CORE OPERATING LIMITS REPORT MODERATOR TEMPERATURE COEFFICIENT 3.1.1.3 The Moderator Temperature Coefficient (MTC) shall be maintair.ed within the region of 1

acceptable operation of COLR Figure 2.

Restriction: The reactor shall not be operated with a critical boron concentration less than or equal to 200 ppm to ensure MTC is maintained within COLR Figure 2.

1

)

l

)

4 i

9904060041 990330 PDR ADOCK 05000302<

P PM WATERFORD 3 COLR 3/41-4 CYCLE 10 REVISION 1 i

.?

- CORE OPERATING LIMITS REPORT

. DNBR MARGIN 3.2.4 The DNBR margin shall be maintained by one of the following methods:

a)

When COLSS is in service and neither CEAC is operable: maintain COLSS calculated core power less than or equal to COLSS calculated core power

- operating limit based on DNBR decreased by 13% RATED THERMAL POWER.

b)

When COLSS is out of service and at least one CEAC is operable: operate within the region of acceptable operation shown on COLR Figure 8, using any operable CPC channel.

c)

When COLSS is out of service and neither CEAC is operable: operate within the region of acceptable operation shown on COLR Figure 9, using any operable CPC channel.

4 WATERFORD 3 COLR 3/4 2-6 CYCLE 10 REVISION 1