. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19980081999-02-0202 February 1999 Insp Repts 50-348/98-08 & 50-364/98-08 on 981129-990109.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000348/19980141999-01-0808 January 1999 Partially Withheld Insp Repts 50-348/98-14 & 50-364/98-14 on 981207-10 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Procedures & Representative Records,Interviews with Personnel & Observations of Activities in Progress IR 05000348/19980071998-12-28028 December 1998 Insp Repts 50-348/98-07 & 50-364/98-07 on 981018-1128.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980061998-11-10010 November 1998 Insp Repts 50-348/98-06 & 50-364/98-06 on 980830-1017.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980101998-11-0303 November 1998 Insp Repts 50-348/98-10 & 50-364/98-10 on 980908-11.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise & Response in Control Room Simulator & Technical Support Ctr IR 05000348/19980051998-09-28028 September 1998 Insp Repts 50-348/98-05 & 50-364/98-05 on 980712-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980041998-08-10010 August 1998 Insp Repts 50-348/98-04 & 50-364/98-04 on 980601-0711.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20236J7021998-07-0101 July 1998 Insp Repts 50-348/98-03 & 50-364/98-03 on 980412-0530.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19980091998-05-11011 May 1998 Special Insp Repts 50-348/98-09 & 50-364/98-09 on 980323-25. Violations Noted.Major Areas Inspected:Follow Up on OI Rept 2-97-011 Issued on 980209 Re Improper Weld Repair IR 05000348/19980021998-05-0808 May 1998 Insp Repts 50-348/98-02 & 50-364/98-02 on 980221-0411.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980011998-03-23023 March 1998 Insp Repts 50-348/98-01 & 50-364/98-01 on 980111-0221. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19970151998-02-0909 February 1998 Insp Repts 50-348/97-15 & 50-364/97-15 on 971130-980110. No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20198N9961997-12-29029 December 1997 Insp Repts 50-348/97-14 & 50-364/97-14 on 971019-1129. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000348/19970131997-11-20020 November 1997 Partially Withheld Insp Repts 50-348/97-13 & 50-364/97-13 on 971021-24 (Ref 10CFR73.21).Major Areas Inspected:Physical Security Program for Power Reactors ML20199H1541997-11-17017 November 1997 Insp Repts 50-348/97-11 & 50-364/97-11 on 970907-1018. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19970071997-10-10010 October 1997 Insp Repts 50-348/97-07 & 50-364/97-07 on 970825-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Action Program,Including Problem Identification & Resolution IR 05000348/19970101997-10-0606 October 1997 Insp Repts 50-348/97-10 & 50-364/97-10 on 970803-0906. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000348/19970121997-09-26026 September 1997 Insp Repts 50-348/97-12 & 50-364/97-12 on 970818-22. Violations Noted.Major Areas Inspected:Review of Fire Protection Program Activities to Support Design Basis of Silicone Foam Fire Barrier Penetration Seals IR 05000348/19970081997-08-28028 August 1997 Insp Repts 50-348/97-08 & 50-364/97-08 on 970622-0802. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19970061997-07-18018 July 1997 Insp Repts 50-348/97-06 & 50-364/97-06 on 970511-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148K6511997-06-0909 June 1997 Insp Repts 50-348/97-05 & 50-364/97-05 on 970330-0510. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19972011997-05-13013 May 1997 Insp Repts 50-348/97-201 & 50-364/97-201 on 970127-0314.No Violations Noted.Major Areas Inspected:Engineering, Auxiliary Feedwater Sys,Component Cooling Water Sys & Sys Interface Design Review ML20138J6661997-04-28028 April 1997 Insp Repts 50-348/97-03 & 50-364/97-03 on 970216-0329. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support,Including Health Physics ML20137U6021997-04-0202 April 1997 Insp Repts 50-348/97-04 & 50-364/97-04 on 970125-0314. Violations Noted.Major Areas Inspected:Detailed Esfs Review & Walkdown of Units 1 & 2 PRF Sys,Including Associated Surveillance Test & Sys Design Requirements ML20140B7921997-03-17017 March 1997 Insp Repts 50-348/97-01 & 50-364/97-01 on 970104-0215. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19960151997-02-0303 February 1997 Insp Repts 50-348/96-15 & 50-364/96-15 on 961124-970104.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134G3961997-01-24024 January 1997 Insp Repts 50-348/96-14 & 50-364/96-14 on 961209-13.No Violations Noted.Major Areas Inspected:Biennial Emergency Preparedness Exercise ML20133F6921996-12-23023 December 1996 Insp Repts 50-348/96-13 & 50-364/96-13 on 961013-1123. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134J4391996-11-0808 November 1996 Insp Repts 50-348/96-09 & 50-364/96-09 on 960901-1012. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19960111996-10-11011 October 1996 Insp Repts 50-348/96-11 & 50-364/96-11 on 961007-11.No Violations Noted.Major Areas Inspected:Plant Support ML20128J9761996-09-27027 September 1996 Insp Repts 50-348/96-07 & 50-364/96-07 on 960721-0831. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support ML20128H8371996-09-27027 September 1996 Insp Repts 50-348/96-10 & 50-364/96-10 on 960812-16 & 26-30. Violations Noted.Major Areas Inspected:Radiation Monitoring Sys Radwaste Processing & Storage & Operational Radiation Protection Programs IR 05000348/19930301994-01-0606 January 1994 Insp Repts 50-348/93-30 & 50-364/93-30 on 931206-1210.No Violations or Deviations Noted.Major Areas Inspected: Process & Effluent Monitors,Post Accident Sampling Sys, Annual Radiological Environmental Operating Rept IR 05000348/19930291994-01-0505 January 1994 Insp Repts 50-348/93-29 & 50-364/93-29 on 931206-10.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Annual Emergency Preparedness Exercise IR 05000348/19930281993-12-14014 December 1993 Insp Repts 50-348/93-28 & 50-364/93-28 on 931022-1122. Noncited Violation Identified.Major Areas Inspected:Licensee Operations,Maint/Surveillance Activities & Unit 2 Refueling Activities IR 05000348/19930251993-12-0202 December 1993 Insp Repts 50-348/93-25 & 50-364/93-25 on 931018-22 & 931101-05.Noncited Violation Identified.Major Areas Inspected:Sg Tubes,Review Laser Welding Procedures to Be Used for Securing Sleeves & Review Design Changes IR 05000348/19930271993-11-24024 November 1993 Insp Repts 50-348/93-27 & 50-364/93-27 on 931025-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Actions for safety-significant Findings Identified During Electrical Distribution Sys Functional Insp IR 05000348/19930221993-11-17017 November 1993 Insp Repts 50-348/93-22 & 50-364/93-22 on 930925-1022.No Violations Noted.Major Areas Inspected:Maintenance, Surveillance,Industry Technical Issues,Event Repts,Unit 2 Refueling Activities & Continuing Review of self-assessment IR 05000364/19934001993-11-10010 November 1993 Insp Rept 50-364/93-400 on 931004-15.No Violations Noted. Majors Areas Inspected:Review of Licensee ISI Program Submittal & Nondestructive Exams of safety-related Weldments,Hanger & Supports Selected from SI IR 05000348/19930231993-11-10010 November 1993 Insp Repts 50-348/93-23 & 50-364/93-23 on 931012-15.No Violations Noted.Major Areas Inspected:Organization & Mgt Controls,Audits & Appraisals,External & Internal Control, Control of Radioactive Matl & Contamination IR 05000348/19930261993-11-0404 November 1993 Insp Repts 50-348/93-26 & 50-364/93-26 on Stated Dates. Violation Being Considered for Escalated Enforcement Action. Major Areas Inspected:Review of Plant Conditions Re Recent Listed Events IR 05000348/19930241993-11-0101 November 1993 Insp Repts 50-348/93-24 & 50-364/93-24 on 931012-15.No Violations or Deviations Noted.Major Areas Inspected:Isi, Including Nondestructive Exam Procedures & Observation of Work & Work Activities IR 05000348/19930211993-10-21021 October 1993 Insp Repts 50-348/93-21 & 50-364/93-21 on 930830-0925.No Violations Noted.Major Areas Inspected:Operations,Maint, Surveillance,Industry Technical Issues,Event Repts,Unit 2 Refueling Activities & Licensee self-assessment ML20057E4981993-09-29029 September 1993 Insp Repts 50-348/93-13 & 50-364/93-13 on 930816-0903. Violations Noted.Major Areas Inspected:Sws 1999-09-02
[Table view] Category:UTILITY
MONTHYEARIR 05000348/19900281990-10-15015 October 1990 Insp Repts 50-348/90-28 & 50-364/90-28 on 900911-1012.No Violations Noted.Major Areas Inspected:Operational Safety Verification,Monthly Surveillance & Maint Observation,Info Meeting W/Local Officials & self-assessment Capability ML20059N3501990-09-14014 September 1990 Insp Repts 50-348/90-24 & 50-364/90-24 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Actions in Response to NRC Bulletin 88-004, Potential Safety- Related Pump Loss IR 05000348/19900201990-08-23023 August 1990 Insp Repts 50-348/90-20 & 50-364/90-20 on 900711-0810.No Violations Noted.Major Areas Inspected:Operational Safety Verification,Monthly Surveillance & Maint Observation,Esf Sys Walkdown & LERs IR 05000348/19900211990-07-30030 July 1990 Insp Repts 50-348/90-21 & 50-364/90-21 on 900709-13.No Violations or Deviations Noted.Major Areas Inspected:Areas of Local Leak Rate Testing & Review of Previous Insp Findings.Five Open Items Re Leak Rate Testing Closed IR 05000348/19900171990-07-10010 July 1990 Insp Repts 50-348/90-17 & 50-364/90-17 on 900618-22.No Violations or Deviations Noted.Major Areas Inspected: Radiological Liquid & Gaseous Effluent Processing & Releases & Radiological Environ Monitoring Programs IR 05000348/19900041990-02-20020 February 1990 Insp Repts 50-348/90-04 & 50-364/90-04 on 900129-0202.No Violations or Deviations Noted.Major Areas Inspected: Followup of Open Items & Review of Activities Re Defects in Unit 1 Steam Generator Tube IR 05000348/19890181989-09-0707 September 1989 Partially Withheld Insp Repts 50-348/89-18 & 50-364/89-18 on 890731-0804 (Ref 10CFR2.790(d) & 10CFR73.21).Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactor,Mgt Support,Security & Vital Area Barriers IR 05000348/19890191989-08-31031 August 1989 Insp Repts 50-348/89-19 & 50-364/89-19 on 890821-25.No Violations or Deviations Noted.Major Areas Inspected:Control Room Operator & Licensed Operator Requalification Training Programs Re How Tasks Analyzed & Objectives Derived IR 05000348/19890171989-08-24024 August 1989 Insp Repts 50-348/89-17 & 50-364/89-17 on 890724-28.No Violations or Deviations Noted.Major Areas Inspected:Design, Design Changes & Plant Mods.Administrative Procedures Weak in Description of Interfaces Between Plant Groups IR 05000348/19890161989-08-17017 August 1989 Insp Repts 50-348/89-16 & 50-364/89-16 on 890711-31.No Violations or Deviations Noted.Major Areas Inspected: Operational Safety Verification & Monthly Surveillance & Maint Observation.List of Backlog of Ungraded Exams Encl IR 05000348/19890101989-07-27027 July 1989 Insp Repts 50-348/89-10 & 50-364/89-10 on 890424-27 & 0508- 2.Violations Noted.Major Areas Inspected:Maint Program & Implementation IR 05000348/19890141989-07-26026 July 1989 Insp Repts 50-348/89-14 & 50-364/89-14 on 890611-0710.No Violations or Deviations Noted.Major Areas Inspected: Operational Safety Verification,Monthly Surveillance Observation,Operator Training,Work Schedule & LERs IR 05000348/19890121989-06-26026 June 1989 Insp Repts 50-348/89-12 & 50-364/89-12 on 890511-0610.No Violations or Deviations Noted.Major Areas Inspected: Operational Safety Verification,Monthly Surveillance Observation,Lers & Design Changes & Mods IR 05000348/19890131989-06-0505 June 1989 Insp Repts 50-348/89-13 & 50-364/89-13 on 890509-10. Violations Noted.Major Areas Inspected:Use of Contaminated Money to Catch Alleged Thief & Failure of Operator to Follow Procedural Requirements Re High Radiation Area ML20246B0261989-05-25025 May 1989 Insp Repts 50-348/89-11 & 50-364/89-11 on 890411-0510. Violations Noted.Major Areas Inspected:Operational Safety Verification,Monthly Surveillance Observation,Monthly Maint Observation,Lers & Unit 2 Startup from Refueling IR 05000348/19890081989-05-11011 May 1989 Insp Repts 50-348/89-08 & 50-364/89-08 on 890410-14.No Violations or Deviations Noted.Major Areas Inspected:Areas of Occupational Exposure,Shipping,Transportation,Solid Waste & Licensee Responses to Info Notices IR 05000348/19890091989-04-24024 April 1989 Insp Repts 50-348/89-09 & 50-364/89-09 on 890410-14.No Violations or Deviations Noted.Major Areas Inspected: Inservice Insp,Including Eddy Current Exam of Unit 2 Steam Generator Tubing & NDE Procedures IR 05000348/19890071989-04-19019 April 1989 Insp Repts 50-348/89-07 & 50-364/89-07 on 890311-0410. Violations Noted.Major Areas Inspected:Review of Operational Safety Verification,Monthly Surveillance Observation,Monthly Maint Observation,Design Changes & Mods & Insp of DHR IR 05000348/19890061989-03-23023 March 1989 Insp Repts 50-348/89-06 & 50-364/89-06 on 890227-0303.No Violations or Deviations Noted.Major Areas Inspected: Radiological Effluent Monitoring,Liquid & Gaseous Radwaste, Plant Chemistry & Plant Radiochemistry ML20236D1301989-03-10010 March 1989 Partically Withheld Insp Repts 50-348/89-03 & 50-364/89-03 on 890123-27 (Ref 10CFR73.21).Violation Noted:Vital Area Door Not Secured as Required in Physical Security Plan IR 05000348/19890031989-03-10010 March 1989 Partically Withheld Insp Repts 50-348/89-03 & 50-364/89-03 on 890123-27 (Ref 10CFR73.21).Violation Noted:Vital Area Door Not Secured as Required in Physical Security Plan IR 05000348/19890011989-03-10010 March 1989 Insp Repts 50-348/89-01 & 50-364/89-01 on 890206-10.No Violations or Deviations Noted.Major Areas Inspected: Emergency Preparedness,Including Emergency Plan & Implementing Procedures & Emergency Facilities & Equipment ML20236E2131989-03-0808 March 1989 Insp Repts 50-348/89-04 & 50-364/89-04 on 890206-10. Violation Noted.Major Areas Inspected:Radiation Protection Preparation for Unit 2 Refueling Outage Scheduled for 890324-0426 & Response to Info Notices IR 05000348/19890021989-02-24024 February 1989 Insp Repts 50-348/89-02 & 50-364/89-02 on 890111-0210. Violation Noted.Major Areas Inspected:Operational Safety Verification,Monthly Surveillance Observation,Monthly Maint Observation,Drawing Sys Verification & LERs IR 05000348/19880291988-11-23023 November 1988 Insp Repts 50-348/88-29 & 50-364/88-29 on 881011-1110.No Violations or Deviations Noted.Major Areas Inspected:Review of Operational Safety Verification,Monthly Surveillance Observation,Info Meeting W/Officials & Emergency Exercise IR 05000348/19880271988-10-28028 October 1988 Insp Repts 50-348/88-27 & 50-364/88-27 on 880926-30. Unresolved Item Noted.Major Areas Inspected:App R Compliance & post-fire Safe Shutdown Capability,Including Plant Mod Review & Reverification of App R Fire Protection Features IR 05000348/19880251988-10-12012 October 1988 Partially Withheld Insp Repts 50-348/88-25 & 50-364/88-25 on 880822-26 (Ref 10CFR2.790 & 73.21).Major Areas Inspected: Security Plan & Implementing Procedures,Mgt Effectiveness, Security Organization,Records & Repts & Testing & Maint IR 05000348/19880261988-09-26026 September 1988 Insp Repts 50-348/88-26 & 50-364/88-36 on 880811-0910. Violations Noted.Major Areas Inspected:Operational Safety Verification,Monthly Surveillance Observation,Engineered Safety Sys Insp & Previous Insp Findings IR 05000348/19880241988-08-19019 August 1988 Insp Repts 50-348/88-24 & 50-364/88-24 on 880711-0810. Violations Noted:Use of Inadequate Procedure to Calculate RCS Inventory Leakage.Major Areas Inspected:Monthly Maint & Surveillance Observations & LERs IR 05000348/19880191988-08-17017 August 1988 Revised Pages 8-12 to Insp Repts 50-348/88-19 & 50-364/88-19 Correcting Grammatical Errors & Incorrect Paragraphs ML20151L5841988-07-21021 July 1988 Insp Repts 50-348/88-23 & 50-364/88-23 on 880611-0710. Violations Noted.Major Areas Inspected:Monthly Surveillance Observation,Operational Safety Verification,Engineered Safety Sys Insp,Radiological Protection & Physical Security ML20151D6531988-07-0707 July 1988 Insp Repts 50-348/88-19 & 50-364/88-19 on 880511-0610.No Violations Noted.Major Areas Inspected:Review of Monthly Surveillance & Monthly Maint Observation,Operational Safety Verification & Physical Security Program IR 05000348/19880221988-07-0606 July 1988 Partially Withheld Insp Repts 50-348/88-22 & 50-364/88-22 on 880613-17 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Vital Area Barriers, Assessment Aids & Access Control of Personnel ML20150C1281988-06-23023 June 1988 Insp Repts 50-348/88-20 & 50-364/88-20 on 880516-0610. Violation Noted.Major Areas inspected:post-refueling Startup Tests,Review of Completed Core Surveillance Procedures & Licensee Related Procedures IR 05000348/19880161988-06-0808 June 1988 Errata to Insp Repts 50-348/88-16 & 50-364/88-16 Revising App a to Correct Refs to Asco Solenoid Valves & Valve Numbers IR 05000348/19880181988-06-0202 June 1988 Insp Repts 50-348/88-18 & 50-364/88-18 on 880509-13.No Violations or Deviations Noted.Major Areas Inspected: Containment Tendon Surveillance Program,Snubber Surveillance Program,Ie Info Notice 85-045 IR 05000348/19880171988-05-26026 May 1988 Insp Repts 50-348/88-17 & 50-364/88-17 on 880502-06.No Violations or Deviations Noted.Major Areas Inspected: Inservice Insp Program Activities Associated W/Requested Relief from ASME Code Requirements.Unresolved Item Noted IR 05000348/19880151988-05-25025 May 1988 Insp Repts 50-348/88-15 & 50-364/88-15 on 880411-0510.No Violations or Deviations Noted.Major Areas Inspected:Reviews Previous Enforcement Matters,Montly Surveillance Observation & Montly Maint Observation ML20154P6001988-05-19019 May 1988 Insp Repts 50-348/88-10 & 50-364/88-10 on 880328-0511. Violations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Effluent Monitoring & Followup on Unresolved Item ML20154P6241988-05-17017 May 1988 Insp Repts 50-348/88-16 & 50-364/88-16 on 880419-21.No Violations or Deviations Noted.Major Areas Inspected:Environ Qualification of Electrical Equipment & Followup of Unresolved Items IR 05000348/19880141988-05-11011 May 1988 Insp Repts 50-348/88-14 & 50-364/88-14 on 880411-15.No Violations or Deviations Noted.Major Areas Inspected:Unit 1 Inservice Insp Activities,Including Remote Ultrasonic Exam of Reactor Vessel Welds IR 05000348/19880051988-05-11011 May 1988 Insp Repts 50-348/88-05 & 50-364/88-05 on 880222-26 & 0307-11.Violations Noted.Major Areas Inspected:Evaluation of Effectiveness of Various Plant Groups Including Operations, Maint,Qa,Engineering & Training for Safe Plant Operation IR 05000348/19880131988-05-10010 May 1988 Insp Repts 50-348/88-13 & 50-364/88-13 on 880404-08. Deviation Noted.Major Areas Inspected:Fire Protection & Prevention IR 05000348/19880111988-04-22022 April 1988 Insp Repts 50-348/88-11 & 50-364/88-11 on 880328-31.No Violations or Deviations Noted.Major Areas Inspected: Documentation Review for Welding Activities & NDE Re Safety Injection Sys IR 05000348/19880081988-04-21021 April 1988 Insp Repts 50-348/88-08 & 50-364/88-08 on 880311-0410.No Violations or Deviations Noted.Major Areas Inspected:Review of Monthly Surveillance Observation,Monthly Maint Observation & Physical Security Program ML20151N8811988-04-13013 April 1988 Partially Withheld Insp Repts 50-348/88-09 & 50-364/88-09 on 880321-24 (Ref 10CFR2.790 & 73.21).Violation Noted.Major Areas Inspected:Security Organization,Records,Repts,Testing, Maint,Locks,Keys,Combinations & Physical Barriers IR 05000348/19880011988-03-31031 March 1988 Insp Repts 50-348/88-01 & 50-364/88-01 on 880104-07.No Violations or Deviations Noted.Major Areas Inspected: Allegations Re Facility ML20148M9511988-03-28028 March 1988 Insp Repts 50-348/88-07 & 50-364/88-07 on 880211-0310.No Violations or Deviations Noted.Major Areas Inspected:Review of Monthly Surveillance & Maint Observations,Radiological Protection Program & Physical Security Program ML20148E6271988-03-16016 March 1988 Insp Repts 50-348/88-06 & 50-364/88-06 on 880229-0304. Violations Noted.Major Areas Inspected:Operational Readiness of Site Emergency Preparedness Program & to Determine If Changes to Emergency Preparedness Meet NRC Requirements ML20148E3571988-03-0101 March 1988 Insp Repts 50-348/87-37 & 50-364/87-37 on 871216-18.Util Noted One Violation Re Employee Failure to Sign in on Radiation Work Permit.Major Areas Inspected:Followup on Allegations Pertaining to Radiation Protection Program 1990-09-14
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000348/19990051999-09-0202 September 1999 Insp Repts 50-348/99-05 & 50-364/99-05 on 990627-0807.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19990041999-07-26026 July 1999 Insp Repts 50-348/99-04 & 50-364/99-04 on 990516-0626.One Noncited Violation Identified.Major Areas Inspected: Operations,Maint,Engineering & Plant Support ML20210H1591999-07-23023 July 1999 Notice of Violation from Insp on 990308-10.Violation Noted: from Time of Receipt of Alarm Until Arrival at Three Different Vital Areas,Response Objective & Physical Security Plan Were Not Met IR 05000348/19990031999-06-10010 June 1999 Insp Repts 50-348/99-03 & 50-364/99-03 on 990404-0515.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19990021999-04-29029 April 1999 Insp Repts 50-348/99-02 & 50-364/99-02 on 990221-0403.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20205Q1721999-04-0606 April 1999 Partially Withheld Insp Repts 50-348/99-09 & 50-364/99-09 on 990308-10 (Ref 10CFR73.21).Non-cited Violation Identified. Major Areas Inspected:Area of Plant Support Re Physical Security Program for Power Reactors IR 05000348/19990011999-03-19019 March 1999 Insp Repts 50-348/99-01 & 50-364/99-01 on 990110-0220. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000348/19980081999-02-0202 February 1999 Insp Repts 50-348/98-08 & 50-364/98-08 on 981129-990109.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000348/19980141999-01-0808 January 1999 Partially Withheld Insp Repts 50-348/98-14 & 50-364/98-14 on 981207-10 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Procedures & Representative Records,Interviews with Personnel & Observations of Activities in Progress IR 05000348/19980071998-12-28028 December 1998 Insp Repts 50-348/98-07 & 50-364/98-07 on 981018-1128.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980061998-11-10010 November 1998 Insp Repts 50-348/98-06 & 50-364/98-06 on 980830-1017.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000348/19980101998-11-0303 November 1998 Insp Repts 50-348/98-10 & 50-364/98-10 on 980908-11.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise & Response in Control Room Simulator & Technical Support Ctr IR 05000348/19980051998-09-28028 September 1998 Insp Repts 50-348/98-05 & 50-364/98-05 on 980712-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19980041998-08-10010 August 1998 Insp Repts 50-348/98-04 & 50-364/98-04 on 980601-0711.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20236J6971998-07-0101 July 1998 Notice of Violation from Insp on 980412-0530.Violation Noted:Several Conditions Adverse to Quality Associated W/Cr Ventilation Sys Were Not Promptly Corrected.Conditions Inappropriately Closed Out Before Adequate C/As Completed ML20236J7021998-07-0101 July 1998 Insp Repts 50-348/98-03 & 50-364/98-03 on 980412-0530.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20236J8121998-06-29029 June 1998 SALP Repts 50-348/98-99 & 50-364/98-99 Covering Period 961124-980530 IR 05000348/19980091998-05-11011 May 1998 Special Insp Repts 50-348/98-09 & 50-364/98-09 on 980323-25. Violations Noted.Major Areas Inspected:Follow Up on OI Rept 2-97-011 Issued on 980209 Re Improper Weld Repair IR 05000348/19980021998-05-0808 May 1998 Insp Repts 50-348/98-02 & 50-364/98-02 on 980221-0411.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19983001998-04-0606 April 1998 NRC Operator Licensing Exam Repts 50-348/98-300 & 50-364/98-300 (Including Completed Tests) for Exams Administered on 980312-13.Concluded Candidates Performance on Written & JPM re-take Exams Satisfactory ML20217E5921998-03-23023 March 1998 Notice of Violation from Insp on 980111-0212.Violation Noted:While Performing Maint on 1A Centrifugal Charging Pump,Maint Personnel Violated Requirements of FNP-0-M-001, Rev 13 IR 05000348/19980011998-03-23023 March 1998 Insp Repts 50-348/98-01 & 50-364/98-01 on 980111-0221. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support PNO-II-98-013, on 980308,util Declared NOUE Due to High River Level & Subsequent Flooding.Licensee Established Constant Communications W/Early,Ga & Houston County,Al.Resident Inspectors Are Monitoring Licensee Activities1998-03-0909 March 1998 PNO-II-98-013:on 980308,util Declared NOUE Due to High River Level & Subsequent Flooding.Licensee Established Constant Communications W/Early,Ga & Houston County,Al.Resident Inspectors Are Monitoring Licensee Activities IR 05000348/19970151998-02-0909 February 1998 Insp Repts 50-348/97-15 & 50-364/97-15 on 971130-980110. No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20198N9961997-12-29029 December 1997 Insp Repts 50-348/97-14 & 50-364/97-14 on 971019-1129. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20198N9481997-12-29029 December 1997 Notice of Violation from Insp on 971019-1129.Violation Noted:As Early as June 1985,licensee Identified Degradation of Cork Seal Between Containment & Auxiliary Bldg Walls, Condition Adverse to Quality IR 05000348/19970131997-11-20020 November 1997 Partially Withheld Insp Repts 50-348/97-13 & 50-364/97-13 on 971021-24 (Ref 10CFR73.21).Major Areas Inspected:Physical Security Program for Power Reactors ML20199H1281997-11-17017 November 1997 Notice of Violation from Insp on 970907-1018.Violations Noted:Battery Capacity After Svc Test Was Inadequate & Check Valve V003 & V002D F & H Were Not Flow Tested in Manner That Proves That Disk Travels to Seat on Cessation ML20199H1541997-11-17017 November 1997 Insp Repts 50-348/97-11 & 50-364/97-11 on 970907-1018. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000348/19970071997-10-10010 October 1997 Insp Repts 50-348/97-07 & 50-364/97-07 on 970825-29.No Violations Noted.Major Areas Inspected:Licensee Corrective Action Program,Including Problem Identification & Resolution IR 05000348/19970101997-10-0606 October 1997 Insp Repts 50-348/97-10 & 50-364/97-10 on 970803-0906. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support ML20211Q9391997-10-0606 October 1997 Notice of Violation from Insp on 970803-0906.Violation Noted:As of 970906 Licensee Installed One 1-inch Thick Wrap of Kaowool on Sides & Bottoms of Raceways BDE-9 & BDE-15, Carrying Train B Charging Pump Power Cable in Fire Area IR 05000348/19970121997-09-26026 September 1997 Insp Repts 50-348/97-12 & 50-364/97-12 on 970818-22. Violations Noted.Major Areas Inspected:Review of Fire Protection Program Activities to Support Design Basis of Silicone Foam Fire Barrier Penetration Seals ML20211K8161997-09-26026 September 1997 Notice of Violation from Insp on 970818-22.Violation Noted: Noted:Nrc Identified That Licensee Failed to Correctly Translate Applicable Design Specfication Input Requirements for Kaowool Electrical Raceway Fire Barrier Sys at Plant IR 05000348/19970081997-08-28028 August 1997 Insp Repts 50-348/97-08 & 50-364/97-08 on 970622-0802. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20217R2021997-08-28028 August 1997 Notice of Violation from Insp on 970622-0802.Violation Noted:On 970616,most of M&TE Used Onsite Did Not Have Written & Approved Calibration Procedures PNO-II-97-039A, on 970720,Hurricane Danny Downgraded to Depression.Storm Disipated Without Reaching Farley Nuclear Plant.Farley Nuclear Plant Experienced Light Rain W/Both Units Remaining at Full Power1997-07-21021 July 1997 PNO-II-97-039A:on 970720,Hurricane Danny Downgraded to Depression.Storm Disipated Without Reaching Farley Nuclear Plant.Farley Nuclear Plant Experienced Light Rain W/Both Units Remaining at Full Power PNO-II-97-039, on 970718,response Was Made to Hurricane Danny.Region II State Liason Officer Has Been in Contact W/Fema & State of Al.Plant Staff Taking Precautionary Measures in Preparation for High Wind Conditions1997-07-18018 July 1997 PNO-II-97-039:on 970718,response Was Made to Hurricane Danny.Region II State Liason Officer Has Been in Contact W/Fema & State of Al.Plant Staff Taking Precautionary Measures in Preparation for High Wind Conditions IR 05000348/19970061997-07-18018 July 1997 Insp Repts 50-348/97-06 & 50-364/97-06 on 970511-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148K6431997-06-0909 June 1997 Notice of Violation from Insp on 970330-0510.Violation Noted:On 970321,facility Licensee Physician Determined That Licensed Operator Eyesight No Longer Met Min Stds Required by 10CFR55.33(a)(1) as Measured by Std of ANSI/ANS-3.4-1983 ML20148K6511997-06-0909 June 1997 Insp Repts 50-348/97-05 & 50-364/97-05 on 970330-0510. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000348/19972011997-05-13013 May 1997 Insp Repts 50-348/97-201 & 50-364/97-201 on 970127-0314.No Violations Noted.Major Areas Inspected:Engineering, Auxiliary Feedwater Sys,Component Cooling Water Sys & Sys Interface Design Review ML20196G4241997-05-0606 May 1997 Notice of Violation from Insp Completed on 970314.Violation Noted:Prior to 970314,licensee Failed to Prescribe Documented Instructions or Procedures to Implement Listed Activities Affecting Quality of Operation of PRF Sys ML20138J6661997-04-28028 April 1997 Insp Repts 50-348/97-03 & 50-364/97-03 on 970216-0329. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support,Including Health Physics IR 05000348/19973001997-04-22022 April 1997 Exam Repts 50-348/97-300 & 50-364/97-300 on 970324-27.Exam Results:Two of 5 Applicants Passed Exam.One Was Grades as Marginal Pass ML20137U6021997-04-0202 April 1997 Insp Repts 50-348/97-04 & 50-364/97-04 on 970125-0314. Violations Noted.Major Areas Inspected:Detailed Esfs Review & Walkdown of Units 1 & 2 PRF Sys,Including Associated Surveillance Test & Sys Design Requirements ML20140B7851997-03-17017 March 1997 Notice of Violation from Insp on 970105-0215.Violation Noted:Test Engineer Failed to Comply W/Procedural Requirements of FNP-1-STP-124.0 During Performance Testing of Plant Penetration Room Filtration Sys Train a ML20140B7921997-03-17017 March 1997 Insp Repts 50-348/97-01 & 50-364/97-01 on 970104-0215. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000348/19960151997-02-0303 February 1997 Insp Repts 50-348/96-15 & 50-364/96-15 on 961124-970104.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134G3961997-01-24024 January 1997 Insp Repts 50-348/96-14 & 50-364/96-14 on 961209-13.No Violations Noted.Major Areas Inspected:Biennial Emergency Preparedness Exercise 1999-09-02
[Table view] |
See also: IR 05000348/1987037
Text
H.
,
,8
[e '
, o NUCLEAR REGULATORY COMMISSION
REGION il
4-
[.n 101 MARIETTA STREET, N.W.
/9 j
, .
..... MAR 161988
i
i
Report Nos.: 50-348/87-37 and 50-364/87-37
Licensee: Alabama Power. Company
600 North ~18th Street
Birmingham, AL 35291-0400
Docket Nos.: 50-348 and 50-364 License Nos.: NPF-2 and NPF-8 '
Facility Name: Farley
Inspection Conducted:,-D ember 16-18,-1987
Inspector: , a 8 #7
T.~ R. Collins Da~te Signed
Approved by: /!
'
C.M.Hosey,JSectionghief
. Date Signed
Division of Radiation Safety and Safeguards
SUMMARY
Scope: This special, announced inspection was conducted to followup on
allegations regarding the radiation protection program.
Results: One licensee identified violation for failure cf a licensee employee :'
to sign in on a Radiation Work Permit (RWP).
,
I
t
,
8803250071 880316 '
PDR ADOCK 05000348
o DCD
_ _ _ _ - - - _ _ . _ _ _ _ _.
J
- t .. ,
. .
t
'
REPORT DETAILS
-
1. Persons Contacted
Licensee Employees
R. Bayne, Chemistry Supervisor
D. Grissett, Emergency Planning Supervisor
M. Mitchell, Health Physics and Radwaste Supervisor
- 0. Morey, Assistant General Manager
- C, Nesbitt, Technical Superintendent
B. Patton, Plant Health Physicist
J. Woodard, General Manager
l
Other licensee employees contacted included construction craftsmen,
engineers, technicians, operators, mechanics, security office members, and !
office personnel.
,
Nuclear Regulatory Commission
- W. H. Bradford, Senior Resident Inspector
2. Exit Interview
The inspection scope and findings were summarized on December 18, 1987,
' The inspector
with thote persons indicated in Paragraph I above.
described the areas inspected and discussed in detail the licensee
identified violation (Paragraph 4.g). No dissenting comments were
received from the licensee. Proprietary information is not contained in
this report.
'I
3. Licensee Action on Previous Enforcement Matters
'
This subject was not addressed in the inspection.
4. Followup on Allegations (99014)
,
a. Allegation (2850058271)
A lower level manager was not qualified for his assigned position.
Discussion and Finding
i
. The inspector discussed with licensee management representatives the
'
knowledge and qualifications of the individual in question. The
,
inspector reviewed the individual's training records and resume and
, determined that the lower level manager had a Bachelor of Science i
degree and five years expr.rience in his specialty, which met the l
.- ., . ,. - - . . - . .- - - - , - - . - . . _ _ . - . , - - . - . - . - - - - - . - - ,
' '
.
,
, ,
2
requirements of ANSI N18.1, 1971, Section 4.3.2 as required by
Technical Specification 6.3, Facility Staff Qualifications.
Conclusion
This allegation was not substantiated,
b. Allegation (2850058254)
A hydrogen explosion occurred in the Unit 1 Turbine / Generator which
contaminated the hydrogen system. Smears of a vendor's truck and
couplings snowed contamination above acceptable levels. Alleger
wanted to notify the vendor but was overruled. Report of this
incident which occurred in February 1982, omitted smear results
showing contamination levels.
Discussion and Finding
The inspector discussed this event with licensee management
representatives and determined that an event similar to the
allegation had occurred in September 1981. Rather than a hydrogen
explosion an electrical fault (arc) had occurred on the Unit 1 Main
Generator which resulted in shutting down Unit 1. Unit I remained
shut down and was in a refueling outage between September 1981 and
March 1982. The inspector reviewed the incident report issued by the
licensee which included radiological survey results of the Unit 1
Main Senerator/ Turbine arc incident. The inspector selectively
reviewed the radiological survey results of the Unit 1 Main
Generator / Turbine, Hydrogen System and the vendor truck and concluded
that radioactive contamination levels were well below action
guidelines as established by radiation control procedures,
< 1,000 dpm/100 cm2 beta / gamma and < 100 dpm/100 cm2 alpha. Unit 2
began a routine outage early as the result of the electrical fault.
Survey records that were reviewed did not appear to be changed or
altered in any way.
Conclusion
This allegation was partially substantiated in that an electrical
fault had occurred on the Unit 1 Main Generator which resulted in
shutting down Unit 1. Although surveys of the Main Generator were
performed by the licensee, the likelihood of the generator being
contaminated is remote. No contaminated system makes direct contact
with the Main Generator. However, no violations or deviations of
regulatory requirements were identified.
c. Allegation (2850058263)
Smears of the reactor cavity indicated that thousands of counts per
minute (cpm) alpha was detected using a scintillation alpha probe.
Smears of reactor cavity walls taken by the alleger indicated alpha
_ _ _ _ _ - _ _ _ - _ _ _ _ _ _ _ _
.. ,.
,
. .
3
contamination levels up to 400 dpm/100 cm 2
. Alleger reported this
j result in the survey but the survey was changed.
Discussion and-Finding
The inspector discussed this issue with licensee management
representatives and HP technicians and determined through review of
contamination survey records performed during 1982 and 1983 that only
trace amounts of alpha contamination were detected. The area where
alpha activity was most significant was the reactor cavity and spent
fuel pool area. Survey results revealed that alpha contamination was
2,000 to 8,000 dpm/100 cm 2 . However, the beta / gamma activity from
these same smears indicated 2.0 X 10' to 3.0 X 10' dpm/100 cm 2 . With
extreme high beta / gamma activity, up to 5% of the beta / gamma value
could be recorded as alpha _ radioactivity when counting alpha and beta
particles simultaneously using an alpha / beta counting system. This
results when a percentage of the beta particles are counted in the
alpha energy window. The licensee cut up these smears to reduce the
interference from beta / gamma activity with the alpha activity and
after counting the individual sections of the smears in aggregate
using a beta / gamma and alpha proportional counters, alpha
contamination levels were found to be non-detectable. The inspector
also concluded after review of survey records that no changes
appeared to have been made to the alpha survey results. Therefore,
the inspector could not prove or disprove that changes were made on
the survey records.
Conclusion
This allegation was partially substantiated in that alpha
contamination appeared to be present on extremely high beta / gamma
radioactivity smears. However, analysis performed by the licensee
demonstrated that the alpha contamination levels were below licensee
action levels. No violations or deviations of regulatory
requirements were identified.
'
- d. Allegation (2850058162)
'
During plant operations with failed fuel, the alleger felt he
'
received a high extremity dose. Alleger also stated that the
licensee operated for a long time without extremity TLDs.
Discussion and Findings
!
The inspector discussed this issue with licensee management
representatives and Chemistry technicians and concluded after
i interviews with selected individuals (Health Physics and Chemistry
j personnel) and review of radiological survey's and radiation work
permits (RWPs) for the period of 1982 and 1983, that personnel
required to take reactor coolant samples (RCS) were issued extremity
l
dosimetry. The inspector reviewed the alleger's dosimetry records
i
!
.-
,
4
and determined that extremity TLD's had been issued when required and
the results were well within 10 CFR 20.101 limits. The inspector
reviewed the licensee's program for issuance of extremity TLDs and
determined that since 1982 and 1983 and presently the limit for
issuing extremity dosimetry has been that the extremity dose rate is
> 6 times the anticipated whole body dose rate.
Conclusion
This allegation was not substantiated.
e. Allegation (2850058033, 2850058051, 2850058179, 2850058305)
A vendor company identified a problem with the accuracy of the whole
body counter.
A contract technician indicated that whole body counter coefficients
were badly off.
A vendor identified problems with the whole body counter.
A vendor found a large discrepancy between the vendor's whole body
counter and the licensee's.
Discussion and Finding
The inspector discussed these issues with licensee management
representatives and dosimetry personnel. After interview of selected
individuals (Chemistry Supervisors and Dosimetry personnel), review
of selected calibration records, whole body count (WBC) results, and
comparison of the licensee's WBC results and the vendor's WBC results
the inspector identified no discrepancies. The inspector also
reviewed the licensee's approved procedures both for the licensee's
and the vendor's whole body counters and concluded that these
procedures were adequate both for operation and calibration of the
whole body counters.
Conclusion
These allegations were not substantiated.
f. Allegation (2850058355)
A licensee employee had an internal deposition of xenon rather than
iodine.
Discussion and Finding
The inspector discussed this issue with HP Supervisory personnel and
was informed that no known incidents had occurred resulting in an
internal deposition for the individual in question. The individual
-
.
.
. .
5
was not available for interview, since he was no longer employed by
the licensee. The inspector reviewed the individuals dosimetry file
for internal exposure results, and concluded that for the individual
in question no positive internal exposures of iodine were received by-
the individual in question.
Conclusion
This allegation was not substantiated.
g. Allegation (2850058260, 2850058295)
Two licensee employees entered Unit 1 containment violated RWP
requirements and the Radiological Incident Reports (RIRs) were
destroyed.
Discussion and Findings
The inspector discussed these issues with licensee management
representatives and HP personnel and, for one of the above mentioned
licensee personnel, the inspector reviewed an RIR that was written on
February 8, 1982, for failure to sign in on an RWP for routine
inspection as required by Radiation Control Procedure FNP-RCP-002,
Section 6.1.7, prior to entering Unit 1 containment. The other issue
regarding failure to follow RWP requirements, the inspector concluded
after interviews with the individual in question and HP personnel (HP
supervisor and HP technicians), that apparently no RWP requirements
were violated, therefore, no RIR was required to be written.
Conclusion
These allegations were partially substantiated in that a licensee
employee entered Unit I containment for a routine inspection and
failed to sign in on the RWP prior to entry. The licensee properly
documented this event on a RIR as required by procedure. However,
since the NRC Enforcement Policy,10 CFR 2, Appendix C,1986, states
that a violation identified by the licensee will not be cited by the
NRC if (1) it was identified by the licensee; (2) it fits in Severity
Level IV or V; (3) it was reported if required; (4) it was or will be
corrected, including measures to prevent recurrence, within a
reasonable time; and (5) it was not a violation that could reasonably
be expected to have been prevented by the licensee's corrective
actions for a previous violation. The inspector concluded that this
apparent violation met the criteria specified in 10 CFR 2, Appendix C
and would be considered licensee identified (50-348, 364/88-02-01),
b. Allegation (2850058178, 2850058014)
A licensee employee had an excessive uptake of iodine in the lungs
and after a couple of showers the activity disappeared.
-
W
_ - _ _ _ _ _ _ _ - _ - - _ _ _ - _ _ - - _ _ _ _____ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _- _ _ _
u
-
.~ ,
. .
6
i
Discussion and Finding
The inspector discussed this issue with licensee management
4 representatives and HP personnel (supervisors and technicians). The
inspector concluded after review of the individuals dosimetry file
! and RIRs, that an event similar to the allegation had occurred and
the individual in question had received a potential _ intake of
radioactivity on March 10, 1983, while performing work on IB Reactor
Coolant Drain Tank (RCDT). Review of the Lincident and 'the
individuals WBC results indicated that the individual did not have
any skin contamination and his Maximum Permissible Body Burden (MPBB)
was < 10%. The isotopes included Cr-51, Fe-59,and Co-60. . Followup
WBCs revealed no detectable activity. The licensee documented this
event on an RIR as required by procedure and performed WBCs of the
individual to assess the intake of radioactivity.
Conclusion
This allegation was partially substantiated in that an event similar
to the allegation had occurred and after the individual had showered
prior to the WBC, the intake was assessed to be < 10% fiPBB internal
exposure, and was also below 10 CFR 20.103 limits. No violations or
deviations of regulatory requirements were identified,
i 1. Allegation (2850058193)
Alleger saw a licensee employee pull a rope from the reactor cavity
without a respirator as required by the RWP and therefore, became
contaminated.
l Discussion and Finding
The inspector discussed this event with licensee HP personnel
- (supervisors and technicians) and with the individual involved and
4 concluded tht.t the alleged event probably had occurred on January 13,
l
'
1982. The inspector determined that the individual had become
contaminated, while working inside Unit I containment, performing
decontamination inside the reactor cavity, but not from pulling a
-
'
rope out of the reactor cavity. Upon exiting containment, the
individual performed a whole body frisk and found increased activity
,
on his right shoulder. Survey results revealed 6,000 dpm/ probe area.
- Af ter discussion with HP personnel involved in the incident (HP
l supervisor and HP technicians) and review of selected respiratory
! issuance logs and interview of the individual involved, it was
. determined that the individual was issued and wore the required
l respiratory equipment while performing decontamination in the reactor
i cavity. The licensee determined that during decontamination the
j individual's plastic suit had separated exposing this area to high
- levels of contamination. The inspector reviewed the RIR written on
'
this event and concluded the licentre documented this incident as
l required.
!
!
m _ _ . . _ -. s_ _. _
'
i.I )~
.
..
.
c;
.
y {.p
J h., g
-
o
,z s .-
7 h,' y.
Is,
t
x 4
- -
Conclusion U
i
This allegation was partially substantiated in. that the individual in r
question .did become contaminated while performing work inside Unit I
reactor cavity, but not from pulling a rope out of the reactor cavity
~
without a respirf ter. No violations or deviations of regulatory '
]- requirements war,e identified. j
,
J. Allegation (2850058282)
First aid kits and equipment in the first aid station in the
Auxiliary Building, Nurse's Station in the Training Facility, and the-
Plant Emergency Vehicle (PEV) were either missing or in need of
repair. Also, the PEV did not contain a trauma kit and the patients
compartment was tot kept orderly as required.
Discussion and Finding
The inspector discussed these issues with licensee representatives
- (Emergency Planning (EP) Supervisor and EP Technicians). The
a inspector determined,through review of quarterly inventory records as
required by administrative control procedure, FNP-0-SHP-52, for 1982,
1983, and 1987 and through tours and observation of these facilities,
that the .first aid stations had the required first aid kits and
'
trauma kit.in the PEV. The inspector also determined by observation
that the first aid kits and PEV were well maintained as required by
administrative control procedures,
,
Conclusion
Thisallegationpasnotsubstantiated.
'
! 5. Radiological Surveys '
' '
Is
The inspector requetted the licensee to perform smear surveys of selected
areas within the radiolugical controlled area (RCA) and analyze them for
alpha, beta, and, gamma radioactivity. The inspector observed the
,
performance of tha surveys. Surveys were taken in the Unit 1 Spent Fuel
'
Pool Area, Waste Sorting Area, Unit 1 Primary Sample Room, and the
i Radwaste Solidification Area.
I The inspector informed licensee management representatives that these
smecr samples (approximately 213) would be analyzed by the NRC Region II
office and the results reported to the licensee.
i-
4
'w--
-.