ML20141C875

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for April 1997 for Wgs
ML20141C875
Person / Time
Site: Waterford 
Issue date: 04/30/1997
From: Ewing E, Freeman D
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
W3F1-97-0106, W3F1-97-106, NUDOCS 9705190259
Download: ML20141C875 (7)


Text

.

,O En e Opections,Inc.

Killona. LA 70066 Tel 504 739 6242 f

Early C. Ewing, til e afety & Regulatory Affairs W3F1-97-0106 A4.05 PR I

1 May 13,1997 U.S. Nuclear Regulatory Commission q

ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating Report Gentlemen:

Attached is the subject monthly report which covers the operating statistics for the month of April,1997. This report is submitted per Section 6.0.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.

Should you have any questions regarding the above, please contact me at (504) 739-6666 or David Litolff at (504) 739-6693.

Very truly yours, g

\\

l

)

1 l

bY

E.C. Ewing Director Nuclear Safety & Regulatory Affairs

]lb\\{k\\\\{1II !

l ECE/DFL/ssf l

Attachment l

cc:

E.W. Merschoff (NRC Region IV), C.P. Patel (NRC-NRR),

R.B. McGehee, N.S. Reynolds, F. Yost (Utility Data institute, Inc.),

J.T. Wheelock (INPO Records Center), NRC Resident inspectors

}OO019 Office 9705190259 970430 PDR ADOCK 05000302 R

PDR

T b

NRC MONTHLY OPERATING REPORT

[

c

SUMMARY

OF OPERATIONS e

WATERFORD 3 for April,1997 The unit operated at an average reactor power level of 36.4% for the month, having shut i

down on April 12th to commence Refuel Outage #8 (RFO8).

ll 4

f f'

i n

i.

j i

4 4

4 i

i i

4 k

I 55 87 Page : 1 of 6

[

OPERATING DATA REPORT DOCKET NUMBER : 50-382-UNIT NAME : WATERFORD 3 DATE OF REPORT :

May 5,1997 COMPLETED BY :

D. S. Freeman -

TELEPHONE: (504) 739-6575 OPERATING STATUS

1. Reporting Period April,1997 l

Gross Hours in Reporting Period 719

2. Currently Authorized Power Level (MWt) 3,39C Maximum Dependable Capacity (Net MWe) :

1,075

~ Design Electrical Rating (Net MWe) 1,104

3. Power Level to which Restricted (if any) (Net MWe)

N/A

'4. Reaso, for Restriction (if any)

N/A THIS YEAR TO MONTH DATE CUMULATIVE

5. Number of Hours Reactor was Critical 263.s 2,423.5 86,727.s
6. Reactor Reserve Shutdown Hours o.o 0.0 0.o
7. Hours Generator was On-line 263.4 2,423.4 e5,747.s

~

8. Unit Reserve Shutdown Hours 0.0 0.0 0.0
9. Gross Thermal Energy Generated (MWH) 886,717 s,201,718 284,4s9,oa3
10. Gross Electrical Energy Generated (MWH) 303,930 2,801,380 94,987,s80
11. Net Electrical Energy Generated (MWH) 285,401 2,682,488 90,s15,149 12.' Reactor Service Factor 36.6 84.2 85.3
13. Reactor Availability Factor 36.6

.84.2 85.3

14. Unit Service Factor 36.s-84.2 84.3
15. Unit Availability Factor 36.s 84.2 84.3
16. Unit Capacity Factor (using MDC) 36.9 88.7-82.9
17. Unit Capacity Factor (using DER) 36.0 84.4 80.7 l

'18. Unit Forced Outage Rate 0.0 0.0 3.s l-5/5M7 Page :- 3 of 6

c OPERATING DATA REPORT l

DOCKET NUMBER :

50-382 i

UNIT NAME : WATERFORD 3 DATE OF REPORT :

May 5,1997 COMPLETED BY :

D. S. Freeman TELEPHONE:

(504) 739-6575 OPERATING STATUS (Cont.)

19. Shutdowns Scheduled over next 6 months (type, date and duration of each) :

NONE l

?

20. If Shutdown at end of report period, estimated date of startup :

5/22/97

21. Unit is in Commercial Operation.

THIS YEAR TO MONTH DATE CUMULATIVE 1

22. Hours in Reporting Period 719 2,879 101,688
23. Unit Forced Outage Hours 0.0 0.0 3,218.9
24. Nameplate Rating (Gross MWe) 1,200 Max. Dependable Capacity (Gross MWe) 1,120
25. If changes occur in capacity ratings (items 2 and 24) since the last report, give the reasons :

N/A j

T 4

1 j

I

$als7 Page : 4 of 6

_.. _.... _ _. ~...

L,..

.o

~

AVERAGE DAILY UNIT POWER LEVEL i

l DOCKET NUMBER :

50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT: May 5,1997 COMPLETED BY :

D. S. Freeman TELEPHONE:

(504) 739-6575 q

4 i

i Reporting Period :

April,1997

( NET MWe )

l DAY Avg. Power Level DAY Avg. Power Level F

1 1,108 16 (12) l 2

1,107 17 (12) i 3

1,109 18 (12) j 4

1,111 19 (11) 5 1,112 20 (11) i 6-1,112 21 (10) l 7

1,112 22 (11) 8 1,111 23 (10) j 9

1,110 24 (10) l 10 1,109 25 (10) i 11 1,080 26 (10) 12 (27) 27 (11) l.

13 (27) 28 (11) 14 (18) 29 (10) i 15 (11) 30 (11) l INSTRUCTIONS :

i On this form, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

5 J

j S'sM7 Page : 5 of 6

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NUMBER :

50-382 UNIT NAME : WATERFORD 3 DATE OF REPORT : May 5,1997 COMPLETED BY :

D. S. Freeman TELEPHONE: (504) 739-6575 REPORTING PERIOD :

April,1997 Date Duration Shutdown Cause, Comments and Number (yymmdd) Type (Hours)

Reason Method Corrective Actions 97-01 970412 S

455,6 C

1 Unit removed from service to begin Refuel Outage 8.

i l

l 4

TYPE REASON F - Forced A - Equipment Failure (explain)

S - Scheduled B - Maintenance or Test

)

C - Refueling D - Regulatory Restriction E - Operator Training ar3d METHOD License Examination 1 - Manual F - Administrative 2 - Manual Scram G - Operational Error (explain) 3 - Automatic Scram H - Other (explain) 4 - Continuation from Previous Period 5 - Power Reduction 6 - Other (explain) 4 5t5N7 Page : 6 of 6

.