Other: ML052690388, ML052850300, ML053250326, ML053410352, ML053410369, ML053410372, ML053420167, ML053460234, ML053470213, ML053470434, ML053500440, ML053540079, ML060200084, ML060320211, ML060370508, ML060410649, ML060600122, ML060660177, ML060690026, ML060690130, ML060830564, ML060830567, ML060870126, ML060870147, ML060890080, ML060930255, ML060940146, ML060950408, ML060960563, ML060960568, ML060960602, ML061010639, ML061010644, ML061010646, ML061020614, ML061020616, ML061020638, ML061030419, ML061070304, ML061070306, ML061070307, ML061070309, ML061070310, ML061070319, ML061070321, ML061070329, ML061070395, ML061070398, ML061070399, ML061070403... further results
|
MONTHYEARML0726804681954-12-31031 December 1954 New Jersey Department of Environmental Protection, Division of Parks and Forestry, State Forest Service, New Jerseys Big Trees Project stage: Other ML0726705561963-01-31031 January 1963 Us Fish and Wildlife Service, 1963. Distribution of Shellfish Resources in Relation to the New Jersey Intracoastal Waterway -- Manasquan Inlet to Little Egg Harbor. Boston, Ma. January Project stage: Other ML0726405941972-11-17017 November 1972 Jersey Central Power & Light Company, Oyster Creek Nuclear Generating Station Environmental Report, Amendment 2 Project stage: Other ML0726406651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration Project stage: Other ML0726703621978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Initial Progress Report, December 1966, Through Third Progress Report, January 1968 Project stage: Other ML0726703651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Fourth Progress Report 1968 Through Sixth Progress Report 1970, Concluding Remarks Project stage: Other ML0726703681978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Seventh Progress Report, June 25, 1971, Through Eighth Progress Report, August 18, 1972 Project stage: Other ML0726703741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Zooplankton of Barnegat Bay: the Effect of Oyster Creek Nuclear Power Plant Through Literature Cited Project stage: Other ML0726704911978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix E Through Appendix F, Figure 10 Project stage: Other ML0726705501978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix a Through Appendix C1, Figure C1-1 Project stage: Other ML0726801491978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Addendum to Appendix C1 Through Addendum to Appendix D1 Project stage: Other ML0726801691978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Preface Through Table 6.2-2 Project stage: Other ML0726801741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix C Continued Page C2-1 Through Page C6-51 Project stage: Other ML0726802291979-10-22022 October 1979 Letter from David N. Kinsey (New Jersey Department of Environmental Protection) Dated October 22, 1979 to Ivan R. Finfrock (Jersey Central Power & Light Company), NPDES Permit Renewal Application No. NJ0005550 Project stage: Other ML0726405991982-05-14014 May 1982 Jersey Central Power & Light Co. Boundary Map of Former Finninger Farm Project stage: Other ML0726705601986-12-12012 December 1986 Inventory of New Jerseys Estuarine Shellfish Resources, Joseph, J. W., Us Department of Commerce National Oceanic and Atmospheric Administration, National Marine Fisheries Service, December 12, 1986 Project stage: Other ML0726801891987-12-0909 December 1987 Joseph, J. W. 1987, Inventory of New Jerseys Estuarine Shellfish Resources, Us Department of Commerce National Oceanic and Atmospheric Administration National Marine Fisheries Service. Project No. 3-405-R Project stage: Other ML0726703911989-12-31031 December 1989 Lacey Township, Ocean County, New Jersey. 1989. Ocean County Water Quality Management Plan, Wastewater Management Plan Project stage: Other ML0726704221989-12-31031 December 1989 Usda. 1989. Soil Survey of Ocean County, New Jersey. Sheet Number 45 Project stage: Other ML0610206381990-11-26026 November 1990 Drywell Containment, Attachment 1 to Letter Dated 04/07/2006 Project stage: Other ML0610206141991-03-0404 March 1991 Letter Forwarding, an ASME Section Viii Evaluation of Oyster Greek Drywell for Without Sand Case Part 1 Stress Analysis, Attachment 2 to Letter Dated 04/07/06 Project stage: Other ML0610206161992-01-16016 January 1992 Letter Forwarding, ASME Section Viii Evaluation of the Oyster Creek Drywell, Part 2, Stability Analysis, Attachment 3 to Letter Dated 04/07/2006 Project stage: Other ML0702906681992-04-24024 April 1992 Evaluation Report on Structural Integrity of the Oyster Creek Drywell with Brookhaven National Laboratory Technical Evaluation Report - Attached Project stage: Other ML0726801841997-02-0404 February 1997 State of New Jersey Permit No. 1512-93-0052.3, .4, and .5, Permit to Dredge Project stage: Other ML0726804281997-09-30030 September 1997 Department of the Army, Corps of Engineers, Permit Number CENAP-OP-R-199701765-39 Project stage: Other ML0726704171997-10-31031 October 1997 State of New Jersey Department of Environmental Protection. the Management and Regulation of Dredging Activities and Dredged Material Disposal in New Jerseys Tidal Waters. October 1997 Project stage: Other ML0726703842000-04-25025 April 2000 Levin, S. 2000. Letter, Levin (Gpu Nuclear Inc.) to New Jersey Department of Environmental Protection. Application for Transfer of Ownership and of a Permit Project stage: Request ML0726804482002-05-15015 May 2002 New Jersey Department of Environmental Protection. 2002. List of State Flood Hazard Area Delineations. May 15 Project stage: Other ML0726803802003-05-15015 May 2003 Shellfish Stock Assessment of Little Egg Harbor Bay (Dsrt Proposal 2001011), Celestino, M. P., New Jersey Department of Environmental Protection, 15 May 2003 Project stage: Other ML0726803592003-12-31031 December 2003 Private Property and the Common Good, Anonymous, 2003, Powerpoint Presentation Project stage: Other ML0726704012004-01-31031 January 2004 Energy Information Administration. 2004. State Energy Profiles 2002. January. (Excerpt). Us Department of Energy Project stage: Other ML0726802382004-02-28028 February 2004 Clean, Safe, Reliable, the Economic Benefits of Oyster Creek Generating Station, February 2004 Project stage: Other ML0726804052004-07-0707 July 2004 Ecolsciences, Inc., 2004, Threatened and Endangered Species Habitat Impact Assessment for Oyster Greek Generation Station National Security Upgrades; Township of Lacey; Ocean County, New Jersey, Prepared for Amergen Energy Co., LLC Project stage: Other ML0726704042004-12-31031 December 2004 Energy Information Administration. 2004. State Energy Data 2002: Consumption. Table 7 Energy Consumption Estimates by Source, Selected Years, 160-2002, New Jersey. Us Department of Energy Project stage: Other ML0726705522004-12-31031 December 2004 New Jersey Department of Environmental Protection, 2004 Cafra Boundary Line Project stage: Other ML0726804182004-12-31031 December 2004 Energy Information Administration, 2004, Existing Generating Units in the United States by State, Company, and Plant, 2004, Us Department of Energy Project stage: Other ML0726703942005-07-19019 July 2005 Tompkins, H.B. 2005. Letter Tompkins (State of New Jersey, Department of Environmental Protection) to Brown (Amergen). Draft Surface Water Renewal Permit Action. Includes Public Notice, Fact Sheet, and Draft NJPDES Permit Project stage: Draft Other ML0726808302005-07-19019 July 2005 Ocean County Soil Conservation District, 2005, Soil Erosion and Sedimentation Control Certification; Upland Dredge Site, Scd 1302 Project stage: Other ML0520800482005-07-22022 July 2005 Application for Renewed Operating License Project stage: Request ML0726802022005-07-25025 July 2005 FEMA Floodzone Map for Lacey Township, Ocean County, Nj, Provided by Birdsall Engineering, Inc Project stage: Other ML0526903882005-09-23023 September 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station Project stage: Other ML0527101572005-09-28028 September 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0528503002005-10-0505 October 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station (Tac No. MC7624) Project stage: Other ML0529100912005-10-12012 October 2005 Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application (Tac No. MC7624) Project stage: Response to RAI ML0610703042005-10-21021 October 2005 Email: Pictures? (PA) Project stage: Other ML0610703062005-11-0404 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0610703072005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0531400422005-11-0909 November 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0610703092005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0532004752005-11-11011 November 2005 Supplemental Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application Project stage: Supplement 2002-05-15
[Table View] |
Text
AmerGenSM Michael P. Gallagher, PE Vice President License Renewal Projects Telephone 610.765.5958 www.exeloncorp.com michaelp.gallagher@exeloncorp.com An Exelon Company 10 CFR 50 10 CFR 51 10 CFR 54 AmerGen 200 Exelcn Way KSA/2-E Kennett Square, PA 19348 2130-03-20331 May 3, 2006 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility Operating License No. DPR-16 NRC Docket No. 50-219
Subject:
Supplemental Response to NRC Request for Additional Information, dated March 20, 2006, Related to Oyster Creek Generating Station License Renewal Application (TAC No. MC7624)
References:
- 1. NRC Letter to AmerGen dated March 20, 2006, "Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (TAC No. MC7624)"
- 2. AmerGen Letter 2130-06-20291, dated April 18, 2006, 'Response to NRC Request for Additional Information, dated March 20, 2006, Related to Oyster Creek Generating Station License Renewal Application (TAC No. MC7624)"
In question RAI 3.1.1-1 of Reference 1, the NRC requested additional information related to AmerGen's plans for future inspections associated with the Isolation Condensers. Reference 2 provided some information regarding those plans. In a follow-up discussion, it was determined that thE! NRC Staff requires some clarification of AmerGen's planned activities. The Enclosure to this letter provides this clarification.
There are no regulatory commitments made in this letter. If you have any questions, please contact Fred Polaski, Manager License Renewal, at 610-765-5935.
I declare under penalty of perjury that the foregoing is true and correct.
Respectfully, Executed on 05- 03-ZoO.Z Michael P. Gallagher Vice President, License Renewal AmerGen Energy Company, LLC
May 3, 2006 Page 2 of 2
Enclosure:
Clarification of Response to RAI 3.1.1-1 cc:
Regional Administrator, USNRC Region I, w/o Enclosure USNRC Project Manager, NRR - License Renewal, Safety, w/Enclosure USNRC Project Manager, NRR - License Renewal, Environmental, w/o Enclosure USNRC Project Manager, NRR - OCGS, w/o Enclosure USNRC Senior Resident Inspector, OCGS, w/o Enclosure Bureau of Nuclear Engineering, NJDEP, w/Enclosure File No. 05040
Enclosure Clarification of Response to RAI 3.1.1-1 May 3, 2006
May 3, 2006 Enclosure!
Page 1 of 2l Enclosure - Oyster Creek Isolation Condenser Monitoring Isolation Condenser System The Oyster Creek Isolation Condenser System has two isolation condensers, each of which contains two tube bundles. When placed into operation, steam from the reactor vessel enters the tube bundles and is condensed, with the resultant condensate returned to the reactor vessel via the Recirculation System in a closed-loop process.
Background
In 1998, both tube bundle assemblies in the "B" isolation condenser were replaced. In 2000, both assemblies in the "A" isolation condenser were replaced. The original tube material was Type 304 stainless steel; the replacement tube material is type 31 6L stainless steel. Due in part to leaking condensate return valves, and a resultant condition where the steam/water interface level internal to the tube bundles occurred at the level of the uppermost tubes, the original tube bundles were subjected to numerous temperature oscillations which accelerated a thermally-induced stress corrosion cracking condition in the tubes. Correction of the condensate return valve leaking condition, and use of a replacement tube bundle using a low-carbon content material more resistant to sensitization during welding (and consequently more resistant to stress corrosion cracking during operation), has substantially reduced the probability of occurrence of a tube leak. The normal steam/water interface, by design, is in the steam inlet piping to the isolation condensers, at an elevation above that of the tube bundles. The isolation condenser tubes are normally filled with condensed steam.
Isolation Condenser Monitoring An isolation condenser tube bundle leak would constitute a breach of the reactor coolant pressure boundary. At Oyster Creek, the isolation condenser shell side water is monitored for temperature and is sampled for radioactivity in order to ascertain the continued integrity of the tube bundles. An increase in shell water temperature or presence of radioactivity in the shell water can indicate a potential tube leak. Shell water level is also monitored; an increase in level can indicate a potential tube leak.
Correction of the condensate return valve leakage condition assures that water/steam interface elevation in the steam supply piping remains well above the level of the tube bundles, thus eliminating a cause of the temperature oscillations that accelerated the stress corrosion cracking in the original tube bundles. Data from temperature elements mounted on the steam inlet piping to the condensers is recorded and is used to ascertain the interface level.
The Oyster Creek Isolation Condenser System contains piping and components of ISI Classes 1, 2, and 3. The isolation condensers are ISI Class 2 on the tube side and ISI Class 3 on the shell side. Testing of the system and components is conducted per the ASME Section Xl ISI program in accordance with requirements of the ASME Code as described in the Oyster Creek License Renewal Application, Appendix B, B.1.1, ASME Section Xl Inservice Inspection, Subsections IWB, IWC, and IWD. For the ISI Class 2 portions of the system, this testing includes an inservice pressure test, with a visual examination of accessible external exposed surfaces of piping and components, at a free uency of three times every ten years. While the isolation condenser tube bundles are part of the pressurized boundary during these tests, the bundle assemblies, located inside the condenser shells, are not accessible and are not directly observed. Shell
May 3, 2006 EnclosurE Page 2 of 2 water temperature, level, and radiation monitoring are the indicators of any presence of isolation condenser tube bundle leakage.
Oyster Creek Isolation Condensers and GALL In accordance with NUREG-1801, Revision 1, Oyster Creek has committed to continued isolation condenser shell water temperature monitoring and sampling for radiation in order to monitor for potential tube leaks. These periodic examinations will continue throughout the period of extended operation. In addition, Oyster Creek has committed toc perlorm eddy current testing of the tubes, with VT or UT examination of the tube sheet and channel head, during the first ten-year period of extended operation. The eddy current testing and examination of the tubesheet and channel head require cutting of ASIME Class 2 piping components, and have been proposed to be performed during the first ten year period of extended operation due to the relatively short service period of the replaced tube bundle assemblies (replaced in 1998 and 2000).
Potential Corrective Action Activities Should Indications of Tube Leakage be Observed Should any of the monitoring activities conducted on the isolation condensers reveal conditions potentially indicative of a tube leak, initiation of the corrective action process would result in an engineering evaluation of the observed condition. Confirmatory testing could be performed, which may include controlled-inventory testing of the shell water volume with the bundle side pressurized, and enhanced radioactivity analysis of shell side water. Upon confirmation of tube leakage, repair or plugging of leaking tubes would be performed, and if warranted, eddy current testing of the bundles to determine extent of condition would be considered. Conceivably, depending on the extent, repair could consist of tube bundle replacement. Appropriate corrective action to correct a tube leakage condition in the isolation condensers would be taken, regardless of when it occurred during the period of extended operation.