ML20212A760

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-445/99-14 & 50-446/99-14 on 990707-0821.Four Violations Occurred & Being Treated as Ncvs.Conduct of Activities Was Generally Characterized by safety-conscious Operations & Sound Radiological Controls
ML20212A760
Person / Time
Site: Comanche Peak  
Issue date: 09/14/1999
From: Tapia J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Terry C
TEXAS UTILITIES CO.
Shared Package
ML20212A765 List:
References
50-445-99-14, 50-446-99-14, EA-99-200, NUDOCS 9909170124
Download: ML20212A760 (5)


See also: IR 05000445/1999014

Text

1

.

8 "'G%

UNITED STATES

'

5

h

'

NUCLEAR REGULATORY COMMISSION

i

p

,

,

E

REGloN IV

j

611 RYAN PLAZA DRIVE, sulTE 400

.,,,,

ARLINGTON, TEXAS 76011-8064

SEP 141999

EA 99-200

Mr. C. L. Terry

TU Electric

Senior, Vice President & Principal Nuclear Officer

ATTN: Regulatory Affairs Department

P.O. Box 1002

Glen Rose, Texas 76043

,

SUBJECT: NRC INSPECTION REPORT NO. 50-445/99-14; 50-446/99-14

Dear fdr. Terry:

This refers to the inspection conducted on July 7 through August 21,1999, at the Comanche

Peak Steam Electric Station, Units 1 and 2, facility. The enclosed report presents the results of

this inspection.

During the 6-week period covered by this inspection, your conduct of activities was generally

characterized by safety-conscious operations, sound radiological controls and maintenance,

and acceptable engineering.

Based on the results of this inspection, the NRC has determined that four Severity Level IV

violations of NRC requirements occurred. These violations are being treated as noncited

violations (NCVs), consistent with Appendix C of the Enforcement Policy. These NCVs are

described in the subject inspection report. if you contest the violation or severity level of these

NCVs, you should provide a response within 30 days of the date of this inspection report, with

'

the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control

Desk, Washington, DC 20555-0001, with copies to the Regional Administrator, U.S. Nuclear

Regulatory Commission, Region IV,611 Ryan Plaza Drive, Suite 400, Arlington, Texas 76011,

i

the Director, Office of Enforcement, United States Nuclear Regulatory Commission,

i

Washington, DC 20555-0001; and the NRC Resident inspector at the Comanche Peak Steam

Electric Station, Units 1 and 2, facility,

i

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter, its

I

enclosure, and your response, if requested, will be placed in the NRC Public Document

Room (PDR).

,

9909170124 990914

PDR

ADOCK 05000445

G

PDR

.

.

TU Electric

-2-

Should you have any questions concerning this inspection, we will be pleased to discuss them

with you.

Sincerely,

\\

<

h I. Tapia, C

f

Branch A

Division of Reactor Projects

Docket Nos.: 50-445

50-446

License Nos.: NPF-87

NPF-89

4

Enclosure:

NRC Inspection Report No.

50-445/99-14;50-446/99-14

cc w/ enclosure:

Roger D. Walker

TU Electric

Regulatory Affairs Manager

P.O. Box 1002

Glen Rose, Texas 76043

Juanita Ellis

President - CASE

1426 South Polk Street

Dallas, Texas 75224

I

- George L. Edgar, Esq.

Morgan, Lewis & Bockius

1800 M. Street, NW-

Washington, D.C. 20036

'

G. R. Bynog, Program Manager /

Chief Inspector

i

Texas Department of Licensing & Regulation

Boiler Division

P.O. Box 12157, Capitol Station

Austin, Texas 78711

-

.

.

' TU Electric

-3-

-

i

County Judge

. P.O. Box 851 -

Glen Rose, Texas 76043

Chief, Bureau of Radiation Control

Texas Department of Health--

1100 West 49th Street

Austin, Texas 78756-3189

'

~ John L. Howard, Director.

' Environmental and Natural Resources Policy

Office of the Governor -

P.O. Box 12428

Austin, Texas 78711-3189

,

I

L

.

!

l

,

1

..

.

TU Electric-

-4-

SEP 141999

"

' E-Mail report to T. Frye (TJF)

,

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E Mail report to Document Control Desk (DOCDESK)

E-Mail report to Richard Correia (RPC)

E-Mail report to Frank Talbot (FXT)

' bec to DCD (IE01)

bcc distrib by RIV:

Regional Administrator

Resident Inspector (2) .

DRP Director '

RIV File

DRS Director

RITS Coordinator

Branch Chief (DRP/A)

Project Engineer (DRP/A)

.

Branch Chief (DRP/TSS)

J

DOCUMENT NAME: R:\\_CPSES\\CP914RP.ATG

i

To receive copy of document, Indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" - No copy

'

Al:DRP/A

SRl:DRP/A

SRI:DRP/A

C:DRP/A p

SCSchwind % ATGody

p

NFO'Keefe g

JITapia Q[

_

9/IL)991ejlh,9/lC/99_hl W9/1%/99Ml

9/M /99 L l

,[

t

T

OFFICIAL RECORD COPY

~

'

-.

e

TU Electric

-4-

SEP 141999

E-Mail report to T. Frye (TJF)

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

E-Mail report to Richard Correia (RPC)

E Mail report to Frank Talbot (FXT)

bec to DCD (IE01)

bec distrib. by RIV:

Regional Administrator

Resident inspector (2)

DRP Director

RIV Filo

DRS Director'

RITS Coordinator

'

Branch Chief (DRP/A)

Project Engineer (DRP/A)

J

Branch Chief (DRP/TSS)

t

\\

DOCUMENT NAME: R:\\._CPSES\\CP914RP.ATG

To receive copy of document. Indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy

RI:DRP/A

SRl:DRP/A

SRI:DRP/A l

C:DRP/A p

_

SCSchwind % ATGody

p

NFO'Keefe g

JITapia Q[

,

9/gd1991dfh,9/llk/99 MM 9/l%/99MM

9/ b , /99 - )

,[

\\

\\

OFFICIAL RECORD COPY

~

170040-

i

)