ML20210E359
| ML20210E359 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley, Millstone, Dresden, Oconee, Indian Point, Hope Creek, Sequoyah, Turkey Point, South Texas, Zion |
| Issue date: | 03/27/1997 |
| From: | Jackie Jones GENERAL ATOMICS (FORMERLY GA TECHNOLOGIES, INC./GENER |
| To: | NRC |
| References | |
| REF-PT21-97 NUDOCS 9704010413 | |
| Download: ML20210E359 (5) | |
Text
_ _ _ - _ _ _ _ _ _ - _ _ - _ _ _. - _ _ _ _ _ _ _ _ -
C'$X'C22 Gn LICEt6ltG 247 FBt ITH 27 '97 13:10 h CENERAL MDR0lC8i so -/oS JAarch 27,1997 NRC Operci,ons Center
~
= = u man
'J.S. Nuclear Regulatory Commission Washington, rt C. 20555 Sub)pa 10CFR21 R9portableitem T7 IN1i D 1 ; 'i Gentlemen:
This letter is provided in compliance with the requirements of 10CFR 21.21.
The information following is in accordance with the repot ag requirements of 10CFR2121(a)(4):
i) PersonInforming the Commission:
John E. Jones 1
Sr. Vico President, Administration l
General Atomics 3550 General Atomics Court l
San Diego, CA 92121
- 11) Descriptionof thedefect in the process of performing software verification and validation (V&V) of the RM 23A Control and Display Module (part number 03575300-001), Sorrento Electronics, Inc. (SE) has determined that the Operation and Maintenance (O&M) Manual for the RM 23A may not adequately define the requirements for performing periodic surveillance of certain safety related applications.
iii) Identi5cationof thefirm:
Sorrento Electronics, Inc.
An Afbliate of General Atomics f
{$A"lMSE8Sho JE/9 010008 MlpHBPPPPNM 4
3650OtheAAL ATOMitiCOUAT,SANDi100 CA $21211194 P 4 904 88604. $AN DilGO. CA 92100 $)la t$th a6fr3000
_-- ~
GS52022 Gn t.lCD Gltu 347 P03 iTR 27 '97 13:10 Iv) Thenatureof defect A series of diagnostics tests are used toldentify hardwaro failures which may not be dciected during normal operation. Those diagnostics tests are described in the O&M Manual and include:
a)
Lamp and LED test b)
Keyboard input test c)
Clockinterrupt test d)
Digitalinputs test e)
Digitaloutputs test f)
Analog outputslost The O&M Manual does not adequately emphasize the need to consider performing these tests as part of normal maintenance to declare operability in safety related applications, v) The date on which the information was obtained:
January 30,1997 vi) The number and locaton of the components.
(See Attachment 1) vil) Correc0ve action
- SE will make the individual purchasers aware of this possible problem and will revise the RM-23A Operation and Maintenance Manual E-115-1256 (Rev.1) to clarify the periodic surveinance requiren ents for the RM-23A.
viii) Advice to Purchasers:
The functions tet ted by the above diagnostics tests should be evaluated for the affect on plant safety, hiy function which affects plant safety should be periodically tested.
SE recommends that as a minimum, the clock interrupt test should be wrformed since the RM-23A will not schedule tasks without the interrupt acing present.
The interval between these tests should be determined by the Purchaser,
4552c22 on ucosite 247 re2 rinR 27 'rfr 23:30 if you have any questions concerning this report, please cal Dr. Keith E. Asmussen at 619455 2823 or Mr. Brian Laney at 6194554369.
Any technical questions should be addressed to Dirk Koopmin at 6194574899.
Yours Very Trt.ly,
\\
q 1
. ;- w; n E. Jon I
Vice Pr t, Administration cc: NRC Region IV e
9
4%?C22 CA LICD 61tG 247 rol
!1nR 27 '97 13:17 Locatlans of RM 23A's i
Number of RM 23A's Site innfallad in System l
BeaverVaney 16 Bruce A 10 Chinshan 1 and 2 6
Dresden 2 and 3 1
Hope Creek 18 Indian Point 3 16 Kori1 and 2 6
Kuosheng 1 and 2 7
Millstone 2 1
Oconee 1,2, and 3 6
Sequoyah 1 and 2 8
South Texas 1 and 2 34 Turkey Point 3 and 4 3
Zion 1 and 2 1
a
.t GENERAL INFORMATION or OTilER EVENT NUMDER:
32033 LICENSEE: GENERAL ATOMTCS, SAN DIEGO, CA NOTIFICATION DATE: 03/27/97 CITY: SAN DIEGO REGION: 4 NOTIFICATION TIME: 15:00 (ET)
COUNTY:
STATE: CA EVENT DATE:
01/30/97 LICENSEN:
AGREEMENT: Y EVENT TIME:
12 00 [PST)
DOCKET:
LAST UPDATE DATE:
03/27/97 I
NOTIFICATIONS I
LEANNE !!ARRISON, R1 RDO NRC NOTIFIED BY: SilIRLEY SMITH DAVID VERRELLI, R2 RDO 11Q OPS OFFICER:
DICK JOLLIFFE ROGER LANKSBURY, R3 RDO TOM STETKA, R4 RDO EMERGENCY CLASS: NOT APPLICABLE VERN llODGE NRR l
10 CFR SECTION:
CCCC 21.21 UNSPECIFIED PARAGRAPil EVENT TEXT
- 10CFR21 REPORT ON GENERAL ATOMICS RADIATION MONITOR MAINTENANCE TESTS -
SORRENTO ELECTRONICS, INC (SE), AN AFFILIATE OF GENERAL ATOMICS, DETERMINED TilAT THE OPERATIONS AND MAINTENANCE MANUAL FOR RADIATION MONITOR #RM-23A (CONTROL AND DISPLAY MODULE PART NUMBER #03575300-001) MAY NOT ADEQUATELY DEFINE Tile REQUIREMENTS FOR PERFORMING PERIODIC SURVEILLANCE TESTS OF CERTAIN SAFETY RELATED APPLICATIONS.
SE IS RECOMMENDING T!!AT ADDITIONAL DIAGNOSTIC TESTS BE RUN AS PART OF NORMAL MAINTENANCE ACTIVITIES IN ORDER TO IDENTIFY !!ARDWARE FAILURES WHICH MAY NOT BE DETECTED DURING NORMAL "PERATIONS.
SE IS REVISING TilEIR OPERATIONS AND MAINTENANCE MANUAL TO
'FLECT TilIS CHANGE.
GENERAL ATOMICS IS NOTIFYING TIIEIR FOLLOWING NUCLEAR CUSTOMERS:
BEAVER VALLEY, BRUCE, CilINSilAN, DRESDEN 2 & 3, liOPE CREEK, INDIAN POINT 3 KORI, KUOSl!ENG, MILL 3 TONE 2, OCONEE, SEQUOYAH, SOUTH TEXAS, TURKEY POINT 3 & 4, AND ZION.
l