. _ __ . . . __ . _ __

".3 .-

October 16, 1990 l Docket Hos. 50-313  :

and 50 368 Mr. Neil S. Care:.

l Vice President, Operations ANO l Entergy Ope:ations, Inc. ,

l Route 3 Psx 137G Russellville, Arkansas 72801 l

Dear Mr. Carns:

SUBJECT:

AUTHORIZATION FOR USE OF INCONEL 690 (I-690) AS AN ALTERNATIVE TO I-600 IN STEAM GENERATOR TUBE SLEEVES AND PLUGS IN ACCORDANCE WITH- '

10CRF50.55a(a)(3)(TACNOS.77520AND.77591) ,

-By letter dated August 27, 1990, Entergy Operations requested to use sleeves and plugs-fabricated of the I-690 material as an alternative to I-600 for

The I-690 material has mechanical properties similar to'I-600 and has superior 4 corrosion resistance properties. The NRC staff endorsed the use of I-690 forL fabrication of mechanical plugs for-steam generator tubes in NRC -Ilet h No.

89 01, " Failure of Westinghouse Steam Generator Tube Mechanical P "

,;tay 15, i 1989. Based on the above, I-690=is acceptable as_an alternative w 1 60J.

l l We have reviewed your request and supporting information'and conclude.thit the l use of I-690 in accordance with ASME Code Case N-474 1 and in the' requisite product forms (such as tubing and bar stock), as a proposed alternative to the-use of I-600, will provide an acceptable level of quality and safety. Therefore, based on the above, 1 690 in the requisite product-forms is acceptable as an alternativetotheuseof1-600,and.itsuseforsleevingandplugging)tubesin steamgeneratorsisauthorizedundertheprovisionsof10-CFR50.55a(a(3).

Sincerely, I w mb 7 eodore R. Quay, Project Director  !

Project Directorate.IV-1

, Division of Reactor Projects - III, <

l 'IV, Y and Special Projects

_, - r<

,J , o Office of Nuclear' Reactor Regulation. ,

cc: See next page n

DISTRIBUTION tD5EEEEFTTIM T. Alexion -T. Quay ~ ACRS(10)MS.P-315 ), i C. Poslusny L. Berry @fh NRC PDR- PD4-1 Plant File; Local POR OGC 15B18 C. Cheng 7D4

8. Boger 13E4

~dQ PD4-1 Reading E. Jordan HNBB 3701- \ ,

OFC :PD4-1/LA- :PD4-1/PM :PD4-1/Py

. g :EMGB/BCACr :0GC :PD4-1/D q

. . . . . . : . . .Lt . . . . . . . . . . : . . . . . .2 NAME :t.$ry :TAlex

-:..... .. 4 4. . . . . . . . . . . . . : . . . . . . . . .# . . . :TQuay

CPoslusT d :C. Chen

. . . . .g. 4. . . - 1

. i

.... 4L.--- & -- U ...:......-- f,.:: g:, Su.Ic n :

DATE :09/?l/90 :09/ I /90 59/@/90 :09/f//901 .:0h--..........:g............

/90; r:69/P/90 nFFICIAl RFCnRD CM Y Document' Name: ' INCONEL 690 TAC 77520: ,

9010250034 901016 D si ADOCK 05000313

^

PDR P ._ _

PDC _

+

, _. - - ~. _ - . . - - - _ _ _ - _ - - - . _ _ _ _ _ _ _ _ - _ _ - _ _ _ _ _ _ _ _ _ _

  1. ' ?g,patog

. UNITED STATES E h .y ig * 'k p, NUCLEAR REGULATORY COMMISSION. >

y j

, 5i wAssiNoToN, o. c. 20sss

. . ' , .* October 16, 1990 Docket Nos. 50-313 and 50-368 Mr. Neil S. Carns Vice President, Operations ANO

Entergy Operations, Inc.
  • Route 3 Box 137G Russellville, Arkansas 72801

Dear Mr. Carns:

SUBJECT:

AUTHORIZATIONFORUSEOFINCONEL690(I-690)ASANALTERNATIVETO I-600 IN STEAM GENERATOR TUBE SLEEVES AND PLUGS IN ACCORDANCE WITH 10 CRF 50.55a(a)(3) (TAC NOS. 77520 AND 77591)

By letter dated August 27. 1990,-Entergy Operations requested to use sleeves -

and plugs fabricated of the I-690 material as an alternative to I-600 for repairs of the steam generators at Arkansas Nuclear One,. Units 1 and 2 (AN0; 1&2).

! The 1-690 material has mechanical properties similar to I-600 and has superior corrosion resistance properties. The NRC staff endorsed.the use of I-690 for fabrication of mechanical plugs-for steam generator tubes in NRC Bulletin No.

89-01, " Failure of Westinghouse Steam Generator-Tube Mechanical Plugs", May 15, 1989. Based-on the above, I-690 is acceptable as an alternative to I-600.

f We have reviewed your request and supporting information 'and conclude that the use of 1-690 in accordance with ASME Code Case N-474-1 and in the requisite productforms(suchastubingandbarstock),as'a-proposedalternativetothe-use of I-600, will provide an acceptable level of quality and safety. Therefore, based on the above, I-690 in the requisite product forms is acceptable as an

, alternative steam generators to theis use of I-600, authorized under and theits use for sleeving provisions of 10 CFRand plugging) 50.55a(a (3). tubes in

. Sincerely,.

i hk .

g

. Theodore R. Quay, Project Director i Project' Directorate'IV ! cc: See next page Division of Reactor. Projects _III,

'IV, V and Special Projects  ;

Office of Nucle;r Reactor Regulation 4 l

)

,- - + , - _m -.~ - - - -. _ . _ _ _ -

, . - .. . 1

. Entergy Operations, Inc. Arkansas Nuclear One, Units 1 & 2 cC: '

Mr. Early Ewing, General Manager Mr. Donald C. Hintz Technical Support and Assessment Executive Vice President ,

Arkansas Nuclear One and Chief Operating Officer ,

Route 3 Box 137G Entergy Operations, Inc.

Russellville, Arkansas 72801 P. O. Box 31995 Jackson, Mississippi 39286 Mr. Jerry Yelverton Mr. Gerald Muench Director Nuclear Operations Vice President Operations Support Arkansas Nuclear One Entergy Operations, Inc.

Route 3 Box 137G P. O. Box 31995 Russellville, Arkansas 72801 Jackson, Mississippi 39286 Mr. Nicholas S. Reynolds Mr. Robert B. McGehee, Esquire Bishop, Cook, Purcell & Reynolds Wise, Carter, Child & Caraway 1400 L Street, N.W. P. O. Box 651 Washington, D.C. 20005-3502 Jackson, Mississippi 39205 Mr. Robert B. Borsum Mr. Charles B. Brinkman, Manager Babcock & Wilcox Washington-Nuclear Operations Nuclear Power Generation Division Combustion Engineering, Inc.

1700 Rockville Pike, Suite 525 12300 Twinbrook Parkway, Suite 330 Rockville, Maryland 20852 Rockville, Maryland 20852 Senior Resident Inspector Mr. Tom W. Nickels U.S. Nuclear Regulatory Commission Arkansas Nuclear One 1 Nuclear Plant Road Route 3 Box 137G Russellville, Arkansas 72801 Russellville, Arkansas 72801 i Regional Administrator, Region IV Admiral Kinnaird R. McKee, USN (Ret)

! U.S. Nuclear Regulatory Commission Post Office Box 41 Office of Executive Director Oxford, Maryland 21654 for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 ,

Honorable Joe W. Phillips l County Judge of Pope County Pope County Courthouse i Russellville, Arkansas 72801 Ms. Greta Dieus, Director Division of Environmental Health Protection Arkansas Department of Health 4815 West Markam Street Little Rock, Arkansas 72201 r

(

_ _ . _ _ . .__ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _