Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML20248B2371998-03-31031 March 1998 Revised Monthly Operating Rept for March 1998 for Indian Point Station Unit 2 ML20029C7801994-03-31031 March 1994 Monthly Operating Rept for Mar 1994 for Indian Point Unit 1. W/940415 Ltr ML20247G5171989-04-30030 April 1989 Monthly Maint Category I Rept Pages from Monthly Operating Rept for Apr 1989 for Indian Point ML20154M5661988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Indian Point Station Unit 2 ML20154M5691988-07-31031 July 1988 Revised Page to Monthly Operating Rept for Jul 1988 for Indian Point Station Unit 2 ML20236P9861987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235Y9681987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20236A5811987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20234D7771987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20237J6511987-07-31031 July 1987 Monthly Operating Rept for Jul 1987 ML20235U7571987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML20215F3711987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20214H5111987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20214E9541987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20206Q6951987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20206R6201987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20207T1321987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20207R6861987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20206R6451987-02-28028 February 1987 Revised Monthly Operating Rept for Feb 1987 ML20211E1381987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20211J1481987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20212P8891986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20207P9801986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20215E8501986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20211Q0501986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20212L9131986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20214D0211986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20203P1081986-09-30030 September 1986 Monthly Operating Rept for Sept 1986 ML20209J0801986-08-31031 August 1986 Monthly Operating Rept for Aug 1986 ML20214K4281986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20207C3021986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20207C3171986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20211F7351986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20198A2731986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20205P6911986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20141E6071986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20141E6121986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20140B8481986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20154P0171986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20141D2331986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20153E3491986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20140B8541986-01-31031 January 1986 Rev I to Monthly Operating Rept for Jan 1986 ML20140A8211985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20141J1861985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20138P4981985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20138M5941985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20136E8811985-10-31031 October 1985 Monthly Operating Rept for Oct 1985 ML20138J7921985-09-30030 September 1985 Monthly Operating Rept for Sept 1985 ML20205C7241985-08-31031 August 1985 Monthly Operating Rept for Aug 1985 ML20134F6881985-07-31031 July 1985 Monthly Operating Rept for Jul 1985 1998-03-31
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217H8501999-10-14014 October 1999 Safety Evaluation Supporting Amend 197 to License DPR-64 ML20206U2551999-02-0909 February 1999 Safety Evaluation Supporting Amend 187 to License DPR-64 ML20236Y1571998-08-0303 August 1998 Part 21 Rept Re ASTM A351,GR. CF8 Matl at Indian Point Being Out of Specifications in Molybdenum & Chromium.Cause & Corrective Actions Are Not Stated ML20236V4281998-07-13013 July 1998 Safety Evaluation of TRs WCAP-14333P & WCAP-14334NP, PRA of RPS & ESFAS Test Times & Completion Times. Repts Acceptable ML20236T5511998-06-24024 June 1998 Consolidated Edison Co of Ny,Indian Point Unit 2,Drill Scenario Number 1998C ML20248B2371998-03-31031 March 1998 Revised Monthly Operating Rept for March 1998 for Indian Point Station Unit 2 ML17264A9381997-07-10010 July 1997 Deficiency Rept Re Potential Safety Hazard Associated w/FM-Alco 251 Engin,High Pressure Fuel tube-catalog: 4401031-2 in Which Dual Failure Mode Exists.Caused by Incorrect Forming Process ML18153A1431997-06-10010 June 1997 Part 21 Rept Re Possible Machining Defect in Certain Stainless Steel Swagelok Tube Fitting Bodies.Facilities Have Been Notified About Possible Problem ML20210E3591997-03-27027 March 1997 Part 21 Rept Re Sorrento Electronics Inc Has Determined Operation & Maint Manual May Not Adequately Define Requirements for Performing Periodic Surveillance of SR Applications.Caused by Hardware Failures.Revised RM-23A ML1005008001997-02-28028 February 1997 Conditional Extension of Rod Misalignment TS for Indian Point 3. ML20115J3981996-07-22022 July 1996 Interim Part 21 Rept Re 3/4 Schedule 80 Pipe Furnished to Consolidated Power Supply.Investigation Revealed Only One Nuclear Customer Involved in Sale of Matl ML20096E5101995-12-31031 December 1995 Resubmitted Rev 13 to QA Program ML17059A3611994-07-0606 July 1994 Emergency Action Level Verification & Validation Rept. ML17311A0181994-05-13013 May 1994 New York State EAL Upgrade Project Verification & Validation Rept. ML20029C7801994-03-31031 March 1994 Monthly Operating Rept for Mar 1994 for Indian Point Unit 1. W/940415 Ltr ML20056E5171993-08-31031 August 1993 Technical Review Rept, Tardy Licensee Actions ML20062J2281993-07-23023 July 1993 Consolidated Edison Co of Ny Indian Point Unit 2,Drill Scenario 1993 ML20118A2681992-12-31031 December 1992 Consolidated Edison Co of Ny Indian Point,Unit 2 Exercise Scenario,1992 ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20127P5861992-11-23023 November 1992 Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl ML20096H2301992-05-21021 May 1992 Special Rept:On 920504,south Side Lower Electrical Tunnel Detection Sys 8 Taken Out of Svc for Mod to Reposition Detection Sys Run of Conduit.Detection Sys Declared Operable on 920520 After Mod Completed & Sys Retested ML20079F9181991-05-31031 May 1991 Structural Evaluation of Indian Point,Units 2 & 3 Pressurizer Surge Lines,Considering Effects of Thermal Stratification ML20059E9461990-08-31031 August 1990 Nonproprietary Rev 2 to Indian Point 2 Tube Fatigue Reevaluation ML20059G2011990-07-31031 July 1990 Final Rept on Steam Generator Insp, Repair & Restoration Efforts During 1990 Midcycle Insp ML20058K4151990-06-30030 June 1990 Steam Generator Insp,Repair & Restoration Program Presentation to Nrc ML20058K4121990-06-30030 June 1990 Status Rept,Indian Point Unit 2 Mid-Cycle Steam Generator Insp Presentation to Nrc ML20043A4891990-05-30030 May 1990 Nonproprietary Indian Point Unit 2 Steam Generator Insp, Repair & Restoration Program. ML20042F1441989-12-31031 December 1989 New York Power Authority Annual Rept for 1989. W/900430 Ltr ML19332B9371989-11-30030 November 1989 Nonproprietary Info Presented to NRC Re Indian Point Unit 2 Steam Generator Secondary Side Loose Objects. ML19332D6661989-10-31031 October 1989 Nonproprietary Rev 2 to Indian Point Unit 2 Steam Generator Girth Weld/Feedwater Nozzles Rept Spring,1989 Outage. ML20247J8161989-07-31031 July 1989 Safety Evaluation for UHS Temp Increase to 95 F at Indian Point Unit 3 ML20248B3171989-06-30030 June 1989 Rev 1 to Nonproprietary WCAP-12294, Indian Point Unit 2 Steam Generator Girth Weld/Feedwater Nozzles Rept,Spring 1989 Outage ML20248D3631989-06-30030 June 1989 Rev 1,to Indian Point Unit 3 Reactor Vessel Fluence & Ref Temp PTS Evaluations ML20247N5331989-05-31031 May 1989 Nonproprietary Indian Point Unit 2 Steam Generator Girth Weld/Feedwater Nozzles Rept Spring,1989 Outage ML20247J8071989-05-31031 May 1989 Containment Margin Improvement Analysis for Indian Point Unit 3 ML20247G5171989-04-30030 April 1989 Monthly Maint Category I Rept Pages from Monthly Operating Rept for Apr 1989 for Indian Point ML20244C3311989-04-10010 April 1989 Safety Evaluation Supporting Amend 137 to License DPR-26 ML20248F4211989-03-31031 March 1989 NSSS Stretch Rating-3,083.4 Mwt Licensing Rept ML20235V5931989-03-0202 March 1989 Special Rept:During Cycle 6/7 Refueling Outage Scheduled from Feb-May 1989,openings Will Be Made in Plant Penetration Fire Barriers in Order to Install Various Mods. Fire Watches Posted & Fire Detection Tests Completed ML20248F3001988-12-31031 December 1988 10CFR50.59(b) Rept of Changes,Tests & Experiments Completed in 1988 ML20246E2711988-12-31031 December 1988 Con Edison 1988 Annual Rept ML20196D3011988-10-31031 October 1988 Reactor Vessel Matl Surveillance Program for Indian Point Unit 2 Analysis of Capsule V ML20155H2541988-09-30030 September 1988 Rev 2 to Indian Point Unit 2 (NRC Bulletin 88-008 Thermal Stresses in Piping Connected to RCS) Indentification of Unisolable Piping & Determination of Insp Locations ML20154M5661988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Indian Point Station Unit 2 ML20154M5691988-07-31031 July 1988 Revised Page to Monthly Operating Rept for Jul 1988 for Indian Point Station Unit 2 ML20151N7881988-07-31031 July 1988 Rev 1 to Charpy Toughness & Brittle Transition Temp Characterization of HAZ High Hardness Zone of Indian Point Unit 2 Steam Generator Girth Weld by Gleeble Weld Thermal Cycle Simulation ML20006B4741988-05-31031 May 1988 Nonproprietary Indian Point Unit 2 Evaluation for Tube Vibration Induced Fatigue. ML20151N7821988-05-31031 May 1988 Fracture Sensitivity Study of Girth Weld 6 Repaired Configuration,Indian Point Unit 2 ML20153F9161988-04-28028 April 1988 Changes,Tests & Experiments - 1986 ML20151T4681988-01-31031 January 1988 Experimental & Finite Element Evaluation of Spent Fuel Rack Damping & Stiffness 1999-02-09
[Table view] |
Text
~
s
~ * * ..
OPERATING DATA REPORT DOCKET NO. 50-9a7 DATE a-a o3 COMPLE1 ED 11Y E_ rich.
, TELEPHONE (41a1 496-5155 OPERATING STATUS
- 1. Unit Name: Tnainn onint U".it "c. 2
- 2. Reporting Period: March 1983 *
- 3. Licensed Thermal Power IMWt):
2758
- 4. Nameplate Rating (Gross MWe):
1013-
- 5. Design Electrical Ratin; 4 Net MWel:
873
- 6. Maximum Dependable Capacity (Gross MWe): on0
- 7. Maximum Dependable Capacity (Net MWc): AAA 871f Changes Occur in Capacity Ratings 1 Items Number 3 Through 7) Since Last Report.Gise Reasons:
No chancine _.
- 9. Power LeselTo which Restricted.lf Any (Net MWe): none
- 10. Reasons For Restrictions. If Any:
N/A Tids Month Yr.-to-Date Cumulative
- 11. Hours in Reporting Period 74a n69 75795 725.07 1743.87 49901.4s
- 12. Number Of Iloun Reactor Was Critical 16.25 23.13 1601.64
- 13. Reactor Resene Shutdown Hours 712.07 1440.75 48280.05
- 14. Hours Generator On-Line 0 0 0
- 15. Unit Resene Shutdown flours 1865423 3545310 124981986
- 16. Gross Thermal Energy Generated (MWH) 579870_.... 1098300 1Rsn1n7s
- 17. Gross Electrical Energy Generated (MWil) _
IS. Net Electrical Energ) Generated (MWil) 556790 1038406 36770461 95.7 66.7 62.9
- 19. Unit Senice Factor 95.7 66.7 62.9
- 20. Unit Asailability Factor 86.6 55.6 55.8
- 21. Unit Capacity Factor (Using MDC Net) 5 3 . '/ 55.1 54.9
- 22. Unit Capacity Faetor (Using DER Net) 0.7 14.4 1n.n
- 23. Unit Forced Outage Rate
- 24. Shutdowns Scheduled Oser Nest 6 Months (Type.Date.and Duration of Each):
'l None
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
N/A
- 26. Units in Test Status (Prior to Commercial Operationk Forecast Achiesed
\
INill \ L C RillC \ Lil Y N.A.
\ \
INilI \t. FLt Cl RICIIT cmnirReiu oPrR mon \' \_
i 8306020276 830404 pyn g PDR ADOCK 05000247 PDR R '
~~ . . ,
, AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-247 I.P. Unit No. L DATE 4-4-83
, COMPLETED BY TELEPHONE (914) 526-5155
. MONTH MARCH 1983 DAY AVERAGE DAILY POWER LEVEL
~
DAY AVERAGE DAILY POWER LEVEL (Mbe-Net) (MWe-Net) 1 841 17 754 2 759 gg 709
. 3 583 ,,
769 4 839 20 757 5 841 21 346 6
831 835 835 840
~ '
23 3 836 24 853 9
NO 23 10 834 26 53 11 ___
831 471 12 826 834 g
13 573 845 29 14 786 30 849 808 846 15 3g 16 736 da >
INSTRUCTIONS On this format.!ist the average daily unit power levelin MWe Net for each day in the reporting month. Compute tu the nearest whole nwgswatt.
(4 /77 )
S
, . .. - __ ~ - . . _ . - . , . .
3 4 P DOCKET NO. 50-247 UNIT SHUTDOWNS AND POWER REDUCTIONS I.P. Unit 57 -
UNIT N A'.lE DA TE .d=A= Q 3 COMPLETED BY P_ Meh REPORTMONT11 MARCII 1983 TELEPilONE (914)526-5155
, .]g 3 kE Licensee ,E-r, % Cause & Cor recieve W. D.ne i 5= s .h s 5 Event p Action to 5 uo{
! l-35 5 ;5 g Report *: mU Present Recurrence O .
I N/A 3l0303 F 0 ,.H 4 None HH HT EXCH Load reduction to control high D condensate temperature.
7 830313 F 4.85 A 3 CH PUMP XX Spurious speed runback on 21 None B Main Boiler Feed pump resulting in low level trip on No. 23 S/G.
N/A 8J,0321 F 0 A 4 CH HT EXCH Load reduction due to condenser None F tube leaks 8 830326 S 27.08 A 2 CH VALVEX Unit shutdown to repair None F #24 Main Boiler Feed Water Reg.
Valve stem packing leakage.
t i 2 3 4 i
F: Forsed ' Reason: Method: Exhibit G - Inst ructions S: Sacduled A 1:quipment Failure (lixplain) 1 Manual for Pseparation nf Data Bataintenanec oi Test 2-Manual Scram. Entry Sheets for Licensee C Refueling 3-Automatic Scram. Event Report (LE R1 Fi!c iNURI.G- ,
D Regulatory Restriction '4-Other (Explain) 0161)
E-Operator Training & Ucense Examination F Administrative . 5 G-Operational Error (Explain) Exhibis 1 - Same Source (9/77) Il Other (Explain) ,,
SMFARY OF OPEPATING EXPERIENCE Docket No.: 50-247 Date: 4/8/83 Cmpleted by: J. Curry Telephone No.: (914) 526-5235 Indian Point Unit No. 2 began the month of Parch at 100% reactor pomr. On Parch 2, a contract diver became entrapped in the service water pump forebay while performing underwater inspection and cleaning. To rmove him required a reduction in plant load to approximately 180 PMe and a concurrent shutdown of all but one service water pucp. - He was not injured.
On March 7 a brief load reduction of approxurately 170 M1e was required to clear an obstruction frm the forebay of No. 24 circulating water puup after which the unit was returned to full power.
Unit 2 tripped autmatically on March 13 due to a low level condition in No. 23 steam generator in ccxtbination with a steam flow /feedwater ficw mismatch signal. 'Ihe trip occurred during a load reduction to cmpensate for a loss of speed control on No. 21 main boiler feedwater pump. The unit was returned to service the same day. Peactor power was raised to 42%
while the feedwater pump was repaired and full power operation was restored on March 14.
On March 16, load was reduced to approximately 670 Mie to permit removal of condensers frcrn service for inspection and cleaning. During the period frczn March 16 to Parch 23, three of the condenser sections were cleaned and several condenser tube leaks were plugged. No. 21 Circulating Water Pump was returned to service and full power was restored by_ Parch 22.
The unit was reoved frcm service on March 26 to repair a sten packing gland leak on the main feedwater regulating valve for No. 24 steam genera-tor. The unit was returned to service on March 27 and operated at 100% for the rmainder of the period. . . .
I
D'ocket No. 50-247 Date: 4/14/83 Completed by: J. Bahr March, 1983 Indian-Point Unit No. 2 Date Component MWR Malfunction Corrective Action 11/4/82 cont. Cooling 2000 Pump frozen Pump replaced.
Gas and Part Pump 10/20/82 Main Steam 4438 Leaks past Removed valve and System MS-49B seat replaced disc and Safety Valve cotter pin.
11/11/82 Feedwater 4865 Valve packing Replaced packing System Valve Leak BFD 60-3 10/29/82 CVCS Valve 1464 Valve leak Installed new valve 204B internals and repacked ,
10/29/82 Containment 5045 Valve leak Replaced worn gear Isolation sector in housing ,
System Valve .
PCV-1190 10/29/82 PCV-1190 5046 Valve leaks Replaced T rings and PCV-1191 and 5047 11/4/82 Main Steam 4902 Repacking re- Valves repacked System MS-1 quired following
- Valves (4 S/G hydrostatic valves) test 11/11/82 Valve for 4979 Packing leak Valve repacked Steam Gen- causing SG i
erator Level level instru-Transmitter mentation LT-417C error 10/20/82 No. 23 Steam 228 Valve leaks Removed valve Generator bonnet, replaced Safety Valve disc insert and MS-45C cotter pin.
11/1/82 containment 203-5495 Pailed to open Replaced failed control r,1: . i t ,
. lay i
e v er ,n -,t- ,e
Docket No. 50-247 Date: 4/14/83 Completed by: J. Bahr March, 1983 Indian Point Unit No. 2 Date Component MWR Malfunction Corrective Action 11/5/82' Pressurizer 4817 Breaker Replaced breaker Heater Breaker, overheats Circuit No. 2, Panel No. 23 10/27/82 Instrument 3100 Air leaks Air lines resweated Air Lines and 111 to Valves 791 and FCV-110A 11/4/82 Temperature 5011 Gauge broken Temperature gauge Gauge for replaced.
Dessicant Dryer Tank 11/4/82 Instrument 5190 Sight glass Rechargn? dryer Air System for freon No. 22 Re- level low, frigerant indicator Dryer shows moisture 11/5/82 Service Water 4714 Gear mal- Replaced gear box System Outlet functii. ..
valve of PCV 1179 10/19/82 HVAC System 419 Manual operators Replaced manual valve PCV1191 broken operators and PCV 1192 10/29/82 Safety In- _3086 Valve requires Valve repacked jection valve repacking and and new studs No. 850A renewed studs and nuts installed 10/23/82 Safety In- 4213 Diaphragm Diaphragm replaced jection leaks system Valve No. 1830
Docket No. 50-247 Date: 4/14/83
. Completed by: J. Bahr March, 1983 Indian Point Unit No. 2 Date Component MWR Malfunction Corrective Action 11/5/82 Post Accident 5092 Valve broken Replaced broken Sample System in closed valve bonnet Valve 1875F position 10/27/82 cvCS Valve 5134 valve packing Valve replaced No. 344 leaks 10/29/82 CVCS Valve 5436 Diaphragm leak valve bonnet No. 267B and diaphragm replaced 11/4/82 No. 23 Emer - '5141 Cooling System Nine tubes gency Diesel leak in water jacket Generator plugged Jacket Water
. Cooling System l
.s-
%e I
f e
, - ~ - - - . - - - - - -
,-s /
John D. O'Toob
. . Vice Presedent Consohdated Edison Company of New York, Inc -
4 Irving Place. New York. NY 10003 Telephone (212) 460-2533 April 15, 1983 Re: Indian Point Unit No. 2 Docket No. 50-247 Mr. William G. Mcdonald, Director
. Office of. Management Information and Program Control c/o Distribution Services Branch, DDC, ADM U. S. Nuclear Regulatory Commission Washington, D. C. 20555
Dear Mr. Mcdonald:
Enclosed you will find two copies of the Monthly Operating Reporting related to Indian Point Unit No. 2 for the month of March 1983.
Ve truly yours,
/
l f. % s Y Encl.
cc: Mr. Richard DeYoung, Director (40 copies)
Office of Inspection and Enforcement c/o Distribution Services Branch, DDC, ADM U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Mr. James M. Allan, Acting Regional Administrator Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pa. 19406
-Mr. Thomas Foley, Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 38 Buchanan, New York 10511
'/
- - . - . - .