W3F1-98-0152 A4.05 PR August 13,1998 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
Subject:
Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating Report Gentlemen:
Attached is the subject monthly report which covers the operating statistics for the month of July,1998. This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.
Should you have any questions regarding the above, please contact me at (504) 739-6242 or M.K. Brandon at (504) 739-6254.
Very truly yours, Av E.C. Ewing jf Director Nuclear Safety & Regulatory Affairs ECE/ALL/ssf Attachment cc:
E.W. Merschoff (NRC Region IV), C.P. Patel (NRC-NRR),
J. Smith, N.S. Reynolds, B. Lewis (Utility Data institute, Inc.),
J.T. Wheelock (INPO Records Center), NRC Resident inspectors 7
l
'll00$6 Office 9808180367 980731 PDR ADOCK 05000382 R
PDR A
.s NRC MONTHLY OPERATING REPORT
SUMMARY
OF OPERATIONS WATERFORD 3 for July,1998 l
The unit operated at an average reactor power level of 90.6% having experienced a forced l
outage and one significant power-derating during the period.
I I
I 8/1188 Page i of 6
PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 for July,1998 There were no pressurizer safety valve failures or challenges experienced during the month.
l l
8/13N8 Page 2 of 6
OPERATING DATA REPORT DOCKET NUMBER :
50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : August 10,1998 COMPLETED BY :
D. S. Freeman TELEPHONE:
(504) 739-6575 OPERATING STATUS
- 1. Reporting Period July,1998 Gross Hours in Reporting Period 744
- 2. Currently Authorized Power Level (MWt) 3,390 j
Maximum Dependable Capacity (Net MWe) -
1,075 i
Design Electrical Rating (Net MWe) 1,104
- 3. Power Level to which Restricted (if any) (Net MWe)
N/A
- 4. Reason for Restriction (if any)
N/A l
THIS YEAR TO MONTH DATE CUMULATIVE
- 5. Number of Hours Reactor was Critical 703.8 s,046.8 95,589.5
- 6. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
- 7. Hours Generator was On-line 692.1 s,oss.1 94,520.8 l
- 8. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 9. Gross Thermal Energy Generated (MWH) 2,283,997 16,975,399 313,957,010
- 10. Gross Electrical Energy Generated (MWH) 763,841 s,768,821 104,988,859
- 11. Net Electrical Energy Generated (MWH) 726,824 s,529,804 100,183,141 l
- 12. Reactor Service Factor 94.6 99.2 84.9
- 13. Reactor Availability Factor 94.6 99.2 84.9
- 14. Unit Service Factor 93.0 99.0 83.9
- 15. Unit Availability Factor 93.0 99.0 83.9
- 16. Unit Capacity Factor (using MDC) 90.9 101.1 82.7
- 17. Unit Capacity Factor (using DER) 88.5 98.5 80.6
- 18. Unit Forced Outage Rate 7.0 1.0 3.3 1/D98 Page : ) of 6 l
E__________________________________.___.
.J
1 OPERATING DATA REPORT DOCKET NUMBER :
50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : August 10,1998 COMPLETED BY :
D. S. Freeman TELEPHONE:
(504) 739-6575 OPERATING STATUS (Cont.)
- 19. Shutdowns Scheduled over next 6 months (type, date and duration of each) :
NONE
- 20. If Shutdown at end of report period, estimated date of startup :
N/A
- 21. Unit is in Commercial Operation.
THIS YEAR TO i
MONTH DATE CUMULATIVE
)
- 22. Hours in Reporting Period 744 5,087 112,656 f
- 23. Unit Forced Outage Hours 51.9 51.9 3,270.9
- 24. Nameplate Rating (Gross MWe) 1,200 Max. Dependable Capacity (Gross MWe) 1,120
- 25. If changes occur in capacity ratings (Items 2 and 24) since the last report, j
give the reasons :
N/A i
t I
wnes rue <as I
AVERAGE DAILY UNIT POWER LEVEL DOCKET NUMBER.
50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : August 10,1998 COMPLETED BY :
D. S. Freeman TELEPHONE:
(504)739-6575 Reporting Period.
July,1998
( NET MWe )
DAY Avg. Power Level DAY Avg. Power Level 1
1,099 16 474 2
1,099 17 (46) 3 1,098 18 52 4
1,098 19 840 S
1,098 20 1,086 6
1,097 21 1,087 7
1,095 22 851 8
1,093 23 928 q
9 1,091 24 1,084 10 1,091 25 1,013 11 1,090 26 1,079 12 1,089 27 1,087
~
13 1,089 28 1,086 14 1,090 29 1,086 15 1,091 30 1,085 31 1,086 INSTRUCTIONS :
On this form, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
8/13NS Page - S of 6
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NUMBER : 50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : August 10,1998 COMPLETED BY :
D. S. Freeman i
TELEPHONE: (504)739-6575 i
i REPORTING PERIOD :
July,1998 Outage Date Duration Shutdown Cause, Comments and 4
Number (yymmdd) Type (Hours) Reason Method Corrective Actions 98-02 980716 F
51.9 A
2 A manual Reactor Trip was initiated when the malfunction of Main Feedwater Pump A resulted in Steam Generator water level dropping to 30% narrow range. A circuit card had shorted out due to condensation dripping onto the card from a conduit above. Replaced circuit card and sealed the above conduit. Further details in CR-98-0947.
98-03 980722 F
0.0 A
5 A power reduction was required to take Main Feedwater Pump A offline due to oscillation problems in the pump speed. High moisture content in the turbine lube oil is blamed for the erratic speed fluctuation. The turbine lube oil and filters were changed out and the pump speed is being controlled via the j
HP governor valve. Further details in CR-98-0984.
l 1
TYPE REASON F - Forced A - Equipment Failure (explain)
S - Scheduled B - Maintenance or Test C - Refueling D - Regulatory Restriction E - Operator Training and METHOD License Examination 1 - Manual F - Administrative i
2 - Manual Scram G - Operational Error (explain) 3 - Automatic Scram H - Other (explain) l 4 - Continuation from Previous Period 5 - Power Reduction 6 - Other (explain) 4 I
t/13MS Page. 6 of 6
.