Other: ML052690388, ML052850300, ML053250326, ML053410352, ML053410369, ML053410372, ML053420167, ML053460234, ML053470213, ML053470434, ML053500440, ML053540079, ML060200084, ML060320211, ML060370508, ML060410649, ML060600122, ML060660177, ML060690026, ML060690130, ML060830564, ML060830567, ML060870126, ML060870147, ML060890080, ML060930255, ML060940146, ML060950408, ML060960563, ML060960568, ML060960602, ML061010639, ML061010644, ML061010646, ML061020614, ML061020616, ML061020638, ML061030419, ML061070304, ML061070306, ML061070307, ML061070309, ML061070310, ML061070319, ML061070321, ML061070329, ML061070395, ML061070398, ML061070399, ML061070403... further results
|
MONTHYEARML0726804681954-12-31031 December 1954 New Jersey Department of Environmental Protection, Division of Parks and Forestry, State Forest Service, New Jerseys Big Trees Project stage: Other ML0726705561963-01-31031 January 1963 Us Fish and Wildlife Service, 1963. Distribution of Shellfish Resources in Relation to the New Jersey Intracoastal Waterway -- Manasquan Inlet to Little Egg Harbor. Boston, Ma. January Project stage: Other ML0726405941972-11-17017 November 1972 Jersey Central Power & Light Company, Oyster Creek Nuclear Generating Station Environmental Report, Amendment 2 Project stage: Other ML0726406651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration Project stage: Other ML0726703621978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Initial Progress Report, December 1966, Through Third Progress Report, January 1968 Project stage: Other ML0726703651978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Fourth Progress Report 1968 Through Sixth Progress Report 1970, Concluding Remarks Project stage: Other ML0726703681978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Seventh Progress Report, June 25, 1971, Through Eighth Progress Report, August 18, 1972 Project stage: Other ML0726703741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Zooplankton of Barnegat Bay: the Effect of Oyster Creek Nuclear Power Plant Through Literature Cited Project stage: Other ML0726704911978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix E Through Appendix F, Figure 10 Project stage: Other ML0726705501978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix a Through Appendix C1, Figure C1-1 Project stage: Other ML0726801491978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Addendum to Appendix C1 Through Addendum to Appendix D1 Project stage: Other ML0726801691978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Preface Through Table 6.2-2 Project stage: Other ML0726801741978-12-31031 December 1978 Jersey Central Power & Light Company. 1978. Oyster Creek and Forked River Nuclear Generating Stations 316(a) and (B) Demonstration, Appendix C Continued Page C2-1 Through Page C6-51 Project stage: Other ML0726802291979-10-22022 October 1979 Letter from David N. Kinsey (New Jersey Department of Environmental Protection) Dated October 22, 1979 to Ivan R. Finfrock (Jersey Central Power & Light Company), NPDES Permit Renewal Application No. NJ0005550 Project stage: Other ML0726405991982-05-14014 May 1982 Jersey Central Power & Light Co. Boundary Map of Former Finninger Farm Project stage: Other ML0726705601986-12-12012 December 1986 Inventory of New Jerseys Estuarine Shellfish Resources, Joseph, J. W., Us Department of Commerce National Oceanic and Atmospheric Administration, National Marine Fisheries Service, December 12, 1986 Project stage: Other ML0726801891987-12-0909 December 1987 Joseph, J. W. 1987, Inventory of New Jerseys Estuarine Shellfish Resources, Us Department of Commerce National Oceanic and Atmospheric Administration National Marine Fisheries Service. Project No. 3-405-R Project stage: Other ML0726703911989-12-31031 December 1989 Lacey Township, Ocean County, New Jersey. 1989. Ocean County Water Quality Management Plan, Wastewater Management Plan Project stage: Other ML0726704221989-12-31031 December 1989 Usda. 1989. Soil Survey of Ocean County, New Jersey. Sheet Number 45 Project stage: Other ML0610206381990-11-26026 November 1990 Drywell Containment, Attachment 1 to Letter Dated 04/07/2006 Project stage: Other ML0610206141991-03-0404 March 1991 Letter Forwarding, an ASME Section Viii Evaluation of Oyster Greek Drywell for Without Sand Case Part 1 Stress Analysis, Attachment 2 to Letter Dated 04/07/06 Project stage: Other ML0610206161992-01-16016 January 1992 Letter Forwarding, ASME Section Viii Evaluation of the Oyster Creek Drywell, Part 2, Stability Analysis, Attachment 3 to Letter Dated 04/07/2006 Project stage: Other ML0702906681992-04-24024 April 1992 Evaluation Report on Structural Integrity of the Oyster Creek Drywell with Brookhaven National Laboratory Technical Evaluation Report - Attached Project stage: Other ML0726801841997-02-0404 February 1997 State of New Jersey Permit No. 1512-93-0052.3, .4, and .5, Permit to Dredge Project stage: Other ML0726804281997-09-30030 September 1997 Department of the Army, Corps of Engineers, Permit Number CENAP-OP-R-199701765-39 Project stage: Other ML0726704171997-10-31031 October 1997 State of New Jersey Department of Environmental Protection. the Management and Regulation of Dredging Activities and Dredged Material Disposal in New Jerseys Tidal Waters. October 1997 Project stage: Other ML0726703842000-04-25025 April 2000 Levin, S. 2000. Letter, Levin (Gpu Nuclear Inc.) to New Jersey Department of Environmental Protection. Application for Transfer of Ownership and of a Permit Project stage: Request ML0726804482002-05-15015 May 2002 New Jersey Department of Environmental Protection. 2002. List of State Flood Hazard Area Delineations. May 15 Project stage: Other ML0726803802003-05-15015 May 2003 Shellfish Stock Assessment of Little Egg Harbor Bay (Dsrt Proposal 2001011), Celestino, M. P., New Jersey Department of Environmental Protection, 15 May 2003 Project stage: Other ML0726803592003-12-31031 December 2003 Private Property and the Common Good, Anonymous, 2003, Powerpoint Presentation Project stage: Other ML0726704012004-01-31031 January 2004 Energy Information Administration. 2004. State Energy Profiles 2002. January. (Excerpt). Us Department of Energy Project stage: Other ML0726802382004-02-28028 February 2004 Clean, Safe, Reliable, the Economic Benefits of Oyster Creek Generating Station, February 2004 Project stage: Other ML0726804052004-07-0707 July 2004 Ecolsciences, Inc., 2004, Threatened and Endangered Species Habitat Impact Assessment for Oyster Greek Generation Station National Security Upgrades; Township of Lacey; Ocean County, New Jersey, Prepared for Amergen Energy Co., LLC Project stage: Other ML0726704042004-12-31031 December 2004 Energy Information Administration. 2004. State Energy Data 2002: Consumption. Table 7 Energy Consumption Estimates by Source, Selected Years, 160-2002, New Jersey. Us Department of Energy Project stage: Other ML0726705522004-12-31031 December 2004 New Jersey Department of Environmental Protection, 2004 Cafra Boundary Line Project stage: Other ML0726804182004-12-31031 December 2004 Energy Information Administration, 2004, Existing Generating Units in the United States by State, Company, and Plant, 2004, Us Department of Energy Project stage: Other ML0726703942005-07-19019 July 2005 Tompkins, H.B. 2005. Letter Tompkins (State of New Jersey, Department of Environmental Protection) to Brown (Amergen). Draft Surface Water Renewal Permit Action. Includes Public Notice, Fact Sheet, and Draft NJPDES Permit Project stage: Draft Other ML0726808302005-07-19019 July 2005 Ocean County Soil Conservation District, 2005, Soil Erosion and Sedimentation Control Certification; Upland Dredge Site, Scd 1302 Project stage: Other ML0520800482005-07-22022 July 2005 Application for Renewed Operating License Project stage: Request ML0726802022005-07-25025 July 2005 FEMA Floodzone Map for Lacey Township, Ocean County, Nj, Provided by Birdsall Engineering, Inc Project stage: Other ML0526903882005-09-23023 September 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station Project stage: Other ML0527101572005-09-28028 September 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0528503002005-10-0505 October 2005 Audit and Review Plan for Plant Aging Management Reviews and Programs at the Oyster Creek Generating Station (Tac No. MC7624) Project stage: Other ML0529100912005-10-12012 October 2005 Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application (Tac No. MC7624) Project stage: Response to RAI ML0610703042005-10-21021 October 2005 Email: Pictures? (PA) Project stage: Other ML0610703062005-11-0404 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0610703072005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0531400422005-11-0909 November 2005 Request for Additional Information for the Review of the Oyster Creek Nuclear Generating Station, License Renewal Application (Tac No. MC7624) Project stage: RAI ML0610703092005-11-0909 November 2005 Email: Emailing: Example NPDES Report.Pdf (PA) Project stage: Other ML0532004752005-11-11011 November 2005 Supplemental Response to NRC Request for Additional Information (RAI 2.5.1.19-1), Dated September 28, 2005, Related to Oyster Creek Generating Station License Renewal Application Project stage: Supplement 2002-05-15
[Table View] |
Text
AmerGen SM AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348 www.exeloncorp.corn An Exelon Company 10 CFR 50 10 CFR 51 10 CFR 54 2130-06-20278 March 2, 2006 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility Operating License No. DPR-16 NRC Docket No. 50-219
Subject:
Reference:
Correction of Minor Errors in the Oyster Creek Generating Station License Renewal Application (TAC No. MC7624)
(1) "Application for Renewed Operating License," Oyster Creek Generating Station, dated July 22, 2005.
During the ongoing review of the Oyster Creek License Renewal Application by the NRC, AmerGen has identified a number of errors that we believe are minor and do not substantively affect the LRA. However, in order to be as complete and accurate as possible we are providing the attached tabulation summarizing them.
If you have any questions, please contact Fred Polaski, Manager License Renewal, at 610-765-5935.
I declare under penalty of perjury that the foregoing is true and correct.
Respectfully, Executed on 03 loz.
?xoo Michael P. Gallagher Vice President, License Renewal AmerGen Energy Company, LLC
Enclosure:
Summary of LRA Minor Text Errors 4U'A q
U.S. Nuclear Regulatory Commission March 2, 2006 Page 2 cc:
Regional Administrator, USNRC Region 1, w/o Enclosure USNRC Project Manager, NRR - License Renewal, Safety USNRC Project Manager, NRR - License Renewal, Environmental, w/o Enclosure USNRC Project Manager, NRR - Project Manager, Oyster Creek USNRC Senior Resident Inspector, Oyster Creek, w/o Enclosure Bureau of Nuclear Engineering, New Jersey Department of Environmental Protection File No. 05040
Enclosure Summary ol Minor Text Errors Oyster Creekc Generating Station License Renewal Application (TAC No. MC7624)
Section 2.3.2.3 Section 2.3.3.11 Section 3.1.2.2.11 and Table 3.1.1 Section 3.3.2.1.15 Subsection 3.3.2.2.7.3 Subsection 3.3.2.2.13 Section 3.6.2.3.1 Table 2.3.4.2 Table 3.3.2.1.18 Table 3.3.2.1.29 Table 2.5.2 Table 3.5.1 1 of 3
Section 2.3.2.3 License Renewal Boundary Drawing LR-GE-885D781 was incorrectly listed as LR-855D78 1.
This typographical error has no impact on the LRA.
Section 2.3.3.11 The Containment Spray Heat Exchanger Hoists were inadvertently omitted from the text of this section. These hoists are in the scope of License Renewal and are subject to the aging management programs as are the hoists listed. This error has no impact on the LRA beyond the omission from the text of Section 2.3.3.11.
Section 3.1.2.2.11 and Table 3.1.1 In Section 3.1.2.2.11 and Table 3.1.1, item 3.1.1-20, BWRVIP-135 was incorrectly referenced as BWRVIP-139. This typographical error has no impact on the LRA.
Section 3.3.2.1.15 Under the Materials heading "Alumina Silicate" was incorrectly spelled "Aluminum Silicate."
This typographical error has no impact on the LRA.
Subsection 3.3.2.2.7.3 Specific identification of the Hardened Vlent System, Spent Fuel Cooling System, and Water Treatment and Distribution System was inadvertently omitted from the discussion. This change does not affect the LRA Chapter 3 aging management evaluations or the One-Time Inspection Program since these systems were included in the program. This error has no impact on the LRA beyond the omission from the text of Subsection 3.3.2.2.7.3.
Subsection 3.3.2.2.13 Subsection 3.3.2.2.13 states, "Periodic inspections are performed on elastomer door seals to identify detrimental changes in material properties, as evidenced by cracking, perforations in the material, or leakage." It should state, "Periodic inspections are performed on elastomer door seals to identify loss of material due to wear" to correctly reflect the aging effect/mechanism listed in Table 3.3.1, Summary of aging Management Evaluations for the Auxiliary Systems, for item number 3.3.1-28, "Elastomer seals and components exposed to air - indoor uncontrolled." This error has no impact on the LRA since the correct aging effect/mechanism was recognized (Table 3.3.1).
Section 3.6.2.3.1 The reference to "SAND 0944" is a typographical error; it should read "SAND96-0344". This error has no impact on the LRA.
Table 2.3.4.2 "Filter" and "Filter Housing" are included in Table 3.4.2.1.2 along with the appropriate information for each. These two Component Types were inadvertently omitted from summary Table 2.3.4.2. This error has no impact on the LRA.
Table 3.3.2.1.18 In Section 3.3, Table 3.3.1, Item 3.3.1-23 and associated LRA section 3.3.2.2.10.2 state that a One-Time Inspection program will be implemented to verify the effectiveness of the Water Chemistry program to manage the loss of material in copper alloy piping, piping components, and piping elements exposed to a treated water internal environment in the Heating & Process Steam System. For Component Types: Steam Trap, Valve Body, and Heat Exchanger; Intended Function: Leakage Boundary; Material: Copper/Copper Alloy; Environment: Boiler Treated Water/Auxiliary Steam (Internal); and Aging Effect Requiring Management: Loss of Material; 2 of 3
LRA Table 3.3.2.1.18 lists the One-Time Inspection program, but the Water Chemistry program was inadvertently omitted as an applicable Aging Management Program. This error has no impact on the LRA.
Table 3.3.2.1.29 The Heat Exchangers (Augmented Fuel Pool Cooling) in the Reactor Building Closed Cooling Water System have both stainless steel and carbon steel carrying bars that perform the structural support intended function. The words "Stainless Steel (Carrying Bars)" and "Indoor Air (External)" were inadvertently deleted fiom Table 3.3.2.1.29. However, the Associated Aging Effect Requiring Management, Aging Management Programs, NUREG-1801 Vol. 2 Item, Table I Item, and Notes fields were correctly populated. This error has no impact on the LRA beyond the omission of these entries in the two cells of the table.
Table 2.5.2 Transformers were inadvertently omitted from LRA Table 2.5.2. This omission was the result of a transcription error. Since transformers are defined as active components in NUREG 1800, they are screened out from further Aging Management Review and subsequent Aging Management Programs. Consequently, this error has no impact on the LRA beyond the omission from Table 2.5.2.
Table 3.5.1 The following text was inadvertently omitted from the Discussion for Item Number 3.5.1-21, "Cranes and hoists rollup into this item. For these components the Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems program is the applicable aging management program for the component instead of Structures Monitoring Program".
3 of 3