MONTHYEARIR 05000285/19990101999-10-15015 October 1999 Insp Rept 50-285/99-10 on 990913-17.One NCV Noted.Major Areas Inspected:Mitigating Sys,Reactor Safety IR 05000285/19990091999-10-14014 October 1999 Insp Rept 50-285/99-09 on 990913-17.No Violations Noted. Major Areas Inspected:Effective Implementation of Protective Strategy When Required to Respond to Contingency Events ML20211P3441999-09-0707 September 1999 Insp Rept 50-298/99-08 on 990711-0821.No Violations Noted. Major Areas Inspected:Initiating Events,Mitigating Systems & Barrier Integrity IR 05000285/19990061999-09-0303 September 1999 Insp Rept 50-285/99-06 on 990809-12.No Violations Noted. Major Areas Inspected:Cornerstone Area of Reactor Safety, Emergency Preparedness.Insp Included Review of Licensee Program for Problem Identification & Resolution IR 05000285/19990071999-08-13013 August 1999 Insp Rept 50-285/99-07 on 990719-23.No Violations Noted. Major Areas Inspected:Accuracy & Operability of Radiation Monitoring Instrumentation Used for Protection of Occupational Workers IR 05000285/19990051999-07-19019 July 1999 Insp Rept 50-285/99-05 on 990601-0710.No Violations Noted. Major Areas Inspected:Broad Categories of Reactor Safety, Emergency Preparedness & Other Activities ML20195J2591999-06-11011 June 1999 Insp Rept 50-285/99-04 on 990425-0531.Noncited Violations Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000285/19990031999-05-18018 May 1999 Insp Rept 50-285/99-03 on 990314-0424.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000285/19990021999-04-0202 April 1999 Insp Rept 50-285/99-02 on 990131-0313.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19990011999-03-11011 March 1999 Insp Rept 50-285/99-01 on 990208-26.One Noncited Violation Was Identified.Major Areas Inspected:Evaluation of Cumulative Effect of Operator Workarounds at Plant Reactor Facility IR 05000285/19980191999-01-0808 January 1999 Insp Rept 50-285/98-19 on 981005-23 & 1211.Violations Noted. Major Areas Inspected:Corrective Action Program in Identifying Evaluation,Correcting & Preventing Problems That Affect Safe Operation of Facility IR 05000285/19980231999-01-0707 January 1999 Insp Rept 50-285/98-23 on 981108-1219.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980251998-12-30030 December 1998 Insp Rept 50-285/98-25 on 981130-1204.No Violations Noted. Major Areas Inspected:Licensee Emergency Preparedness Program IR 05000285/19980261998-12-17017 December 1998 Insp Rept 50-285/98-26 on 981131-1204.Deviations Noted. Major Areas Inspected:Plant Support Activities IR 05000285/19980131998-12-16016 December 1998 Insp Rept 50-285/98-13 on 981130-1204.No Violations Noted. Major Areas Inspected:Review Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program IR 05000285/19980241998-11-20020 November 1998 Insp Rept 50-285/98-24 on 981102-06.Violations Noted.Major Areas Inspected:Plant Support IR 05000285/19980211998-11-13013 November 1998 Insp Rept 50-285/98-21 on 980927-1107.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980171998-10-28028 October 1998 Insp Rept 50-285/98-17 on 980928-1002.No Violations Noted. Major Areas Inspected:Licensee Operator Requalification Program to Determine Whether Program Incorporated Appropriate Requirements IR 05000285/19980181998-10-0808 October 1998 Insp Rept 50-285/98-18 on 980831-0902.No Violations Noted. Major Areas Inspected:Changes to Fort Calhoun Station Radiological Emergency Action Levels IR 05000285/19980201998-10-0505 October 1998 Insp Rept 50-285/98-20 on 980816-0926.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980221998-09-29029 September 1998 Insp Rept 50-285/98-22 on 980914-18.No Violations Noted. Major Areas Inspected:Routine,Announced Insp Reviewed Implementation of Radiological Environ & Meteorological Monitoring Programs IR 05000285/19980141998-08-28028 August 1998 Insp Rept 50-285/98-14 on 980705-0815.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980121998-08-17017 August 1998 Insp Rept 50-285/98-12 on 980601-05 (on Site) & 980811 (in Ofc).One Noncited Violation Noted.Major Areas Inspected: Operations,Maint & Engineering.Root Cause Assessment, Performed as Result of 980527 Pump FW-10 Occurrence IR 05000285/19980151998-08-0606 August 1998 Insp Rept 50-285/98-15 on 980727-31.No Violations Noted. Major Areas Inspected:Testing & Maint,Protected Area Barrier & Detection Aids,Vital Area Barriers & Detection Aids, Security Event Logs & Security Training & Qualifications IR 05000285/19980161998-07-29029 July 1998 Insp Rept 50-285/98-16 on 980706-10.Violations Noted.Major Areas Inpected:Solid Radwaste Mgt & Radioactive Matls Transportations,Associated Training Activities & QA Oversight IR 05000285/19980101998-07-21021 July 1998 Insp Rept 50-285/98-10 on 970524-0704.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236M7581998-07-0808 July 1998 Insp Rept 50-285/98-11 on 980521-0605.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980091998-06-25025 June 1998 Errata to Insp Rept 50-285/98-09.Correction Due to Errrors on Pages 5 & 13 ML20249A6181998-06-15015 June 1998 Insp Rept 50-285/98-09 on 980412-0523.Violations Noted:Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980071998-05-24024 May 1998 Insp Rept 50-285/98-07 on 980415-24.Violations Noted.Major Areas Inspected:Operations & Maint ML20217N0991998-04-30030 April 1998 Insp Rept 50-285/98-06 on 980406-10.Violations Noted.Major Areas Inspected:Plant Support IR 05000285/19980051998-04-22022 April 1998 Insp Rept 50-285/98-05 on 980301-0411.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20217Q9251998-04-0606 April 1998 Insp Rept 50-285/98-01 on 980120-23 & 26-0306.No Violations Noted.Major Areas Inspected:Plant Support,Including Fire Protection Program IR 05000285/19980031998-03-27027 March 1998 Insp Rept 50-285/98-03 on 980223-27 & 0311-18.No Violations Identified.Major Areas Inspected:Licensee Physical Security Program,Access Authorization,Alarm Stations,Communications, Access Control of Event Logs & Mgt Support IR 05000285/19980021998-03-25025 March 1998 Insp Rept 50-285/98-02 on 980209-13 W/In Ofc Insp Until 980302.Violations Noted.Major Areas Inspected:Operations & Engineering IR 05000285/19980041998-03-12012 March 1998 Insp Rept 50-285/98-04 on 980118-0228.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203K5991998-02-27027 February 1998 Errata to Insp Rept 50-285/97-20 Issued on 980128.Noncited Violation Withdrawn.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20199H8611998-01-28028 January 1998 Insp Rept 50-285/97-20 on 971207-980117.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20197H0171997-12-19019 December 1997 Insp Rept 50-285/97-19 on 971026-1206.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19970141997-11-18018 November 1997 Informs That Insp Rept 50-285/97-14 Has Been Cancelled.No Insp Rept Will Be Issued for Rept Number IR 05000285/19970181997-11-10010 November 1997 Insp Rept 50-285/97-18 on 970914-1025.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19970131997-10-0202 October 1997 Insp Rept 50-285/97-13 on 970630-0718.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19970161997-09-29029 September 1997 Insp Rept 50-285/97-16 on 970803-0913.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000285/19970171997-09-19019 September 1997 Insp Rept 50-285/97-17 on 970825-29.Violations Being Considered for Escalated Ea.Major Areas Inspected: Operations & Engineering ML20141J8891997-08-15015 August 1997 Insp Rept 50-285/97-15 on 970615-0802.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Fire Sprinkler Sys IR 05000285/19970051997-08-0101 August 1997 Insp Rept 50-285/97-05 on 970714-18.No Violations Noted. Major Areas Inspected:Plant Support IR 05000285/19970121997-07-25025 July 1997 Paritally Withheld Insp Rept 50-285/97-12 on 970623-0710 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected: Licensee Implementation of Land Vehicle Control Measures & Security Surveillance IR 05000285/19970041997-07-0202 July 1997 Insp Rept 50-285/97-04 on 970602-06.Unresolved Items Identified.Major Areas Inspected:Licensee Performance & Capabilities in Control Room Simulator,Technical Support Ctr,Operations Support Ctr & Emergency Operations Facility ML20141E2441997-06-27027 June 1997 Insp Rept 50-285/97-06 on 970414-18 & 0428-0502.Violations Noted.Major Areas Inspected:Current Effectiveness of Licensee Plant & Design Engineering Organizations to Respond to Routine & Reactive Site Activities IR 05000285/19970101997-06-20020 June 1997 Insp Rept 50-285/97-10 on 970504-0614.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-09-07
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000285/19990101999-10-15015 October 1999 Insp Rept 50-285/99-10 on 990913-17.One NCV Noted.Major Areas Inspected:Mitigating Sys,Reactor Safety IR 05000285/19990091999-10-14014 October 1999 Insp Rept 50-285/99-09 on 990913-17.No Violations Noted. Major Areas Inspected:Effective Implementation of Protective Strategy When Required to Respond to Contingency Events ML20211P3441999-09-0707 September 1999 Insp Rept 50-298/99-08 on 990711-0821.No Violations Noted. Major Areas Inspected:Initiating Events,Mitigating Systems & Barrier Integrity IR 05000285/19990061999-09-0303 September 1999 Insp Rept 50-285/99-06 on 990809-12.No Violations Noted. Major Areas Inspected:Cornerstone Area of Reactor Safety, Emergency Preparedness.Insp Included Review of Licensee Program for Problem Identification & Resolution IR 05000285/19990071999-08-13013 August 1999 Insp Rept 50-285/99-07 on 990719-23.No Violations Noted. Major Areas Inspected:Accuracy & Operability of Radiation Monitoring Instrumentation Used for Protection of Occupational Workers IR 05000285/19990051999-07-19019 July 1999 Insp Rept 50-285/99-05 on 990601-0710.No Violations Noted. Major Areas Inspected:Broad Categories of Reactor Safety, Emergency Preparedness & Other Activities ML20195J2591999-06-11011 June 1999 Insp Rept 50-285/99-04 on 990425-0531.Noncited Violations Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000285/19990031999-05-18018 May 1999 Insp Rept 50-285/99-03 on 990314-0424.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000285/19990021999-04-0202 April 1999 Insp Rept 50-285/99-02 on 990131-0313.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19990011999-03-11011 March 1999 Insp Rept 50-285/99-01 on 990208-26.One Noncited Violation Was Identified.Major Areas Inspected:Evaluation of Cumulative Effect of Operator Workarounds at Plant Reactor Facility IR 05000285/19980191999-01-0808 January 1999 Insp Rept 50-285/98-19 on 981005-23 & 1211.Violations Noted. Major Areas Inspected:Corrective Action Program in Identifying Evaluation,Correcting & Preventing Problems That Affect Safe Operation of Facility IR 05000285/19980231999-01-0707 January 1999 Insp Rept 50-285/98-23 on 981108-1219.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980251998-12-30030 December 1998 Insp Rept 50-285/98-25 on 981130-1204.No Violations Noted. Major Areas Inspected:Licensee Emergency Preparedness Program IR 05000285/19980261998-12-17017 December 1998 Insp Rept 50-285/98-26 on 981131-1204.Deviations Noted. Major Areas Inspected:Plant Support Activities IR 05000285/19980131998-12-16016 December 1998 Insp Rept 50-285/98-13 on 981130-1204.No Violations Noted. Major Areas Inspected:Review Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program IR 05000285/19980241998-11-20020 November 1998 Insp Rept 50-285/98-24 on 981102-06.Violations Noted.Major Areas Inspected:Plant Support IR 05000285/19980211998-11-13013 November 1998 Insp Rept 50-285/98-21 on 980927-1107.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980171998-10-28028 October 1998 Insp Rept 50-285/98-17 on 980928-1002.No Violations Noted. Major Areas Inspected:Licensee Operator Requalification Program to Determine Whether Program Incorporated Appropriate Requirements IR 05000285/19980181998-10-0808 October 1998 Insp Rept 50-285/98-18 on 980831-0902.No Violations Noted. Major Areas Inspected:Changes to Fort Calhoun Station Radiological Emergency Action Levels IR 05000285/19980201998-10-0505 October 1998 Insp Rept 50-285/98-20 on 980816-0926.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980221998-09-29029 September 1998 Insp Rept 50-285/98-22 on 980914-18.No Violations Noted. Major Areas Inspected:Routine,Announced Insp Reviewed Implementation of Radiological Environ & Meteorological Monitoring Programs IR 05000285/19980141998-08-28028 August 1998 Insp Rept 50-285/98-14 on 980705-0815.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980121998-08-17017 August 1998 Insp Rept 50-285/98-12 on 980601-05 (on Site) & 980811 (in Ofc).One Noncited Violation Noted.Major Areas Inspected: Operations,Maint & Engineering.Root Cause Assessment, Performed as Result of 980527 Pump FW-10 Occurrence IR 05000285/19980151998-08-0606 August 1998 Insp Rept 50-285/98-15 on 980727-31.No Violations Noted. Major Areas Inspected:Testing & Maint,Protected Area Barrier & Detection Aids,Vital Area Barriers & Detection Aids, Security Event Logs & Security Training & Qualifications IR 05000285/19980161998-07-29029 July 1998 Insp Rept 50-285/98-16 on 980706-10.Violations Noted.Major Areas Inpected:Solid Radwaste Mgt & Radioactive Matls Transportations,Associated Training Activities & QA Oversight IR 05000285/19980101998-07-21021 July 1998 Insp Rept 50-285/98-10 on 970524-0704.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236M7581998-07-0808 July 1998 Insp Rept 50-285/98-11 on 980521-0605.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980091998-06-25025 June 1998 Errata to Insp Rept 50-285/98-09.Correction Due to Errrors on Pages 5 & 13 ML20249A6181998-06-15015 June 1998 Insp Rept 50-285/98-09 on 980412-0523.Violations Noted:Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980071998-05-24024 May 1998 Insp Rept 50-285/98-07 on 980415-24.Violations Noted.Major Areas Inspected:Operations & Maint ML20217N0991998-04-30030 April 1998 Insp Rept 50-285/98-06 on 980406-10.Violations Noted.Major Areas Inspected:Plant Support IR 05000285/19980051998-04-22022 April 1998 Insp Rept 50-285/98-05 on 980301-0411.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20217Q9251998-04-0606 April 1998 Insp Rept 50-285/98-01 on 980120-23 & 26-0306.No Violations Noted.Major Areas Inspected:Plant Support,Including Fire Protection Program IR 05000285/19980031998-03-27027 March 1998 Insp Rept 50-285/98-03 on 980223-27 & 0311-18.No Violations Identified.Major Areas Inspected:Licensee Physical Security Program,Access Authorization,Alarm Stations,Communications, Access Control of Event Logs & Mgt Support IR 05000285/19980021998-03-25025 March 1998 Insp Rept 50-285/98-02 on 980209-13 W/In Ofc Insp Until 980302.Violations Noted.Major Areas Inspected:Operations & Engineering IR 05000285/19980041998-03-12012 March 1998 Insp Rept 50-285/98-04 on 980118-0228.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203K5991998-02-27027 February 1998 Errata to Insp Rept 50-285/97-20 Issued on 980128.Noncited Violation Withdrawn.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20199H8611998-01-28028 January 1998 Insp Rept 50-285/97-20 on 971207-980117.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20197H0171997-12-19019 December 1997 Insp Rept 50-285/97-19 on 971026-1206.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19970141997-11-18018 November 1997 Informs That Insp Rept 50-285/97-14 Has Been Cancelled.No Insp Rept Will Be Issued for Rept Number IR 05000285/19970181997-11-10010 November 1997 Insp Rept 50-285/97-18 on 970914-1025.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19970131997-10-0202 October 1997 Insp Rept 50-285/97-13 on 970630-0718.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19970161997-09-29029 September 1997 Insp Rept 50-285/97-16 on 970803-0913.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000285/19970171997-09-19019 September 1997 Insp Rept 50-285/97-17 on 970825-29.Violations Being Considered for Escalated Ea.Major Areas Inspected: Operations & Engineering ML20141J8891997-08-15015 August 1997 Insp Rept 50-285/97-15 on 970615-0802.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Fire Sprinkler Sys IR 05000285/19970051997-08-0101 August 1997 Insp Rept 50-285/97-05 on 970714-18.No Violations Noted. Major Areas Inspected:Plant Support IR 05000285/19970121997-07-25025 July 1997 Paritally Withheld Insp Rept 50-285/97-12 on 970623-0710 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected: Licensee Implementation of Land Vehicle Control Measures & Security Surveillance IR 05000285/19970041997-07-0202 July 1997 Insp Rept 50-285/97-04 on 970602-06.Unresolved Items Identified.Major Areas Inspected:Licensee Performance & Capabilities in Control Room Simulator,Technical Support Ctr,Operations Support Ctr & Emergency Operations Facility ML20141E2441997-06-27027 June 1997 Insp Rept 50-285/97-06 on 970414-18 & 0428-0502.Violations Noted.Major Areas Inspected:Current Effectiveness of Licensee Plant & Design Engineering Organizations to Respond to Routine & Reactive Site Activities IR 05000285/19970101997-06-20020 June 1997 Insp Rept 50-285/97-10 on 970504-0614.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-09-07
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000285/19990101999-10-15015 October 1999 Insp Rept 50-285/99-10 on 990913-17.One NCV Noted.Major Areas Inspected:Mitigating Sys,Reactor Safety IR 05000285/19990091999-10-14014 October 1999 Insp Rept 50-285/99-09 on 990913-17.No Violations Noted. Major Areas Inspected:Effective Implementation of Protective Strategy When Required to Respond to Contingency Events ML20211P3441999-09-0707 September 1999 Insp Rept 50-298/99-08 on 990711-0821.No Violations Noted. Major Areas Inspected:Initiating Events,Mitigating Systems & Barrier Integrity IR 05000285/19990061999-09-0303 September 1999 Insp Rept 50-285/99-06 on 990809-12.No Violations Noted. Major Areas Inspected:Cornerstone Area of Reactor Safety, Emergency Preparedness.Insp Included Review of Licensee Program for Problem Identification & Resolution IR 05000285/19990071999-08-13013 August 1999 Insp Rept 50-285/99-07 on 990719-23.No Violations Noted. Major Areas Inspected:Accuracy & Operability of Radiation Monitoring Instrumentation Used for Protection of Occupational Workers IR 05000285/19990051999-07-19019 July 1999 Insp Rept 50-285/99-05 on 990601-0710.No Violations Noted. Major Areas Inspected:Broad Categories of Reactor Safety, Emergency Preparedness & Other Activities ML20195J2591999-06-11011 June 1999 Insp Rept 50-285/99-04 on 990425-0531.Noncited Violations Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000285/19990031999-05-18018 May 1999 Insp Rept 50-285/99-03 on 990314-0424.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000285/19990021999-04-0202 April 1999 Insp Rept 50-285/99-02 on 990131-0313.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19990011999-03-11011 March 1999 Insp Rept 50-285/99-01 on 990208-26.One Noncited Violation Was Identified.Major Areas Inspected:Evaluation of Cumulative Effect of Operator Workarounds at Plant Reactor Facility IR 05000285/19980191999-01-0808 January 1999 Insp Rept 50-285/98-19 on 981005-23 & 1211.Violations Noted. Major Areas Inspected:Corrective Action Program in Identifying Evaluation,Correcting & Preventing Problems That Affect Safe Operation of Facility IR 05000285/19980231999-01-0707 January 1999 Insp Rept 50-285/98-23 on 981108-1219.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980251998-12-30030 December 1998 Insp Rept 50-285/98-25 on 981130-1204.No Violations Noted. Major Areas Inspected:Licensee Emergency Preparedness Program IR 05000285/19980261998-12-17017 December 1998 Insp Rept 50-285/98-26 on 981131-1204.Deviations Noted. Major Areas Inspected:Plant Support Activities IR 05000285/19980131998-12-16016 December 1998 Insp Rept 50-285/98-13 on 981130-1204.No Violations Noted. Major Areas Inspected:Review Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program IR 05000285/19980241998-11-20020 November 1998 Insp Rept 50-285/98-24 on 981102-06.Violations Noted.Major Areas Inspected:Plant Support IR 05000285/19980211998-11-13013 November 1998 Insp Rept 50-285/98-21 on 980927-1107.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980171998-10-28028 October 1998 Insp Rept 50-285/98-17 on 980928-1002.No Violations Noted. Major Areas Inspected:Licensee Operator Requalification Program to Determine Whether Program Incorporated Appropriate Requirements IR 05000285/19980181998-10-0808 October 1998 Insp Rept 50-285/98-18 on 980831-0902.No Violations Noted. Major Areas Inspected:Changes to Fort Calhoun Station Radiological Emergency Action Levels IR 05000285/19980201998-10-0505 October 1998 Insp Rept 50-285/98-20 on 980816-0926.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980221998-09-29029 September 1998 Insp Rept 50-285/98-22 on 980914-18.No Violations Noted. Major Areas Inspected:Routine,Announced Insp Reviewed Implementation of Radiological Environ & Meteorological Monitoring Programs IR 05000285/19980141998-08-28028 August 1998 Insp Rept 50-285/98-14 on 980705-0815.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980121998-08-17017 August 1998 Insp Rept 50-285/98-12 on 980601-05 (on Site) & 980811 (in Ofc).One Noncited Violation Noted.Major Areas Inspected: Operations,Maint & Engineering.Root Cause Assessment, Performed as Result of 980527 Pump FW-10 Occurrence IR 05000285/19980151998-08-0606 August 1998 Insp Rept 50-285/98-15 on 980727-31.No Violations Noted. Major Areas Inspected:Testing & Maint,Protected Area Barrier & Detection Aids,Vital Area Barriers & Detection Aids, Security Event Logs & Security Training & Qualifications IR 05000285/19980161998-07-29029 July 1998 Insp Rept 50-285/98-16 on 980706-10.Violations Noted.Major Areas Inpected:Solid Radwaste Mgt & Radioactive Matls Transportations,Associated Training Activities & QA Oversight IR 05000285/19980101998-07-21021 July 1998 Insp Rept 50-285/98-10 on 970524-0704.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236M7581998-07-0808 July 1998 Insp Rept 50-285/98-11 on 980521-0605.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980091998-06-25025 June 1998 Errata to Insp Rept 50-285/98-09.Correction Due to Errrors on Pages 5 & 13 ML20249A6181998-06-15015 June 1998 Insp Rept 50-285/98-09 on 980412-0523.Violations Noted:Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980071998-05-24024 May 1998 Insp Rept 50-285/98-07 on 980415-24.Violations Noted.Major Areas Inspected:Operations & Maint ML20217N0991998-04-30030 April 1998 Insp Rept 50-285/98-06 on 980406-10.Violations Noted.Major Areas Inspected:Plant Support IR 05000285/19980051998-04-22022 April 1998 Insp Rept 50-285/98-05 on 980301-0411.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20217Q9251998-04-0606 April 1998 Insp Rept 50-285/98-01 on 980120-23 & 26-0306.No Violations Noted.Major Areas Inspected:Plant Support,Including Fire Protection Program IR 05000285/19980031998-03-27027 March 1998 Insp Rept 50-285/98-03 on 980223-27 & 0311-18.No Violations Identified.Major Areas Inspected:Licensee Physical Security Program,Access Authorization,Alarm Stations,Communications, Access Control of Event Logs & Mgt Support IR 05000285/19980021998-03-25025 March 1998 Insp Rept 50-285/98-02 on 980209-13 W/In Ofc Insp Until 980302.Violations Noted.Major Areas Inspected:Operations & Engineering IR 05000285/19980041998-03-12012 March 1998 Insp Rept 50-285/98-04 on 980118-0228.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20203K5991998-02-27027 February 1998 Errata to Insp Rept 50-285/97-20 Issued on 980128.Noncited Violation Withdrawn.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20199H8611998-01-28028 January 1998 Insp Rept 50-285/97-20 on 971207-980117.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20197H0171997-12-19019 December 1997 Insp Rept 50-285/97-19 on 971026-1206.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19970141997-11-18018 November 1997 Informs That Insp Rept 50-285/97-14 Has Been Cancelled.No Insp Rept Will Be Issued for Rept Number IR 05000285/19970181997-11-10010 November 1997 Insp Rept 50-285/97-18 on 970914-1025.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19970131997-10-0202 October 1997 Insp Rept 50-285/97-13 on 970630-0718.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19970161997-09-29029 September 1997 Insp Rept 50-285/97-16 on 970803-0913.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000285/19970171997-09-19019 September 1997 Insp Rept 50-285/97-17 on 970825-29.Violations Being Considered for Escalated Ea.Major Areas Inspected: Operations & Engineering ML20141J8891997-08-15015 August 1997 Insp Rept 50-285/97-15 on 970615-0802.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Fire Sprinkler Sys IR 05000285/19970051997-08-0101 August 1997 Insp Rept 50-285/97-05 on 970714-18.No Violations Noted. Major Areas Inspected:Plant Support IR 05000285/19970121997-07-25025 July 1997 Paritally Withheld Insp Rept 50-285/97-12 on 970623-0710 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected: Licensee Implementation of Land Vehicle Control Measures & Security Surveillance IR 05000285/19970041997-07-0202 July 1997 Insp Rept 50-285/97-04 on 970602-06.Unresolved Items Identified.Major Areas Inspected:Licensee Performance & Capabilities in Control Room Simulator,Technical Support Ctr,Operations Support Ctr & Emergency Operations Facility ML20141E2441997-06-27027 June 1997 Insp Rept 50-285/97-06 on 970414-18 & 0428-0502.Violations Noted.Major Areas Inspected:Current Effectiveness of Licensee Plant & Design Engineering Organizations to Respond to Routine & Reactive Site Activities IR 05000285/19970101997-06-20020 June 1997 Insp Rept 50-285/97-10 on 970504-0614.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-09-07
[Table view] Category:UTILITY
MONTHYEARIR 05000285/19900421990-11-0707 November 1990 Insp Rept 50-285/90-42 on 901015-19.No Violation or Deviations Noted.Major Areas Inspected:Events Re Engineering Ongoing Design Basis Reconstitution Effort IR 05000285/19900351990-09-25025 September 1990 Insp Rept 50-285/90-35 on 900729-0910.No Violations or Deviations Noted.Major Areas Inspected:Operational Safety Verification,Monthly Maint,Surveillance,Security & Radiological Protection Observations IR 05000285/19900341990-08-16016 August 1990 Insp Rept 50-285/90-34 on 900730-0803.Fire Protection/ Prevention Program Satisfatory.Unresolved Item Re Proper Fire Rating Noted.Major Areas Inspected:Fire Protection/ Prevention Program & Emergency Diesel Generator Problems IR 05000285/19900331990-08-15015 August 1990 Advises That Insp Rept 50-285/90-33 Canceled.No Rept Will Be Issued for Rept Number IR 05000285/19900301990-07-24024 July 1990 Insp Rept 50-285/90-30 on 900513-0616.No Violations Noted. Major Areas Inspected:Monthly Maint,Surveillance,Security, Complex Surveillance Observation,Review of Licensee Outage Plans & Verification of Containment Integrity IR 05000285/19900311990-07-13013 July 1990 Informs That Insp 50-285/90-31 Canceled.No Insp Rept Will Be Issued IR 05000285/19900261990-06-15015 June 1990 Insp Rept 50-285/90-26 on 900416-0512.Noncited Violations Noted.Major Areas Inspected:Operational Safety Verification, Monthly Maint,Surveillance,Security & Onsite Followup of Events & in-ofc Review of Repts IR 05000285/19900251990-06-12012 June 1990 Partially Withheld Insp Rept 50-285/90-25 on 900402-06 & 16- 19 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected: Physical Security Program,Including Previous Insp Findings, Security Plan,Testing & Maint,Locks,Keys & Combinations IR 05000285/19890321989-09-27027 September 1989 Insp Rept 50-285/89-32 on 890801-31.Violations Noted.Major Areas Inspected:Ler Followup,Operational Safety Verification,Plant Tours,Monthly Maint Observations,Monthly Surveillance Observations & Security Observations ML20246F0811989-08-23023 August 1989 Insp Rept 50-285/89-30 on 890724-28.No Violations or Deviations Noted.Major Areas Inspected:Implementation of Corrective Actions in Response to NRC Bulletin 87-002 Concerning Fastener Testing IR 05000285/19890281989-08-23023 August 1989 Insp Rept 50-285/89-28 on 890701-31.No Violations or Deviations Noted.Major Areas Inspected:Review of Previously Identified Items,Ler Followup,Operational Safety Verification,Plant Tours & Monthly Maint Observations IR 05000285/19890261989-07-24024 July 1989 Insp Rept 50-285/89-26 on 890601-30.Violations & Deviations Noted.Major Areas Inspected:Review of Previously Identified Items,Ler Followup,Operational Safety Verification,Plant Tours,Security Observations & Monthly Maint Observations IR 05000285/19890271989-07-10010 July 1989 Insp Rept 50-285/89-27 on 890622-23.Violations Noted.Major Areas Inspected:Testing of Turbine Driven Auxiliary Feedwater Pump ML20246N0751989-07-0606 July 1989 Insp Rept 50-285/89-01 on 890313-31 & 0417-21.Violations Noted.Major Areas Inspected:Exams of Work Control Procedures & Representative Records,Interviews & Observations of Work in Progress by NRC Inspectors IR 05000285/19890251989-06-26026 June 1989 Insp Rept 50-285/89-25 on 890605-09.No Violations or Deviations Noted.Major Areas Inspected:Licensee Chemistry/Radiochemistry Program & Water Chemistry & Radiochemistry Confirmatory Measurements IR 05000285/19890231989-06-16016 June 1989 Partially Withheld Insp Rept 50-285/89-23 on 890508-10 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program,Including Mgt Support, Security Program Audits & Vital Area Barriers ML20245C9331989-06-15015 June 1989 Insp Rept 50-285/89-22 on 890501-31.Violations Noted.Major Areas Inspected:Ler Followup,Operational Safety Verification,Plant Tours,Monthly Maint Observations,Monthly Surveillance Observations & Security Observations IR 05000285/19890201989-06-14014 June 1989 Assessment Rept 50-285/89-20 on 890417-21 & 0502.Concerns Noted Re Util Steps to Institutionalize Aspects of Safety Enhancement Program.Overall Improvement Demonstrated ML20244C0901989-06-0202 June 1989 Insp Rept 50-285/89-24 on 890508-12.No Violations or Deviations Noted.Major Areas Inspected:Operational Status of Emergency Preparedness Program,Including Changes to Emergency Plan & Implementing Procedures & Supplies IR 05000285/19890171989-06-0101 June 1989 Insp Rept 50-285/89-17 on 890401-30.No Violations Noted. Major Areas Inspected:Operational Safety Verification,Plant Tours,Monthly Maint & Surveillance Observations,Security Observations & Radiological Protection Observations IR 05000285/19890211989-05-23023 May 1989 Insp Rept 50-285/89-21 on 890417-21.No Violations Noted. Major Areas Inspected:Facility Mods & Training & Licensed Operator & Nonlicensed Staff Training ML20247K4771989-05-17017 May 1989 Insp Rept 50-285/89-13 on 890301-31.Violations Noted.Major Areas Inspected:Review of Previously Identified Items,Ler Followup,Operational Safety Verification,Plant Tours, safety-related Sys Walkdown & Monthly Maint Observations IR 05000285/19890181989-05-15015 May 1989 Cancels Insp Rept 50-285/89-18 IR 05000285/19890161989-05-0404 May 1989 Partially Withheld Insp Rept 50-285/89-16 on 890327-31 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program,Including Mgt Support, Safety Enhancement Plan,Audits & Vital Area Barriers IR 05000285/19890151989-04-14014 April 1989 Insp Rept 50-285/89-15 on 890403-07.No Violations or Deviations Noted.Major Areas Inspected:Startup Testing After Refueling & Followup to Previous Insp Findings IR 05000285/19890091989-03-24024 March 1989 Insp Rept 50-285/89-09 on 890201-28.Violations & Deviations Noted.Major Areas Inspected:Ler Followup,Operational Safety Verification,Plant Tours,Monthly Maint & Surveillance Observations & Security Observations IR 05000285/19890111989-03-23023 March 1989 Insp Rept 50-285/89-11 on 890227-0303.No Violations Noted. Major Areas Inspected:Liquid & Gaseous Radwaste Mgt Programs IR 05000285/19890101989-03-21021 March 1989 Partially Withheld Insp Rept 50-285/89-10 on 890227-0303 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected: Physical Security Program,Including Mgt Support & Security Program Audits & Security Training & Qualifications ML20236A1751989-03-0707 March 1989 Insp Rept 50-285/89-12 on 890221-24.No Violations or Deviations Noted.Major Areas inspected:post-mod Testing & Followup on Main Steam Safety Valve Issue ML20235Y7561989-03-0303 March 1989 Insp Rept 50-285/89-05 on 890130-0203.Violation Noted.Major Areas Inspected:Previously Identified Insp Findings, Implementation of ATWS Requirements & LERs ML20235U4431989-02-27027 February 1989 Insp Rept 50-285/89-03 on 890101-31.Violation Noted.Major Areas Inspected:Previously Identified Items,Ler Followup, Operational Safety Verification,Plant Tours,Monthly Maint Observations & Monthly Surveillance Observations ML20235M5171989-02-17017 February 1989 Insp Rept 50-285/89-08 on 890206-10.Violations Noted.Major Areas Inspected:Licensee Actions on Previous Insp Findings IR 05000285/19890021989-02-15015 February 1989 Insp Rept 50-285/89-02 on 890130-0203.Violations Noted. Major Areas Inspected:Low Power Physics Testing,Complex Surveillance & Reactor Thermal Shield Sway Test Results ML20235K1421989-02-14014 February 1989 Insp Rept 50-285/89-04 on 890117-20.Four Apparent Violations Noted.Major Areas Inspected:Allegation Re High Radiation Area Incident on 890126 IR 05000285/19880431988-12-0101 December 1988 Insp Rept 50-285/88-43 on 881114-18.One Violation & Unresolved Item Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings & Structural Welding Activities IR 05000285/19880341988-11-14014 November 1988 Insp Rept 50-285/88-34 on 881016-21.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program Activities Associated W/Current Refueling Outage & Allegations Re Conduct of Radiation Protection Program IR 05000285/19880371988-11-0303 November 1988 Insp Rept 50-285/88-37 on 881017-21.Violation Noted.Major Areas Inspected:Design Changes & Mods,Receipt,Storage & Handling of Equipment & Matls & Measuring & Test Equipment IR 05000285/19880321988-11-0303 November 1988 Insp Rept 50-285/88-32 on 880901-30.Violation Noted.Major Areas Inspected:Followup on Previously Identified Items, Operational Safety Verification,Plant Tours,Monthly Maint Observations & Security Observations ML20206B9641988-11-0303 November 1988 Insp Rept 50-285/88-37 on 881017-21.Violation Noted.Major Areas Inspected:Design Changes & Mods,Receipt,Storage & Handling of Equipment & Matls & Measuring & Test Equipment IR 05000285/19880401988-11-0202 November 1988 Insp Rept 50-285/88-40 on 881024-28.Violation Noted.Major Areas Inspected:Welding & NDE Activities IR 05000285/19880381988-10-26026 October 1988 Partially Withheld Insp Rept 50-285/88-38 on 881004-14 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected: Security Observations IR 05000285/19880311988-10-18018 October 1988 Insp Rept 50-285/88-31 on 880912-16.Violations & Deviations Noted.Major Areas Inspected:Action on Previous Insp Findings,Welding,Design Changes & Mods,Procurement & Receipt,Storage & Handling of Equipment & Matls IR 05000285/19880301988-09-21021 September 1988 Insp Rept 50-285/88-30 on 880829-0902.No Violations or Deviations Noted.Major Areas Inspected:Licensee Radiation Protection Program for External & Internal Radiation Exposure Control Programs & Surveys IR 05000285/19880271988-09-21021 September 1988 Insp Rept 50-285/88-27 on 880801-31.No Violations or Deviations Noted.Major Areas Inspected:Ler Followup, Operational Safety Verification,Plant tours,safety-related Sys Walkdown & Monthly Maint Observations ML20154L2961988-09-19019 September 1988 Insp Rept 50-285/88-25 on 880808-19.Violation Noted.Major Areas Inspected:Followup to Previous Insp Findings,Followup to Lers,Temporary Instructions & 10CFR Part 21 Repts IR 05000285/19880281988-09-16016 September 1988 Insp Rept 50-285/88-28 Om 880822-26.Violations Noted.Major Areas Inspected:Fire Protection/Prevention Program, Triennial post-fire Safe Shutdown Capability Reverification & Followup on Previously Identified Items IR 05000285/19880261988-09-14014 September 1988 Insp Rept 50-285/88-26 on 880725-29.No Violations Noted. Major Areas Inspected:Actions on Previous Insp Findings, Implementation of Inservice Testing Program for Valves & Pumps,Procedures,Results,Training,Witnessing & Maint IR 05000285/19880241988-09-0707 September 1988 Partially Withheld Insp Rept 50-285/88-24 on 880725-28 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Followup on Previously Identified Items,Lers,Review of Security Plan & Implementation Procedures & Compensatory Measures ML20207H7311988-08-19019 August 1988 Insp Rept 50-285/88-23 on 880701-31.Violations Noted.Major Areas Inspected:Previously Identified Items,Operational Safety Verification,Plant tours,safety-related Sys Walkdown & Monthly Maint,Surveillance & Security Observations ML20154K1311988-08-19019 August 1988 Insp Rept 50-285/88-200 on 880218,0321-25 & 0404-08. Violations Noted.Major Areas Inspected:Adequacy of Corrective Actions Initiated by Licensee in Response to 47 Design Findings Identified in Insp Rept 50-285/85-22 1990-09-25
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARPNO-IV-99-048, on 991026,Fort Calhoun Station Operators Reported Alert Because 4160 Volt Vital Buses 1A4 Were Deenergized for Approx 2 Minutes.Electrical Maint Personnel Have Inspected Electrical Equipment Inside & Outside Plant1999-10-26026 October 1999 PNO-IV-99-048:on 991026,Fort Calhoun Station Operators Reported Alert Because 4160 Volt Vital Buses 1A4 Were Deenergized for Approx 2 Minutes.Electrical Maint Personnel Have Inspected Electrical Equipment Inside & Outside Plant IR 05000285/19990101999-10-15015 October 1999 Insp Rept 50-285/99-10 on 990913-17.One NCV Noted.Major Areas Inspected:Mitigating Sys,Reactor Safety IR 05000285/19990091999-10-14014 October 1999 Insp Rept 50-285/99-09 on 990913-17.No Violations Noted. Major Areas Inspected:Effective Implementation of Protective Strategy When Required to Respond to Contingency Events ML20211P3441999-09-0707 September 1999 Insp Rept 50-298/99-08 on 990711-0821.No Violations Noted. Major Areas Inspected:Initiating Events,Mitigating Systems & Barrier Integrity IR 05000285/19990061999-09-0303 September 1999 Insp Rept 50-285/99-06 on 990809-12.No Violations Noted. Major Areas Inspected:Cornerstone Area of Reactor Safety, Emergency Preparedness.Insp Included Review of Licensee Program for Problem Identification & Resolution IR 05000285/19990071999-08-13013 August 1999 Insp Rept 50-285/99-07 on 990719-23.No Violations Noted. Major Areas Inspected:Accuracy & Operability of Radiation Monitoring Instrumentation Used for Protection of Occupational Workers IR 05000285/19990051999-07-19019 July 1999 Insp Rept 50-285/99-05 on 990601-0710.No Violations Noted. Major Areas Inspected:Broad Categories of Reactor Safety, Emergency Preparedness & Other Activities ML20195J2591999-06-11011 June 1999 Insp Rept 50-285/99-04 on 990425-0531.Noncited Violations Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000285/19990031999-05-18018 May 1999 Insp Rept 50-285/99-03 on 990314-0424.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support PNO-IV-99-025, on 990513,possible Stop Work in Response to Contract Dispute Occurred.Union Maint Personnel May Participate,But Operators & Security Personnel Will Not Participate.No Press Release Is Planned1999-05-14014 May 1999 PNO-IV-99-025:on 990513,possible Stop Work in Response to Contract Dispute Occurred.Union Maint Personnel May Participate,But Operators & Security Personnel Will Not Participate.No Press Release Is Planned IR 05000285/19990021999-04-0202 April 1999 Insp Rept 50-285/99-02 on 990131-0313.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19990011999-03-11011 March 1999 Insp Rept 50-285/99-01 on 990208-26.One Noncited Violation Was Identified.Major Areas Inspected:Evaluation of Cumulative Effect of Operator Workarounds at Plant Reactor Facility IR 05000285/19980191999-01-0808 January 1999 Insp Rept 50-285/98-19 on 981005-23 & 1211.Violations Noted. Major Areas Inspected:Corrective Action Program in Identifying Evaluation,Correcting & Preventing Problems That Affect Safe Operation of Facility ML20206R1601999-01-0808 January 1999 Notice of Violation from Insp on 981005-23 & 1211.Violations noted:licensee-established Measures Failed to Assure Prompt Identification & Effective Corrective Action to Address Potential for Core Reactivity Change IR 05000285/19980231999-01-0707 January 1999 Insp Rept 50-285/98-23 on 981108-1219.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000285/19980251998-12-30030 December 1998 Insp Rept 50-285/98-25 on 981130-1204.No Violations Noted. Major Areas Inspected:Licensee Emergency Preparedness Program IR 05000285/19980261998-12-17017 December 1998 Insp Rept 50-285/98-26 on 981131-1204.Deviations Noted. Major Areas Inspected:Plant Support Activities ML20198J2051998-12-17017 December 1998 Notice of Deviation from Insp on 981131-1204.Deviation Noted:Licensee Quality Assurance Dept Conducted Biennial Audits of All Transfer,Packaging & Transport Activities Involving Radioactive Matl IR 05000285/19980131998-12-16016 December 1998 Insp Rept 50-285/98-13 on 981130-1204.No Violations Noted. Major Areas Inspected:Review Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program IR 05000285/19980241998-11-20020 November 1998 Insp Rept 50-285/98-24 on 981102-06.Violations Noted.Major Areas Inspected:Plant Support ML20195H8021998-11-20020 November 1998 Notice of Violation from Insp on 981102-06.Violation Noted: from 4:45 to 11:45 Am on 980423,room 13 on Elevation 989 Ft of Auxiliary Building Not Posted as Airborne Radioactivity Area When Sample Results Showed Excess Radioactivity IR 05000285/19980211998-11-13013 November 1998 Insp Rept 50-285/98-21 on 980927-1107.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980171998-10-28028 October 1998 Insp Rept 50-285/98-17 on 980928-1002.No Violations Noted. Major Areas Inspected:Licensee Operator Requalification Program to Determine Whether Program Incorporated Appropriate Requirements IR 05000285/19980181998-10-0808 October 1998 Insp Rept 50-285/98-18 on 980831-0902.No Violations Noted. Major Areas Inspected:Changes to Fort Calhoun Station Radiological Emergency Action Levels IR 05000285/19980201998-10-0505 October 1998 Insp Rept 50-285/98-20 on 980816-0926.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980221998-09-29029 September 1998 Insp Rept 50-285/98-22 on 980914-18.No Violations Noted. Major Areas Inspected:Routine,Announced Insp Reviewed Implementation of Radiological Environ & Meteorological Monitoring Programs IR 05000285/19980141998-08-28028 August 1998 Insp Rept 50-285/98-14 on 980705-0815.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000285/19980121998-08-17017 August 1998 Insp Rept 50-285/98-12 on 980601-05 (on Site) & 980811 (in Ofc).One Noncited Violation Noted.Major Areas Inspected: Operations,Maint & Engineering.Root Cause Assessment, Performed as Result of 980527 Pump FW-10 Occurrence IR 05000285/19980151998-08-0606 August 1998 Insp Rept 50-285/98-15 on 980727-31.No Violations Noted. Major Areas Inspected:Testing & Maint,Protected Area Barrier & Detection Aids,Vital Area Barriers & Detection Aids, Security Event Logs & Security Training & Qualifications IR 05000285/19980161998-07-29029 July 1998 Insp Rept 50-285/98-16 on 980706-10.Violations Noted.Major Areas Inpected:Solid Radwaste Mgt & Radioactive Matls Transportations,Associated Training Activities & QA Oversight ML20236W2931998-07-29029 July 1998 Notice of Violation from Insp on 980606-10.Violation Noted: Licensee Did Not Take Dry Active Samples Annually.Dry Active Waste Stream Samples Were Collected in June 1995 & Aug 1997 IR 05000285/19980101998-07-21021 July 1998 Insp Rept 50-285/98-10 on 970524-0704.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236M7531998-07-0808 July 1998 Notice of Violation from Insp on 980521-0605.Violation Noted:On 980520,licensee Personnel Did Not Write Maint Work Document to Document Deficiency W/Valve FP-230 Following Manipulation of Valve ML20236M7581998-07-0808 July 1998 Insp Rept 50-285/98-11 on 980521-0605.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000285/19980091998-06-25025 June 1998 Errata to Insp Rept 50-285/98-09.Correction Due to Errrors on Pages 5 & 13 ML20249A6181998-06-15015 June 1998 Insp Rept 50-285/98-09 on 980412-0523.Violations Noted:Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20249A6171998-06-15015 June 1998 Notice of Violation from Insp on 980412-0523.Violation Noted:On 980402,licensee Did Not Have Adequate Procedure for Performing Activity That Affected Quality PNO-IV-98-021A, on 980526,update to Loss of Offsite Power Made.Components Have Been Replaced & Sys Functioning Properly.Correction Should Be Made to Info in Original Pn. Nonvital Buses 1A1 & 1A2 Continuously Energized1998-05-26026 May 1998 PNO-IV-98-021A:on 980526,update to Loss of Offsite Power Made.Components Have Been Replaced & Sys Functioning Properly.Correction Should Be Made to Info in Original Pn. Nonvital Buses 1A1 & 1A2 Continuously Energized ML20249C1431998-05-24024 May 1998 Notice of Violation from Insp on 980415-24.Violation Noted: Inspectors Identified That Licensee Had Not Submitted in 1984 & 1994 Relief Requests for Code Class Welds That Did Not Receive Full Exam Coverage During 10-yr ISI Intervals IR 05000285/19980071998-05-24024 May 1998 Insp Rept 50-285/98-07 on 980415-24.Violations Noted.Major Areas Inspected:Operations & Maint PNO-IV-98-021, on 980520,loss of Offsite Power Occurred as Result of Fault on Transformer T1A-3,161 Kv to 4 Kv Transformer Which Supplies Power to One of Two Vital Electrical Buses.Special Followup Initiated on 9805211998-05-21021 May 1998 PNO-IV-98-021:on 980520,loss of Offsite Power Occurred as Result of Fault on Transformer T1A-3,161 Kv to 4 Kv Transformer Which Supplies Power to One of Two Vital Electrical Buses.Special Followup Initiated on 980521 ML20217N0991998-04-30030 April 1998 Insp Rept 50-285/98-06 on 980406-10.Violations Noted.Major Areas Inspected:Plant Support ML20217N0931998-04-30030 April 1998 Notice of Violation from Insp on 980406-10.Violation Noted: on 980407,individual Working in Accordance W/Radiation Work Permit 98-0011 Entered Restricted High Radiation Area in Steam Generator Bay B W/O Radiation Protection Coverage IR 05000285/19980051998-04-22022 April 1998 Insp Rept 50-285/98-05 on 980301-0411.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20217E0061998-04-22022 April 1998 Notice of Violation from Insp on 980301-0411.Violation Noted:Inspectors Identified That Licensee Did Not Have Procedure for Performing an Activity That Affected Quality ML20217Q9251998-04-0606 April 1998 Insp Rept 50-285/98-01 on 980120-23 & 26-0306.No Violations Noted.Major Areas Inspected:Plant Support,Including Fire Protection Program IR 05000285/19980031998-03-27027 March 1998 Insp Rept 50-285/98-03 on 980223-27 & 0311-18.No Violations Identified.Major Areas Inspected:Licensee Physical Security Program,Access Authorization,Alarm Stations,Communications, Access Control of Event Logs & Mgt Support ML20217D4471998-03-25025 March 1998 Notice of Violation from Insp on 980209-13 W/In Ofc Insp Until 980302.Violation Noted:Since Aug 1994 QA Lead Auditor Had Not Satisfied or Completed QA Qualification Manual Requirements Prior to Conducting Lead Auditor Functions IR 05000285/19980021998-03-25025 March 1998 Insp Rept 50-285/98-02 on 980209-13 W/In Ofc Insp Until 980302.Violations Noted.Major Areas Inspected:Operations & Engineering IR 05000285/19980041998-03-12012 March 1998 Insp Rept 50-285/98-04 on 980118-0228.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-09-07
[Table view] |
Text
.
.,
. . .
A
'
l
-
UNITED STATES
'
NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION Report No.: 50-285/87-22 Docket No.: 50-285 License No.: DPR-40
.
Licensee: Omaha Public Power District Facility: Fort Calhoun Station, Fort Calhoun, Nebraska Inspection At: Fort Calhoun Station
-
Dates: August 17-21, 1987 Inspectors: UN2 [M Edward T. Baker', Team reader, Program Development and Dats
ReactiveInspectionSection(PDRIS)
$ $4 U 7 Peter J. Prescott, FDR15 C Date Approved By: kLr I Edward T. Baker, Acting Chief, PDRIS, Vendor k/'/P'2 Dats
. Inspection Branch Inspection Summary: Inspection on August 17-21, 198 Areas Inspected: This special announced inspection was conducted at Fort Calhoun Station to determine to what extent the ASME Boiler and Pressure Yessel Code, Section XT, and 10 CFR 50, Appendix J. valve testing programs verified check valve disk and seat integrity. The inspectors also reviewed the licensee's response to INP0's SOER 86-03, concerning check valves. The areas inspected included maintenance and testing records, inspection and testing procedures, valve location with respect to flow disturbances (e.g., elbows and pump discharges),andsystemdrawing Results: The inspectors found that (1) a maintenance procedure for post maintenance testing did not cover the appropriate valves; (2) a maintenance order was written to investigate a noise in check valve AC-104 and cancelled because no parts were available to perform the maintenance; no evidence existed that maintenance was performed after the maintenance order was cancelled; and (3) check valves are not being tested to ensure that all safety functions, pressure isolation as well as passing flow, are being adequately tested. The Ft. Calhoun program does not appear to aggressively address the issue of ensuring that check valves are functional. This was reflected in the Ft. Calhoun response to SOER 86-03. In addition, a number of check valves were noted to be located immediately downstream of pumps or other turbulence i generators. It was also noted that the vast majority of the maintenance performed was corrective, as opposed to preventive maintenanc gDR ADOCK O g5
-
. .
..
. .
.
DETAILS PERSONS CONTACTED C. Bloyd, Technical Services J. Fisicaro, Licensing J. Friedricksen, Technical Services D. Golden P. Harrell, NRC Senior Resident '
D. Hendry, OPPD R. Kellog, Supervitor, Mechanical Technical Services M. Klonderud, OPPD L. Kusek, OPPD K. Miller, OPPD R. Mueller, OPPD Plant Engineering D. Munderloh, OPPD Licensing The inspectors also held discussions with other licensee employees during the inspectio Everyone listed above was present at the exit meeting on August 21, 1987. SCOPE The licensee's programs for testing, inspecting, and maintaining check valves were reviewed to determine the adequacy of the programs to ensure disk and seat integrity. The licensee's response to INP0's SOER 86-03, concerning check valves, was also reviewe . LICENSEE ACTION ON PREVI0llSLY IDENTIFIED PROBLEMS Problems that had been identified previously were not addressed during the inspectio . REVIEW 0F CHECK VALVES
,
4.1 Component Cooling Check valves AC-101, AC-104, and AC-107 are the component cooling pump discharge check valves. All three valves are located downstream of a 90 elbow that is attached to the pump discharge and upstream of an isolation valve and a 90 elbow. The valves are tested for passing flow only under the pump test procedure ST-ISI-CC3. The acceptance criterion for opening is that pump discharge pressu,re is less than 120 psig. The pump test curve has a 2000-gpm acceptance ban The valves are not tested for closure, although such testing would appear to be required by Section XI for valves that are both open and closed during normal plant operations (0 pen Item 50-285/87-22-03).
The review of maintenance orders (M0s) indicated that all three valves had required corrective maintenance. MO 10899 was written on July 15, 1981 because check valve AC-101 failed to close and the pump ran in revers l l - -
-
. .
..
~
. .
.
Inspection revealed that the flapper arm was bent. M0 830044 was written on November 3, 1983 because check valve AC-104 was making nois However, the M0 l was cancelled because there were no parts available to perform maintenance, j No work has been done on the valve since MO 830044 was cancelled (0 pen Item 50-285/87-22-02). M0s 851981 and 855175 were written in June 1985 because-check valve AC-107 was making noise. After taking the valve apart and l inspecting it, no damage was foun '
4.2 Raw Water Raw water (RW) check valves RW-115, RW-117, RW-121, and RW-125 are the discharge check valves for the raw water pumps. The valves are located downstream of 90 elbows that are attached to the pump discharges and upstream of isolation valves that are attached to tees. The pumps are tested for forward flow under procedure ST-ISI-RW-3 with an acceptance criterion of pump total dynamic head of 140 psig or less indicating the valves are open. The valves are not tested for closure although such testing would appear to be required by Section XI for valves that are both open and closed during normal plant operations (0 pen Item 50-285/87-22-03). No maintenance involving seat, disk or operability was noted during the period reviewe .3 Containment Sump Suction Check valves SI-159 and SI-160 are located in the containment sump and prevent the reactor water storage tank from draining into the sump. One of these valves is removed and inspected on an alternating basis every five year These valves are located directly downstream of 90' elbows. The inspection of SI-159 on February 14, 1985 recorded the valve's condition as "like new." No
. Other maintenance involving seat, disk or operability was noted during the period reviewe .4 Safety Injection (1) Containment Spray Valves Valves SI-135, SI-143, and SI-149 are the containment spray pump discharge check valves and prevent reverse flow through the idle pumps. The valves are tested for forward flow only, not for closure (0 pen Item 50-285/87-22-03). No maintenance activities involving the seat, disk, or operability were noted
-
during the period reviewe Check valve SI-135 is located 3 feet downstream from the pump discharge and immediately upstream of a 90" elbow. Check valves SI-143 and SI-149 are <
located 3 feet downstream of the pump discharges and immediately upstream of 90 and 60* elbow (2) Low-Pressure, Safety Injection Pump Discharge Valves Valves SI-121 and SI-129 are the low pressure, safety-injection (LPSI) pump discharge check valves. The valves are tested for forward flow only; there is no testing for closure (0 pen Item 50-285/87-22-03). Both valves are located 3 feet downstream from the pump discharge and immediately upstream of ! solation valves. For the period reviewed, no maintenance was noted involving the seat, disk, or operabilit _ _ _ - _ _ _
I
< '
.
.. .-
,
. .
'
.
(3) High-Pressure Safety-Injection Pump Discharge Valves Valves SI-102, SI-108, and SI-115 are the high-pressure, safety-injection (HPSI) pump discharge check valves. The valves are tested for forward flow only; there is no testing for closure (0 pen Item 50-285/87-22-03). The valves are located 2 feet downstream of 90 elbows that are attached to the pump discharges and intnediately upstream of tees that are followed 3 feet q For the period reviewed, no maintenance was noted
'
downstream by 90' elbow involving the seat, disk, or operabilit (4) High-Pressure, Safety-Injection Secondary Isolation Valves !
Valves SI-195, SI-198, SI-201, and SI-204 are the HPSI secondary isolation check i valves. The valves are tested for forward flow during refueling outages and 2 are tested for leaks under Surveillance Test ST-CV-1 during refueling outage These valves were not inspected for location and for the period reviewed, no j maintenance involving the seat, disk, or operability was note (5) Low-Pressure, Safety-Injection Secondary Isolation Valves Valves SI-194, SI-197, SI-200 and SI-203 are the LPSI secondary isolation check valves. These are tested for leaks under Surveillance Test ST-CV-2 and '
are tested for forward flow during refueling outages. These valves were not inspected for location and for the period reviewed, no maintenance involving the seat, disk, or operability was note (6) Primary Isolation Valves Valves SI-208, SI-212, SI-216 and SI-220 are the primary pressure isolation check valves between the reactor coolant piping and the lower pressure safety-injection systems. The valves are tested for forward flow and for leak Th se valves were not inspected for location and for the period reviewed, no I maintenance involving the seat, disk, or operability was note i l
4.5 Main Steam (1) Main Steam Isolation Check Valves Valves HCV-1041A and HCV-1042A are the power-operated main steam isolation check valves installed in the 24-inch main steam line. These valves close on
a two-out-of four logic, steam generator isolation signal (SGIS) so that the steam generators can be isolated automatically to prevent their blowdown in the event of a main steam line break (MSLB) inside containment. The licensee a stated that the leak rates of the valves are determined during refueling outages and after certain types of maintenance are performed on the valves per the inservice inspection procedure No. ST-151-MS-1. In reviewing the main-tenance procedure, MP-MSIV-1, the inspector noted the post-maintenance test procedure referenced is ST-ISI-MS-1. However, ST-ISI-MS-1 does not provide instructions for testing these valves (0 pen Item 50-285/87-22-01). The NRC inspector reviewed several M0s related to the subject valves dated between March 3, 1984 and June 23, 1987; the inspector was able to verify some documen-tation of leak rate testing for the subject valves. The valves also are tested for forward flow during normal operatio A review of the M0s revealed
_ _ _ - _ _ _ _ _ _ _
I
. .. .-
. . ,
.
that the subject valves did receive substantially more maintenance than the check valves reviewed in other systems. The increased maintenance was mainly attributed to high steam flow through the valves and packing leak l These valves are located immediately upstream of check valves HCV-1041B and .
'
HCV-10428, respectively, and immediately downstream of the main steam safety relief valves, that are immediately downstream of a 90' elbo ;
(2) Main Steam Lirie Check Valves Valves HCV-1041B and HCV-10428 are the main steam line check valves. The licensee stated that these valves are tested for forward flow during normal operations. The subject check valves are not tested for leak rate because of
.
an assumption made in the Updated Safety Analysis Report (USAR), Section 14.1 (Method of Analysis) that a single failure of the reverse-flow check valve in the ruptured steam generator is assumed, so that the intact steam generator will have ; team flow through the unaffected steam line and back through and out the ruptured line. The analysis conservatively neglects a choke that is installed in each steam line and assumes the steam will flow from the intact steam generator through an unrestricted 24-inch steam line. The NRC inspector reviewed several maintenance orders dated from March 3, 1984 through July 15, 1986 which documented a number of inservice inspections of the internal components of the valves; however, the maintenance required on the valves was minimal. These valves are immediately downstream of 90 elbows, main steam safety relief valves, and the main steam isolation valves HCV-1041A and HCV-1042A, j respectivel .6 Chemical and Volume Control System Check valves CH-203, CH-204 and CH-205 are located in the charging line, alternative charging line, and common supply line, respectively, between the chirging pumps and reactor coolant piping. Aside from observing unrestricted flow during plant operations, these valves are not included in any test procedure, nor is their proper operation recorded anywhere. The licensee stated that the valves are not tested because they are always experiencing full flow, do not perform an isolation function, and are consistently in the full-open position; therefore, the subject valves are not required to be exercised under the Section XI in-service testing (IST) requirements for check valves in the normally open positio However, the check valve on either the normal or alternate charging ifne should close when the other line is performing the charging function and does isolate the reactor coolant system in the event of a break in either line (0 pen Item 50-285/87-22-03).
These valves were not inspected for locatio Check valve CH-198 is located in a 2-inch line downstream of the three positive displacement charging pumps. The valve is also located just outside the containment, I foot downstream from a 90* elbow and functions to prevent backflow to the charging pump discharge header (an isolation function).
Because the check valve does perform an isolation function, it is required to be exercised under the Section XI IST requirements for valves performing an isolation function. However, ir the IST program submitted for review by the
__
- - . ._ -
. .
.~
.
.
.
licensee, an exemption is requested for check valve CH-19 The exemption j states in part, that back seat testing on reversal of flow or stroke testing of the valve cannot be performed because of piping configuration However, forward flow shall be tested at each refueling outag Check valves CH-187, CH-188, and CH-189 are located in 2-inch lines directly off the positive displacement charging pumps. The check valves are tested for passing flow through the valves during normal operation. The licensee also stated that operating procedures require the charging pumps to be tested in rotation once a week, at which time the check valves are tested to ensure that they close on backflow conditions. However, the procedures and records of test results were not formally documented (0 pen Item 50-285/87-22-03).
A review of maintenance records indicated that no maintenance relevant to disk or seat integrity had been performed on the chemical and volume control system (CVCS) check valves that were reviewe .7 Feedwater System Feedwater (FW) system check valves FW-106, FW-107, and FW-108 are located in 14-inch lines downstream of 90 elbows that are attached to the motor-driven steam generator feed pumps and upstream of an isolation valve that has a 90*
elbow attached on the downstream side. The valves are lift-type check valves and are tested for passing flow during normal operation. The licensee also stated that operating procedures require rotational testing of the feed pumps once a month, at which time the check valves are tested to ensure they close under backflow conditions. However, the procedures for and records of testing were not formally documented (0 pen Item 50-285/87-22-03).
Check valves FW-161 and FW-162 are installed in the two 16-inch main feedwaf.er lines and are located directly upstream of the steam generators. These valves are normally open during operation; to cycle these valves closed would result in a loss of normal feedwater to the steam generator. Then the water level in the steam generator could drop, possibly causing a reactor trip. However, in the IST program that the licensee submitted for NRC review, an exemption is requested for the backflow testing of check valves FW-161 and FW-162. The exemption states,<in part, that since the failure of these valves to function in the backflow direction would not interfere with the plant's ability to shut
. down or mitigate the consequences of an accident, these valves shall only be tested in the forward-flow direction. The exemption further stated that the valves shall be exercised at each cold shutdown or refueling outage, or if more than one cold shutdown or refueling occurs during a 3-month period of time, the valves shall only be exercised once during that 3-month perio These valves were not inspected for locatio Check valves FW-163 and FW-164 are installed in the two 3-inch auxiliary feedwater (AFW) lines located directly upstream of the steam generators. These valves open for AFW flow to the steam generator. Cycling these valves during operation would inject cold water into a portion of the steam generato However, in the IST program that the licensee submitted for NRC review, an exemption is requested for the backflow testing of check valves FW-163 and 164. The exemption states, in part, that since the failure of these valves to function in the backflow direction would not interfere with the plant's
- _ _ _ - _ -
.
. _ _.
. .. .
.
. .
= ,
ability to shut down or mitigate the consequences of an accident, these valves shall only be tested in the forward-flow direction. The exemption further stated, that the valves shall be exercised at each cold shutdown or refueling outage, or if more than one cold shutdown or refueling occurs during a 3-month period of time, the valves shall be exercised once during that 3-month perio These valves were not inspected for locatio Check valve FW-173 is installed in a 4-inch line located directly off the motor-driven AFW pump. The valve is onl exceeding a reactor coolant system loop (RCS)y tested for temperature forward 6f 300'F, per flow before operating procedure OP- The licensee stated that the valve initially was thought to have received a quarterly test for forward flow per surveillance test procedure No. ST-FW-1-1 in which the flow was directed to the emergency feedwater storage tank (EFST). However, it was discovered that when the flow is directed to the EFST, the flow no longer passes through check valve FW-173; therefore, the licensee has requested an exemption for the subject valve in its-latest IST program submitta The valve is located immediately downstream of a 90' elbow and immediately upstream of a tee, 90* elbow, and an isolation valv Check valve FW-1334 is installed in a 4-inch line that provides AFid to the steam generators via the normal feedwater flowpath. On May 23, 1987, the licensee issued a maintenance order to check the leakage rate through the check valve. The valve was determined to be functional. The licensee stated that the test was performed as part of its response to INPO SOER 86-03 which identified some operational problems with check valves supplied by the manu-facturer, Pacific Valves. The licensee further stated that it does not consider check valve FW-1334 to be a critical valve in the AFW system and that the valve is normally tested only for passing flow before exceeding an RCS loop temperature of 300' A review of maintenance records indicated that no maintenance relevant to disk or seat integrity had b o n performed on the feedwater valves that were reviewe .8 Auxiliary Feedwater Pump Check Valves Check valves MS-351 and MS-352 are installed in the 2-inch steam supply lines to the steam-driven AFW pum If these valves failed to perform their backseat function in the event of a steam line break (in the supply line), no steam would be supplied to the AFW pump. The licensee stated that the valves are not tested for backflow conditions, only for passing flow (0 pen Item 50-285/
87-22-03). A review of the M0s did reveal some inservice inspection of the internal components of the valves and a minimum of required maintenanc I Check valve MS-351 was located 3 feet downstream of two 90* elbows and 2 feet upstream of a tee. Check valve MS-352 was located 2 feet upstream of a te .9 Diesel Generator Air Start System Check Valves Check valves SA-137, SA-138, and SA-188 are installed in 3/4-inch lines located directly downstream of the emergency diesel generator (EDG) starting air compressors. The valves' function is to keep air from leakirig from the
_ - _ _
'
. .. .
'
.
.
four EDG air start receivers. The licensee stated that the valves are only tested for forward air flow through the valves during normal operation and ,
that the air piping and compressors upstream of the valves are seismically ]
qualified. A review of the maintenance records indicated that no maintenance of interest had been performed during the time period reviewed. Valves SA-137 and SA-138 are installed between two 90' elbow i' SOER Resp 0NSE At the time of the inspection, the licensee's response to the SOER consisted of a four-page internal memorandum dated December 16, 1986. restating the 50ER guidelines and outlining planned actions. The licensee had started, but had not completed, a review of valve location, valve maintenance history, and valve size. The licensee plans to complete this review by February 1988 and to determine by that date which valves should be included in a preventive maintenance (PM) program. The licensee did not intend to start developing the PM program until meeting the February 1988 commitmen . EXIT MEETING The inspectors met with the licensee's representatives listed in Section 1 on August 20, 1987, and presented the findings of this inspectio .
))
l