Mr. C. Lt.nc3 Terry July 23, 1999 Senior Vic) Pr:sident i
& Printip:1 Nucl:ar Offic:r TU Electric Attn: Regulatory Affairs Department P. O. Box 1002 Glen Rose, TX 76043
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES), UNITS 1 AND 2 -
EVALUATION OF RELLEF REQUESTS: USE OF 1998 EDITION OF SUBSECTIONS IWE AND IWL OF THE ASME CODE FOR CONTAINMENT INSPECTION (TAC NOS. MA2038 AND MA2039)
Dear Mr. Terry:
By letter dated February 20,1998, and suppleme ted by responses to Requests for Additional Information (RAls) in the letters dated March 26, June 8, and June 15,1999, Texas Utilities Electric Company (the licensee), submitted Requests for Relief Nos. E-1 and L-1, seeking relief from the requirements of Subsections IWE and IWL of the 1992 Edition and 1992 Addenda of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),
respectively. The relief requests propose to use the 1993 Edition of Subsections IWE and IWL of Section XI of the ASME Code for inspection of CPSES, Units 1 and 2, containments as an alternative to the 1992 Edition and Addenda cf the Code which is incorporated by reference in Title 10 of the Code of Federal Reaulations, Section 50.55a (10 CFR 50.55a) 10 CFR 50.55a.
The NRC staff, with assistance from the Idaho National Engineering and Environmental Laboratory (INEEL), has completed its review of the subject relief requests. The NRC staff's Safeiy Evaluation (SE) is enclosed herein; INEEL's Technical Evaluation Report is provided as an attachment to the SE.
Based on the review of the licensee's submittal and responses to the NRC staff's RAls, the NRC staff finds that the use of the 1998 Edition of the Code, supplemented by the licensee's commitments in the responses to the staff's RAls, will provide an acceptable level of quality and safety for ensuring the pressure integrity of the CPSES containments. Therefore, the staff concludes that the use of the proposed alternatives may be authorized for the first inspection interval of the containment pursuant to 10 CFR 50.55a(a)(3)(i).
Sincerely, ORIGINAL SIGNED BY David H. Jaffe, Senior Project Manager, Section 1 "O
9907200036 990723 PDR ADOCK 05000445 Division of Licensing Project Management P
PDR Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation b
"Q% hh Docket Nos. 50-445 and 50-446 1
I cc w/ encl: See next page DISTRIBUTION:
< Docket File!
PUBLIC S.Richards (cover ltr only)
D.Lange R.Scholl (RFS, SE only)
PD#1V-1 Reading KBrockman, RIV To receive a copy of this document, indicate "C" in the box PDlh<
PDIV-1/LA b OGC M PDIV-1/SC C
OFFICE DJath-LBerry k ddith//htn/)
RGramm M NAME DATE 3/ D l /Y /99
') /d/99
'7 /'Z3 /99 s'
/99 DOCUMENT NAME: G:\\P DIV-1 \\ Comanche Peak \\ rela 2038.wpd OFFICIAL RECORD COPY i
280001 J
1
e
.a, Comanche Peak Steam Electric Plant cc:
Senior Resident inspector Office of the Governor U.S. Nuclear Regulatory Commission ATTN: John Howard, Director P. O. Box 2159 Environmental and Natural Glen Rose, TX 76403-2159 Resources Policy P. O. Box 12428 Regional Administrator, Region IV Austin, TX 78711 U.S. Nuclear Regulatory Commiesion 611 Ryan Plaza Drive, Suite 400 Arthur C. Tate, Director Arlington, TX 76011 Division of Compliance & Inspection Bureau of Radiation Control Mrs. Juanita Ellis, President Texas Department of Health Citizens Association for Sound Energy 1100 West 49th Street l
1426 South Polk Austin, TX 78756-3189 Dallas, TX 75224 l
Mr. Roger D. Walker Public Utility Commission of Texas Regulatory Affairs Manager Electric Industry Analysis TU Electric P. O. Box 13326 P. O. Box 1002 Austin, TX 78711-3326 Glen Rose, TX 76043 George L. Edgar, Esq.
Morgan, Lewis & Bockius 1800 M Street, N.W.
Washington, DC 20036-5869 Honorable Dale McPherson County Judge P. O. Box 851 Glen Rose, TX 76043
)
l May 1999 1
3