Email: Supplemental Letter W/ Upper Shelf Energy Info - RAI 4.2.2-1
ML061500339
Person / Time
Site: Oyster Creek
Issue date: 05/15/2006
From: Hufnagel J
Exelon Corp
To: Ashley D, Veronica Rodriguez
Office of Nuclear Reactor Regulation
References
%dam200606, TAC MC7624
Download: ML061500339 (14)


Text

F5. -Ash[ey - Supplemental letter w/ Upper Shelf Energy into - RAI 4.Zý_i Page 1I D. Ashley - Supplemental letter w/ Upper Shelf Energy info - RAI 4.2.2-1 Page 1 1 From:

<john.hufnagel@exeloncorp.com>

To:

<djal @nrc.gov>, <vmrl @ nrc.gov>

Date:

05/15/2006 12:50:50 PM

Subject:

Supplemental letter w/ Upper Shelf Energy info - RAI 4.2.2-1 Donnie and Veronica, Attached is letter 2130-06-20332, which provides additional information related to RAI 4.2.2-1, relating to Upper Shelf Energy. In our RAI response letter 2130-06-20298, dated April 26, 2006, we indicated we would provide this additional information by May 15. Please pass on to those interested.

Let me know if you have any questions.

As always, this is being processed through the Document Control Desk as a hard copy submittal.

-John.

<<5-15-06 Suppplement providing USE information.pdf>>

This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.

This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout.

Thank You.

I cAtemD\\GW100001.T? P Paae 14 cAtemD\\GWIOOOO1.TMP Paae 1 4 I

~.

I Mail Envelope Properties (4468B160.136 : 5 :41270)

Subject:

Creation Date:

From:

Created By:

Supplemental letter w/ Upper Shelf Energy info - RAI 4.2.2-1 05/15/2006 12:49:47 PM

<john.hufnagel @exeloncorp.com>

john.hufnagel @exeloncorp.com Recipients nrc.gov OWGWP01.HQGWDO01 DJA1 (D. Ashley) nrc.gov TWGWP01.HQGWDO01 VMR1 (Veronica Rodriguez)

Post Office OWGWP01.HQGWDO01 TWGWPOO1.HQGWDO01 Route nrc.gov nrc.gov Files Size Date & Time MESSAGE 1446 15 May, 2006 12:49:47 PM TEXT.htm 2182 5-15-06 Suppplement providing USE information.pdf 257076 Mime.822 358153 Options Expiration Date:

Priority:

Reply Requested:

Return Notification:

Concealed

Subject:

Security:

None Standard No None No Standard

15-06 SuDmlement Drovidina USE informatio Paue 1 D. Ashlev-5-15-OGSuDooIement orovidina USE information.odf Paae 1 t~

AmerGen-,

Michael P. GCallgheT, PE T-*iephoie r o.7b65.$958 An Exelon Company Vice President www exelmn.oripcoim l'-ense Penevaii Pvojects 10 CFR 50 Amen 10 CFR 51 2orl Explon w-*y 10 CFR 54 KSAil-[

Ke neft Square, PA 19448 2130-06-20332 May 15, 2006 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility Operating Ucense No. DPR-16 NRC Docket No. 50-219

Subject:

Supplemental Information for Response to NRC Request for Additional Information, dated March 30, 2006, Related to Oyster Creek Generating Station License Renewal Application (TAC No. MC7624)

Reference:

(1) "Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (TAC No.

MC7624),* dated March 30, 2006 (2) Response to NRC Request for Additional Information related to Sections 4.2 and 4.7 of the Oyster Creek Generating Station License Renewal Application (TAC No. MC7624), dated April 26,2006 In the reference (1) letter, the NRC requested additional information related to Sections 4.2 and 4.7 of the Oyster Creek Generating Station License Renewal Application (LRA). Reference (2) provided the information requested by the NRC staff, however, as noted in the response to RAI 4.2.2-1, AmerGen planned to supplement the response with the results of the calculations of the Upper Shelf Energy equivalent margin analysis for non-limiting reactor vessel beltline materials.

The results of these additional calculations are provided In the enclosure.

If you have any questions, please contact Fred Polaski, Manager Ucense Renewal, at 610-765-5935.

I declare under penalty of perjury that the foregoing is true and correct.

Respectfully, Executed on Michael P. Gallagher' Vice President, Ucense Renewal AmerGen Energy Company, LLC

15-06S upp m*t roviding USE information.

f Pa U.S. Nuclear Regulatory Commission May 15, 2006 Page 2 of 2

Enclosure:

Upper Sheff Energy Equivalent Margin Analysis Results For Non-limiting Reactor Vessel Beltline Materials.

cc:

Regional Administrator, USNRC Region I, w/o Enclosure USNRC Project Manager, NRR - Ucense Renewal, Safety, w/Enclosure USNRC Project Manager, NRR - Ucense Renewal, Environmental, w/o Enclosure USNRC Project Manager, NRR - OCGS, w/o Enclosure USNRC Senior Resident Inspector, OCGS, w/o Enclosure Bureau of Nuclear Engineering, NJDEP, w/Enclosure File No. 05040

D. Arhney 15-6 6Supplement rovidin USE information.pdf Page 3 Enclosure Page 1 of 10 Enclosure Upper Shelf Energy Equivalent Margin Analysis Results For Non-limiting Reactor Vessel Beltline Materials

[D. Ashlev 15-06 Suppplemeint plýovidinq USE intormation.pdt, page 4 1 0.Ahe

-506Sppeetpovdn SZnomainpfPg Enclosure Page 2 of 10 OCGS RPV Plate Equivalent Margin Analysis R(2 PLATE (OCGS Plate Number 564-03A)

(OCGS Code Number G-8-7)

Surveillance Plate USE:

%Cu =

0.17 Capsule Fluence =

0.746x10I8 n/cm2 Measured % Decrease =

0.6 (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

14 (R.G. 1.99, Figure 2)

Lower Intermediate Beltline Plate USE:

%Cu =

0.21 50 EFPY Peak ID Fluence =

6.97 x 1018 n/cm2 50 EFPY 1/4T Fluence =

4.39 x 108 nf/cm 2 R.G. 1.99 Predicted % Decrease =

24.8 Adjusted % Decrease =

NIA (R.G. 1.99, Figure 2)

(R.G. 1.99, Position 2.2) 1 24.8% 5 29.5%. so plate is bounded by equivalent margin analysis.

I

D. Ashley 15-06 Suppplement providing USE information.pdf Page 5 ~I D. Ashley 15-06 Suppplernent providing USE information.pdf Page 5 1 Enclosure Page 3 of 10 OCGS RPV Plate Equivalent Margin Analysis BWIR2 PLATE (OCGS Plate Number 564-038)

(OCGS Code Number G-8-8)

Surveillance Plate USE:

%Cu =

0.17 Capsule Fluence =

0.746x1018 n/cm2 Measured % Decrease =

0.6 (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

14 (R.G. 1.99, Figure 2)

Lower Intermediate Beltline Plate USE:

%Cu =

0.18 50 EFPY Peak ID Fluence =

6.97 x 1018 n/cm2 50 EFPY 1/4T Fluence =

4.39 x 1018 n/cm 2

R.G. 1.99 Predicted % Decrease =

22.3 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 22.3% ! 29.5%, so plate is bounded by equivalent margin analysis.

D. Ashley 15-06 Suppplement providing USE information.pcdf Page 6 Enclosure Page 4 of 10 OCGS RPV Plate Equivalent Margin Analysis BWR/2 PLATE (OCGS Plate Number 564-03C)

(OCGS Code Number G-8-6)

Surveillance Plate USE:

%Cu =

0.17 Capsule Fluence =

0.746x1018 n/cm 2 Measured % Decrease =

0.6 (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

14 (R.G. 1.99. Figure 2)

Lower Intermediate Beltline Plate USE:

%Cu =

0.20 50 EFPY Peak ID Fluence =

6.97 x 1018 n/cm2 50 EFPY 1/4T Fluence =

4.39 x 101e n/cm2 R.G. 1.99 Predicted % Decrease =

24.0 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 24.0% S 29.5%, so plate is bounded by equivalent margin analysis.

D. Ashlev 15-06 SUDPPleMent providinq USE information.pdt Pacie 7 J 1506 Su~c~iment roviina UE-----------------

7 t Enclosure Page 5 of 10 OCGS RPV Plate Equivalent Margin Analysis BWRD2 PLATE (OCOS Plate Number 664-03D)

(OCGS Code Number G-307-1)

Surveillance Plate USE:

%Cu =

0.17 Capsule Fluence =

0.746x10'e n/cm2 Measured % Decrease =

0.6 (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

14 (R.G. 1.99, Figure 2)

Lower Beltline Plate USE:

%Cu =

0.17 50 EFPY Peak ID Fluence =

3.76 x 10We n/cm2 50 EFPY 1/4T Fluence =

2.37 x 10'* n/cm 2

R.G. 1.99 Predicted % Decrease =

18.6 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 22) 18.6% < 29.5%, so plate is bounded by equivalent margin analysis.

D. Ashley 15-06 Supplement providing USE information: dif Page 8f Enclosure Page 6 of 10 OCGS RPV Plate Equivalent Margin Analysis WRI/2 PLATE (OCGS Plate Number 564-03E)

(OCGS Code Number G-308-1)

Surveillance Plate USE:

%Cu =

0.17 Capsule Fluence =

0.746x1Ols n/cm2 Measured % Decrease =

0.6 (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

14 (R.G. 1.99, Figure 2)

Lower Beitline Plate USE:

%Cu =

0.17 50 EFPY Peak ID Fluence =

3.76 x 1018 n/cm 2

50 EFPY 114T Fluence =

2.37 x 10'a n/cmf R.G. 1.99 Predicted % Decrease =

18.6 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 18.6% S 29.5%, so plate is bounded by equivalent margin analysis.

D. Ashlev = 5=15-06 Suppplement providing USE intormation.pdf Pacie 91 D. Ashley 15-06 SuDDDlement Drovidina USE inforrnation.Ddf Paae 9 ~

Enclosure Page 7 of 10 OCGS RPV Plate Equivalent Margin Analysis BWR/2 PLATE (OCGS Plate Number 664-03F)

QOCGS Code Number G-307-6)

Surveillance Plate USE:

%Cu =

0.17 Capsule Fluence =

0.746x10'e n/cm2 Measured % Decrease =

0.6 (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

14 (R.G. 1.99, Figure 2)

Lower Bettline Plate USE:

%Cu =

0.27 50 EFPY Peak ID Fluence =

3.76 x 1018 n/cm2 50 EFPY 1/4T Fluence =

2.37 x 10'a n/cm2 R.G. 1.99 Predicted % Decrease =

26.0 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 26.0%s S29.5%. so plate is bounded by equivalent margin analysis.

D. Ashley 15-06 SUDDDlernent Drovidina USE information.odf Paae 104 Enclosure Page 8 of 10 OCGS RPV Weld Equivalent Margin Analysis BWR/2 WELD, (OCGS Weld Numbers 2-564A. 2-5648, and 2-564C)

(OCGS Heat Number 860548)

Surveillance Weld USE:

%Cu =

0.28 Capsule Fluence =

0.746x1018 n/cm2 Measured % Decrease =

Not reported (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

Not reported (R.G. 1.99. Figure 2)

Beittine Lower Intermediate Shell Axial Weld USE:

%Cu =

0.206 50 EFPY Peak ID Fluence =

6.16 x 10"' n/cm2 50 EFPY 1/4T Fluence =

3.88 x I0'a n/cm2 R.G. 1.99 Predicted % Decrease =

28.6 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 28.6% < 39%, so weld is bounded by equivalent margin analysis.

D. Ashley 15-06 Suppplement providinO USE information.pdf Pane 11 D. Ashley 15-06 Suppplemnent providing USE information.pdf Paoe 11 Enclosure Page 9 of 10 OCGS Vessel RPV Welds Equivalent Margin Analysis BWRI2 WELD. (OCGS Weld Numbers 2-564D. 2-564E. and 2-564F)

(OCGS Heat Number 86054B)

Surveillance Weld USE:

%Cu =

0.28 Capsule Fluence =

0.746x101' nWcM 2

Measured % Decrease =

Not reported (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

Not reported (R.G. 1.99, Figure 2)

Beftline Lower Shell Axial Weld USE:

%Cu =

0.214 50 EFPY Peak ID Fluence =

3.71 x 1018 /c-mi 50 EFPY 1/4T Fluence =

2.34 x 1018 rJ/Cn 2

R.G. 1.99 Predicted % Decrease =

25.5 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 25.5% S 390/%, so weld Is bounded by equivalent margin analysis.

D. Ashley 15-06 SuppPlement providinq USE information.Dpdf I~i Enclosure Page 10 of 10 OCGS Vessel RPV Weld Equivalent Margin Analyses BWR/2 WELD, (OCGS Weld Number 3-564)

(OCOS Heat Number 1248)

Surveillance Weld USE:

%Cu =

0.28 Capsule Fluence =

0.746x10i8 n/cm2 Measured % Decrease =

Not reported (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

Not reported (R.G. 1.99, Figure 2)

Bettline Lower Shell to Lower Intermediate Shell Circumferential Weld USE:

%Cu =

0.214 50 EFPY Peak ID Fluence =

3.76 x 108 n/cm2 50 EFPY 1/4T Fluence =

2.37x 10 s m

R.G. 1.99 Predicted % Decrease =

25.0 (R.G. 1.99, Figure 2)

Adjusted % Decrease =

N/A (R.G. 1.99, Position 2.2) 25.0r/%

39%, so weld is bounded by equivalent margin analysis.