4 e

x irard development inc.

f P.O. BOX 338e RANCHO CORDOVA, CA 9574b 916/635-8159 Document Control Desk Nuclear Regulatory Commission Washington D.C. 20555 Indian Point Station 8/3/98 Broadway & Bleakley Ave.

Buchanan, NY 10511 Attn: Vice President of Nuclear Power j

10CFR21 NOTIFICATION Your Purchase Order #8508061, release 0 Our Delivery # 5231N shipped on 2/15/98 OurIIeat Code #73520 Part #3/8-1/2T-500SS-2D Material was ASTM A351, GR. CF8 Subsequent tests showed the material was out of specifications in molybdenum & chromitmi, Spec.

Heat Code 73520 molybdenum

.50 max

.93 chromium 18.0-21.0 17.76 l

1-0 V

i0

't 9008110220 980803 PDR ADOCK 05000003 l