',P f ",,

31; 4

-M 3 :.

s O OPERATING DATA REPORT

/

f.

~

Docket No.,50-286 Date 01-02-87

~

Completed By.

L.. Kelly-Telephone 914-739-8200~

1

!dPERATING STATUS U nit Name':.-Indian' Point No. 3 Nuclear Power Plant Notes 1.?

I 1 2.,

R: porting Period:

December 1986

.3.' Licensed Thermal Power-(MWt):

3025

  • 4., Nameplate Rating;(Gross MWe):

1013 15c D3 sign Electrical Rating.(Net MWe):-

965-6.;=M ximum Dependable Capacity (Gross'MWe):- 965 f7, Mnximum Dependable ~ Capacity'(Net MWe): '

930

'8. : :If Ch$n~ges.decur. in Capacit[ Ratings (Items Numb'er 3 through 7) Since Last Report.

Give Reasons:

9.

Power Level to Which Restricted, If Any (Net MWe):. 930 Net MWe 110..; Reasons for Restrictions, If Any:
  1. 33 Low pres ure turbine was modified by replacina

-two rows of blades with baffle assemblies.

1 This' Month Yr. to Date Cumulative-2.11.;.. Hours In Reporting Period 744 8,760 90,625

12.' ' Number of Hours Reactor Was Critical 744 6,581.78 53,849.16
13. : Reactor Reserve Shutdown Hours 0

O O

i.

.14~. ~ Hours Gene'rator on-Line:

744 6,432.62-52,065.59

~15.-; Unit Reserve' Shutdown Hours 0

0 0

.16.1 Gross Thermal Energy Generated (MWH) 2,247,782.02 17,755,086-138,532,861

17. Gross Electrical Energy Generated (MWH) 719,670 5,740,080 43,304,615
18. Net Electrical Generated ~(MWH) 694,635-5,525,641 41,540,280-19," ': Unit' Service Factor 100.0 73.4 57.5

.20.

Unit Availability Factor 100.0.

73.4 57.5 21.. Unit. Capacity Factor (Using MDC Net) 100.4 66.5*

49.19*

22.' : Unit Capacity Factor (Using DER Net) 96.8 65.4

-47.5

23. ~ Unit Forced Outage Rate 0.0 21.4 19.9
24.

Shutdowns Scheduled Over Next 6 Months (Type.Date and Duration of Each):

  • Weighted Average Cycle 5/6 Refueling Outage Est. May, 1987
25 '.

If Shut'Down at End of Report Period. Estimated Date of Startup:

26.

Units IniTest Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 7h \\x y

8701200514 861231 PDR ADOCK 05000286 i

R,.

PDR 7

gj.

s?

4 AVERAGE DAILY-UNIT POWER LEVEL 4y DOCKET NO.

50-286 UNIT IP-3 l

DATE l-2-87 COMPLETED BY L. Kelly i

TELEPHONE (914) 739-8200-MONTH' December 1986

'. DAY', AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 934 17 933 2

935-18 934 3

934 19 933 4

935 20 933 5

935 21 935 6

934 22 933

.7 933 23 932 8

935-24 933 9

934 25 935 10 933 26 934 11 935 27 934 12 934 28 933 13 934 29 933 14 935 30 931 15 933 31 933 16 933 INSTRUCTIONS:

On this format, list the average daily unit power level in MWe-Net for each day.

in the reporting month. Compute to the nearest whole megawatt.

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

'50-286 UNIT NAME Indirn Pri c 3 DATE 01-02-87 REPORT MONTH nn,-omwo,-

1986 TELEPHONE 914-739-8200 m

O Et to

=Om E

vUE Licensee a

Eo Cause & Corrective e

N E

.E $ "

Event E.3 Action to j :E sE jN Report #

]x 0 E"

Prevent Recurrence No.

Date NONE I

2 3

4-F: Forced Reason:

Method:

. Exhibit F - Instructions-S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance of Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File (NUREG D-Regulatory Restriction 4-Other (Explain) 0161)

E-Operator Training & License Examination F-Administrative

~

G-Operational Error (Explain) 5 H-Other (Explain)

Exhibit H - Same Source

y

. a MONTHLY I & C CATEGORY I REPORT'

-December-1986

MONTH WRf DATE EQUIPMENT MALFUNCTION CORRECTIVE ACTION-6324' 12/1/86

' Reactor Coolant System,.

Rod bottom' bistable alarm Replaced conditioning card'

~

Rod. Bottom Bistable C-3

.and light annunciates without-rod drop 6310 12/9/86 Radiation Monitoring High background reading Replaced detector?

System, Vapor Containment Noble Gas Monitor R-12..

6338 12/11/86

  1. 31 Fan Cooler Unit High Alarm Bistable set.Iow Reset Alarm Bistable Level Alarm 6221 12/15/86 Nitrogen Supply Primary Brok'en face plate-on pressure Replaced face' plate-Auxiliary Building, Pressure indicator Indicator-PI-17 5931 12/18/86 Service Water Pump Unable to vent flow gauges.on' Replaced Vent Valves.on #31,.

Flow Instrumentation

  1. 31 f32 and #35 Service Water
  1. 32, and #35 Service Water.

Pump Pump Flow Meters 9

e I

s

MONTHLY MAINTENANCE CATEGORY I REPORT December-1986-MONTH WR#

DATE EQUIPMENT MALFUNCTION CORRECTIVE ACTION 9280 12/1/86

  1. 33 Service Water Pump

' Packing leak Replaced packing 9069 12/2/86

  1. 31 Primary Water Pump Valve' leaks by

_ Replaced compression 4

Discharge Isolation Valve assembly PW-16 9071 12/3/86

  1. 32 Primary Water Pump Valve leaks by

- Replaced compression Discharge Isolation Valve assembly--

?W-35 9261 12/3/86 Hydrogen Sampling System, Valve has dual indication.

Repaired limit. switch Containment Isolation Valve-SOV-514 9386 12/3/86 Radiation Monitoring System, During P.M. found blower Replaced. vanes, bearings-RE-101 4th Floor Adminis-internals worn and drive ~ belt tration Building 9388 12/4/86 Radiation Monitoring System, During P.M. found blower Replaced vanes and bearings.-

Plant Vent Stack Radiation internals worn Monitors R-13/14 9389 12/4/86 Radiation Monitoring System, During P.M.-found blower Replaced vanes, bearings, Containment Plant Vent internals worn and drive helt Radiation Monitors R-11/12 9400 12/5/86 Emergency Diesel Generator Open thermostat' wire Repaired wiring Ventilation Fan #319 t

l MONTHLY MAINTENANCE CATEGORY I REPORT December

1986 MONTH.

WR#

DATE EQUIPMENT MALFUNCTION CORRECTIVE ACTION 9455 12/8/86 Chemical and Volume Control Seal tank overflowing Repacked pump System, #31 Charging Pump 9374 12/8/86

  1. 31 Waste Gas Compressor During P.M. found compressor Replaced grease seals and grease seals.and bearings worn bearings.

9456 12/11/86 Chemical and Volume Control Weld leak on. vent line' Replaced vent line System, #33 Charging Pump Suction Sr:Lilizer Heating Tank 9417 12/12/86 Chemical a'nd Volume Control Open thermocouple wire Replaced thermocouple wire-System, Boric Acid Heat Trace, Circuit #39 9473 12/16/86 Chemical and Volume Control Seal tank overflows Repacked pump System, #33 Charging Pump 7952 12/19/86 Fuel Storage Building.

Solenoid valve on exhaust Replaced solenoid valve Exhaust Damper damper inoperative 9524 12/23/86 Chemical and Volume Control Loose wire connection Repaired wiring connection System, Boric Acid Heat Trace, Redundant Circuit #32 9032 12/30/06 Waste Gas Analyzer Valves leak by Replaced valves Sample Valves 1600F, 1600G, 1600H and 160GJ 9

j

+

.' s

SUMMARY

OF OPERATING EXPERIENCE DECEMBER.1986

- Indian Point Unit #3 was synchronized to the bus for a total of 744 hours0.00861 days <br />0.207 hours <br />0.00123 weeks <br />2.83092e-4 months <br />, producing:a gross. generation of 719,670'MWe for this reporting period.

il The Unit. remained on line for the entire reporting period without experiencing any, trips or reportable load reductions.

9 k

-y-

.a.

4 Inden Point 3 y

Nuclear Power Plant P.O. Box 215 Buchanan, New York 10511 914 739 8200

  1. > NewWrkPbwer 4# Authority January 5, 1987 IP3-WAJ-001Z IP3-LMK-001H Docket No.

50-286 License No. DPR-64 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention: Document Control Desk

Dear Sir:

Enclosed you will find twelve copies of the monthly operating report relating to Indian Point 3 Nuclear Power Plant for the month of December, 1986.

Very y yo rs,

[L+

W iam A. Josiger esident Manager LK/sn:3:06 Enclosures (12 copies) cc: