ML061420086
| ML061420086 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek (DPR-016) |
| Issue date: | 04/18/2006 |
| From: | Nash H Office of Nuclear Reactor Regulation |
| To: | Masnik M Office of Nuclear Reactor Regulation |
| References | |
| %dam200606, TAC MC7624 | |
| Download: ML061420086 (10) | |
Text
Michael Masnik - Fwd: Oyster Creel Non-routine Environmental Operating Report Page 1 l From:
To:
Date:
Subject:
Harriet Nash mtm2 4/18/06 10:36AM Fwd: Oyster Creel Non-routine Environmental Operating Report
- Mike, Attached is the "complete shutdown" report.
I C:\\WINDOWS\\TEMP\\GW)00001.TMP Page 1 Mail Envelope Properties (4444F98A.A26: 20: 34894)
Subject:
Creation Date:
From:
Created By:
Fwd: Oyster Creel Non-routine Environmental Operating Report 4/18/06 10:36AM Harriet Nash HLN@nrc.gov Recipients nrc.gov TWGWPOOI.HQGWDOO1 MTM2 (mtm2)
Post Office TWGWPOO1.HQGWDOO1 Route nrc.gov Files MESSAGE Mail Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
Size 455 Date & Time 04/18/06 10:36AM None Standard No None No Standard
I Michael Masnik - Blank Bkgrd.gif Page 1 1
z 0
0 CD 2130-06-20273 2 120-062-2944 2
February 24. 2006 CD 0
LUnited States Nuclear Regulatory Commissityn V0 Document Control Desk C
Washington D>C 20555 9)
CD
Subject:
Oyster Creek Generating Station 7
Docket 50-219 0
Non - Routine En-virontmental Operating Report
-o COn January 29. 2006, the Oyster Creek Generating Station plant was secured to facilitate per-forming maintenance on a recirculating water pumnp.
[-his resulted in a minor impact to cold sensitive fish, which was reported to New Jersey Department of Environmental Protection (NJDEP) in accordance with the New Jersey Pollutant Discharge Elimination System permit.
T-he results of this occurrence are detailed in the enclosure to this cover Ietter-If you should require any further information, please contact Ms. Kathy Barnes. of my staff, at 609.971.4970.
Very trl a-rs Oy3ster Creek Generaig Station CNS/KB3/NIEB Enclosure cc:
New Jersey Department of Environmental Protection (3 addressees)
NRC Administratoyr. Region I NRC Senior Project Manager NRC Senior Resident Inspector V0 Co cc
CD z
0 0
CD m
3 CD 0
CD 0
PILANT SUIUTID4DWN N1%4NITCIMN4G RZEP401RT CD Amerien Energy Company, LLC February 2006
CD CO) 0 0
Executive Summary-(D m
During the morning of Wednesday January 25. 2006 Oyster Creek Generating Station (OCOS)
D was operating at 100 0/0 power. At 8:45 AN'4 Wednesday January 25. 2006, Oyster Creek reduced power to 50 %0 power, when a recirculation pump motor experienced an electrical 0
problem.
3 CD Recirculation pumps continuously pump cooling water through the reactor. The plant can operate sately at reduced power with three reactor recirculation pumps. However, OCGS D
Technical Specifications require that the station operate at reduced power if only three reactor 0
recirculating water pumps are available. The plant is most reliable when all five pumps are n
operable. Therefore, the decision was made to complete repairs to both defective recirculating CD pumps as soon as possible, which requires a complete shutdown of OCGS.
On January 26, 2006. AmerGen contacted USNRC and NJDEP and informed them of the D
proposed shutdown, termed the I F09 Outage, and actions the station was taking to minimize the DO effects of the shutdown on the fish populations. Because post-shutdown discharge canal water C
temperatures could be below the lower lethal temperature of some of the fish in the discharge 0
canal, actions were taken intended to mitigate the potential consequences of possible cold-shock effects on the fish population.
The environmental protection plan for I F09 included lowering reactor power at a slow rate of approximately I degree F / hour. so that the rate of change of discharge canal water temperature would not stress the fish within the canal. Additionally, the environmental protection plan included extensive plans to maintain water temperatures in a portion of the discharge canal as high as possible during the plant shutdown in order to provide a thermal refuge for the fish. Two temporary portable boilers, each of approximately 6.7 N4BT-J/hr capacity, were used post-shutdown to heat water and cycle it through heating coils submerged in the OCGS discharge canal. Two concentric booms were arranged in a manner intended to contain most of the heated water in one area of the canal, while allowing free movement by the fish into and out of the heated area.
A gradual shutdown from 5007% power was commenced during the morning of January 28. 2006, and the OCGS achieved 00%0 power at 10:30 PM4. Although no stressed or dead fish were observed immediately, dead bluefish began to be observed at 4:40 AN'! on January 29. 2006.
Timely notifications of this event were made to NRC Region I as well as NJDEP. A few additional dead fish were collected as late as February 3. with a total of 80 dead fish being collected. Over 97% of the dead fish were bluefish, and one specimen each of scup and gizzard shad were also collected.
Attempts were made prior to the plant shutdown to identify what fish species inhabited the discharge canal. The fish protection and identification efforts were supplemented by extensive efforts using a variety of gear to remove for beneficial use from the discharge canal any cold-sensitive fish such as bluefish that would be most at risk for cold-shock subsequent to shutdown.
Furthermore, a beneficial use for those fish subject to cold-shock was planned by arranging for the processing, freezing and subsequent donation of those fish to a local aquarium. These efforts
0, 0
resulted in over 400 pounds of frozen fish filets being prepared and donated to a local aquarium.
0 AmerGen's extensive measures to achieve a beneficial use of the natural resources at risk was commended by NJDEP Conservation Officers witnessing the etforts to be an unprecedented CD level of environmental stewardship.
I'he donated fish filets were primarily bluefish, as well as m
lesser numbers of spotted sea trout and weakfish. Because of the extensive and proactive actions D
of station personnel, the potential extent of cold shock on fish in the discharge canal and S
magnitude of detrimental environmental impacts was effectively reduced.
0 Introduction CD This report documents the results of aquatic sampling conducted by AmerGen Energy Company, D)
LLC (AmerGen) prior to and following a cold-shock event which occurred between January 29 Q
and February 3, 2006, in the discharge canal of Oyster Creek Generating Station (OCGS),
V subsequent to a forced maintenance shutdown of the plant. The objectives of the sampling (D
program were to:
- 1)
Determine the species composition, relative abundance and distribution of fishes in the OCGS discharge canal prior to and following the OCGS shutdown, CD
- 2)
Remove from the discharge canal those fish that may be at risk of cold-shock for 0
beneficial use (i.e., subsequent donation), and
- 3)
Quantify the extent of any fish mortalities.
i The monitoring effort took place from January 28 through February 5, 2006.
During the morning of Wednesday January 25, 2006 Oyster Creek Generating Station (OCGS) was operating at 100 'X. power with four circulating water and two dilution pumps in operation.
At 8:45 ANM Wednesday January 25, 2006, Oyster Creek reduced power to 50 I/16, because two of the station's five reactor recirculation pumps were inoperable. A gradual shutdown from 50°/O power at a rate of only about 1 degree F / hour was commenced during the morning of January
- 28. 2006, and the OCOS achieved 0%A power at 10:30 PM.
Discharize Canal Monitorine Activities Fish were collected from the discharge canal subsequent to the plant shutdown using dip nets by environmental consultants. Dead fish were gathered from a small boat, as well as by personnel walking along the discharge canal banks between the OCGS discharge and the bay front beaches near the mouth of Oyster Creek.
The results of the monitoring effort indicated that a total of 80 fish representing three different fish species died during this plant shutdown event. Most of the stressed or dead fish were bluefish that were collected from upstream portions of the discharge canal and shallow cove areas between the U. S. Route 9 bridge surface water and the mouth of Oyster Creek. The fish captured were identified, enumerated, and length ranges were determined for each species.
CD Cl) 0 Bluefish Pomatomus saltatrix (n = 78) accounted for 97.5% of the mortalities. Northern scup0 Stcnotomus chrvsovs (n = 1) and gizzard shad Dorosoma ceDedianum (n = 1) accounted for the remaining 2.5%.
The bluefish collected ranged from 410 to 860 mm (16.1 to 33.8 in) fork CD length (FL). The Northern scup specimen collected during this event was 247 mm (9.7 in) FL, m
and the gizzard shad was 195 mm (7.7 in) FL. Invertebrates were not involved in the event.
Discussion and Conclusions 0:3 T-he evidence indicates that the observed fish mortalities on January 29. 2006 and the days 3D immediately thereafter were caused by cold-shock.
These fish, primarily bluefish, were residing in the heated condenser discharge of the OCOS and the discharge canal at the time of the plant shutdown. They were probably attracted to the elevated temperatures in the discharge canal 0
during summer or early fall, and remained there. The death of these fish is consistent with what V
is known about their thermal tolerances, lower lethal temperature limits and past observations of CD cold-shock events.
0 As part of an extensive fish protection plan for this shutdown, two temporary portable boilers were used post-shutdown to heat water and cycle it through heating coils submerged in the OCGS discharge canal. Two concentric booms were arranged around the heated water in one D
area of the canal, allowing free movement by the fish into and out of the heated area, as well as 0
providing a limited area of heated water as a thermal refuge for the fish. Observations made with an underwater camera confirmed that the heating boilers and heating coils attracted relatively large numbers of fish at various times during and following the reduction in plant discharge temperatures-Use of the underwater camera also allowed a determination of what cold-sensitive species were present in the discharge canal. This information was useful in targeting these fish for selective removal for subsequent donation to a local aquarium for use as fish food.
The January 29, 2006 plant shutdown event resulted from the inability of some of the fish species inhabiting the OCGS discharge canal to tolerate the relatively cold water temperatures they encountered in the discharge canal subsequent to shutdown of the plant. Intake canal temperatures were about 2.8 IC (37.1 IF), at the time of the OCGS ramp down on January 28 (Figure 1). The Main Condenser discharge temperature at the time of the shutdown was approximately 11. I 0 C (52 IF), resulting in a delta T of about 8.3 0 C (15 0 F). The gradual decrease in discharge canal temperature that occurred following the OCGS shutdown (Figure 1) appears to have been effective in protecting all but the most cold-sensitive species. The discharge canal temperature decreased to about 3.4 0 C (38.2 0 F) at the Route 9 Bridge surface water about thirty hours after the plant shutdown, then remained below 8.9 IC (48 IF) until after the OCOS power ascension began early during the morning of February 5 (Figure 2).
At OCOS, several fish species collected during this event (including bluefish. Northern scup and gizzard shad) have been involved in cold shock events on previous occasions. However, large numbers of striped bass and a few winter flounder were observed to be within the discharge canal but appeared to be unaffected by the post-shutdowvn water temperature changes.
I-ran bwlk1
-Ik horns"t U.g ONIF O U
~MU Uin KIUO "
cur asI b
-mmr
l
.f
.i
. 1N ' L --
pzz
_ L A -a i
11 Soe I
minwuJ F401 l 9 sjpd iiod es uo le ied o Iesu ewuo J!Au 3
eu! ino U-uoN -
Aus er ~ je
kt~WhinphRM Ami.Rawo arn S
eW OX NMN an RM U,--
-- as
-U T
~
F~ip2 I -U~
^pioe o~id eULuJAB u~o-o isj~ eLo I
I o^n n
I L Outed lpd-vodoU uoijujado leluewuojiAU3 OulInoH-uON - PsBVY 1991431W j I :-i.La