Other: ML052690388, ML052850300, ML053250326, ML053410352, ML053410369, ML053410372, ML053420167, ML053460234, ML053470213, ML053470434, ML053500440, ML053540079, ML060200084, ML060320211, ML060370508, ML060410649, ML060600122, ML060660177, ML060690026, ML060690130, ML060830564, ML060830567, ML060870126, ML060870147, ML060890080, ML060930255, ML060940146, ML060950408, ML060960563, ML060960568, ML060960602, ML061010639, ML061010644, ML061010646, ML061020614, ML061020616, ML061020638, ML061030419, ML061070304, ML061070306, ML061070307, ML061070309, ML061070310, ML061070319, ML061070321, ML061070329, ML061070395, ML061070398, ML061070399, ML061070403... further results
|
MONTHYEARML0726804681954-12-31031 December 1954 New Jersey Department of Environmental Protection, Division of Parks and Forestry, State Forest Service, New Jerseys Big Trees Project stage: Other ML0726705561963-01-31031 January 1963 Us Fish and Wildlife Service, 1963. Distribution of Shellfish Resources in Relation to the New Jersey Intracoastal Waterway -- Manasquan Inlet to Little Egg Harbor. Boston, Ma. January Project stage: Other ML0726405941972-11-17017 November 1972 Jersey Central Power & Light Company, Oyster Creek Nuclear Generating Station Environmental Report, Amendment 2 Project stage: Other ML0726406651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration Project stage: Other ML0726703621978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Initial Progress Report, December 1966, Through Third Progress Report, January 1968 Project stage: Other ML0726703651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Fourth Progress Report 1968 Through Sixth Progress Report 1970, Concluding Remarks Project stage: Other ML0726703681978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Seventh Progress Report, June 25, 1971, Through Eighth Progress Report, August 18, 1972 Project stage: Other ML0726703741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Zooplankton of Barnegat Bay: the Effect of Oyster Creek Nuclear Power Plant Through Literature Cited Project stage: Other ML0726704911978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix E Through Appendix F, Figure 10 Project stage: Other ML0726705501978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix a Through Appendix C1, Figure C1-1 Project stage: Other ML0726801491978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Addendum to Appendix C1 Through Addendum to Appendix D1 Project stage: Other ML0726801691978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Preface Through Table 6.2-2 Project stage: Other ML0726801741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix C Continued Page C2-1 Through Page C6-51 Project stage: Other ML0726802291979-10-22022 October 1979 Letter from David N. Kinsey (New Jersey Department of Environmental Protection) Dated October 22, 1979 to Ivan R. Finfrock (Jersey Central Power & Light Company), NPDES Permit Renewal Application No. NJ0005550 Project stage: Other ML0726405991982-05-14014 May 1982 Jersey Central Power & Light Co. Boundary Map of Former Finninger Farm Project stage: Other ML0726705601986-12-12012 December 1986 Inventory of New Jerseys Estuarine Shellfish Resources, Joseph, J. W., Us Department of Commerce National Oceanic and Atmospheric Administration, National Marine Fisheries Service, December 12, 1986 Project stage: Other ML0726801891987-12-0909 December 1987 Joseph, J. W. 1987, Inventory of New Jerseys Estuarine Shellfish Resources, Us Department of Commerce National Oceanic and Atmospheric Administration National Marine Fisheries Service. Project No. 3-405-R Project stage: Other ML0726703911989-12-31031 December 1989 Lacey Township, Ocean County, New Jersey. 1989. Ocean County Water Quality Management Plan, Wastewater Management Plan Project stage: Other ML0726704221989-12-31031 December 1989 Usda. 1989. Soil Survey of Ocean County, New Jersey. Sheet Number 45 Project stage: Other ML0610206381990-11-26026 November 1990 Drywell Containment, Attachment 1 to Letter Dated 04/07/2006 Project stage: Other ML0610206141991-03-0404 March 1991 Letter Forwarding, an ASME Section Viii Evaluation of Oyster Greek Drywell for Without Sand Case Part 1 Stress Analysis, Attachment 2 to Letter Dated 04/07/06 Project stage: Other ML0610206161992-01-16016 January 1992 Letter Forwarding, ASME Section Viii Evaluation of the Oyster Creek Drywell, Part 2, Stability Analysis, Attachment 3 to Letter Dated 04/07/2006 Project stage: Other ML0702906681992-04-24024 April 1992 Evaluation Report on Structural Integrity of the Oyster Creek Drywell with Brookhaven National Laboratory Technical Evaluation Report - Attached Project stage: Other ML0726801841997-02-0404 February 1997 State of New Jersey Permit No. 1512-93-0052.3, .4, and .5, Permit to Dredge Project stage: Other ML0726804281997-09-30030 September 1997 Department of the Army, Corps of Engineers, Permit Number CENAP-OP-R-199701765-39 Project stage: Other ML0726704171997-10-31031 October 1997 State of New Jersey Department of Environmental Protection. the Management and Regulation of Dredging Activities and Dredged Material Disposal in New Jerseys Tidal Waters. October 1997 Project stage: Other ML0726703842000-04-25025 April 2000 Levin, S. 2000. Letter, Levin (Gpu Nuclear Inc.) to New Jersey Department of Environmental Protection. Application for Transfer of Ownership and of a Permit Project stage: Request ML0726804482002-05-15015 May 2002 New Jersey Department of Environmental Protection. 2002. List of State Flood Hazard Area Delineations. May 15 Project stage: Other ML0726803802003-05-15015 May 2003 Shellfish Stock Assessment of Little Egg Harbor Bay (Dsrt Proposal 2001011), Celestino, M. P., New Jersey Department of Environmental Protection, 15 May 2003 Project stage: Other ML0726803592003-12-31031 December 2003 Private Property and the Common Good, Anonymous, 2003, Powerpoint Presentation Project stage: Other ML0726704012004-01-31031 January 2004 Energy Information Administration. 2004. State Energy Profiles 2002. January. (Excerpt). Us Department of Energy Project stage: Other ML0726802382004-02-28028 February 2004 Clean, Safe, Reliable, the Economic Benefits of Oyster Creek Generating Station, February 2004 Project stage: Other ML0726804052004-07-0707 July 2004 Ecolsciences, Inc., 2004, Threatened and Endangered Species Habitat Impact Assessment for Oyster Greek Generation Station National Security Upgrades; Township of Lacey; Ocean County, New Jersey, Prepared for Amergen Energy Co., LLC Project stage: Other ML0726704042004-12-31031 December 2004 Energy Information Administration. 2004. State Energy Data 2002: Consumption. Table 7 Energy Consumption Estimates by Source, Selected Years, 160-2002, New Jersey. Us Department of Energy Project stage: Other ML0726705522004-12-31031 December 2004 New Jersey Department of Environmental Protection, 2004 Cafra Boundary Line Project stage: Other ML0726804182004-12-31031 December 2004 Energy Information Administration, 2004, Existing Generating Units in the United States by State, Company, and Plant, 2004, Us Department of Energy Project stage: Other ML0726703942005-07-19019 July 2005 Tompkins, H.B. 2005. Letter Tompkins (State of New Jersey, Department of Environmental Protection) to Brown (Amergen). Draft Surface Water Renewal Permit Action. Includes Public Notice, Fact Sheet, and Draft NJPDES Permit Project stage: Draft Other ML0726808302005-07-19019 July 2005 Ocean County Soil Conservation District, 2005, Soil Erosion and Sedimentation Control Certification; Upland Dredge Site, Scd 1302 Project stage: Other ML0520800482005-07-22022 July 2005 Application for Renewed Operating License Project stage: Request ML0726802022005-07-25025 July 2005 FEMA Floodzone Map for Lacey Township, Ocean County, Nj, Provided by Birdsall Engineering, Inc Project stage: Other ML0526903882005-09-23023 September 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station Project stage: Other ML0527101572005-09-28028 September 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0528503002005-10-0505 October 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station (Tac No. MC7624) Project stage: Other ML0529100912005-10-12012 October 2005 Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application (Tac No. MC7624) Project stage: Response to RAI ML0610703042005-10-21021 October 2005 Email: Pictures? (PA) Project stage: Other ML0610703062005-11-0404 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0610703072005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0531400422005-11-0909 November 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0610703092005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0532004752005-11-11011 November 2005 Supplemental Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application Project stage: Supplement 2002-05-15
[Table View] |
Text
AmerGen SM Michael P. Gallagher, PE Vice President License Renewal Projects Telephone 61o.765.5958 www.exeloncorp.com michaelp.gallagher@exeloncorp.com An Exelon Company 10 CFR 50 10 CFR 51 10 CFR 54 AmerGen 200 Exelon Way KSA/2-E Kennett Square, PA 19348 2130-06-20332 May 15, 2006 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility Operating License No. DPR-16 NRC Docket No. 50-219
Subject:
Supplemental Information for Response to NRC Request for Additional Information, dated March 30, 2006, Related to Oyster Creek Generating Station License Renewal Application (TAC No. MC7624)
Reference:
(1) "Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (TAC No.
MC7624)," dated March 30, 2006 (2) Response to NRC Request for Additional Information related to Sections 4.2 and 4.7 of the Oyster Creek Generating Station License Renewal Application (TAC No. MC7624), dated April 26, 2006 In the reference (1) letter, the NRC requested additional information related to Sections 4.2 and 4.7 of the Oyster Creek Generating Station License Renewal Application (LRA). Reference (2) provided the information requested by the NRC staff, however, as noted in the response to RAI 4.2.2-1, AmerGen planned to supplement the response with the results of the calculations of the Upper Shelf Energy equivalent margin analysis for non-limiting reactor vessel beltline materials.
The results of these additional calculations are provided in the enclosure.
If you have any questions, please contact Fred Polaski, Manager License Renewal, at 610-765-5935.
I declare under penalty of perjury that the foregoing is true and correct.
Respectfully, Executed on 05 /15'-0O Michael P. Gallagher I
Vice President, License Renewal AmerGen Energy Company, LLC A41 17
U.S. Nuclear Regulatory Commission May 15, 2006 Page 2 of 2
Enclosure:
Upper Shelf Energy Equivalent Margin Analysis Results For Non-limiting Reactor Vessel Beltline Materials.
cc:
Regional Administrator, USNRC Region I, w/o Enclosure USNRC Project Manager, NRR - License Renewal, Safety, w/Enclosure USNRC Project Manager, NRR - License Renewal, Environmental, w/o Enclosure USNRC Project Manager, NRR - OCGS, w/o Enclosure USNRC Senior Resident Inspector, OCGS, w/o Enclosure Bureau of Nuclear Engineering, NJDEP, w/Enclosure File No. 05040
Enclosure Page 1 of 10 Enclosure Upper Shelf Energy Equivalent Margin Analysis Results For Non-limiting Reactor Vessel Beltline Materials
Enclosure Page 2 of 10 OCGS RPV Plate Equivalent Margin Analysis R/2 PLATE (OCGS Plate Number 564-03A)
(OCGS Code Number G-8-7)
Surveillance Plate USE:
%Cu =
0.17 Capsule Fluence =
0.746x1018 n/cm2 Measured % Decrease =
0.6 (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
14 (R.G. 1.99, Figure 2)
Lower Intermediate Beltline Plate USE:
%Cu =
0.21 50 EFPY Peak ID Fluence =
6.97 x 1018 n/cm2 50 EFPY 1/4T Fluence =
4.39 x 101" n/cm2 R.G. 1.99 Predicted % Decrease =
24.8 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 24.8% s 29.5%, so plate is bounded by equivalent margin analysis.
Enclosure Page 3 of 10 OCGS RPV Plate Equivalent Margin Analysis BWR/2 PLATE (OCGS Plate Number 564-03B)
(OCGS Code Number G-8-8)
Surveillance Plate USE:
%Cu =
0.17 Capsule Fluence =
0.746x1018 n/cm2 Measured% Decrease =
0.6 (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
14 (R.G. 1.99, Figure 2)
Lower Intermediate Beltline Plate USE:
%Cu =
0.18 50 EFPY Peak ID Fluence =
6.97 x 1018 n/cm2 50 EFPY 1/4T Fluence =
4.39 x 1018 n/cm2 R.G. 1.99 Predicted % Decrease =
22.3 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 22.3% s 29.5%, so plate is bounded by equivalent margin analysis.
Enclosure Page 4 of 10 OCGS RPV Plate Equivalent Margin Analysis BWR/2 PLATE (OCGS Plate Number 564-03C)
(OCGS Code Number G-8-6)
Surveillance Plate USE:
%Cu Capsule Fluence
=
0.17
=
0.746x1018 n/cm2 Measured % Decrease =
0.6 (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
14 (R.G. 1.99, Figure 2)
Lower Intermediate Beltline Plate USE:
%Cu 50 EFPY Peak ID Fluence 50 EFPY 1/4T Fluence
=
0.20
=
6.97 x 1018 n/cm2
=
4.39 x 1018 n/cm2 R.G. 1.99 Predicted % Decrease =
24.0 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 24.0% 5 29.5%, so plate is bounded by equivalent margin analysis.
Enclosure Page 5 of 10 OCGS RPV Plate Equivalent Margin Analysis BWR/2 PLATE (OCGS Plate Number 564-03D)
(OCGS Code Number G-307-1)
Surveillance Plate USE:
%Cu =
0.17 Capsule Fluence =
0.746x1 018 n/cm2 Measured % Decrease =
0.6 (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
14 (R.G. 1.99, Figure 2)
Lower Beltline Plate USE:
%Cu =
0.17 50 EFPY Peak ID Fluence =
3.76 x 1018 n/cm2 50 EFPY 1/4T Fluence =
2.37 x 1 018 n/cm2 R.G. 1.99 Predicted % Decrease =
18.6 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 18.6% s 29.5%, so plate is bounded by equivalent margin analysis.
Enclosure Page 6 of 10 OCGS RPV Plate Equivalent Margin Analysis BWRU2 PLATE (OCGS Plate Number 564-03E)
(OCGS Code Number G-308-1)
Surveillance Plate USE:
%Cu =
0.17 Capsule Fluence =
0.746x1018 n/cm2 Measured% Decrease =
0.6 (CharpyCurves)
R.G. 1.99 Predicted % Decrease =
14 (R.G. 1.99, Figure 2)
Lower Beltline Plate USE:
%Cu =
0.17 50 EFPY Peak ID Fluence =
3.76 x 1018 n/cm2 50 EFPY 1/4T Fluence =
2.37 x 1018 n/cm2 R.G. 1.99 Predicted % Decrease =
18.6 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 18.6% s 29.5%, so plate is bounded by equivalent margin analysis.
Enclosure Page 7 of 10 OCGS RPV Plate Equivalent Margin Analysis BWR/2 PLATE (OCGS Plate Number 564-03F)
(OCGS Code Number G-307-5)
Surveillance Plate USE:
%Cu =
0.17 Capsule Fluence =
0.746x1 018 n/cm2 Measured % Decrease =
0.6 (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
14 (R.G. 1.99, Figure 2)
Lower Beltline Plate USE:
%Cu =
0.27 50 EFPY Peak ID Fluence =
3.76 x 1018 n/cm2 50 EFPY 1/4T Fluence =
2.37 x 1018 n/cm2 R.G. 1.99 Predicted % Decrease =
26.0 Adjusted % Decrease =
N/A (R.G. 1.99, Figure 2)
(R.G. 1.99, Position 2.2) 26.0% s 29.5%, so plate is bounded by equivalent margin analysis.
Enclosure Page 8 of 10 OCGS RPV Weld Equivalent Margin Analysis BWR/2 WELD. (OCGS Weld Numbers 2-564A, 2-564B, and 2-564C)
(OCGS Heat Number 86054B)
Surveillance Weld USE:
%Cu Capsule Fluence
=
0.28
=
0.746xl 018 n/cm2 Measured % Decrease =
Not reported (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
Not reported (R.G. 1.99, Figure 2)
Beltline Lower Intermediate Shell Axial Weld USE:
%Cu 50 EFPY Peak ID Fluence 50 EFPY 1/4T Fluence
=
0.206
=
6.16 x 1018 n/cm2
=
3.88 x 1018 n/CM2 R.G. 1.99 Predicted % Decrease =
28.6 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 28.6% s 39%, so weld is bounded by equivalent margin analysis.
Enclosure Page 9 of 10 OCGS Vessel RPV Welds Equivalent Margin Analysis BWR/2 WELD. (OCGS Weld Numbers 2-564D, 2-564E, and 2-564F)
(OCGS Heat Number 86054B)
Surveillance Weld USE:
%Cu =
0.28 Capsule Fluence =
0.746x1018 n/cm2 Measured % Decrease =
Not reported (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
Not reported (R.G. 1.99, Figure 2)
Beltline Lower Shell Axial Weld USE:
%Cu =
0.214 50 EFPY Peak ID Fluence =
3.71 x 10'8 n/cm2 50 EFPY 1/4T Fluence =
2.34 x 1018 n/cm2 R.G. 1.99 Predicted % Decrease =
25.5 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 25.5% s 39%, so weld is bounded by equivalent margin analysis.
Enclosure Page 10 of 10 OCGS Vessel RPV Weld Equivalent Margin Analyses BWR/2 WELD, (OCGS Weld Number 3-564)
(OCGS Heat Number 1248)
Surveillance Weld USE:
%Cu =
0.28 Capsule Fluence =
0.746x111 n/cm2 Measured % Decrease =
Not reported (Charpy Curves)
R.G. 1.99 Predicted % Decrease =
Not reported (R.G. 1.99, Figure 2)
Beltline Lower Shell to Lower Intermediate Shell Circumferential Weld USE:
%Cu =
0.214 50 EFPY Peak ID Fluence =
3.76 x 1018 n/cm2 50 EFPY 1/4T Fluence =
2.37 x 1018 n/cm2 R.G. 1.99 Predicted % Decrease =
25.0 (R.G. 1.99, Figure 2)
Adjusted % Decrease =
N/A (R.G. 1.99, Position 2.2) 25.0% s 39%, so weld is bounded by equivalent margin analysis.
Oyster Creek Document Distribution Sheet TITLE/
SUBJECT:
Supplemental Information for Responses to NRC RAI 4.2.2-1 Related to OCGS License Renewal Application (TAC No. MC7624)
COGNIZANT INDIVIDUAL: Fred Polasid SPECIAL HANDLING INSTRUCTIONS:
FILE STRUCTURE:
- - already distributed, CC'd E - Electronically Distributed X - Hard Copy OC VP & Direct Reports OC VP: T. Rausch SVP EA: V. Aggarwal Plant Manager: J. Randich Engineering: M. Button Maintenance: J. Magee Training: J. Vaccaro Reg Assurance: J. Kandasamy HR: H. Behrens Outage: W. Carter Rad Pro/Chem:
Work Management: C. Wilson AmerGen/Exelon VP L&RA: T. O'Neill Env. Dir Acting: S. Sklenar Environmental: S. Sklenar Licensing: P. Cowan Licensing: D. Helker Licensing: V. Gallimore KS Document Ctr.
KS Emerg. Prep: J. Karkoska OCAB-2 OCAB-2 MOB OCAB-3 NMB Bldg 12 OCAB-2 OCAB-2 OCAB-2 AOB OCAB-2 Cantera KS KS KSA3-E KSA 3-E KSA 3-E KSA 1-N KS E
E E
E E
E E
E x
Oyster Creek Operations: R. Racholski Operations: J. Dostal Operations/Rx Engg.: F. Buckley Work Control: P. Bloss Radiation Protection: J. Renda Env/Chemistry: C. Connelly Security: K. Dreher Engineering: J. O'Rourke I&C/NSSS: J. Frank BOP Engineering: J. Camire Eng. Programs: R Skelskey Mech/Str Design: H. Ray E/I&C Des: D. Barnes Maintenance: R Laning Communications: R. Benson NOS: D. Peiffer Emerg Prep: K. Poletti Lic. Renewal: T. E. Quintenz Chem/Env Dept Files Reg Assurance Dept Files Other K. Barnes C. Duffy Guy DeBoo J. Hoddy MOB MOB OCAB-3 MOB AOB AOB OCAB-2 OCAB-3 OCAB-3 OCAB-3 OCAB-3 OCAB-3 OCAB-3 NMB OCAB-2 OCAB-2 OCAB-2 AOB E
E E
E 05040 E
External Distribution NJBNE - P. Baldauf NSRB x
OCAB-2 OCAB-2 Cantera KSA2-E KSA2-E E
E E
E E
M. Guthrie STANDARD FILE CODE /
RECORD RECORD RECORDSNUBRRCRNMEDT RETENTION (REFERENCE #)
NUMBER RECORD NAME DATE SCHEDULE #
2130-06-20332 Supplemental Information for 5115106 Responses to NRC RAI 4.2.2-1. Non-5//0 limiting Reactor Vessel Beltline Materials