_ _ _ _ _ - _. -

_===:::

e Log # TXX-99176

= File # 10010.1 C

C 905.2 (clo) 7t#ELECTR/C ef. # 10CFR50.55a(g)

R July 16,,&U9 C. Unmes 'Ihrvy Senior Hee PresMent

& PrincipalNuclear Oplcer U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 c_-

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)- UNIT 2 DOCKET NO. 50-446 m

SUBMITTAL OF UNIT 2 FOURTH REFUELING OUTAGE (2RF04)

INSERVICE INSPECTION (ISI)

SUMMARY

REPORT,1986 EDITION OF ASME CODE, SECTION XI, NO ADDENDA, AND CONTAINMENT

[

INSERVICE INSPECTION (CISI)

SUMMARY

REPORT,1992 EDITION L_

OF ASME SECTION XI 1992 ADDENDA This letter forwards the Inservice Inspection Summary Report for the fourth refueling outage of CPSES Unit 2, as Enclosure 1. Additionally, Enclosure 2 contains the g

Con ^ainment inservice inspection Summary Report for the fourth refueling outage of CPSES Unit 2. The enclosed reports are being provided to you pursuant to the ASME Boiler and Pressure Vessel Code,Section XI, paragraph IWA-6230.

A copy of these reports are also being forwarded to Mr. G. Bynog in accordance with

. the Texas Boller Law & Rules and Regulations, paragraph 65.100.g.4.

Please note that the Relief Request included in Appendix C of the Enclosure 1 is for i

information only. A formal request for relief has been submitted by a separate transmittal (TXX-99175, dated July 16,1999).

=

f 9907200177 990716 PDR ADOCK 05000446 G

PDR COMANCHE PEAK SIEAM EI.ECTRIC STATION P.O. Box 1002 Glen Rose. Texas 76043 1002

~

r l

TXX-99176 l.

Page 2 of 2 i

This communication contains no new licensing basis commitments regarding CPSES Unit 2. If you have any questions, please contact Obald Bhatty at (254) 897-5839.

Sincerely,

$s h, C. L. Terry By:

03L1r R6ger D. Walker Regulatory Affairs Manager OAB/oab Enclosures cc:

Mr. E. W. Merschoff, Region IV Mr. J. l. Tapia, Region IV (clo)

Resident inspector, CPSES Mr. D.H. Jaffe, NRR Mr. G. Bynog, TDLR Mr. J.C. Hair, ANIl

i ENCLOSURE 1 TO TXX-99176 INSERVICE INSPECTION

SUMMARY

REPORT FOR 2RF04 i

i i

4 1

i u