Monthly Operating Rept for May 1999 for Waterford 3 Ses.With
ML20195K339
Person / Time
Site: Waterford 
Issue date: 05/31/1999
From: Ewing E, Freeman D
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
W3F1-99-0102, W3F1-99-102, NUDOCS 9906220065
Download: ML20195K339 (7)


Text

V Enti gy Operstions, Inc.

Killona. LA 70006 Tel 504 739 6242 r

C. Ewing, lil Nuc r Safety & Regulatory Af*mrs W3F1-99-0102 A4.05 PR June 14,1999 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Subjec+:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating Report Gentlemen:

Attached is the subject monthly report that covers the operating statistics for the month of May,1999. This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.

Should you have any questions regarding the above, please contact me at f

(504) 739-6242 or A.L. Lewis at (504) 739-6726.

7 Very truly yours, M $(

CC k[a}

Z9 r

E.C. Ewing Director Nuclear Safety & Regulatory Affairs ECE/ALL/rtk Attachment cc:

E.W. Merschoff (NRC Region IV), C.P. Patel (NRC-NRR),

J. Smith, N.S. Reynolds, B. Lewis (Utility Data institute, Inc.),

,,1 P. Lewis (INPO Records Center), NRC Resident inspectors Office

..l o >

8 9906220065 990531 DR ADOCK 0500

(

NRC MONTHLY OPERATING REPORT I

SUMMARY

OF OPERATIONS WATERFORD 3 for May,1999 The unit operated at an average reactor power level of 99.6% and experienced no shutdowns or significant power reductions during the period.

W7/99 Page. I of 6

1 PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 l

for May,1999 i

i There were no pressurizer safety valve failures or challenges experienced during the month.

i l

i 1

Page 2 of 6

OPERATING DATA REPORT DOCKET NUMBER :

50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : June 7,1999 COMPLETED BY :

D. S. Freeman TELEPHONE :

(604) 739-6575 OPERATING STATUS

1. Reporting Period May,1999 Gross Hours in Reporting Period 744
2. Currently Authorized Power Level (MWt) 3,390 Maximum Dependable Capacity (Net MWe) :

1,075 Design Electrical Rating (Net MWe) 1,104

3. Power Level to which Restricted (if any) (Net MWe)

N/A

4. Reason for Restriction (if any)

N/A THIS YEAR TO MONTH DATE CUMULATIVE

5. Number of Hours Reactor was Critical 744.0 2,651.1 101,240.6
6. Reactor Reserve Shutdown Hours o.0 0.0 0.0
7. Hours Generator was On-line 744.0 2,615.9 100,069.5
8. Unit Reserve Shutdown Hours 0.0 0.0 0.0
9. Gross Thermal Energy Generated (MWH) 2,513,051 8,474,850 332,097,948
10. Gross Electrical Energy Generated (MWH) 856,499 2,874,212 111,114,277
11. Net Electrical Energy Generated (MWH) 821,733 2,753,983 106,028,103
12. Reactor Service Factor 100.0 73.2 84.4
13. Reactor Availability Factor 100.0 73.2 84.4
14. Unit Service Factor 100.0 72.2 83.4

~

15. Unit Availability Factor 100.0 72.2 83.4
16. Unit Capacity Factor (using MDC) 102.7 70.7 82.2
17. Unit Capacity Factor (using DER) 100.0 68.9 80.1
18. Unit Forced Outage Rate 0.0 0.0 3.8 MMo Page. 3 of 6

OPERAT!NG DATA REPORT DOCKET NUMBER :

50-382 UNIT NAME : WATERFORD 3

)

DATE OF REPORT : June 7,19*.9 COMPLETED BY :

D. S. Freeman TELEPHONE:

(504)739-6575 OPERATING STATUS (Cont.)

19. Shutdowns Scheduled over next 6 months (type, date and duration of each) -

NONE

20. If Shutdown at end of report period, estimated date of startup :

NIA

21. Unit is in Commercial Operation.

THIS YEAR TO MONTH DATE CUMULATIVE i

22. Hours in Reporting Period 744 3,823 119,952
23. Unit Forced Outage Hours 0.0 0.0 3,ss3.s
24. Nameplate Rating (Gross MWe) 1,200 Max. Dependable Capacity (Gross MWe) 1,120
25. If changes occur in capacity ratings (ltems 2 and 24) since the last report, give the reasons :

N/A 6f7AN Page 4 of 6

p 4

AVERAGE DAILY UNIT POWER LEVEL i

DOCKET NUMBsR :

50-382 UNIT NAME : WATERFORD 3 i

DATE OF REPORT : June 7,1999 I

COMPLETED BY :

D. S. Freeman TELEPHONE: (504)739 4 575 Reporting Period :

May,1999

( NET MWe )

DAY Avg. Power level DAY Avg. Power level

\\

1 1,075 16 1,108 2

1,110 17 1,027 3

1,112 18 1,082 4

1,111 19 1,105 5

1,111 20 1,105 6

1,111 21 1,106 7

1,112 22 1,105 8

1,112 23 1,107 9

1,110 24 1,111 10 1,110 25 1,112 11 1,109 26 1,111 12 1,108 27 1,110 13 1,107 28 1,110 14 1,107 29 1,110 15 1,107 30 1,110 31 1,109 INSTRUCTIONS :

On this form, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

Reflects On-Line Net Generation.

60N9 Page '. 5 of 6

s o

UNIT SHUTDOWNS AND POWER REDUCTIONS l

DOCKET NUMBER :

50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : June 7,1999 COMPLETED BY :

D. S. Freeman TELEPHONE:

(504) 739-6575 REPORTING PERIOD :

May,1999

~

Outage Date Duration Shutdown Cause, Comments and Number (yymmdd) Type (Hours) Reason Method Corrective Actions NONE i

TYPE REASON F - Forced A - Equipment Failure (explain)

S - Scheduled B - Maintenance or Test C - Refueling D - Regulatory Restriction E - Operator Training and METHOD License Examination 1 - Manual F - Administrative 2 - Manual Scram G - Operational Error (explain) 3 - Automatic Scram H - Other (explain) 4 - Continuation from Previous Period 5 - Power Reduction 6 - Other (explain)

Page 6 of 6