05000295/LER-1978-085, Forwards LER 78-085/03L-0

From kanterella
Revision as of 00:20, 31 December 2020 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 78-085/03L-0
ML20204B521
Person / Time
Site: Zion File:ZionSolutions icon.png
Issue date: 09/26/1978
From: Wandke N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20204B526 List:
References
780929-02, 780929-2, NUDOCS 7810170225
Download: ML20204B521 (1)


LER-2078-085, Forwards LER 78-085/03L-0
Event date:
Report date:
2952078085R00 - NRC Website

text

_ _ __

~

J3. , % $as

. / C mmonw;cith Edisin

..,(

/ -

7 Zion Generating Station' c ' Shiloh Blvd. & Lake Michigan b/ ,

, N' ] Zion, Ulinois 60099 Telephono 312/746-2084 September 26, 1978 Mr. James G. Keppler  ;

Regional Director j Directorate of Regulatory Operations 1 Region III U. S. Nuclear Regulatory Commiccion Glen Ellyn, Illinois 60137 l

1

Reference:

Zion Generating Station Docket No. 50-295/DPR-39 Technical Specification, Section 6.6.2

Dear Mr. Keppler:

Enclosed, please find Reportable Occurrence Report No.

50-295/78-85 for Zion _ Generating Station.

This report is submitted to you in accordance with the re-quirements of the Technical Specifications, Section 6.6.2.b (2) ,

which states that conditions leading to operation in a degraded mode permittad by a limiting condition for operation or plant shutdown required by a limiting condition for operation requires a 30-day written report.

Very truly yours,

. El Wandke Superintendent Zion Station FR/sh

Enclosure:

Reportable Occurrence Report No. 50-295/78-85 3

f c., 2 71978 v

7f{ 6 / 7 O MLS f4y