ML20236P658: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 14: Line 14:
| document type = CORRESPONDENCE-LETTERS, NRC TO UTILITY, OUTGOING CORRESPONDENCE
| document type = CORRESPONDENCE-LETTERS, NRC TO UTILITY, OUTGOING CORRESPONDENCE
| page count = 2
| page count = 2
| project = TAC:64756
| stage = Approval
}}
}}



Latest revision as of 02:25, 20 March 2021

Forwards Amend 133 to License NPF-1 & Safety Evaluation. Amend Revises Steam Generator Tube Plugging Criteria Based on Use of F* Distance Criteria
ML20236P658
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 08/07/1987
From: Chan T
Office of Nuclear Reactor Regulation
To: Cockfield D
PORTLAND GENERAL ELECTRIC CO.
Shared Package
ML20236P660 List:
References
TAC-64756, NUDOCS 8708120459
Download: ML20236P658 (2)


Text

_ _ _ . - - - _ _ _ - _ __

August 7,1987 Docket No.: 50-344 DISTRIBUTION

<DocketaFile? WJones NRC & Local PDRs EButcher GMHolahan ACRS (10)

Mr. David W. Cockfield JLee GPA/PA Vice President, Nuclear TChan ARM /LFMB Portland Genera 1' Electric Company OGC-Bethesda PD5 Plant File 121 S.W. Salmon Street DHagan Portland, Oregon 97204 EJordan JPartlow

Dear Mr. Cockfield:

TBarnhart(4) ,

SUBJECT:

ISSUANCE OF' AMENDMENT N0.133 TO FACILITY OPERATING LICENSE NO. NPF-1, TROJAN NUCLEAR PLANT (TAC N0. 64756)

The Commission has issued 'the enclosed Amendment No.133 to Facility Operating License No. NPF-1 for the Trojan Nuclear Plant. The amendment consists of changes to the Technical Specifications in response to your application-(LCA 152) dated February 20, 1987, as revised April 20, 1987.

The amendment revises the steam generator tube plugging criteria, based upon the use of the F* distance criteria.

A copy.of the related Safety Evaluation is also enclosed. The notice of issuance will be included in the Commission's next regular bi-weekly Federal Register notice.

Sincerely, Originsi signed by Terence L. Chan, Project Manager Project Directorate V v

Di~ision of Reactor Projects - III, IV, V and Special Projects

Enclosures:

1. - Amendment No.133 to NPF-1
2. Safety Evaluation cc w/ enclosures:

.See next page i

  • See pre'vious concurrence
  • DRSP/PD5
  • DRSP/PD5 *0GC DRS 205 JLee TChan GWK ton 7/ 1 /87 7/ 13 /87 7/ 14 /87 f/ /87 0FFICIAL RECORD COPY P

P

Mr. David W. Cockfield Portlant' General Electric Company Trojan Nuclear Plant cc:

Senior Resident Inspector U.S. Nuclear Regulatory Commission Trojan Nuclear Plant Post Office Box 0 Rainier, Oregon 97048 Michael J. Sykes, Chairman Board of County Commissioners Columbia County St. Helens, Oregon 97501 Mr. David Kish Oregon Department of Energy Labor and Industries Building Room 111 Salem, Oregon 97310 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596

________-_______w