IR 05000395/1987013
ML20214P373 | |
Person / Time | |
---|---|
Site: | Summer |
Issue date: | 05/21/1987 |
From: | Mcalpine E, Todd G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
To: | |
Shared Package | |
ML20214P361 | List: |
References | |
50-395-87-13, NUDOCS 8706030342 | |
Download: ML20214P373 (4) | |
Similar Documents at Summer | |
---|---|
Category:INSPECTION REPORT
MONTHYEARIR 05000395/19990061999-10-0808 October 1999
[Table view]Insp Rept 50-395/99-06 on 990801-0911.One Violation Identified & Being Treated as Ncv.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000395/19990051999-08-30030 August 1999 Insp Rept 50-395/99-05 on 990620-0731.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990041999-07-16016 July 1999 Insp Rept 50-395/99-04 on 990509-0619.Noncited Violation Identified.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering & Plant Support ML20207H5331999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990031999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990021999-04-26026 April 1999 Insp Rept 50-395/99-02 on 990214-0327.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990011999-03-15015 March 1999 Insp Rept 50-395/99-01 on 990103-0213.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980101999-02-0101 February 1999 Insp Rept 50-395/98-10 on 981122-990122.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980091998-12-21021 December 1998 Insp Rept 50-395/98-09 on 981011-1121.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980081998-11-0909 November 1998 Insp Rept 50-395/98-08 on 980906-1010.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980071998-10-0505 October 1998 Insp Rept 50-395/98-07 on 980726-0905.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980061998-09-24024 September 1998 Insp Rept 50-395/98-06 on 980628-0725.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980051998-07-27027 July 1998 Insp Rept 50-395/98-05 on 980517-0627.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980041998-06-15015 June 1998 Insp Rept 50-395/98-04 on 980405-0516.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980031998-05-29029 May 1998 Insp Rept 50-395/98-03 on 980330-0417.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C6681998-05-0404 May 1998 Insp Rept 50-395/98-02 on 980222-0404.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217G4651998-03-20020 March 1998 Insp Rept 50-395/98-01 on 980111-0221.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203J7531998-02-0909 February 1998 Insp Rept 50-395/97-14 on 971130-980110.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19970131997-12-23023 December 1997 Insp Rept 50-395/97-13 on 971019-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970121997-11-17017 November 1997 Insp Rept 50-395/97-12 on 970907-1018.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970111997-10-0202 October 1997 Insp Rept 50-395/97-11 on 970727-0906.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support ML20203L2831997-09-24024 September 1997 Insp Rept for VC Summer Nuclear Station on 970227.No Conditions Observed at Time of Insp That Could Be Considered Immediate Threat to Safety of Dams or Nuclear Facility.Major Areas Inspected:Service Water Pond Dams IR 05000395/19970101997-08-22022 August 1997 Insp Rept 50-395/97-10 on 970714-18.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise ML20210N9401997-08-21021 August 1997 Insp Rept 50-395/97-07 on 970615-0726.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970091997-08-11011 August 1997 Insp Rept 50-395/97-09 on 970707-11.No Violations Noted. Major Areas Inspected:Area of Plant Support by Two Regional Safeguards Inspectors IR 05000395/19970081997-08-0808 August 1997 Insp Rept 50-395/97-08 on 970707-11.No Violations Noted. Major Areas Inspected:Plant Support ML20149G7411997-07-11011 July 1997 Insp Rept 50-395/97-05 on 970504-0614.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970061997-06-27027 June 1997 Insp Rept 50-395/97-06 on 970527-30.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20140D4521997-06-0202 June 1997 Insp Rept 50-395/97-03 on 970323-0503.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970011997-04-17017 April 1997 Insp Rept 50-395/97-01 on 970209-0322.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19960151997-03-10010 March 1997 Insp Rept 50-395/96-15 on 961229-970208.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20134G6181997-01-27027 January 1997 Insp Rept 50-395/96-14 on 961201-28.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19960131996-12-30030 December 1996 Insp Rept 50-395/96-13 on 961027-1130.Noncited Violations Identified.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000395/19960111996-11-25025 November 1996 Insp Rept 50-395/96-11 on 960908-1026.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19960121996-10-11011 October 1996 Insp Rept 50-395/96-12 on 960916-19.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20128K0101996-10-0404 October 1996 Insp Rept 50-395/96-09 on 960721-0907.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering,Plant Support IR 05000395/19960101996-09-20020 September 1996 Insp Rept 50-395/96-10 on 960819-23.No Violations Noted. Major Areas Inspected:Protected Area Detection Equipment, Alarm Stations & Communications,Testing,Maint,Compensatory Measures,Security Training & Qualifications & Followup Insp IR 05000395/19930281994-01-11011 January 1994 Insp Rept 50-395/93-28 on 931213-17.No Violations Noted. Major Areas Inspected:Organization & Staffing,Audits & Appraisals,Training & Qualifications & External & Internal Exposure Controls IR 05000395/19930251993-12-0202 December 1993 Insp Rept 50-395/93-25 on 931014-1120.No Violations Noted. Major Areas Inspected:Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Review of Licensee self-assessment Capability IR 05000395/19930241993-10-27027 October 1993 Insp Rept 50-395/93-24 on 930904-1013.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification & Installation & Testing of Mods IR 05000395/19930231993-09-28028 September 1993 Insp Rept 50-395/93-23 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection & Assessment Aids & Vital Area Access.Partially Withheld IR 05000395/19930221993-09-21021 September 1993 Insp Rept 50-395/93-22 on 930801-0903.Violations Noted But Not Cited.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification,Esfs Sys Walkdown & Fire Protection IR 05000395/19930211993-08-12012 August 1993 Insp Rept 50-395/93-21 on 930719-23.No Violations Noted. Major Areas Inspected:Audits Performed by Licensee,Ts Chemistry Parameters,Dose Calculations,Semiannual Radioactive Effluents Rept & Organizational Changes ML20056E9721993-08-11011 August 1993 Insp Rept 50-395/93-20 on 930712-16.Weaknesses Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise ML20056F6031993-08-10010 August 1993 Insp Rept 50-395/93-19 on 930716-31.Violations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification & Review of Licensee self-assessment Capabilities IR 05000395/19930171993-07-0202 July 1993 Insp Rept 50-395/93-17 on 930511-0615.Violations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification,Review of Noncomformance Conditions & Info Meetings W/Local Officials IR 05000395/19930021993-02-0505 February 1993 Insp Rept 50-395/93-02 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness IR 05000395/19920231993-01-21021 January 1993 Insp Rept 50-395/92-23 on 921201-930108.No Violations or Deviations Noted.Concern Noted.Major Areas Inspected: Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Installation & Testing Mods IR 05000395/19920221992-12-30030 December 1992 Insp Rept 50-395/92-22 on 921130-1204.Violation Noted,But Not Cited.Major Areas Inspected:Occupational Radiation Safety,Including Exam of Organization & Staffing,Audits, Appraisals & Training & Qualifications IR 05000395/19920211992-12-11011 December 1992 Insp Rept 50-395/92-21 on 921101-30.Violation Noted But Not Cited.Major Areas Inspected:Monthly Maint/Surveillance Observations,Operational Safety Verification,Cold Weather Preparations & Installation & Testing of Mods 1999-08-30 Category:NRC-GENERATED MONTHYEARIR 05000395/19990061999-10-0808 October 1999
[Table view]Insp Rept 50-395/99-06 on 990801-0911.One Violation Identified & Being Treated as Ncv.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000395/19990051999-08-30030 August 1999 Insp Rept 50-395/99-05 on 990620-0731.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990041999-07-16016 July 1999 Insp Rept 50-395/99-04 on 990509-0619.Noncited Violation Identified.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering & Plant Support ML20207H5331999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990031999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990021999-04-26026 April 1999 Insp Rept 50-395/99-02 on 990214-0327.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990011999-03-15015 March 1999 Insp Rept 50-395/99-01 on 990103-0213.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980101999-02-0101 February 1999 Insp Rept 50-395/98-10 on 981122-990122.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980091998-12-21021 December 1998 Insp Rept 50-395/98-09 on 981011-1121.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980081998-11-0909 November 1998 Insp Rept 50-395/98-08 on 980906-1010.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980071998-10-0505 October 1998 Insp Rept 50-395/98-07 on 980726-0905.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980061998-09-24024 September 1998 Insp Rept 50-395/98-06 on 980628-0725.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980051998-07-27027 July 1998 Insp Rept 50-395/98-05 on 980517-0627.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980041998-06-15015 June 1998 Insp Rept 50-395/98-04 on 980405-0516.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980031998-05-29029 May 1998 Insp Rept 50-395/98-03 on 980330-0417.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C6681998-05-0404 May 1998 Insp Rept 50-395/98-02 on 980222-0404.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217G4651998-03-20020 March 1998 Insp Rept 50-395/98-01 on 980111-0221.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203J7531998-02-0909 February 1998 Insp Rept 50-395/97-14 on 971130-980110.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19970131997-12-23023 December 1997 Insp Rept 50-395/97-13 on 971019-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970121997-11-17017 November 1997 Insp Rept 50-395/97-12 on 970907-1018.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970111997-10-0202 October 1997 Insp Rept 50-395/97-11 on 970727-0906.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support ML20203L2831997-09-24024 September 1997 Insp Rept for VC Summer Nuclear Station on 970227.No Conditions Observed at Time of Insp That Could Be Considered Immediate Threat to Safety of Dams or Nuclear Facility.Major Areas Inspected:Service Water Pond Dams IR 05000395/19970101997-08-22022 August 1997 Insp Rept 50-395/97-10 on 970714-18.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise ML20210N9401997-08-21021 August 1997 Insp Rept 50-395/97-07 on 970615-0726.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970091997-08-11011 August 1997 Insp Rept 50-395/97-09 on 970707-11.No Violations Noted. Major Areas Inspected:Area of Plant Support by Two Regional Safeguards Inspectors IR 05000395/19970081997-08-0808 August 1997 Insp Rept 50-395/97-08 on 970707-11.No Violations Noted. Major Areas Inspected:Plant Support ML20149G7411997-07-11011 July 1997 Insp Rept 50-395/97-05 on 970504-0614.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970061997-06-27027 June 1997 Insp Rept 50-395/97-06 on 970527-30.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20140D4521997-06-0202 June 1997 Insp Rept 50-395/97-03 on 970323-0503.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970011997-04-17017 April 1997 Insp Rept 50-395/97-01 on 970209-0322.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19960151997-03-10010 March 1997 Insp Rept 50-395/96-15 on 961229-970208.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20134G6181997-01-27027 January 1997 Insp Rept 50-395/96-14 on 961201-28.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19960131996-12-30030 December 1996 Insp Rept 50-395/96-13 on 961027-1130.Noncited Violations Identified.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000395/19960111996-11-25025 November 1996 Insp Rept 50-395/96-11 on 960908-1026.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19960121996-10-11011 October 1996 Insp Rept 50-395/96-12 on 960916-19.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20128K0101996-10-0404 October 1996 Insp Rept 50-395/96-09 on 960721-0907.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering,Plant Support IR 05000395/19960101996-09-20020 September 1996 Insp Rept 50-395/96-10 on 960819-23.No Violations Noted. Major Areas Inspected:Protected Area Detection Equipment, Alarm Stations & Communications,Testing,Maint,Compensatory Measures,Security Training & Qualifications & Followup Insp IR 05000395/19930281994-01-11011 January 1994 Insp Rept 50-395/93-28 on 931213-17.No Violations Noted. Major Areas Inspected:Organization & Staffing,Audits & Appraisals,Training & Qualifications & External & Internal Exposure Controls IR 05000395/19930251993-12-0202 December 1993 Insp Rept 50-395/93-25 on 931014-1120.No Violations Noted. Major Areas Inspected:Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Review of Licensee self-assessment Capability IR 05000395/19930241993-10-27027 October 1993 Insp Rept 50-395/93-24 on 930904-1013.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification & Installation & Testing of Mods IR 05000395/19930231993-09-28028 September 1993 Insp Rept 50-395/93-23 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection & Assessment Aids & Vital Area Access.Partially Withheld IR 05000395/19930221993-09-21021 September 1993 Insp Rept 50-395/93-22 on 930801-0903.Violations Noted But Not Cited.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification,Esfs Sys Walkdown & Fire Protection IR 05000395/19930211993-08-12012 August 1993 Insp Rept 50-395/93-21 on 930719-23.No Violations Noted. Major Areas Inspected:Audits Performed by Licensee,Ts Chemistry Parameters,Dose Calculations,Semiannual Radioactive Effluents Rept & Organizational Changes ML20056E9721993-08-11011 August 1993 Insp Rept 50-395/93-20 on 930712-16.Weaknesses Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise ML20056F6031993-08-10010 August 1993 Insp Rept 50-395/93-19 on 930716-31.Violations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification & Review of Licensee self-assessment Capabilities IR 05000395/19930171993-07-0202 July 1993 Insp Rept 50-395/93-17 on 930511-0615.Violations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification,Review of Noncomformance Conditions & Info Meetings W/Local Officials IR 05000395/19930021993-02-0505 February 1993 Insp Rept 50-395/93-02 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness IR 05000395/19920231993-01-21021 January 1993 Insp Rept 50-395/92-23 on 921201-930108.No Violations or Deviations Noted.Concern Noted.Major Areas Inspected: Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Installation & Testing Mods IR 05000395/19920221992-12-30030 December 1992 Insp Rept 50-395/92-22 on 921130-1204.Violation Noted,But Not Cited.Major Areas Inspected:Occupational Radiation Safety,Including Exam of Organization & Staffing,Audits, Appraisals & Training & Qualifications IR 05000395/19920211992-12-11011 December 1992 Insp Rept 50-395/92-21 on 921101-30.Violation Noted But Not Cited.Major Areas Inspected:Monthly Maint/Surveillance Observations,Operational Safety Verification,Cold Weather Preparations & Installation & Testing of Mods 1999-08-30 Category:INSPECTION REPORT MONTHYEARIR 05000395/19990061999-10-0808 October 1999
[Table view]Insp Rept 50-395/99-06 on 990801-0911.One Violation Identified & Being Treated as Ncv.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000395/19990051999-08-30030 August 1999 Insp Rept 50-395/99-05 on 990620-0731.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990041999-07-16016 July 1999 Insp Rept 50-395/99-04 on 990509-0619.Noncited Violation Identified.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering & Plant Support ML20207H5331999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990031999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990021999-04-26026 April 1999 Insp Rept 50-395/99-02 on 990214-0327.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990011999-03-15015 March 1999 Insp Rept 50-395/99-01 on 990103-0213.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980101999-02-0101 February 1999 Insp Rept 50-395/98-10 on 981122-990122.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980091998-12-21021 December 1998 Insp Rept 50-395/98-09 on 981011-1121.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980081998-11-0909 November 1998 Insp Rept 50-395/98-08 on 980906-1010.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980071998-10-0505 October 1998 Insp Rept 50-395/98-07 on 980726-0905.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980061998-09-24024 September 1998 Insp Rept 50-395/98-06 on 980628-0725.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980051998-07-27027 July 1998 Insp Rept 50-395/98-05 on 980517-0627.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980041998-06-15015 June 1998 Insp Rept 50-395/98-04 on 980405-0516.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980031998-05-29029 May 1998 Insp Rept 50-395/98-03 on 980330-0417.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C6681998-05-0404 May 1998 Insp Rept 50-395/98-02 on 980222-0404.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217G4651998-03-20020 March 1998 Insp Rept 50-395/98-01 on 980111-0221.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203J7531998-02-0909 February 1998 Insp Rept 50-395/97-14 on 971130-980110.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19970131997-12-23023 December 1997 Insp Rept 50-395/97-13 on 971019-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970121997-11-17017 November 1997 Insp Rept 50-395/97-12 on 970907-1018.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970111997-10-0202 October 1997 Insp Rept 50-395/97-11 on 970727-0906.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support ML20203L2831997-09-24024 September 1997 Insp Rept for VC Summer Nuclear Station on 970227.No Conditions Observed at Time of Insp That Could Be Considered Immediate Threat to Safety of Dams or Nuclear Facility.Major Areas Inspected:Service Water Pond Dams IR 05000395/19970101997-08-22022 August 1997 Insp Rept 50-395/97-10 on 970714-18.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise ML20210N9401997-08-21021 August 1997 Insp Rept 50-395/97-07 on 970615-0726.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970091997-08-11011 August 1997 Insp Rept 50-395/97-09 on 970707-11.No Violations Noted. Major Areas Inspected:Area of Plant Support by Two Regional Safeguards Inspectors IR 05000395/19970081997-08-0808 August 1997 Insp Rept 50-395/97-08 on 970707-11.No Violations Noted. Major Areas Inspected:Plant Support ML20149G7411997-07-11011 July 1997 Insp Rept 50-395/97-05 on 970504-0614.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970061997-06-27027 June 1997 Insp Rept 50-395/97-06 on 970527-30.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20140D4521997-06-0202 June 1997 Insp Rept 50-395/97-03 on 970323-0503.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970011997-04-17017 April 1997 Insp Rept 50-395/97-01 on 970209-0322.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19960151997-03-10010 March 1997 Insp Rept 50-395/96-15 on 961229-970208.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20134G6181997-01-27027 January 1997 Insp Rept 50-395/96-14 on 961201-28.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19960131996-12-30030 December 1996 Insp Rept 50-395/96-13 on 961027-1130.Noncited Violations Identified.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000395/19960111996-11-25025 November 1996 Insp Rept 50-395/96-11 on 960908-1026.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19960121996-10-11011 October 1996 Insp Rept 50-395/96-12 on 960916-19.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20128K0101996-10-0404 October 1996 Insp Rept 50-395/96-09 on 960721-0907.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering,Plant Support IR 05000395/19960101996-09-20020 September 1996 Insp Rept 50-395/96-10 on 960819-23.No Violations Noted. Major Areas Inspected:Protected Area Detection Equipment, Alarm Stations & Communications,Testing,Maint,Compensatory Measures,Security Training & Qualifications & Followup Insp IR 05000395/19930281994-01-11011 January 1994 Insp Rept 50-395/93-28 on 931213-17.No Violations Noted. Major Areas Inspected:Organization & Staffing,Audits & Appraisals,Training & Qualifications & External & Internal Exposure Controls IR 05000395/19930251993-12-0202 December 1993 Insp Rept 50-395/93-25 on 931014-1120.No Violations Noted. Major Areas Inspected:Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Review of Licensee self-assessment Capability IR 05000395/19930241993-10-27027 October 1993 Insp Rept 50-395/93-24 on 930904-1013.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification & Installation & Testing of Mods IR 05000395/19930231993-09-28028 September 1993 Insp Rept 50-395/93-23 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection & Assessment Aids & Vital Area Access.Partially Withheld IR 05000395/19930221993-09-21021 September 1993 Insp Rept 50-395/93-22 on 930801-0903.Violations Noted But Not Cited.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification,Esfs Sys Walkdown & Fire Protection IR 05000395/19930211993-08-12012 August 1993 Insp Rept 50-395/93-21 on 930719-23.No Violations Noted. Major Areas Inspected:Audits Performed by Licensee,Ts Chemistry Parameters,Dose Calculations,Semiannual Radioactive Effluents Rept & Organizational Changes ML20056E9721993-08-11011 August 1993 Insp Rept 50-395/93-20 on 930712-16.Weaknesses Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise ML20056F6031993-08-10010 August 1993 Insp Rept 50-395/93-19 on 930716-31.Violations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification & Review of Licensee self-assessment Capabilities IR 05000395/19930171993-07-0202 July 1993 Insp Rept 50-395/93-17 on 930511-0615.Violations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observations,Operational Safety Verification,Review of Noncomformance Conditions & Info Meetings W/Local Officials IR 05000395/19930021993-02-0505 February 1993 Insp Rept 50-395/93-02 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness IR 05000395/19920231993-01-21021 January 1993 Insp Rept 50-395/92-23 on 921201-930108.No Violations or Deviations Noted.Concern Noted.Major Areas Inspected: Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Installation & Testing Mods IR 05000395/19920221992-12-30030 December 1992 Insp Rept 50-395/92-22 on 921130-1204.Violation Noted,But Not Cited.Major Areas Inspected:Occupational Radiation Safety,Including Exam of Organization & Staffing,Audits, Appraisals & Training & Qualifications IR 05000395/19920211992-12-11011 December 1992 Insp Rept 50-395/92-21 on 921101-30.Violation Noted But Not Cited.Major Areas Inspected:Monthly Maint/Surveillance Observations,Operational Safety Verification,Cold Weather Preparations & Installation & Testing of Mods 1999-08-30 Category:UTILITY MONTHYEARIR 05000395/19900271990-11-16016 November 1990
[Table view]Insp Rept 50-395/90-27 on 901001-31.No Violations Noted. Major Areas Inspected:Surveillance Observations,Monthly Maintenance Observation,Operational Safety verification,on- Site follow-up of Written Repts of Nonroutine Events ML20058A6011990-10-19019 October 1990 Partially Withheld Insp Rept 50-395/90-26 on 900918-19 (Ref 10CFR73.21).Violations Noted But Not Cited.Major Areas Inspected:Access Control Packages,In Response to Reported Introduction of Firearm in Protected Area on 900813 IR 05000395/19900241990-10-12012 October 1990 Insp Rept 50-395/90-24 on 900901-30.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance & Maint Observations,Operational Safety Verification,Onsite Followup of Written Repts & Followup of Events IR 05000395/19900211990-08-0909 August 1990 Insp Rept 50-395/90-21 on 900701-31.Violation Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification & Onsite Followup Written Repts of Nonroutine Events at Facilities IR 05000395/19900181990-07-12012 July 1990 Insp Rept 50-395/90-18 on 900601-30.Violation Noted.Major Areas Inspected:Monthly Surveillance & Maint Observations, Operational Safety Verification,Onsite Followup of Written Repts of Nonroutine Events at Power Reactor Facilities IR 05000395/19900191990-07-0303 July 1990 Insp Rept 50-395/90-19 on 900611-15.Noncited Violation Noted.Major Areas Inspected:Emergency Preparedness to Determine If Licensee Program Being Maintained in State of Operational Readiness for Responding to Emergencies IR 05000395/19890171989-09-12012 September 1989 Insp Rept 50-395/89-17 on 890801-31.Violations Noted.Major Areas Inspected:Monthly Surveillance Operations,Monthly Maint Operation,Operational Safety Verification,Esf Sys Walkdown & Onsite Followup of Events & Written Repts IR 05000395/19890151989-08-16016 August 1989 Insp Rept 50-395/89-15 on 890724-28.Violations Noted.Major Areas Inspected:Inservice Testing & Followup on Previous Insp Findings IR 05000395/19890161989-08-0404 August 1989 Partially Withheld Insp Rept 50-395/89-16 on 890710-14 (Ref 10CFR2.790).No Violations or Deviations Noted.Major Areas Inspected:Security Plan & Implementing Procedures,Mgt Effectiveness & Security Program & Organization ML20246A5341989-08-0404 August 1989 Insp Rept 50-395/89-13 on 890701-31.Violation Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification,Action on Previous Insp Findings & Other Areas IR 05000395/19890121989-07-28028 July 1989 Insp Rept 50-395/89-12 on 890626-30.No Violations or Deviations Noted.Major Areas Inspected:Followup of Osti Insp Completed in Dec 1988 IR 05000395/19890111989-07-12012 July 1989 Insp Rept 50-395/89-11 on 890601-30.No Violations Noted. Major Areas Inspected:Monthly Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Onsite Followup of Events IR 05000395/19890101989-07-0707 July 1989 Insp Rept 50-395/89-10 on 890605-08.No Violations or Deviations Noted.Major Areas Inspected:Observation & Evaluation of Annual Radiological Emergency Response Exercise IR 05000395/19890091989-06-0909 June 1989 Insp Rept 50-395/89-09 on 890501-31.No Violations Noted. Major Areas Inspected:Monthly Surveillance,Maint & Surveillance Observations,Operational Safety Verification, ESF Sys Walkdown,Onsite Followup of Events & Written Repts IR 05000395/19890081989-05-11011 May 1989 Partially Withheld Insp Rept 50-395/89-08 on 890417-21 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Vital & Protected Area Barriers, Detection & Assessment Aids & Access Control of Personnel IR 05000395/19890051989-04-18018 April 1989 Insp Rept 50-395/89-05 on 890227-0303.No Violations Noted. Major Areas Inspected:Licensee Program to Maintain Occupational Radiation Exposures ALARA IR 05000395/19890061989-04-12012 April 1989 Insp Rept 50-395/89-06 on 890301-31.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification & ESF Sys Walkdown IR 05000395/19890041989-03-15015 March 1989 Insp Rept 50-395/89-04 on 890213-17.One licensee-identified Violation Noted.Major Areas Inspected:Design Control,Changes & Mods IR 05000395/19880031989-03-0909 March 1989 Insp Rept 50-395/88-03 on 890206-28.Violation Noted.Major Areas Inspected:Monthly Surveillance & Maint Observations, Operational Safety Verification,Esf Sys Walkdown & Action on Previous Insp Findings ML20246L2641989-02-23023 February 1989 Insp Rept 50-395/89-02 on 890123-27.Violations Noted.Major Areas Inspected:Review of Training,Changes to Emergency Organization,Distribution of Changes to Emergency Plan & Emergency Plan Procedures & Audits Repts ML20235Y5671989-02-17017 February 1989 Insp Rept 50-395/88-26 on 881114-18,1205-09 & 20-23. Violations Noted.Major Areas Inspected:Current Level of Performance in Area of Plant Operations W/Evaluation of Effectiveness of Various Plant Groups,Including Operations IR 05000395/19890011989-02-0909 February 1989 Insp Rept 50-395/89-01 on 890101-0205.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance & Maint Observations,Operational Safety Verification & ESF Sys Walkdown IR 05000395/19880231988-12-0101 December 1988 Insp Rept 50-395/88-23 on 881017-21.Violation Noted.Major Areas Inspected:Environ Qualification of Electrical Equipment,Including Review of Util Implementation of Program to Meet 10CFR50.49 Requirements & Followup on Previous Insp IR 05000395/19880251988-11-22022 November 1988 Insp Rept 50-395/88-25 on 881001-31.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification & Onsite Followup of Events IR 05000395/19880271988-11-18018 November 1988 Insp Rept 50-395/88-27 on 881031-1104.No Violations or Deviations Noted.Major Areas Inspected:Refueling Activities, Routine Surveillance of Core Power Distribution Limits & Shutdown Margin & Reactivity Anomaly IR 05000395/19880221988-10-25025 October 1988 Insp Rept 50-395/88-22 on 880926-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp,Review of Program,Review of Procedure & Observation of Work & Work Activities & NRC Bulletin 87-001 IR 05000395/19880241988-10-24024 October 1988 Insp Rept 50-395/88-24 on 880926-30.No Violations or Deviations Noted.Major Areas Inspected:Witnessing Primary Containment Integrated Leak Rate Test & Review of Containment Integrated Leak Rate Test Procedure IR 05000395/19880201988-10-24024 October 1988 Insp Rept 50-395/88-20 on 880912-17.No Violations or Deviations Noted.Major Areas Inspected:Complex Surveillance Testing,Ie Bulletin & IE Notice Followup IR 05000395/19880211988-10-24024 October 1988 Insp Rept 50-395/88-21 on 880919-22.No Violations or Deviations Noted.Major Areas Inspected:Licensee Conformance to Reg Guide 1.97, Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant & Environs.. IR 05000395/19880191988-10-11011 October 1988 Insp Rept 50-395/88-19 on 880901-30.Violation Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification, ESF Sys Walkdown & Other Areas IR 05000395/19880181988-09-23023 September 1988 Insp Rept 50-395/88-18 on 880829-0902.No Violations or Deviations Noted.Major Areas Inspected:Nrc Bulletins & Matl Identification.Investment in Mobile Spectographic Equipment Is Positive Example of Mgt Involvement in QA ML20155A8751988-09-15015 September 1988 Insp Rept 50-395/88-17 on 880801-31.Violations Noted.Major Areas Inspected:Unresolved Items,Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Onsite Followup of Events IR 05000395/19880141988-08-0808 August 1988 Insp Rept 50-395/88-14 on 880601-0731.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance & Maint Observations,Operational Safety Verification,Esf Sys Walkdown & Generic Ltr 83-28 Followup ML20151R9961988-07-26026 July 1988 Insp Rept 50-395/88-15 on 880613-17.Violations & Deviations Noted.Major Areas Inspected:Review of Current Svc Water Sys & Design Bases & Plant Actions Taken to Respond to Current NRC Svc Water Concerns ML20195K2551988-06-14014 June 1988 Insp Rept 50-395/88-13 on 880501-31.Violation Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification,Esf Walkdown,Design & Design Changes & Mod IR 05000395/19880121988-05-19019 May 1988 Insp Rept 50-395/88-12 on 880502-05.No Violations Noted. Major Areas Inspected:Reportability Determination,Qa Reviews & Security IR 05000395/19880101988-05-13013 May 1988 Insp Rept 50-395/88-10 in Apr 1988.No Violations Noted. Major Areas Inspected:Previous Insp Findings,Monthly Surveillance Observations,Monthly Maint Observations & Operational Safety Verification IR 05000395/19880061988-05-0303 May 1988 Insp Rept 50-395/88-06 on 880315-18.No Violations or Deviations Noted.Major Areas Inspected:Selected Procedures & Representative Records,Emergency Response Facilities & Related Equipment & Interviews W/Licensee Personnel ML20153E7631988-04-22022 April 1988 Insp Rept 50-395/88-01 on 880111-15.Violations Noted.Major Areas Inspected:Environ Qualification of Electrical Equipment IR 05000395/19880091988-04-13013 April 1988 Partially Withheld Physical Security Insp Rept 50-395/88-09 on 880314-18 (Ref 10CFR2.790(d) & 73.21).No Violations Noted.Major Areas Inspected:Security Program Audit,Records & Repts,Testing & Maint & Security Sys Power Supply IR 05000395/19880081988-04-0606 April 1988 Insp Rept 50-395/88-08 on 880301-31.No Violations or Deviations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Monthly Surveillance Observations, Radiological Protection,Physcial Security & Written Repts ML20148K8391988-03-21021 March 1988 Insp Rept 50-395/88-07 on 880229-0304.Violations Noted.Major Areas inspected:post-refueling Startup Tests & Local Leak Rate Testing IR 05000395/19880051988-03-14014 March 1988 Insp Rept 50-395/88-05 on 880201-29.No Violations or Deviations Noted.Major Areas Inspected:Monthly Surveillance Observations,Monthly Maint Observation,Operational Safety Verification,Esf Sys Walkdown & Physical Security IR 05000395/19880041988-02-29029 February 1988 Insp Rept 50-395/88-04 on 880201-05.No Violations Noted. Major Areas Inspected:Seismic Monitoring Program & Fire Protection/Prevention Program IR 05000395/19870361988-01-20020 January 1988 Insp Rept 50-395/87-36 on 871201-880104.No Violations or Deviations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Monthly Surveillance Observation, Operational Safety Verification & IE Bulletin Followup IR 05000395/19870351988-01-0606 January 1988 Insp Rept 50-395/87-35 on 871207-11.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Effluents & Gathering of Data on Collocated Licensee & NRC Environ TLDs IR 05000395/19870321987-12-31031 December 1987 Insp Rept 50-395/87-32 on 871116-20.No Violations or Deviations Noted.Major Areas Inspected:Licensed & Nonlicensed Staff Training IR 05000395/19870331987-12-0808 December 1987 Insp Rept 50-395/87-33 on 871101-30.No Violations or Deviations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Onsite Followup of Events,Subsequent Written Rept & ESF Sys Walkdown IR 05000395/19870311987-11-27027 November 1987 Partially Withheld Insp Rept 50-395/87-31 on 871102-06. Violation Noted.Major Areas Inspected:Physical Security Plan & Implementing Procedures,Mgt Effectiveness - Security Program,Security Organization,Locks Keys & Combinations IR 05000395/19870301987-11-12012 November 1987 Insp Rept 50-395/87-30 on 871020-30.Violations Noted.Major Areas Inspected:Followup on Environ Qualification Deficiencies Involving V-stub Taped Splices Used for Various Components 1990-08-09 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000395/19990061999-10-0808 October 1999
[Table view]Insp Rept 50-395/99-06 on 990801-0911.One Violation Identified & Being Treated as Ncv.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000395/19990051999-08-30030 August 1999 Insp Rept 50-395/99-05 on 990620-0731.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990041999-07-16016 July 1999 Insp Rept 50-395/99-04 on 990509-0619.Noncited Violation Identified.Major Areas Inspected:Aspects of Licensee Operation,Maint,Engineering & Plant Support ML20207H5331999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990031999-06-0707 June 1999 Insp Rept 50-395/99-03 on 990328-0508.Six Violations of NRC Requirements Occurred & Being Treated as non-cited Violations.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19990021999-04-26026 April 1999 Insp Rept 50-395/99-02 on 990214-0327.Non-cited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000395/19990011999-03-15015 March 1999 Insp Rept 50-395/99-01 on 990103-0213.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980101999-02-0101 February 1999 Insp Rept 50-395/98-10 on 981122-990122.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980091998-12-21021 December 1998 Insp Rept 50-395/98-09 on 981011-1121.Violation Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198N8491998-12-21021 December 1998 Notice of Violation from Insp on 981011-1121.Violation Noted:On 980715,operations Personnel Authorized Maint Activities on ECCS Accumulators a & C Outlet Isolation Valve Breakers Without Recognizing Sys Would Become Inoperable IR 05000395/19980081998-11-0909 November 1998 Insp Rept 50-395/98-08 on 980906-1010.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980071998-10-0505 October 1998 Insp Rept 50-395/98-07 on 980726-0905.No Violations Noted. Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19980061998-09-24024 September 1998 Insp Rept 50-395/98-06 on 980628-0725.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19980991998-08-26026 August 1998 SALP Rept 50-395/98-99 for Period of 961027-980725 IR 05000395/19980051998-07-27027 July 1998 Insp Rept 50-395/98-05 on 980517-0627.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19980041998-06-15015 June 1998 Insp Rept 50-395/98-04 on 980405-0516.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236H0021998-06-15015 June 1998 Notice of Violation from Insp on 980405-0516.Violation Noted:On 980123 Condition Adverse to Quality Was Not Promptly Identified & Corrected IR 05000395/19980031998-05-29029 May 1998 Insp Rept 50-395/98-03 on 980330-0417.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20248J3281998-05-29029 May 1998 Notice of Violation from Insp on 980330-0417.Violation Noted:Instructions or Procedures Not Followed for Performance of Listed Activities ML20216C6681998-05-0404 May 1998 Insp Rept 50-395/98-02 on 980222-0404.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C6581998-05-0404 May 1998 Notice of Violation from Insp on 980222-0404.Violation Noted:On 980319,security Officer Failed to Ensure That Neither Operator Nor Accompanying Personnel Were Provided Access to Any Portion of Vehicle Until Search Completed ML20217G4431998-03-20020 March 1998 Notice of Violation from Insp on 980111-0221.Violation Noted:Licensee Failed to Establish Adequate Requirements to Insure That Temporary Shielding Properly Controlled ML20217G4651998-03-20020 March 1998 Insp Rept 50-395/98-01 on 980111-0221.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203J7471998-02-0909 February 1998 Notice of Violation from Insp on 971130-980110.Violation Noted:On 971209,licensee Failed to Sign Off Applicable Steps to Mechanical Maintenance Procedure 300.033,rev 2,at Completion of Each Step ML20203J7531998-02-0909 February 1998 Insp Rept 50-395/97-14 on 971130-980110.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000395/19973001998-01-14014 January 1998 NRC Operator Licensing Exam Rept 50-395/97-300 (Including Completed & Graded Tests) for Tests Administered on 971201- 05 & 1212 IR 05000395/19970131997-12-23023 December 1997 Insp Rept 50-395/97-13 on 971019-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198N6871997-12-23023 December 1997 Notice of Violation from Insp on 971019-1129.Violation Noted:On 971019,licensee Employee Failed to Adhere to Posted HP Instructions in That Individual Observed Using Chewing Tobacco Product in B Chiller Unit Room IR 05000395/19970121997-11-17017 November 1997 Insp Rept 50-395/97-12 on 970907-1018.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970111997-10-0202 October 1997 Insp Rept 50-395/97-11 on 970727-0906.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support ML20211K5271997-10-0202 October 1997 Notice of Violation from Insp on 970727-0906.Violation Noted:On 970817,licensee Identified That Procedures STP-345.001,STP-345.002 & STP-345.003 Had Not Been Maintained to Ensure Correct Setting of OT Delta T ML20203L2831997-09-24024 September 1997 Insp Rept for VC Summer Nuclear Station on 970227.No Conditions Observed at Time of Insp That Could Be Considered Immediate Threat to Safety of Dams or Nuclear Facility.Major Areas Inspected:Service Water Pond Dams IR 05000395/19970101997-08-22022 August 1997 Insp Rept 50-395/97-10 on 970714-18.No Violations Noted. Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise ML20210N9401997-08-21021 August 1997 Insp Rept 50-395/97-07 on 970615-0726.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support ML20210N9331997-08-21021 August 1997 Notice of Violation from Insp on 970615-0726.Violation Noted:Train a Hydrogen Monitor Containment Isolation Valves, SVX-6051A,SVX-6052A & SVX-6053A,were Open on an Intermittent Basis to Perform Hydrogen Monitor Calibration IR 05000395/19970091997-08-11011 August 1997 Insp Rept 50-395/97-09 on 970707-11.No Violations Noted. Major Areas Inspected:Area of Plant Support by Two Regional Safeguards Inspectors IR 05000395/19970081997-08-0808 August 1997 Insp Rept 50-395/97-08 on 970707-11.No Violations Noted. Major Areas Inspected:Plant Support ML20149G7371997-07-11011 July 1997 Notice of Violation from Insp on 970504-0614.Violation Noted:Licensee Did Not Preclude Repetition of Failure to Implement Storage Requirements ML20149G7411997-07-11011 July 1997 Insp Rept 50-395/97-05 on 970504-0614.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant Support IR 05000395/19970061997-06-27027 June 1997 Insp Rept 50-395/97-06 on 970527-30.No Violations Noted. Major Areas Inspected:Physical Security Program for Power Reactors ML20140D4351997-06-0202 June 1997 Notice of Violation from Insp on 970323-0503.Violation Noted:On 970413,SOP-114 Not Implemented to Increase RB Pressure ML20140D4521997-06-0202 June 1997 Insp Rept 50-395/97-03 on 970323-0503.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000395/19970011997-04-17017 April 1997 Insp Rept 50-395/97-01 on 970209-0322.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20147G2981997-03-10010 March 1997 Notice of Violation from Insp on 961229-970208.Violation Noted:Between 940628-961202,EFW Pump Quarterly SG low-low Actuation Slave Relay Test Was Not Performed within Required Frequency Specified in TS Surveillance Requirement 4.3.2.1 IR 05000395/19960151997-03-10010 March 1997 Insp Rept 50-395/96-15 on 961229-970208.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20134G6181997-01-27027 January 1997 Insp Rept 50-395/96-14 on 961201-28.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20134G6061997-01-27027 January 1997 Notice of Violation from Insp on 961201-28.Violation Noted: SAP-142 Was Not Implemented & Provisions of Designated Storage Area Change Request 129 Were Not Complied with IR 05000395/19960131996-12-30030 December 1996 Insp Rept 50-395/96-13 on 961027-1130.Noncited Violations Identified.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20149M5921996-12-0606 December 1996 SALP Rept 50-395/96-99 for Period of 950129 Through 961026 IR 05000395/19960111996-11-25025 November 1996 Insp Rept 50-395/96-11 on 960908-1026.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-08-30 |
Inspection Report - Summer - 1987013 | |
---|---|
Text
r- -
,
.
km R8 ?o UNITED STATES ,
[ q'o NUCLEAR REGULATORY COMMISSION
[
g
- #
j REGloN la 101 MARIETTA STREET, * * ATLANTA, GEORGI A 30323 ,
%,
f- \
..... MAY 2 g 1997 Report No.: 50-395/87-13 Licensee: South Carolina Electric and Gas Company Columbia, SC 29218 Docket No.: 50-395 License No.: NpF-12 Facility Name: . Summer Inspection Conduc e : April 27-28, 1987 Inspector: [/ ---- / - , Md S O fodd,(Safegar @ itor / Date Sigtfed~
Approved by: CD'
E. J. McArpine, Chief,haterial Control and
_
5/2.1/97 Date Signed Accountability Section, Nuclear Materials Safety and Safeguards Branch, Division of Radiation Safety and Safeguards SUMMARY Scope: This routine, unannounced inspection entailed the review of procedures and operations for the use, control, and accountability of special nuclear materia Results: No violations or deviations were identifie .
8706030342 870522 PDR ADOCK 05000395 0 PDR l
c
.
.
p REPORT DETAILS
' Report No. 50-395/87-13 Persons Contacted Licensee Employees
- 0 S. Bradham, Director, Nuclear Plant Operations
- A. R. Koon, Jr. , Manager, Technical Support
- N. Brown, Group Manager, Technical and Support Services
- R. Higgins, Associate Manager, Regulatory Compliance
- G. A. Loignon, Jr., Associate Manager, Performance and Results
- A. M. Monroe, Regulatory Compliance Engineer NRC Resident Inspector
- P. C. Hopkins, NRC Resident Inspector The inspector also interviewed several other licensee employee * Denotes those present at the exit intervie . Exit Interview The inspection scope and findings were summarized on April 28, 1987, with those persons indicated in paragraph 1 above. The licensee acknowledged the inspection scope and findings and took no exception . Material Control and Accounting - Power Reactors (85102)
The inspection was conducted to determine the adequacy of South Carolina Electric and Gas Company's program to account for and control the special nuclear material (SNM) in it's possession and to limit the use of possessed SNM to the locations and purposes authorized by license at the V. C. Summer Power Statio ~The licensee's material controls were examined by review of procedures, audit of records, review of the conduct of physical inventory and interviews with appropriate licensee personne The licensee's procedures for nuclear material control and accountability are structured according to organizational responsibilities and authorities for the formulation, implementation, maintenance and periodic assessment, and evaluation of the accountability progra The inspector reviewed the procedures and documents listed below:
- Special Nuclear Material Inventory and Control, Revision 2, dated May 29, 198 I
<
.
,
,
I -
Material Transfer Form l II -
Core Shuffle Material Transfer Form N I' III - SNM Card File
-
IV -
Reactor Core Inventcry V -
Spent Fuel Pool Inventory Va -
Spent Fuel Pool Indexing Scheme VI -
SNM Inventory Documentation Control Log VIII - Assembly Discharge Burnup, Mwd /kgU IX -
SNM Audit Log X -
Spent Fuel Pool Use Prerequisite Checklist The referenced procedures and documents delineated organizational assignments and specified sufficient separation of functions to provide the necessary checks and balances for the control of SNM. The procedures provide detailed reference material, definitions of terms and operational guidance sufficient to properly receive, handle, store, inventory, calculate burnup-related measurements and report an accurate material balance. These procedures were revised and approved by the Manager, Technical Support - Nuclear on August 4, 198 Through interviews with licensee personnel, it was determined that the licensee's accountability program had been properly implemented, was operationally functional, and personnel were well trained in assigned function Schematics of new fuel storage locations are maintained by the licensee and periodically verified by the licensee to fulfill the requirement for an annual physical inventory of SNM. The licensee presently conducts inventory verifications on a more frequent time interval than require This is accomplished by giving inventory teams quadrant location schematics which the teams fill out during inventories. These are then compared to the master location schematic for verification of fuel assembly identification and locatio The quadrant schematics are dated and signed by performing inventory team Incore Detectors are accounted for by New Fuel Receiving Reports which bacome the perpetual inventory record. In addition to detectors in the reactor core, the licensee has 10 visually inspectable unirradiated detectors in an enclosed repository and several older irradiated detectors stored within enclosed steel pipes embedded in a concrete rad waste repository. The detectors, also referred to as fission chambers, which contain milligrar quantities of SNM and are portable, are accounted for by warehouse storage records, vessel position records and by Maintenance Work Requests for disposed of detectors which are dispositioned in the Additionally, the licensee possesses three additional
,
rad-waste wall .
incore detectors that are fixed in position and contain gram quantities of SNM that are accounted for on SNM card files and reported on DOE /NRC Form 742C, Physical Inventory Listing in accordance with NUREG/BR-0007, Part 2.
!
l
)
<
a
..
-
e _;
The inspector examined the licensee's inventory records for the past two
, . years and determined that inventories are being performed within the
frequency and the manner as described in his procedur :t' The licensee's Material Balance Report (Form DOE /NRC 742) was reviewed for the period ending October 30, 1986, to determine whether the report
'
accurately reflected quantities of special nuclear material received. The report was completed ir accordance with NUREG/BR-0007 and recorded data-
, including nuclear material depletion and production were found to be in-agreement with associated accountability records for fuel assemblies on
,
inventor s No violations or deviations were identifie .
,