O Ente gy perations Inc.
Killona. LA 70066 Tel 504 739 6242 r
C. Ewing, til iu ety & Regulatory Affairs W3F1-98-0042 A4.05 PR March 16,1998 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
Subject:
Waterford 3 SES i
Docket No. 50-382 License No. NPF-38 l
Monthly Operating Report i
Gentlemen:
Attached is the subject monthly report which covers the operating statistics for the month of February,1998. This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.
Should you have any questions regarding the above, please contact me at (504) 739-6242 or Tim Gaudet at (504) 739-6666.
Very truly yours, 0
E.C. Ewing Director Nuclear Safety & Regulatory Affairs l!$l$f5fl$fflf hllll ECE/ PRS /ssf Attachment cc:
E.W. Merschoff (NRC Region IV), C.P. Patel (NRC-NRR),
J. Smith, N.S. Reynolds, B. Lewis (Utility Data institute, Inc.),
l J.T. Wheelock (INPO Records Center), NRC Resident inspectors j
OMce
.,n44o 9803200003 980228 PDR ADOCK 050003921 R
j i
NRC MONTHLY OPERATING REPORT l
SUMMARY
OF OPERATIONS WATERFORD 3 for February,1998 The unit operated at an average reactor power level of 99.9% and experienced no shutdowns or significant power reductions during the period.
l 1
i l
l I
l k'IW Page : 1 of 6 C __
1
~
l l
PRESSURIZER SAFETY VALVE l
l FAILURES AND CHALLENGES WATERFORD 3 for February,1998 i
There were no pressurizer safety valve failures or challenges experienced during the month.
I I
i I
AM94 Page. 2 of 4 l
OPERATING DATA REPORT DOCKET NUMBER : 50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : March 3,1998 COMPLETED BY :
D. S. Freeman TELEPHONE: (504)739-6575 i
OPERATING STATUS l
- 1. Reporting Period February,1998 f
Gross Hours in Reporting Period 672 i
- 2. Currently Authorized Power Level (MWt) 3,390
]
Maximum Dependable Capacity (Net MWe) :
1,075 l
Design Electrical Rating (Net MWe) 1,104
- 3. Power Level to which Restricted (if any) (Net MWe)
N/A
'4.
Reason for Restriction (if any)
N/A l
THIS YEAR TO MONTH DATE CUMULATIVE
- 5. Number of Hours Reactor was Critical 672.0 1,416.0 91,958.7
- 6. Reactor Reserve Shutdown Hours o.o 0.0 0.0
- 7. Hours Generator was On-line 672.0 1,416.0 90,901.7 l
_8. Unit Reserve Shutdown Hours 0.0 0.0 0.0 l
- 9. Gross Thermal Energy Geneiated (MWH) 2,276,816 4,790,581 301,772,192
- 10. Gross Electrical Energy Generated (MWH) 778,057 1,635,855 100,855,893
- 11. Net Electrical Energy Generated (MWH) 747,309 1,571,088 96,224,425
- 12. Reactor Service Factor 100.0 100.0 84.4
- 13. Reactor Availability Factor 100.0 100.0 84.4
- 14. Unit Service Factor 100.0 100.0 83.4
- 15. Unit Availability Factor 100.0 100.o 83.4
- 16. Unit Capacity Factor (using MDC) 103.4 103.2 82.1
- 17. Unit Capacity Factor (using DER) 100.7 100.5 80.0
- 18. Unit Forced Outage Rate o.0 0.0 3.4 1/16NS Page : 1 of 6 l
f.
9 OPERAT!NG DATA REPORT L
DOCKET NUMBER : 50 382 UNIT NAME : WATERFORD 3 DATE OF REPORT :
March 3,1998 COMPLETED BY :
D. S. Freeman TELEPHONE: (504) 739-6575 OPERATING STATUS (Cont.)
- 19. Shutdowns Scheduled over next 6 months (type, date and duration of each) :
l NONE
- 20. lf Shutdown at end of report period, estimated date of startup :
N/A
- 21. Unit is in Commercial Operation.
THIS YEAR TO MONTH DATE CUMULATIVE
- 22. Hours in Reporting Period 672 1,416 10s,sas
- 23. Unit Forced Outage Hours o.o 0.0 3,21s.9 l
- 24. Nameplate Rating (Gross MWe) 1,200 Max. Dependable Capacity (Gross MWe) 1,120
- 25. If changes occur in capacity ratings (Items 2 and 24) since the last report, give the reasons :
N/A l
e r a as j
L I
AVERAGE DAILY UNIT POWER LEVEL DOCKET NUMBER : 50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : March 3,1998 COMPLETED BY :
D. S. Freeman TELEPHONE :
(504)739 4 575 s
Reporting Period :
February,1998
( NET MWe )
l DAY Avg. Power Level DAY Avg. Power Level 1
1,113 16 1,112 2
1,113 17 1,111 3
1,112 18 1,112 4
1,112 19 1,112 5
1,111 20 1,112 6
1,112 21 1,113 7
1,112 22 1,113
~
8 1,111 23 1,113 9
1,111 24 1,113
]
10 1,111 25 1,113 11 1,112 26 1,112 12 1,112 27 1,113 13 1,112 28 1,113 14 1,111 15 1,112 INSTRUCTIONS :
On this form, list the average daily unit power level in MWe-Net for each i
day in the reporting month. Compute to the nearest whole megawatt.
l
%WUS Page : 5 of 6
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NUMBER : 50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT :
March 3,1998 COMPLETED BY :
D. S. Freeman TELEPHONE: (504) 739-6575 REPORTING PERIOD :
February,1998 Date Duration Shutdown Cause, Comments and Number (yymmdd) Type (Hours) Reason Method Corrective Actions NONE
~
_ TYPE REASON F - Forced A - Equipment Failure (explain)
S - Scheduled B - Maintenance or Test C - Refueling D - Regulatory Restriction E - Operator Training and METHOD License Examination 1 - Manual F - Administrative 2 - Manual Scram G - Operational Error (explain) i 3 - Automatic Scram H - Other (explain) 4 - Continuation from Previous Period 5 - Power Reduction 6 - Other (explain) i m
j 1
a