Other: ML052690388, ML052850300, ML053250326, ML053410352, ML053410369, ML053410372, ML053420167, ML053460234, ML053470213, ML053470434, ML053500440, ML053540079, ML060200084, ML060320211, ML060370508, ML060410649, ML060600122, ML060660177, ML060690026, ML060690130, ML060830564, ML060830567, ML060870126, ML060870147, ML060890080, ML060930255, ML060940146, ML060950408, ML060960563, ML060960568, ML060960602, ML061010639, ML061010644, ML061010646, ML061020614, ML061020616, ML061020638, ML061030419, ML061070304, ML061070306, ML061070307, ML061070309, ML061070310, ML061070319, ML061070321, ML061070329, ML061070395, ML061070398, ML061070399, ML061070403... further results
|
MONTHYEARML0726804681954-12-31031 December 1954 New Jersey Department of Environmental Protection, Division of Parks and Forestry, State Forest Service, New Jerseys Big Trees Project stage: Other ML0726705561963-01-31031 January 1963 Us Fish and Wildlife Service, 1963. Distribution of Shellfish Resources in Relation to the New Jersey Intracoastal Waterway -- Manasquan Inlet to Little Egg Harbor. Boston, Ma. January Project stage: Other ML0726405941972-11-17017 November 1972 Jersey Central Power & Light Company, Oyster Creek Nuclear Generating Station Environmental Report, Amendment 2 Project stage: Other ML0726406651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration Project stage: Other ML0726703621978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Initial Progress Report, December 1966, Through Third Progress Report, January 1968 Project stage: Other ML0726703651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Fourth Progress Report 1968 Through Sixth Progress Report 1970, Concluding Remarks Project stage: Other ML0726703681978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Seventh Progress Report, June 25, 1971, Through Eighth Progress Report, August 18, 1972 Project stage: Other ML0726703741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Zooplankton of Barnegat Bay: the Effect of Oyster Creek Nuclear Power Plant Through Literature Cited Project stage: Other ML0726704911978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix E Through Appendix F, Figure 10 Project stage: Other ML0726705501978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix a Through Appendix C1, Figure C1-1 Project stage: Other ML0726801491978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Addendum to Appendix C1 Through Addendum to Appendix D1 Project stage: Other ML0726801691978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Preface Through Table 6.2-2 Project stage: Other ML0726801741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix C Continued Page C2-1 Through Page C6-51 Project stage: Other ML0726802291979-10-22022 October 1979 Letter from David N. Kinsey (New Jersey Department of Environmental Protection) Dated October 22, 1979 to Ivan R. Finfrock (Jersey Central Power & Light Company), NPDES Permit Renewal Application No. NJ0005550 Project stage: Other ML0726405991982-05-14014 May 1982 Jersey Central Power & Light Co. Boundary Map of Former Finninger Farm Project stage: Other ML0726705601986-12-12012 December 1986 Inventory of New Jerseys Estuarine Shellfish Resources, Joseph, J. W., Us Department of Commerce National Oceanic and Atmospheric Administration, National Marine Fisheries Service, December 12, 1986 Project stage: Other ML0726801891987-12-0909 December 1987 Joseph, J. W. 1987, Inventory of New Jerseys Estuarine Shellfish Resources, Us Department of Commerce National Oceanic and Atmospheric Administration National Marine Fisheries Service. Project No. 3-405-R Project stage: Other ML0726703911989-12-31031 December 1989 Lacey Township, Ocean County, New Jersey. 1989. Ocean County Water Quality Management Plan, Wastewater Management Plan Project stage: Other ML0726704221989-12-31031 December 1989 Usda. 1989. Soil Survey of Ocean County, New Jersey. Sheet Number 45 Project stage: Other ML0610206381990-11-26026 November 1990 Drywell Containment, Attachment 1 to Letter Dated 04/07/2006 Project stage: Other ML0610206141991-03-0404 March 1991 Letter Forwarding, an ASME Section Viii Evaluation of Oyster Greek Drywell for Without Sand Case Part 1 Stress Analysis, Attachment 2 to Letter Dated 04/07/06 Project stage: Other ML0610206161992-01-16016 January 1992 Letter Forwarding, ASME Section Viii Evaluation of the Oyster Creek Drywell, Part 2, Stability Analysis, Attachment 3 to Letter Dated 04/07/2006 Project stage: Other ML0702906681992-04-24024 April 1992 Evaluation Report on Structural Integrity of the Oyster Creek Drywell with Brookhaven National Laboratory Technical Evaluation Report - Attached Project stage: Other ML0726801841997-02-0404 February 1997 State of New Jersey Permit No. 1512-93-0052.3, .4, and .5, Permit to Dredge Project stage: Other ML0726804281997-09-30030 September 1997 Department of the Army, Corps of Engineers, Permit Number CENAP-OP-R-199701765-39 Project stage: Other ML0726704171997-10-31031 October 1997 State of New Jersey Department of Environmental Protection. the Management and Regulation of Dredging Activities and Dredged Material Disposal in New Jerseys Tidal Waters. October 1997 Project stage: Other ML0726703842000-04-25025 April 2000 Levin, S. 2000. Letter, Levin (Gpu Nuclear Inc.) to New Jersey Department of Environmental Protection. Application for Transfer of Ownership and of a Permit Project stage: Request ML0726804482002-05-15015 May 2002 New Jersey Department of Environmental Protection. 2002. List of State Flood Hazard Area Delineations. May 15 Project stage: Other ML0726803802003-05-15015 May 2003 Shellfish Stock Assessment of Little Egg Harbor Bay (Dsrt Proposal 2001011), Celestino, M. P., New Jersey Department of Environmental Protection, 15 May 2003 Project stage: Other ML0726803592003-12-31031 December 2003 Private Property and the Common Good, Anonymous, 2003, Powerpoint Presentation Project stage: Other ML0726704012004-01-31031 January 2004 Energy Information Administration. 2004. State Energy Profiles 2002. January. (Excerpt). Us Department of Energy Project stage: Other ML0726802382004-02-28028 February 2004 Clean, Safe, Reliable, the Economic Benefits of Oyster Creek Generating Station, February 2004 Project stage: Other ML0726804052004-07-0707 July 2004 Ecolsciences, Inc., 2004, Threatened and Endangered Species Habitat Impact Assessment for Oyster Greek Generation Station National Security Upgrades; Township of Lacey; Ocean County, New Jersey, Prepared for Amergen Energy Co., LLC Project stage: Other ML0726704042004-12-31031 December 2004 Energy Information Administration. 2004. State Energy Data 2002: Consumption. Table 7 Energy Consumption Estimates by Source, Selected Years, 160-2002, New Jersey. Us Department of Energy Project stage: Other ML0726705522004-12-31031 December 2004 New Jersey Department of Environmental Protection, 2004 Cafra Boundary Line Project stage: Other ML0726804182004-12-31031 December 2004 Energy Information Administration, 2004, Existing Generating Units in the United States by State, Company, and Plant, 2004, Us Department of Energy Project stage: Other ML0726703942005-07-19019 July 2005 Tompkins, H.B. 2005. Letter Tompkins (State of New Jersey, Department of Environmental Protection) to Brown (Amergen). Draft Surface Water Renewal Permit Action. Includes Public Notice, Fact Sheet, and Draft NJPDES Permit Project stage: Draft Other ML0726808302005-07-19019 July 2005 Ocean County Soil Conservation District, 2005, Soil Erosion and Sedimentation Control Certification; Upland Dredge Site, Scd 1302 Project stage: Other ML0520800482005-07-22022 July 2005 Application for Renewed Operating License Project stage: Request ML0726802022005-07-25025 July 2005 FEMA Floodzone Map for Lacey Township, Ocean County, Nj, Provided by Birdsall Engineering, Inc Project stage: Other ML0526903882005-09-23023 September 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station Project stage: Other ML0527101572005-09-28028 September 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0528503002005-10-0505 October 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station (Tac No. MC7624) Project stage: Other ML0529100912005-10-12012 October 2005 Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application (Tac No. MC7624) Project stage: Response to RAI ML0610703042005-10-21021 October 2005 Email: Pictures? (PA) Project stage: Other ML0610703062005-11-0404 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0610703072005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0531400422005-11-0909 November 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0610703092005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0532004752005-11-11011 November 2005 Supplemental Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application Project stage: Supplement 2002-05-15
[Table View] |
Text
D. Ashley - Responses to three more AMP questions O-agiiT]
From:
<john.hufnagel @ exeloncorp.com>
To:
<djal @nrc.gov>, <rkm~nrc.gov>
Date:
03/31/2006 12:04:19 PM
Subject:
Responses to three more AMP questions Donnie & Roy, The attached three Responses (to questions AMP-359, AMP-360 and AMP-362) are provided for your review. These three were included in the 3/17/06 e-mail from Donnie Ashley to George Beck. It was agreed they would be addressed in the Q & A database since they originate from the Audit.
Note that we are busy finalizing responses to the last seven database questions, related to the drywell, and expect to get those to you early next week to facilitate completion of your review and Audit report. If you have any questions, please contact me. Thanks.
- John.
<> <> <>
This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.
This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout. Thank You.
CC:
<donald.warfel @exeloncorp.com>, <George.Beck@exeloncorp.com>,
<fred.polaski @ exeloncorp.com>
I c:\\temp-\\-G-W-10-0001.TMP
....1, Paae 1 I c:\\temp\\GW}OOOO1.TMP Paae 1 1 l
MailEnvelopeProperties (442D610A.B3B:10:27451)
Subject:
Creation Date:
From:
Responses to three more AMP questions 03/31/2006 12:03:48 PM
<john.hufnagel @exeloncorp.com>
Created By:
john.hufnagel @exeloncorD.com Recipients nrc.gov OWGWPOO1.HQGWDOO1 DJA1 (D. Ashley) nrc.gov TWGWPO01.HQGWDO01 RKM (Roy Mathew) exeloncorp.com fred.polaski CC George.Beck CC donald.warfel CC Post Office OWGWPOO1.HQGWDO01 TWGWPOO1.HQGWDOO1 Files Size MESSAGE 1591 TEXT.htm 2434 Q & A Database Response AMP-362.pdf Q & A Database Response AMP-360.pdf Q & A Database Response AMP-359.pdf Mime.822 256074 Route nrc.gov nrc.gov exeloncorp.com Date & Time 31 March, 2006 12:03:48 PM 61063 58797 61821 Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
None Standard No None No Standard
NR CInformation RequestFo Item No Date Received:
Source AMP-359 3/16/2006 AMP Audit Topic:
Status:
Open Lubricating Oil Analysis Program - FRCT (AMP B.1.39)
Document
References:
NRC Representative Davis, Jim AmerGen (Took Issue):
Beck, Chip Ouestion This question was received from Donnie Ashley, NRC Project Manager on 3/14/06 as a draft RAI. On 3/16/06 it was agreed that it would be addressed in the Q&A database since it originates from the audit (Roy Matthew). Subsequently included in 3/17/06 email from Donnie Ashley to George Beck The Lubricating Oil Analysis Program - FRCT (OCGS AMP B.1.39) takes exception to the GALL Report requirement to monitor flash point.
The basis provided for exceptions to GALL, Element 3 (Parameters Monitored or Inspected) is not valid since the Flash Point of an industrial lubricant is an important test to determine if light-end hydrocarbons are getting into the oil through seal leaks or other means. It is an effective way to monitor seal performance in light end hydrocarbon compressors. Low Flash Points pose a safety hazard in the event of component failure that can generate heat above the flash point of the oil, such as bearing failure.
Please justify the reason for not monitoring the flash point of lubricating oil at the FRCT and why this exception is acceptable to manage the effects of aging for which it is credited.
Assigned To:
Beck, Chip
Response
The Lubricating Oil Analysis Program - FRCT (PBD-AMP-1.39) will be revised to include measurement of flash point.
(This is consistent with PBD-AMP-B.2.02 Lubricating Oil Monitoring Activities)
LRCR #:
292 LRA A.5 Commitment #:
IR#:
Approvals:
NRC Information Request Forml Prepared By:
Beck, Chip 3/30/2006 Reviewed By:
Muggleston, Kevin 3/30/2006 Approved By:
Warfel, Don 3/30/2006 NRC Acceptance (Date):
NR CIntformation RequestFom Item No Date Received:
Source AMP-360 3/17/2006 Topic:
Status:
Open PBD-AMP-B.2.2 Lubricating Oil Monitoring Activities Document
References:
NRC Representative Davis, Jim AmerGen (Tookl Issue):
Beck, Chip Question This question was received in an email from Donnie Ashley, NRC Project Manager, to George Beck, dated 3/17/06.
PBD-AMP-B.2.2, 'Lubricating Oil Monitoring Activities," Element 3 states that oil analysis guidelines will be enhanced to include measurement of flash point for diesel engine lubricating oil. This is a new enhancement based on the reconciliation of this aging management program from the draft January 2005 NUREG-1800, Rev. I to the approved September 2005 NUREG-1 801, Rev. 1. This enhancement is not identified in OCGS LRA B.2.2. Is the LRA supplemented to reflect this?
Assigned To:
Beck, Chip
Response
This enhancement is addressed in the 'Summary of Reconciliation of OC LRA to September 2005 Revision 1 NUREG-1800 and NUREG-1801" transmitted to the NRC on March 30, 2006 (Letter No.
2130-06-20293). This is an addition to the LRA Table A.5 License Renewal Commitment List Item No. 38.
LRCR #:
LRA A.5 Commitment #: 38 IR#:
Approvals:
Prepared By:
Beck, Chip 3/30/2006 ReviewedBy:
Getz, Stu 3/30/2006 Approved By:
Warfel, Don 3/30/2006 NRC Acceptance (Date):
INRC Information Request Forml Item No Date Received:
Source AMP-362 3/17/2006 AMP Audit Topic:
Status:
Open PBD-AMP-B.1.21 Aboveground Outdoor Tanks Document
References:
NRCRepresentative Davis, Jim AmerGen (Took Issue):
Beck, Chip Question This question was received in an email from Donnie Ashley, NRC Project Manager, to George Beck, dated 3/17/06.
PBD -AMP-B.1.21, -Aboveground Outdoor Tanks," identifies an exception to NUREG-1801 for element 5 (The program utilizes tank inspections every 5 years in place of system walkdowns each outage). This exception is not identified in OCGS LRA B1.12.
Is the LRA supplemented to reflect this? What is the basis for this exception? why this exception is acceptable to manage the effects of aging for which it is credited.
Assigned To:
Micklo, Charles
Response
The technical justification for the exception to NUREG-1801 is provided in the response to Item No.
AMP-148. LRCR 231 was written to correct Exelon's documentation. The exception identified does not change any commitment stated in LRA Appendix A. The exception is included in the Question and Answer database, item AMP-148 and in the PBD-AMP-B.1.21 document that have been provided to the NRC. An LRA supplement is not required.
LRCR #:
231 LRA A.5 Commitment #:
IR#:
376714.04.05 Approvals:
Prepared By:
Micklo, Charles 3/30/2006 ReviewedBy:
Muggleston, Kevin 3/30/2006 Approved By:
Warfel, Don 3/30/6006 NRCAcceptance (Date):