Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML20217G7211999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Waterford 3 Ses. with ML20211Q2141999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Waterord 3 Ses.With ML20210Q6361999-07-31031 July 1999 Corrected Monthly Operating Rept for July 1999 for Waterford 3 ML20210S0581999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Waterford 3.With ML20209H3781999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Waterford 3 Ses. with ML20195K3391999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Waterford 3 Ses.With ML20206S7401999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Waterford 3.With ML20205N9671999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Waterford 3 Ses.With ML20204B5141999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Waterford 3.With ML20199C9101998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Waterford 3.With ML20206N4131998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Waterford 3.With ML20195E5161998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Waterford 3.With ML20154K0801998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Waterford 3 Ses. with ML20151W8331998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Waterford,Unit 3. with ML20237B5261998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Waterford 3 ML20236N4181998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Waterford,Unit 3 ML20249A4711998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Waterford 3 Ses ML20247F6761998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Waterford,Unit 3.W/ ML20216B1751998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Waterford 3 Ses ML20248L3621998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Waterford 3 ML20202G5091998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Waterford,Unit 3 ML20198M2301997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Waterford 3 Ses ML20203F9701997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for Waterford 3 Ses ML20199B3491997-10-31031 October 1997 Monthly Operating Rept for Oct 1997 for Waterford 3 Ses ML20217H9481997-09-30030 September 1997 Monthly Operating Rept for Sept 1997 for Waterford 3 Ses ML20210T5421997-08-31031 August 1997 Monthly Operating Rept for Aug 1997 for Waterford 3 ML20210J3541997-07-31031 July 1997 Monthly Operating Rept for Jul 1997 for Waterford 3 ML20148K1691997-05-31031 May 1997 Monthly Operating Rept for May 1997 for Waterford ML20141C8751997-04-30030 April 1997 Monthly Operating Rept for April 1997 for Wgs ML20137U7861997-03-31031 March 1997 Monthly Operating Rept for Mar 1997 for Waterford 3 Ses ML20136H2661997-02-28028 February 1997 Monthly Operating Rept for Feb 1997 for Waterford 3 ML20138K5841997-01-31031 January 1997 Monthly Operating Rept for Jan 1997 for Waterford 3 Ses ML20133L9151996-12-31031 December 1996 Monthly Operating Rept for Dec 1996 for Waterford 3 Ses ML20132B9441996-11-30030 November 1996 Monthly Operating Rept for Nov 1996 for Waterford 3 Ses ML20134K5441996-10-31031 October 1996 Monthly Operating Rept for Oct 1996 for Waterford 3 Ses ML20128P9921996-09-30030 September 1996 Monthly Operating Rept for Sept 1996 for Waterford 3 Ses ML20129A6851996-08-31031 August 1996 Monthly Operating Rept for Waterford 3 Ses for Aug 1996 ML20116L0431996-07-31031 July 1996 Monthly Operating Rept for Jul 1996 for Waterford 3 ML20115F0421996-06-30030 June 1996 Monthly Operating Rept for June 1996 for Waterford 3 ML20117M9471996-05-31031 May 1996 Monthly Operating Rept for May 1996 for Waterford 3 ML20117F6991996-04-30030 April 1996 Monthly Operating Rept for Apr 1996 for Waterford Unit 3.W/ ML20107B9071996-03-31031 March 1996 Monthly Operating Rept for Mar 1996 for Wateford 3 Ses.W/ ML20106H0741996-02-29029 February 1996 Monthly Operating Rept for Feb 1996 for Waterford 3 Ses ML20097G0771996-01-31031 January 1996 Monthly Operating Rept for Jan 1996 for Waterford 3 Ses ML20096C2761995-12-31031 December 1995 Monthly Operating Rept for Dec 1995 for Waterford 3 Ses.W/ ML20095E6151995-11-30030 November 1995 Monthly Operating Rept for Nov 1995 for Waterford 3 Ses ML20094L0261995-10-31031 October 1995 Monthly Operating Rept for Oct 1995 for Waterford 3 ML20093D1731995-09-30030 September 1995 Monthly Operating Rept for Sept 1995 for Waterford 3 ML20092D0181995-08-31031 August 1995 Monthly Operating Rept for Aug 1995 for Waterford 3 ML20087H1001995-07-31031 July 1995 Monthly Operating Rept for July 1995 for Waterford 3 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217F2891999-10-13013 October 1999 Drill 99-08 Emergency Preparedness Exercise on 991013 05000382/LER-1999-014, :on 990910,reactor Shutdown Due to Loss of Controlled bleed-off Flow,Occurred.Caused by Rotating Baffle failure.Two-piece Rotating Baffle of Original Design Was Located & Installed,In Order to Repair RCP 2B1999-10-12012 October 1999
- on 990910,reactor Shutdown Due to Loss of Controlled bleed-off Flow,Occurred.Caused by Rotating Baffle failure.Two-piece Rotating Baffle of Original Design Was Located & Installed,In Order to Repair RCP 2B
ML20217G7211999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Waterford 3 Ses. with 05000382/LER-1999-013, :on 990825,exceeding TS Limits for RCS Cooldown Rate Was Discovered.Caused by Inadequate Content & Inadequate Implementation of TS Requirements.Page 2 of 2 in Attachment 2 of Incoming Submittal Not Included1999-09-23023 September 1999
- on 990825,exceeding TS Limits for RCS Cooldown Rate Was Discovered.Caused by Inadequate Content & Inadequate Implementation of TS Requirements.Page 2 of 2 in Attachment 2 of Incoming Submittal Not Included
05000382/LER-1999-012-01, :on 990812,potential Operation with Both Control Room Normal Outside Air Intakes Valves Inoperable Occurred.Cause for Event Was Indeterminate.Seat Leakage Requirements Calculated.With1999-09-13013 September 1999
- on 990812,potential Operation with Both Control Room Normal Outside Air Intakes Valves Inoperable Occurred.Cause for Event Was Indeterminate.Seat Leakage Requirements Calculated.With
ML20211Q2141999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Waterord 3 Ses.With 05000382/LER-1999-011-01, :on 990801,with Plant Operating 100% Power, Lowering RCP Seal Pressures,Along with Dropping Controlled bleed-off (Cbo) & Increasing Cbo Temp Discovered.Caused by fatigue-induced Failure of Rotating Baffle of RCP 2B1999-08-31031 August 1999
- on 990801,with Plant Operating 100% Power, Lowering RCP Seal Pressures,Along with Dropping Controlled bleed-off (Cbo) & Increasing Cbo Temp Discovered.Caused by fatigue-induced Failure of Rotating Baffle of RCP 2B
05000382/LER-1999-010-01, :on 990726,discovered Inadequate Pumping Capacity in Dry Cooling Tower Area.Caused by Inadequate Design Control.Portable Pumps Were Installed in Each Dry Cooling Tower Areas to Ensure Sufficient Pumping Capacity1999-08-26026 August 1999
- on 990726,discovered Inadequate Pumping Capacity in Dry Cooling Tower Area.Caused by Inadequate Design Control.Portable Pumps Were Installed in Each Dry Cooling Tower Areas to Ensure Sufficient Pumping Capacity
05000382/LER-1999-009-01, :on 990727,discovered App R Noncompliance Condition Involving Inadequate Separation of Safe Shutdown Cables.Caused Design Analysis Deficiency.Compensatory Measures Were Established1999-08-26026 August 1999
- on 990727,discovered App R Noncompliance Condition Involving Inadequate Separation of Safe Shutdown Cables.Caused Design Analysis Deficiency.Compensatory Measures Were Established
ML20210Q6361999-07-31031 July 1999 Corrected Monthly Operating Rept for July 1999 for Waterford 3 ML20210S0581999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Waterford 3.With 05000382/LER-1999-008-01, :on 990629,failure to Perform Testing of ESF Filtration Units Per TS Was Noted.Cause for Testing Charcoal Samples Contrary to TS Could Not Be Determined.All Future Analysis Will Be Performed IAW ASTM D3803-1989,per GL 99-021999-07-29029 July 1999
- on 990629,failure to Perform Testing of ESF Filtration Units Per TS Was Noted.Cause for Testing Charcoal Samples Contrary to TS Could Not Be Determined.All Future Analysis Will Be Performed IAW ASTM D3803-1989,per GL 99-02
05000382/LER-1999-007-01, :on 990625,operation Outside Tornado Missile Protection Licensing Basis for turbine-driven EFW Pump & Steam Supply Piping,Was Discovered.Caused Indeterminent. Entergy Will Submit 10CFR50.90 to NRC Staff1999-07-23023 July 1999
- on 990625,operation Outside Tornado Missile Protection Licensing Basis for turbine-driven EFW Pump & Steam Supply Piping,Was Discovered.Caused Indeterminent. Entergy Will Submit 10CFR50.90 to NRC Staff
ML20210D8951999-07-23023 July 1999 Safety Evaluation Accepting First 10-yr Interval Inservice Insp Plan Requests for Relief ISI-018 - ISI-020 05000382/LER-1999-006-01, :on 990614,plant Experienced Automatic Reactor Trip Following Loss of 7kV Bus.Caused by Spurious Actuation of Relay on Either RCP 1A or 2A.Personnel Performed Final Switchgear Walkdown with Indications Normal.With1999-07-14014 July 1999
- on 990614,plant Experienced Automatic Reactor Trip Following Loss of 7kV Bus.Caused by Spurious Actuation of Relay on Either RCP 1A or 2A.Personnel Performed Final Switchgear Walkdown with Indications Normal.With
ML20209H3781999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Waterford 3 Ses. with 05000382/LER-1999-005-01, :on 980702,determined That Four Contacts in Control Circuits of EFW Control Valves Were Untested.Caused by Personnel Error.Untested Contacts Have Been Tested1999-06-24024 June 1999
- on 980702,determined That Four Contacts in Control Circuits of EFW Control Valves Were Untested.Caused by Personnel Error.Untested Contacts Have Been Tested
ML20195J8951999-06-17017 June 1999 Safety Evaluation Granting Relief for Listed ISI Parts for Current Interval,Per 10CFR50.55a(g)(5)(iii) ML20195J9741999-06-16016 June 1999 Safety Evaluation Supporting Amend 152 to License NPF-38 ML20207E8631999-06-0303 June 1999 Safety Evaluation Accepting Licensee 990114 Submittal of one-time Request for Relief from ASME B&PV Code IST Requirements for Pressure Safety Valves at Plant,Unit 3 ML20195D5491999-06-0303 June 1999 Safety Evaluation Supporting Amend 151 to License NPF-38 ML20195K3391999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Waterford 3 Ses.With ML20195C3041999-05-28028 May 1999 Annual Rept on ABB CE ECCS Performance Evaluation Models 05000382/LER-1999-004-02, :on 990415,discovered That Complete Response Time for ESFAS Containment Cooling Function Had Not Been Performed.Caused by Response Time Testing Deficiency. Procedures Will Be Revised to Include Subject Testing1999-05-14014 May 1999
- on 990415,discovered That Complete Response Time for ESFAS Containment Cooling Function Had Not Been Performed.Caused by Response Time Testing Deficiency. Procedures Will Be Revised to Include Subject Testing
ML20206S7401999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Waterford 3.With ML20205T2621999-04-22022 April 1999 LER 99-S02-00:on 990216,contract Employee Inappropriately Granted Unescorted Access to Plant Protected Area.Caused by Personnel Error.Security Personnel Performed Review of Work & Work Area That Individual Was Involved with ML20206A9641999-04-21021 April 1999 Safety Evaluation Supporting Amend 150 to License NPF-38 05000382/LER-1999-003-02, :on 990311,determined That Four Containment Vacuum Relief valves,CVR-101,CVR-201,CVR-102 & CVR-202,were Not Tested.Caused by Contractor Supply of Misinformation. Details of Event Discussed with Contractor.With1999-04-0909 April 1999
- on 990311,determined That Four Containment Vacuum Relief valves,CVR-101,CVR-201,CVR-102 & CVR-202,were Not Tested.Caused by Contractor Supply of Misinformation. Details of Event Discussed with Contractor.With
ML20205N9671999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Waterford 3 Ses.With ML20205E8531999-03-30030 March 1999 Corrected Pages COLR 3/4 1-4 & COLR 3/4 2-6 to Rev 1, Cycle 10, Colr ML20205A6331999-03-25025 March 1999 SER Accepting Request to Use Mechanical Nozzle Seal Assemblies as an Alternative Repair Method,Per 10CFR50.55a(a)(3)(i) for Reactor Coolant Sys Applications at Plant,Unit 3 05000382/LER-1999-002-03, :on 990225,discovered RCS Pressure Boundary Leakage on Two Inconel 600 Instrument Nozzles.Caused by Axial Cracks Near HAZ of Nozzle Partial Penetration Welds Resulting from Pwscc.Leaking Nozzles Have Been Repaired1999-03-25025 March 1999
- on 990225,discovered RCS Pressure Boundary Leakage on Two Inconel 600 Instrument Nozzles.Caused by Axial Cracks Near HAZ of Nozzle Partial Penetration Welds Resulting from Pwscc.Leaking Nozzles Have Been Repaired
ML20204H1401999-03-23023 March 1999 Rev 1 to Engineering Rept C-NOME-ER-0120, Design Evaluation of Various Applications at Waterford Unit 3 ML20204H1231999-03-22022 March 1999 Rev 1 to Design Rept C-PENG-DR-006, Addendum to Cenc Rept 1444 Analytical Rept for Waterford Unit 3 Piping ML20204H2451999-03-22022 March 1999 Rev 2 to C-NOME-SP-0067, Design Specification for Mechanical Nozzle Seal Assembly (Mnsa) Waterford Unit 3 ML20204F0791999-03-17017 March 1999 Rev 1 to Waterford 3 COLR for Cycle 10 ML20207M9231999-03-12012 March 1999 Amended Part 21 Rept Re Cooper-Bessemer Ksv EDG Power Piston Failure.Total of 198 or More Pistons Have Been Measured at Seven Different Sites.All Potentially Defective Pistons Have Been Removed from Svc Based on Encl Results ML20207F3491999-03-0505 March 1999 LER 99-S01-00:on 990203,contraband Was Discovered in Plant Protected Area.Bottle Was Determined to Have Been There Since Original Plant Construction.Bottle Was Removed & Security Personnel Performed Search of Area.With ML20204B5141999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Waterford 3.With ML20203H8151999-02-17017 February 1999 Safety Evaluation Supporting Amend 149 to License NPF-38 ML20203H8591999-02-17017 February 1999 Safety Evaluation Accepting Licensee Second Ten Year ISI Program & Associated Relief Requests for Plant,Unit 3 05000382/LER-1999-001, :on 990105,TS 3.0.3 Was Entered.Caused by Less than Adequate Chiller Thermostat Control.Placed Tamper Seal on Chiller Thermostat.With1999-02-0404 February 1999
- on 990105,TS 3.0.3 Was Entered.Caused by Less than Adequate Chiller Thermostat Control.Placed Tamper Seal on Chiller Thermostat.With
ML20202H9161999-02-0202 February 1999 Safety Evaluation Supporting Amend 148 to License NPF-38 ML20199H6261999-01-21021 January 1999 Safety Evaluation Accepting Classification of Instrument Air Tubing & Components for Safety Related Valve Top Works.Staff Recommends That EOI Revise Licensing Basis to Permit Incorporation of Change 05000382/LER-1998-020, :on 981204,determined That Certain Core Power Distribution SRs Had Been Incorrectly Scheduled.Caused by TS Change Implementation Error.Will Perform Final Review of TS SRs with 4.0.4 Exemption.With1998-12-31031 December 1998
- on 981204,determined That Certain Core Power Distribution SRs Had Been Incorrectly Scheduled.Caused by TS Change Implementation Error.Will Perform Final Review of TS SRs with 4.0.4 Exemption.With
ML20199C9101998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Waterford 3.With ML20198F4691998-12-21021 December 1998 Safety Evaluation Supporting Amend 147 to License NPF-38 ML20196F4911998-12-0101 December 1998 SER Accepting Request for Relief ISI2-09 for Waterford Steam Electric Station,Unit 3 & Arkansas Nuclear One,Unit 2 ML20206N4131998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Waterford 3.With ML20195C4841998-11-0606 November 1998 SER Accepting QA Program Change to Consolidate Four Existing QA Programs for Arkansas Nuclear One,Grand Gulf Nuclear Station,River Bend Station & Waterford 3 Steam Electric Station Into Single QA Program 1999-09-30
[Table view] |
Text
- s
<Y . ,, 'e "
t l
l' i- Louisiana POWER & LIGHT/ sir.Anouwt$1acc1 . n. o. 0x .o ,.0 NEW ORLEANS, tOUISlANA 70160 + (504) $953100
. 50idIv6NU W3P89-1598 A4.05 QA ,
I October 16, 1989 f i
U.S. Nuclear Regulatory Commission ;
ATTN Document Control Desk i Washington, D.C. 20555 l
Subject:
Waterford 3 SES !
Docket No. 50-382 I License No. NPT-38 i MONTHLY OPERATING REPORT l
Gentlemen:
Enclosed is the subject monthly report which covers the operating I statistics for the month of September, 1989. This report is submitted per l Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility !
m ,. Operating License No. NPF-38.
{
Very truly yours, ;
.R.F. Burski j Manager l
Nuclear Safety & Regulatory Affafre i i
RFB/LWL/0PP/pi !
Enclosure i ect R.D. Martin, NRC Region IV F.J. Hebdon, NRC-NRR INPO Rucords Center (J.T. Wheelock)
NRC Resident Inspectors Office ,;
E.L. Blake :
W.M. Stevenson l t
hk I 9910250038 890930 P 1
'l PDR ADOCK 05000382 I R PNV i I
l "AN EOUAL OPPORTUNITY EMPLOYER" )
l
pc m. 5, . m. 4
,e ij .' w' '. .n. , ,
. ,' ,'e . /, %, ; ,9 ) 4 - ' 'y..
.9 ,
. c.
y ' ,((
o i
. c. . ,/~
,e 3 , ,
.j c , w ,
4 d
9 N \, e: . <. ,
NRC MONTHLY OPERATING REPORT' !O 4- ,o 4.
4 1
' ir s,. 4 .
SUMMARY
OF OPERATIONS' .. .
WATERFORD 3
= SEPTEMBER'1989' t
>Y+ l 4
i The unit operated at sa average reactor power of.73.1% and commenced Refuel Octage 3 during the period. >
1 4
' ~
y>
<r e
i.
t 6
<k i 4
)'
'j . ,
- .9 . i p%t, - ;.
!,,{.. ,
L ,
I l
Y.,,... ' W310204B
,i .
6
1
' .L > Ty"X -
t ff .,n. ,
( ' , ., t s
.3.. ., " g'.):r.j ti> '
... s *c J , . a
'e..j_yf%.s. . \. '_ ? . y ' J_El ' Ol N { ,
, , ., .. y.
..)
,,s . ,4
].(e.
.. . .[.s..y,
)
I.
, . w* < a 1
'j+r. 1 a,..-,.". .
(.
< y a .4. ,
' *lf ;' ;-) ..
g
- s. .
t 1
]; ,.' '> $ , ,
, , i
- .C ,
PRE 88URIZER SAFETY VALVE ~- i
, , 1 c '. FAILURES AND CHALLENGES 4
~
. WATERFORD 3 4
.,.. .I .
k i ,,6 '
,Jp , During,the month.'of September 1989, there were no pressuriser safety valve -
failures or challenges. '
,p .
.c i ,
"). ;
5 a i
w 1 v , .
.I5
'E ' k.
s
', }
k . . I:
\.
1 Y
h
'6
+
k
.W310204B
,4
. ,,s..
2
'b w
v 6 J ,
'l k ,
.;, 7 OPERATING DATA REPORT
.g ' '. , ,
Q o b' '
UNIT NAME: WATERFORD 3 CITY / STATE: KILLONA/LA DATE: October 1989 ,
yJ OPERATING STATUS'
, 4
- 1. Docket: 50-382' Notes 2.. Reporting Periods. SEPTEMBER 1989
- 3. Utility
Contact:
PATRICK CENT 0LANZI Phone Number: (504) 464-3360
, , 4. Licensed Thermal Power (MWt): 3390
- 5. Nameplate Rating (Gross Mwe): 1200 ,
~
- 6. Design Electrical Rating (Net MWe): 1104
' 7. Maximum Dependable Capacity (Gross MWe): 1120
- 8. Maximum Dependable Capacity (Net MWe): 1075
- 9. If Changes occur in Capacity Ratings (Items Number 4 Through 8) Since Last Report, 'i Give Reasons: , ,
I i <
- 10. Power Level To Which Restricted, if Any (Net MWe): NONE 11.. ' Reasons For Restrictions, If Any: N/A j L
This Mont.h Yr.-to-Date Cumulative
- 12. Hours In Reporting Period 720.0 6,551.0 35,232.0
{
- 13. Number Of Hours Reactor Was Critical 529.9 6,190.8 28,919.9
[
' 14. Reactor Reserve Shutdove Hours _
i
, 15 Hours Generator On-Line 529.8 6,171.6 28,458.8 i
- 16. Unit Reserve Shutdown Hours l f
W310204B {
i b _ _ _. - f
. .e 0 'y m OPERATING DATA REPORT (Centinued)
This Month Yr.-to-Date Cumulative
- 17. Gross Thermal Energy 1,783,533 20,598,774 , 92,622,370 Generated (NWH)
- 18. Gross Electrical Energy 593,960 __6,941,720_ 31,211,670 Generated (MWH)
- 19. Net Electrical Energy 564,949 6,637,089 29,697,943 Generated (MWH)
- 20. Unit Service Factor 73.6 94.2 80.8
- 21. Unit Availability Factor 73.6 94.2 80.8
- 22. Unit Capacity Factor 73.0 94.2 78.4 (Using MDC Net)
- 23. Unit Capacity Factor 71.1 91.8 76.4 (Using DER Net)
- 24. Unit Forced Outage Rate 0.0 3.0 5.7
- 25. Unit Forced Outage Hours 0,. 0 189.3 1716.0
- 26. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
- 27. If Shut Down At End of Report Period, Estimated Date Of Startup: 11/22/89
- 28. Units In Test Status (Prior to Commercial Operation):
Forccast Achieved a
INITIAL CRITICALITY 3/4/85 INITIAL ELECTRICITY 3/18/85 COMMERCIAL OPERATION 9/24/85 W310204B
S 4il ,
- Q ,;' i$p}
, o 11 eg ; - l . y , ; ' ~ ,
s l
1 V ,
1 AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-382- !
UNIT WATERPORD 3 DATE OCTOBER 1989
' COMPLETED BY PATRICK CENT 0 LANZ 1 TELEPHONE 504-464-3360 3-MONTH SEPTEMBER 1989 DAY - AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (NWe-Net)' (NWe-Net).
l '. 1070 17L 1078 2 _
1067 18 1077 3'. 1070 19 1078 4- 1068 20 1077 5 1070 21 1078 6 1071 22 1069 7 1071 23 15 8' 1072 24 -16 9 107i 25- -9 10 _1071 26 -10 11 1072 27 -10 12 1074 28 -10 13 1072 29 -10 14 1074 30 -10 15 1075 31 N/A 16 1077 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
W310204B I
sv,. .
' ~
UNIT SHUTDOWNS AND POWER REDUCTIONS' '
- O ^
REPORT FOR SEPTEMBER 1989 -e- I '
DOCKET NO '50-382'-
UNIT NAME NATERFURD 3' -'
_j DATE- OCTOBER-1989 COMPLETED BY PATRICK CEWTOIANZI TELEPHONE 504-464-3360 _
Method of Licensee- Cause & Corrective Duration Shutting Event System Component. . Action to No. Date Type t (HOURS) REASON 2 Down Reactor 3 Report { ~-Code 4- Code 5 Prevent Recurrence 89-06 890923 S 190.2 C 1 N/A ZZ ZZZZZZ . Unit removed from -
service to begin Refuel Outage 3.
I 2 3 F: Forced Reason: Method S: Scheduled A-Equipment Failure (Explain) 1-Manual.
B-Maintenance or Test 2-Manual Scram.
C-Refueling 3-Automatic Scram.
D-Regulatory Restriction 4-Continuation 4 E-Operator Training & 5-Load Reduction IEEE Std. 805-1984 License Examination 9-Other 5 ~
F-Administrative IEEE Std. 803A-1983 G-Operational Error (Explain)
H-Other (Explain)
W310204B