Text
- - -
.,
.-
.
p 3l y
-
Docket Nos. 50-313/90-37
50-368/90-37
License Nos. DPR-51
NFF-6
Entergy Operations, Inc.
ATTN:
Neil S. Carns, Vice President
Operations, Arkansas Nuclear One
Route 3, Box 137G
Russellville, Arkansas 72801
Gentlemen:
This refers to the inspection conducted by Messrs. A. Singh and D. L. Kelley of
this office during the period October 15-19, 1990, of activities authorized by
NRC Operating Licenses DPR-51 and NPF-6 for Arkansas Nuclear One, Units 1 and
2, and to the discussion of our findings with Mr. J. D. Vandergrift and other
members of your staff at the conclusion of the inspection.
The area examined during the inspection was the verification of containment
integrity. Within this area, the inspection consisted of selective examination
of procedures and representative records, interviews with personnel, and a
100 percent visual inspection of the accessible containment building penetrations
and their associated isolating components. The inspection findings are documented
in the enclosed inspection report.
Within the scope of the inspection, no violations or deviations were identified.
We have also examined actions you have taken in regard to a previously identified
unresolved item. The status of this item is identified in paragraph 2 of the
enclosed report. As a f ollowup to a tr.lephone conversation on October 20,
1990, between this office and Mr. James Fisicato and members of his staff, it
is our understanding that additional information will be provided to this
office regarding the unresolved item within 30 days from October 26, 1990,
please advise us promptly if this is not your understanding.
This report does not incude specific inspection followup for any Diagnostic
Evaluation Team findings (reference Diagnostic Evaluation Team Report issued
December 21,1989).
Should you have any questions concerning this inspection, we will be pleased to
- discuss them with you.
'[b
p-
iue
J. Collins, Director
ivision of Reactor Projects
Enclosure:
(seenextpage)
- RIV:TPS
- RI:TPS
- C:TPS
(ADRS
0:DRP
ASingh/lb
DLKelley
WCSeidle
f LJCallan
SJCollins
t
g/(/90
, gj
(p/g/90
/ /90
/ /90
/ /90
5
$
- Previously concurred
j
- 8A"R88M 88688!m
/ g'
o
PNV
.
.
..
~'
'
.
.
.
,
.
Entergy Operations, Inc.
-2-
'
Enclosure:
Appendix - NRC Inspection Report
50-313/90-37 w/Attachraent
50-368/90-37 w/ Attachment
cC:
Entergy Operations, Inc.
ATTN: Donald C. Hintz, Executive Vice
President & Chief Operating Officer
P.O. Box 31995
Jackson, Mississippi 39286
Entergy Operations, Inc.
ATTN: Gerald W. Muench, Vice President
Operations Support
-
P.O. Box 31995
Jackson, Mississippi 39286
Wise, Carter, Child & Caraway
ATTN:
Robert B. McGehee, Esq.
P.O. Box 651
Jackson, Mississippi 39205
Arkansas Nuclear One
ATTH:
Early Ewing, General Manager
- Technical Support and Assessnent
Route 3, Box 1370
Russellville, Arkansas 72801
Arkansas Nuclear One.
ATTN: Jerry Yelverton, Director
. Nuclear Operations
Route 3 Box 137G
Russellville, Arkansas 72801
Arkansas Nuclear One
ATTN: Mr. Tom W. Nickels
Route 3, Box 137G
Russellville, Arkansas 72801
Combustion Engineering, Inc.
ATTN: Charles B. Brinkman, Manager
L
Washington Nuclear Operations
12300 Twinbrook Parkway, Suite 330
Rockville, Maryland 20852
Honorable Joe W. phillips
.
County Judge of Pope County
l
Pope County Courthouse
l
Russellville, Arkansas 72801
. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . . .
.
.
e
Entergy Operations, Inc.
-3-
Winston & Strawn
ATTN: Nicholas S. Reynolds. Esq.
1400 L Street, N.W.
Washington, D.C.
20005-3502
Arkansas Departnent of Health
ATIN: Ms. Greta Dieus, Director
Division of Environmental Health
!
Protection
4815 West Markam Street
Little Rock, Arkansas 72201
Babcock & Wilcox
Nuclear Power Generation Division
ATTN: Mr. Robert B. Borsum
1700 Rockville Pike, Suite 525
Rockville, Maryland 20852
Admiral Kinnaird R. McKee, USN (Ret)
P.O. Box 41
0xford, Maryland 21654
bectoDMB(IE01)
bec distrib, by RIV:
- R. D. Martin
- Resident inspector
- DRSS-FRPS
- SectionChief(DRP/A)
Lisa Shea, RM/ALF
- RIV File
- DPP- .
- MIS System
- RSTS Operator
- Project Engineer (DRP/A)
- DRS
- D. L. Kelley
- A. Singh
- W. C. Seidle
- T. Alexion, NRR Project Manager (MS: 13-E-21))
- C, Poslusny, NRR Project fianager (MS: 13-D-18
- w/766