Forwards Insp Repts 50-445/88-55 & 50-446/88-51 on 880803-0908.No Violations or Deviations Noted
ML20155A421
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 09/21/1988
From: Warnick R
NRC OFFICE OF SPECIAL PROJECTS
To: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML20155A425 List:
References
NUDOCS 8810050315
Download: ML20155A421 (4)


See also: IR 05000445/1988055

Text

.t

,. .

,

SEP 2 I Ic08

In Reply Refer To:

Dockets: 50-445/88-55

50-446/88-51

TU Electric

ATTN: Mr. W. G. Counsil

Executive Vice President

400 North Olive Street, Lock Box 81

Dallas, Texas 75201

Gentlemen:

This refers to the inspection conducted by Mr. C. Hale and NRC

consultants during the period August 3 through September 8, 1988,

cf activities authorized by NRC Construction Permits CPPR-126 and

CPPR-127 for the Comanche Peak Steam Electric Station, Units 1

and 2, and to the discussion of our findings with you and other

members of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas

examined during the inspection. Within these areas, the inspection

consisted of selective examination of procedures and representative

records, interviews with personnel, and observations by the

inspectors.

Within the scope of the inspection, no violations or deviations

were identified.

In accordance with 10 CFR 2.790 of the Commission's regulations, a

copy of this letter and the enclosed inspection report will be

placed in the NF? Public Document Room.

Should you have any questions concerning this inspection, we will

be pleased to discuss them with you.

Sincerely,

ORIGINAL SIGNED DY n, r, ytp.nmer

R. F. Warnick, Assistant Director

for Inspection Programs

Comancho Peak Project Division

Office of Special Projects

Enclosure:

Inspection Report 50-445/88-55; 50-446/88-51

cc w/ enclosure:

See next page

o

IP:CPedIpSP /IP:CPPD:OSP AD:IP:CPPD:OSP

CHalc # //f7' HLiveremore RWarnickgpd

SIEo,

9MLL /88 9/L//88 9/21/88

GS10050315 880921 'i

PDR ADOCK 05000445

Q PDC

_ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ - - - _ _ _ _ _ _ _ - _ _ _ _ . _ . _ _ _ _ _ _

1

... .

+* 'g UNITED STATES

[ p, NUCLEAR REGULATORY COMMISSION

5  ! WASHINGTON, D. C. 20666

%,,,,,J se o e

In Reply Refer To:

Dockets: 50-445/88-55

50-446/88-51

TU Electric

ATTN: Mr. W. G. Counsil

Executive Vice President

400 North Olive Street, Lock Box 81

Dallas, Texas 75201

Gentlemen:

i

This refers to the inspection conducted by Mr. C. Hale and NRC

consultants during the period August 3 through September 8, 1988,

of activities authorized by NRC Construction Permits CPPR-126 and

CPPR-127 for the Comanche Peak Steam Electric Station, Units 1

and 2, and to the discussion of our findings with you and other

members of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas

examined during the inspection. Within these areas, the inspection

consisted of selective examination of procedures and representative

,

records, interviews with personnel, and observations by the

inspectors.

Within the scope of the inspection, no violations or deviations

were identified.

In accordance with 10 CFR 2.790 of the Commission's regulations, a

copy of this letter and the enclosed inspection report will be

placed in the NRC Public Document Room.

Should you have any questions concerning this inspection, we will

be pleased to discuss them with you.

Sincerely,

R F105

R. F. Warnick, Assistant Director

for Inspection Programs

Comanche Peak Project Division

office of Special Projects

Enclosure:

Inspection Report 50-445/88-55: 50-446/88-51

cc w/ enclosure:

See next page

v' %

. _ _ _ _ _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _

  • t

"

TV Elcctric

cc w/ enclosure

Roger D. Walker Nancy H. Williams

Manager, Nuclear Licensing CYGNA Energy Services

TU Electric Suite 390

Skyway Tower 2121 N. California Blvd

400 North Olive Street, L.B. 81 Walnut Creek, CA 94596

Dallas, TX 75201

Robert A. Wooldridge, Esq.

Juanita Ellis Worsham, Forsythe, Sampels

President - CASE and Wooldridge

1426 South Polk Street 2001 Bryan Tower

Dallas, TX 75224 Suite 2500

Dallas, TX 75201

Susan M. Theisen

Assistant Attorney General Mr. Homer C. Schmidt

Environmental Protection Division Director of Nuclear

P.O. Box 12548, Capitol Station Services

Austin, TX 78711-1548 TU Electric

Skyway Tower

Jack R. Newman, Esq. 400 N. Olive St., L.B. 81

Newman & Holtzinger, P.C. Dallas, TX 75201

1615 L Street, NW, Suite 1000

Washington, D.C. 20036 Mr. J. L. Vota

Westinghouse Electric

GDS Associates, Inc. Corporation

1850 Parkway Place, Suite 720 Post Office Box 355

Marietta, GA 30067-8237 Pittsburgh, PA 15230

Mr. R. W. Ackley Lanny A. Sinkin

Stone & Webster Engineering Christic Institute

Corporation Project Mgr. 1324 N. Capitol Street

CPSES Washington, DC 20002

P. O. Box 1002

Glen Rose, Texas 76043 David R. Pigott, Esq.

Orrick, Herrington & Sutcliffe

Anthony Z. Roisman, Esq. 600 Montgomery Street

Suite 600 San Francisco, CA 94111

1401 New York Avenue, NW

Washington, DC 20005 Robert Jablon

Bonnie S. Blair

Ms. Billie Pirner Garce, Esq. Spiegel & McDiarmid

Government Accountability Project 1350 New York Avenue, NW

Midwest Office We.hington, DC 20005-4798

104 East Wisconsin Avenue

Appleton, WI 54911 TU Electric

c/o Bethesda Licensing

Regional Admitiistrator, Region IV 3 Metro Center, Suite 610

U.S. Nuclear Regulatory Commission Bethesda, MD 20814

611 Ryan Plaza Drive, Suite 1000

Arlington, Texas 76011

a t

    • * *

TU ElCctric

cc W/ enclosures (continued)

George A. Par).er, Chairman

Public Utility Committee

Senior citizens Alliance of

Tarrant County, Inc.

6048 Wonder Drive

Fort Worth, TX 76133 .

Joseph F. Fulbright

Fulbright & Jaworski

i

1301 McKinney Street

Houston, TX 77010  ;

William A. Burchette, Esq.

Counsel for Tex-La Electric

Cooperative of Texas

Heron, Burchette, Ruckert &

Rothwell

suite 700

1025 ' thomas Jef ferson St. , NW

1 Washington, DC 20007

.

I

f

I

!

f

)

!