Text
. __.
-w e
~
OPERATING DATA REl' ORT
~
DOCKET NO. 50-247 DATE 2-5-86 COMPLETr.D I1Y K - WHaner
'.i TELEPil0NE 41A W -5155 OPERATING STATUS Indian Toint UNIT No. 2 Notes
- 1. Unit Name:
January 1986
~
- 2. Reporting Period:
2758
- 3. Licensed Thermal Power (MWI):
- 4. Nameplate Rating (Gross MWe):
1013 I
- 5. Design Electrical Rating (Net MWe):
R71~
400
~
h
- 6. Maximum Dependable Capacity (Cross MWe):
R64 j.,
7., Maximum Dependable Capacity (Net MWe):
- 8. If Changes Occur in Capacity Ratings (!! cms Number 3 Through 7) Since Last Report.Give Reasons:
1 s
b.I
.r.
y e
-. _,.u n.
n
.._.,c,.
u;
- 9. Power Letel To khich Restricted.lf Any (Net MWe):
- -f
- 10. Reasons For Restrictions.If Any:
i-If d
e s
f!;
--J N MonthE-u[Yr. to Date -h$ ' Cusablive..
- 1 y
a h.. 7 4 4 --
101593-
,.y
-744
~,
.f II. Hours In Reporting Period 3
- 12. Number of Hours Reactor Was Critical 300.55 300.55 69470.41 3
- 13. Reactor Resene Shutdown Hours 0
0 114R 17 ti
- 14. Hours Cenerator on l.ine 295.13- -
295.11 67411_n1
- 15. Urdt Reserve Shutdown Hours 0
O n
~
- 16. Gross Thermal Energy Generated (MWH) 799337 799337 17512,5S 1,
- 17. Gross Electrical Energy Generated (MWH) 252760,_,
252760 9440??16 4
- 18. Net Electrical Energy Generated (MWH) 241095 241095 92020081 39.7 39.~7 =-
-66.4 Id
- 19. Unit Senice Factor 39.7 f
-39 07 ~
66.4 m -
~
I
- 20. Unit Availability Factor N
- 21. Unit Capacity FactorIUsing MDC Net)
~
37.5 37.5 59.~6 ~
- 22. Unit Capacity Faetor IUning DER Net)
~17 1
~ ~~
37 1 9R 7
~
j
- 23. Unit Forced Outage Rate 4.3 4.3'~
8.9
4. Shutdowns Scheduled Oier Next 6 Months (Type.Date,and Duration of Eacht:
1 j
Cycle 7/8 refueling and maintenance outage in Pr5aress.
j 6
3
- 25. If Shut Down At Eiid Of Report Period. Estimated Date of Startup:
Marbh 13'.
1996 i
- 26. Units la Test Statu> lPrior in Commercial Operationi:
Forecast Achieved ai g_
INITIAL CRITICALITY
]'s INITIAL. El.FCTRICI TY COMMI RCIAL Ol'Fl( ATION ei 9%.
i 8602250000 860131 PDR ADOCK 05000247 g
(,8/77)
,4 R
PDR t
v,--
,+--r e--==-+
wr v-----e'.--er+
v ir v-- - - - - ~ - '
-w1*F--^*-^f""*-^*-=-*t'---'"'--+"^"-**'rPT--~"-'-*"'"-t'*'-se-~e-&--w w-e 1
- ewe--'-*-te-**--w*----'"'
- -****e-'
AVERAGE DAILY UNIT' POWER LEVEL DOCKET NO.
50-247 i'
I.P. Unit 2 UNIT 4
2-5-86' DATE COMPLETED 8Y K. Krieger 914-526-5155 TELEPHONE MONTy January 1986 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 160 17 0
2 820 0
is 3
849 0
19 4
838 0
20 5
849 0
21 848 6
0 22 849 7
3 848 g
0 24 9
846 0
25 10 847 26 0
11 848 0
27 12 845 0
28 13 704 29 0
14 0
0 30 15 o
0 31 16 0
INSTRUCT 10NS j
On this format, list the average daily unit power levelin MWe-Net for each day in the reporting month. Compute to "
the nearest whole megawatt.
(9/77) i
i 4
DOCKET NO. _50-24 7 UNIT SilUTDOWNS AND POWER REDilCTIONS UNIT N A\\lE J.P.
fini t 7 DATE
>-9-96 COMPLETED BY K.
Vrfecer REPORT MOTw'Tsilinu a ry 19_86 TELEPilONE (9141576-M1M5
'i 4
t E
E 4
,[ g
'h jYh Licensee
,E c, h
Cause & Curreceive W.
. Date h
Eg
.E sE Event M
Q-Action to P-y I,,,
j ;?, g Report 8' v: O Present Recurrence g
6 13 851231 F
13.33 A
3 85-017 CJ Valve Papid rate of change of A
pressurizer pressure.
1 860113 S
4.35.54 C
3 86-001
.CH Pumpxx 21 MBFP tripped which began.
B cycle 7/8 refueling outage.
s l
I 2
37 4
F: Feweed Reamn:
Metha t Ezhibit G. Instructions 5: Scheduled A l'iiuipment Failure (Explain)
I Man a for Pseparation i.I Data B4taintenance of Test
- 2 ManualScram.
Entr> Sheets for Licensee C. Refueling 3-Automatic Scrane.
Event Report (LERI File (NUREG.
f 4-Other (Explain) c 0161)
D Regulatory Restriction ~
E-Operator Training & Ucense Examination F-Administrative 5
Exh@is I-Same Source G-Operational Error (Explain) r8/77) ll Osher(Explain)
)
> a
- : e-,. 3. r. - g..... n.
a. : m e..
. n. <.c_...m.
e
l Summary of Operating Experience January 1986 Unit No. 2 returned to full power operation on January 2 following a reactor trip on December 31, 1985.
With the exception of two brief load reductions to approximately 93% reactor power due to turbine runbacks, the Unit operated at essentially full power until January 13.
On January 13, a reactor trip occurred as a result of the loss of No. 21 main boiler feedwater pump. Since the Unit was scheduled to start a refueling and maintenance outage the following day, it was decided to start the outage one day earlier than planned.
At the end of the month, unloading of the reactor core had been completed and change out of the fuel assembly " inserts" in the fuel storage pool was underway.
i i
i i
'e-F Major Safety Relative Corrective Maintenance kORK ORDER #
SYSTBt COMPONENT DATE WORK PERFORMED' 84-16154-ELEC BFD RELAYS 1/30/86-REPIACE RELAYS 84-16156 84-16394 84-16396 4
4 1
s m
m.
. i
.E m
a l
E
' John D. O'Toole -
Pce Pres, dent Consohdated Ecison Company of New York.. Inc.
4 trving Place, New York, NY 10003 Telephone (212) 460-2533 February-18, 1986
/
Re:
Indian Point Unit No. 2 Docket No. 50-247 Mr. James M. Taylor, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 ATIN:
Document Control Desk
Dear Sir:
Enclosed are twelve copies of the Monthly Operating Report for Indian Point Unit No. 2 for the month of January 1986.
Ve truly yours, i
fnv.'
WVb' enc 1.
cc:
Dr. Thomas E. Murley, Regional Administrator Region I U. S. Nuclear Regulatory Commission 631 Park Avenue
-l King of Prussia, Pa.
19406 1
Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 38 i
Buchanan, New York 10511 hl I It i
4