Forwards Safety Evaluation Re IGSCC Insp & Repair for Facility Reload 8,Cycle 9 Refuel Outage Based on Review of Submittals
ML20059K423
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 09/13/1990
From: Labarge D
Office of Nuclear Reactor Regulation
To: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
Shared Package
ML20059K431 List:
References
TAC-69162, NUDOCS 9009210296
Download: ML20059K423 (3)


Text

. _ _ _

[,I ." September' 13, :1990 y .

Docket No. 50-333 Distribtuions:

L c5eoE741E $* OGC l L NRC & Local PDRs E.Jordon '

PDi 1-1 Reading 'ACRS(10) u SYarga JLinville>

l. RWessman WKoo (

. CYogan DLaBarge  :

L RCapra .

Plant file <

Mr. John C. Brons '

Executive Vice President - Nuclear Generation -

Power Authority of the State of New York 123 Main Street White. Plains, New York 10601

Dear Mr. Brons:

't

SUBJECT:

REVIEW 0F INTERGRANULAR STRESS CORROSION CRACKING-INSPECTION AND- 1 REPAIR FOR THE JAMES A.- FITZPATRICK NUCLEAR POW" DLANT. - J RELOAD 8/ CYCLE 9 REFUEL OUTAGE (TAC NO. 69162)

By letters dated November 10, 1988 (JPN-88-061 and JPN-88-062), Mare a , 1989 .l (JPN-89-012),andJanuary 29 1990 (JPN-90-012), you submitted -the results of t the inspections and repairs performed during the~ Reload 8/ Cycle 9; Refueling.

Outage at the James A. FitzParick Nuclear Power Plant.  ;

As described in'our letter of November 18, 1988, we have reviewed these.

submittals and concluded that the inspections and repairs performed during the outage are acceptable for plant operation during Cycle 9. Enclosed is the safety evaluation which documents the basis for this conclusion.

In addition, the staff has evaluated your submittal dated August 19, 1988 1 (JPN-88-043) regarding application of the resistance heating stress improvement (RHSI) process to two recirculation piping welds for IGSCC mitigation. The . t staff's evaluation and conclusion regarding~this issue is also included in the 1 enclosed safety evaluation.

This action closes TAC No. 69162.

Sincerely, ,

- ORIGINAL $1GNED BY Dav'id E. LaBarge, Project Manager-
3' Project Directorate I-I Division of Reactor Project - I/II g Office of Nuclear Reactor Regulation nn3

- n.

Enclosure:

As stated O26..4 .<

O' O

,o g cc w/ enclosure:

,g-See next page oi5 p sc4 l

. jg4 PD1-1jg PDI-1 PD1-1 L o CV0GAN DLABARGE:Av1 RACAPRA' 88 'l- Ic 'It 9po/10 y ajc;o

' & c. o -

~ DOCUMENT NAME: FITZ RAI 69162

-D Fo (

.. .. .. - ~ - . - - -... - . - .- - -.. .-

i. 1 . *-

l* g UNITED STATE:

[ NUCLEAR REGULATORY COMMISSION

,. $ WASHINGTON, D. C. 30005 k.... .

September 13 1990  !

Decket No. 50-333 j Mr. John C. Brons .

Executive Vice President.- Nuclear Generation Power Authority of the State of New York <

123 Main Street

~ White Plains, New York 10601

Dear Mr. Brons:

SUBJECT:

REVIEW OF.INTERGRANULAR STRESS CORROSION CRACKING INSPECTION AND 1 REPAIR FOR THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

RELOAD 8/ CYCLE 9REFUELOUTAGE(TACNO.69162)

By letters dated November 10,1988(JPN-88-061andJPN-88-062), March 24,1989L (JPN-89-012), and January 29,1990 (JPN-90-012),.you submitted the results of ,

the inspections and repairs performed during the Reload 8/ Cycle 9 Refueling Outage at the' James A. FitzParick Nuclear Power Plant.

As described in our letter of November 18, 1988, we:have reviewed these [

submittals and concluded that the inspections and repairs performed during the outage are acceptable for plant operation during Cycle 9. Enclosed is.the '

safety evaluation which documents the basis for this conclusion.

In addition, the staff has evaluated your sulmittal dated August.19,1988 (

(JPN-88-043)regardingapplicationoftheresistanceheatingstressimprovement IPF.I) process to two recirculatior piping welds for IGSCC mitigation._ The' steff's evaluation and conclusion regarding this issue is also included-in the'.

enclosed safety evaluation.

This action closes TAC No. 69162.

' Sin'cerely, f .

David E. LaBarge, Project Manager Project Directorate I-I Division of Reactor Project -il/II-Office of Nuclear Reactor Regulation >

Enclosure:

As stated cc w/ enclosure:

See next page l

" ' 1 Nr John C. Brons James A. FitzPatrick Nuclear

'Powsr' Authority of the State of New York - Power Plant cc: -

Mr. Gerald C. Goldstein Ms. Donna Ross l Assistant General Counsel New York State Energy Office Power Authority of the State 2 Empire State Plaza of New York 16th Floor 1633 Broadway Albany, New York 12223-New York, New York 10019 Resident Inspector.'s Office Pegional Administrator, Region I U. S. Nuclear Regulatory Commission U. S. Nuclear Regulatory Commission Post Office Box 136 a75 Allendale Road' Lycoming, New York 13093 King of Prussia, Pennsylvania 19406 Mr. William Fernandez Mr. A. Klausman Resident Manager Senior Vice President - Appraisal James A. FitzPatrick !!uclear and Compliance Services Power Plant Power Authority of the State Post Office Fox 41 of New York Lycoming, New York 13093 1633 Broadway  !

New York, New York 10019  :

tir. J. A. Gray, Jr. Mr. George Wilverding, Manager Director t!uclear Licensing - BWR Nuclear Safety Evaluation Power Authority of the State Power Authority of the State of New York of New York 123 Main Street 123 Main Street ..

White Plains,'New York 10601 White Plains, New York 10601-Supervisor Mr R. E. Beedle Town of Scriba Vice President Nuclear Support R. D. #4 Power Authority,of the State Oswego, New York 13126 of New York 123 Main Street Mr. J. P. 'Bayne, President '

Power Authority of the State of New York Mr. S. S. Zulla 1633 Broadway Vice President Nuclear. Engineering New York, New York 10019 Power Authority of the State of New York-

' 123 Main Street Mr. Richard Patch White Plains, New York 10601 Quality Assurance Superintendent James A. FitzPatrick Nuclear Power Plant Post Office Box 41 Mr. William Josiger, Vice President Lycoming, New York 13093 Operations and Maintenance Power Authority of the State of New York 123 Main Street Charlie Donaldson, Esquire White Plains, New York 10601 Assistant Attorney General flew York Department of Law heh k

  • k w York 10271