-t Mr. C. Lancs Terry April 6, 1999
]
TU Electnc Senior Vice President & Principal Nuclear Officer 4
Attn: Regulatory Affairs Department -
P. O. Box 1002
{
Glen Rose, TX 76043 J
l
SUBJECT:
CLOSEOUT OF GENERIC LETTER 97-05, " STEAM GENERATOR TUBE i
' INSPECTION TECHNIQUES," FOR THE COMANCHE PEAK STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MA0456 AND MA0457) i L
Dear Mr. Terry:
l The Nuclear Regulatory Commission (NRC) staff has reviewed Texas Utilities Electric l
Company's (lic~ensee's) March 12,1998 (TXX-98009), submittal regarding Generic Letter (GL) 97-05, " Steam Generator Tube inspection Techniques." The licensee's submittal L
included a description and technical basis for all inspection techniques used to size the depth of steam generator tube degradation at Comanche Peak Steam Electric Station (CPSES), Units 1 and 2. The NRC staff's review of the licensee's submittal did not identify any concerns with the steam ger:erator inspection techniques employed at CPSES, Units 1 and 2, that would indicate the licensea is not in compliance with the current licensing basis for the facility.
l This completes the NRC staff's review of GL 97-05 for the CPSES, Units 1 and 2, and closes l
l TAC numbers MA0456 and MA0457.
i If you have further questions, please contact me at 301-415-1038.
l Sincerely, ORIGINAL SIGNED BY:
David H. Jaffe, Senior Project Manager, Section 1 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 l
cc: See next page l
l' DISTRIBUTION:
Docket File' OGC PUBLIC ~
Elmbro ACRS.
PDIV-1 r/f
^ KBrockman, RIV PRush SRichards -
ADromerick EMurphy -
. JZwolinski/SBlack g
h Document Name: G:\\CPFINAL\\LTRA0456.WPD OFC PDIV-1/PM PDIV-t/13 PDIV-1/S.C
]
1_Berryk NAME DJaffe/vw RGran
'f/h/99 N
/99 '
hh/99 DATE-hO COPY NO YES OFFICIAL RECORD COPY 99041N0143990406 3
PDR ADOCK 05000445 g
G PM s
{
f i
p uou J
g h
UNITED STATES
+
l s
j NUCLEAR REGULATORY COMMISSION 2
WASHINGTON, D.C. 2056H001 k*****/
4 April 6, 1999 l
Mr. C. Lance Terry TJ Electric l
Senior Vice President & Principal Nuclear Officer Attn: Regulatory Affairs Department P. O. Box 1002 Glen Rose, TX 76043
SUBJECT:
CLOSEOUT OF GENERIC LETTER 97-05," STEAM GENERATOR TUBE lNSPECTION TECHNIQUES," FOR THE COMANCHE PEAK STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MA0456 AND MA0457) l
Dear Mr. Terry:
The Nuclear Regulatory Commission (NRC) staff has reviewed Texas Utilities Electric Company's (ficensee's) March 12,1998 (TXX-98009), submittal regarding Generic Letter (GL) 97-05," Steam Generator Tube Inspection Techniques." The licensee's submittal included a description and technical basis for all inspection techniques used to size the depth of steam generator tube degradation at Comanche Peak Steam Electric Station (CPSES), Units 1 and 2. The NRC etaff's review of the licensee's submittal did not identify any concerns with the steam generator inspection techniques employed at CPSES, Units 1 and 2, that would indicate the licensee is not in compliance with the current licensing basis for the facility.
This completes the NRC staff's review of GL 97-05 for the CPSES, Units 1 and 2, and closes l
TAC numbers MA0456 and MA0457.
If you have further questions, please contact me at 301-415-1038.
Sincerely, f
\\~
y David H. affe, Senior Project Manager, Section 1 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation l
Docket Nos. 50-445 and 50-446 cc: See next page l
l l
l l
i I
e Mr. C. Lance Terry L
TU Electric Company Comanche Peak, Units 1 and 2 cc:
l Senior Resident inspector Honorable Dale McPherson U.S. Nuclear Regulatory Commission County Judge P. O. Box 2159 P. O. Box 851 l
Glen Rose, TX 76403-2159 Glen Rose,TX 76043 Regional Admin'istrator, Region IV Office of the Govemor U.S. Nuclear Regulatory Commission ATTN: John Howard, Director l
611 Ryan Plaza Drive, Suite 400 Environmental and Natural I
Arlington,TX 76011 Resources Policy -
P. O. Box 12428 Mrs. Juanita Ellis, President Austin,TX 78711 Citizens Association for Sound Energy 1426 South Polk Arthur C. Tate, Director Dallas,TX 75224 Division of Compliance & Inspection l
Bureau of Radiation Control Mr. Roger D. Walker Texas Department of Health TU Electric 1100 West 49th Street Regulatory Affairs Manager Austin, TX 78756-3189 P. O. Box 1002 Glen Rose, TX 76043 Jim Calloway Public Utility Commission of Texas
- George L. Edgar, Esq.
Electric Industry Analysis Morgan, Lewis & Bockius P. O. Box 13326 1800 M Street, N.W.
Austin, TX 78711-3326 Washington, DC 20036-5869 i
l l
i i
l
!