ML20212G072

From kanterella
Jump to navigation Jump to search
Forwards Rev 4 to Augmented Inservice Insp Plan for CPSES, Unit 1. Future Changes & Revs to Unit 1 Augmented Inservice Insp Plan Will Be Available on Site
ML20212G072
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 09/24/1999
From: Terry C, Walker R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20212G078 List:
References
TXX-99221, NUDOCS 9909290075
Download: ML20212G072 (2)


Text

[ TXU TXU Electrk C. Lance Terry

Comanche Peak Senior Vice President & Principal Nuclear Officer Steam Electrk Station P.O. Box 1002 -

Glen Rose,TX 76043 Teh 254 897 8920 -

Fcx:254 897 6652 -

lterry1@txu.com Log # TXX-99221 File # 10010.1  !

Ref. # 10CFR50.55a(g) -

September 24,1999 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AUGMENTED INSERVICE INSPECTION PLAN FOR UNIT 1 l (UNIT 1: 1986 EDITION OF ASME CODE SECTION XI, NO  !

ADDENDA, INTERVAL START DATE - AUGUST 3,1993, FIRST l INTERVAL) l A current copy of the Unit 1 Augmented Inservice Inspection (AISI) Plan is provided  !

in Enclosure 1 for your information. Future changes and revisions to the Unit 1 AISI Plan will be available on site.

This communication contains no new licensing basis commitments regarding CPSES Units 1 and 2. k !

I i

&W

$ /Wh$f$1fbY '  !

9909290075 990924 PDR ADOCK 05000445 0 PDR;

p-()TXU TXX-99221 Page 2 of 2 l

Should you require additional infonnation please contact Obaid Bhatty at (254) 897-5839 to coordinate this effort.

Sincerely,

0. $ V C. L. Terry i

By: M '

Roger 6. Walker Regulatory Affairs Manager j OA.B/oab Enclosure i

cc: E. W. Merschoff, Region IV J. I. Tapia, Region IV l D. H. Jaffe, NRR Resident Inspectors, CPSES