MONTHYEARML20248B2371998-03-31031 March 1998 Revised Monthly Operating Rept for March 1998 for Indian Point Station Unit 2 ML20029C7801994-03-31031 March 1994 Monthly Operating Rept for Mar 1994 for Indian Point Unit 1. W/940415 Ltr ML20247G5171989-04-30030 April 1989 Monthly Maint Category I Rept Pages from Monthly Operating Rept for Apr 1989 for Indian Point ML20154M5661988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Indian Point Station Unit 2 ML20154M5691988-07-31031 July 1988 Revised Page to Monthly Operating Rept for Jul 1988 for Indian Point Station Unit 2 ML20236P9861987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235Y9681987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20236A5811987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20234D7771987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20237J6511987-07-31031 July 1987 Monthly Operating Rept for Jul 1987 ML20235U7571987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML20215F3711987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20214H5111987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20214E9541987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20206Q6951987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20206R6201987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20207T1321987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20207R6861987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20206R6451987-02-28028 February 1987 Revised Monthly Operating Rept for Feb 1987 ML20211E1381987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20211J1481987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20212P8891986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20207P9801986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20215E8501986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20211Q0501986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20212L9131986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20214D0211986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20203P1081986-09-30030 September 1986 Monthly Operating Rept for Sept 1986 ML20209J0801986-08-31031 August 1986 Monthly Operating Rept for Aug 1986 ML20214K4281986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20207C3021986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20207C3171986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20211F7351986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20198A2731986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20205P6911986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20141E6071986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20141E6121986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20140B8481986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20154P0171986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20141D2331986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20153E3491986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20140B8541986-01-31031 January 1986 Rev I to Monthly Operating Rept for Jan 1986 ML20140A8211985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20141J1861985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20138P4981985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20138M5941985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20136E8811985-10-31031 October 1985 Monthly Operating Rept for Oct 1985 ML20138J7921985-09-30030 September 1985 Monthly Operating Rept for Sept 1985 ML20205C7241985-08-31031 August 1985 Monthly Operating Rept for Aug 1985 ML20134F6881985-07-31031 July 1985 Monthly Operating Rept for Jul 1985 1998-03-31
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217H8501999-10-14014 October 1999 Safety Evaluation Supporting Amend 197 to License DPR-64 ML20206U2551999-02-0909 February 1999 Safety Evaluation Supporting Amend 187 to License DPR-64 ML20236Y1571998-08-0303 August 1998 Part 21 Rept Re ASTM A351,GR. CF8 Matl at Indian Point Being Out of Specifications in Molybdenum & Chromium.Cause & Corrective Actions Are Not Stated ML20236V4281998-07-13013 July 1998 Safety Evaluation of TRs WCAP-14333P & WCAP-14334NP, PRA of RPS & ESFAS Test Times & Completion Times. Repts Acceptable ML20236T5511998-06-24024 June 1998 Consolidated Edison Co of Ny,Indian Point Unit 2,Drill Scenario Number 1998C ML20248B2371998-03-31031 March 1998 Revised Monthly Operating Rept for March 1998 for Indian Point Station Unit 2 ML17264A9381997-07-10010 July 1997 Deficiency Rept Re Potential Safety Hazard Associated w/FM-Alco 251 Engin,High Pressure Fuel tube-catalog: 4401031-2 in Which Dual Failure Mode Exists.Caused by Incorrect Forming Process ML18153A1431997-06-10010 June 1997 Part 21 Rept Re Possible Machining Defect in Certain Stainless Steel Swagelok Tube Fitting Bodies.Facilities Have Been Notified About Possible Problem ML20210E3591997-03-27027 March 1997 Part 21 Rept Re Sorrento Electronics Inc Has Determined Operation & Maint Manual May Not Adequately Define Requirements for Performing Periodic Surveillance of SR Applications.Caused by Hardware Failures.Revised RM-23A ML1005008001997-02-28028 February 1997 Conditional Extension of Rod Misalignment TS for Indian Point 3. ML20115J3981996-07-22022 July 1996 Interim Part 21 Rept Re 3/4 Schedule 80 Pipe Furnished to Consolidated Power Supply.Investigation Revealed Only One Nuclear Customer Involved in Sale of Matl ML20096E5101995-12-31031 December 1995 Resubmitted Rev 13 to QA Program ML17059A3611994-07-0606 July 1994 Emergency Action Level Verification & Validation Rept. ML17311A0181994-05-13013 May 1994 New York State EAL Upgrade Project Verification & Validation Rept. ML20029C7801994-03-31031 March 1994 Monthly Operating Rept for Mar 1994 for Indian Point Unit 1. W/940415 Ltr ML20056E5171993-08-31031 August 1993 Technical Review Rept, Tardy Licensee Actions ML20062J2281993-07-23023 July 1993 Consolidated Edison Co of Ny Indian Point Unit 2,Drill Scenario 1993 ML20118A2681992-12-31031 December 1992 Consolidated Edison Co of Ny Indian Point,Unit 2 Exercise Scenario,1992 ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20127P5861992-11-23023 November 1992 Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl ML20096H2301992-05-21021 May 1992 Special Rept:On 920504,south Side Lower Electrical Tunnel Detection Sys 8 Taken Out of Svc for Mod to Reposition Detection Sys Run of Conduit.Detection Sys Declared Operable on 920520 After Mod Completed & Sys Retested ML20079F9181991-05-31031 May 1991 Structural Evaluation of Indian Point,Units 2 & 3 Pressurizer Surge Lines,Considering Effects of Thermal Stratification ML20059E9461990-08-31031 August 1990 Nonproprietary Rev 2 to Indian Point 2 Tube Fatigue Reevaluation ML20059G2011990-07-31031 July 1990 Final Rept on Steam Generator Insp, Repair & Restoration Efforts During 1990 Midcycle Insp ML20058K4151990-06-30030 June 1990 Steam Generator Insp,Repair & Restoration Program Presentation to Nrc ML20058K4121990-06-30030 June 1990 Status Rept,Indian Point Unit 2 Mid-Cycle Steam Generator Insp Presentation to Nrc ML20043A4891990-05-30030 May 1990 Nonproprietary Indian Point Unit 2 Steam Generator Insp, Repair & Restoration Program. ML20042F1441989-12-31031 December 1989 New York Power Authority Annual Rept for 1989. W/900430 Ltr ML19332B9371989-11-30030 November 1989 Nonproprietary Info Presented to NRC Re Indian Point Unit 2 Steam Generator Secondary Side Loose Objects. ML19332D6661989-10-31031 October 1989 Nonproprietary Rev 2 to Indian Point Unit 2 Steam Generator Girth Weld/Feedwater Nozzles Rept Spring,1989 Outage. ML20247J8161989-07-31031 July 1989 Safety Evaluation for UHS Temp Increase to 95 F at Indian Point Unit 3 ML20248B3171989-06-30030 June 1989 Rev 1 to Nonproprietary WCAP-12294, Indian Point Unit 2 Steam Generator Girth Weld/Feedwater Nozzles Rept,Spring 1989 Outage ML20248D3631989-06-30030 June 1989 Rev 1,to Indian Point Unit 3 Reactor Vessel Fluence & Ref Temp PTS Evaluations ML20247N5331989-05-31031 May 1989 Nonproprietary Indian Point Unit 2 Steam Generator Girth Weld/Feedwater Nozzles Rept Spring,1989 Outage ML20247J8071989-05-31031 May 1989 Containment Margin Improvement Analysis for Indian Point Unit 3 ML20247G5171989-04-30030 April 1989 Monthly Maint Category I Rept Pages from Monthly Operating Rept for Apr 1989 for Indian Point ML20244C3311989-04-10010 April 1989 Safety Evaluation Supporting Amend 137 to License DPR-26 ML20248F4211989-03-31031 March 1989 NSSS Stretch Rating-3,083.4 Mwt Licensing Rept ML20235V5931989-03-0202 March 1989 Special Rept:During Cycle 6/7 Refueling Outage Scheduled from Feb-May 1989,openings Will Be Made in Plant Penetration Fire Barriers in Order to Install Various Mods. Fire Watches Posted & Fire Detection Tests Completed ML20248F3001988-12-31031 December 1988 10CFR50.59(b) Rept of Changes,Tests & Experiments Completed in 1988 ML20246E2711988-12-31031 December 1988 Con Edison 1988 Annual Rept ML20196D3011988-10-31031 October 1988 Reactor Vessel Matl Surveillance Program for Indian Point Unit 2 Analysis of Capsule V ML20155H2541988-09-30030 September 1988 Rev 2 to Indian Point Unit 2 (NRC Bulletin 88-008 Thermal Stresses in Piping Connected to RCS) Indentification of Unisolable Piping & Determination of Insp Locations ML20154M5661988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Indian Point Station Unit 2 ML20154M5691988-07-31031 July 1988 Revised Page to Monthly Operating Rept for Jul 1988 for Indian Point Station Unit 2 ML20151N7881988-07-31031 July 1988 Rev 1 to Charpy Toughness & Brittle Transition Temp Characterization of HAZ High Hardness Zone of Indian Point Unit 2 Steam Generator Girth Weld by Gleeble Weld Thermal Cycle Simulation ML20006B4741988-05-31031 May 1988 Nonproprietary Indian Point Unit 2 Evaluation for Tube Vibration Induced Fatigue. ML20151N7821988-05-31031 May 1988 Fracture Sensitivity Study of Girth Weld 6 Repaired Configuration,Indian Point Unit 2 ML20153F9161988-04-28028 April 1988 Changes,Tests & Experiments - 1986 ML20151T4681988-01-31031 January 1988 Experimental & Finite Element Evaluation of Spent Fuel Rack Damping & Stiffness 1999-02-09
[Table view] |
Text
. . .
M OPERATING DATA REPORT U
' DOCKET NO.
50-247 DATE 2-6-84 COMPLETi:D IlY M - nine*
TELEPilONE f914) 06-2127 i
A b OPERATING STATUS ,
Notes
' l. Unit Name: -'.Tndian Poi n t ' Un i t #2
-January 1984
- 2. Reporting Pernd:
2700 ,
- 3. Licensed Thermal Power (MWt):
- 4. Nameplate Ratin;IGros, SfWe): 1013' -
873
- 5. Design Electrical Rating (Net MWe):
900 ,
6._ Maximum Dependable Capacyy (Gross MWe): 864 ,
- 7. Mnimum Dependable Capacity (Net MWe):
- 8. If Changes Occur in Capacity Ratings (Items Num! er 3 Through 7) Since Last Report. Give Reasons:
y.
None
?. Pov er Lesel To which Restricted. lf Any (Net MWe):
None
- 10. Reasons For Restrictions. lf Any: None
~
E Month Yr o.Date Cumulative 744 744 84049
' II. Hours in Reporting heriod 56639.05 12.- Number Of flem, Reactor Was critical 691.83 691.83_
0 0 2119.73
+- 13. Reactor Resene Shutdown Hours 679.73 54875.43
- 14. Hours Generator On Lin, 679.73 0 0 0
- 15. Unit Resene Shutdown Hours -142 R67 694 -
- 16. Gross Thermal Energy Generated (MWil) 1 826 795 1 926 795 4
574__460 , 574 460 44 232 036
.17. Gross Electrical Energy Generated (MWH) 551 346 551 346 42 178 438
- 18. Net Electrical Energy Generated (MWH) 65.3 91.4 91.4 1 19. Unit Senice Factor _ -
91.4 91.4 65.3
- 20. Unit AssilabiNty Factor 85.8 85.8 58.4
- 21. Unit Capacity Faetor IUsin;MDC Net) ' ' 84.9 57.5 84.9
'22. Unit Capacity Faetor IUning DER Net) 8.6 9.2 8.6 h 7 23_. Unit Forced Outage Rate
[24. Shutdowni Seheduled Oser best 6 Months IType. Date,and Duration of Each t:
10 veer In Service Insoection/Refuelino Outace Scheduled to Becin May 15, 1984.
- 25. If Shut Down At End Of Repott Period. Estimated Date of Startup:
N/A
- 26. Units in Test Status tPrior eo Conunercial Operationt- Forecast Achiesed N/A N/A .
i.
INITIAL CR111CALITY "
INITI \1. Fl.I'Cl RICI fY " "
COMill'RCIA1. Orl'RA IION (9/77) g O j.7 PDg
s
, s. . ,, 5.
AVFRAGL DTILY (;NIf Powl:R LLVI;L ,
DOCKET NO. 50-?f7 - . , +
4 UNIT _JN7I fi11t #$'
DATE. '2/6/6,.'_ .
COMPLETED fly M_ nlatt __
,t TELEPilONE (914) 526-51$7 .,
MONTH January 1984 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL, (Mhe-Net) (MWe-Net) 1 853 37 g37 2 852 33 __
842 3 691 839 39 4-849 835 20 718 838 i 5 21 0 837 6 22 0 838 7 23 s 192 24 835 9 825 35 835.
a
^
10 828 ' -
836c -s gg 840 4, 1 i". 663
. s ' ~. 27.. s 841 665 1, . sg , ~
~
833 .) ~ . _- 834 a -- _ . L , n,.~ ^
v 823 833 Q 34 3 _%. .
30 .x "
15 840 _ ,
31 834 % s.
840 J'
g c.
l' v.,
.;. n ), ^ ~
~ .-
s ,.- ,y .
s . .,
~, '
%' - s t't.. ) it: nit.. eet.ps . * * * . . ., * :'. .
!,6 737 3sy,, g; -R3;s f ,; %.,, .g..
, s,
- Y
.a * , s ', .,,y,* . ,, , ,
" ' ' ~ , ,
< . +~ p , ~ + -
9 s .ge-d' 3m, p .
> I "y
,e ,. ,x _
f ,, ~, q ,
M i s --* W . Tra,,. *
< 3 L
. ... Q'
_4' '
ht
s ' + , .' .y ,s
,'A d, ,
^
- 4
'% ww ., ,. ,.
, + s .~
+ . s ~
.= % ,%."*
s w-A' % . l
,W # -
m -Y
~
,, ~.3, %
% 4 m _.3 N * ,
7 g' .sm % - y - g
, =
b g
~ g,. -
,' N, -, ,.
g
u _, .",g, ,
j- ;[ c 4 .
1/ . .. ./ ^3 g's
\h
~ ,a
' DOCKET FO. 24 7 e .s ,
UNITSilUTDOWNS AND POWER REDUCTIONS IP - Unit if 2 UNIT NAME DATE ?/6/Ad COMPLETED BY M_ B 1 a t+ -
' REPORT MONTH January'1984 TELEPHONE f91a1 E? A_c127-l a n s, 3w= . _ E
.E _e .g S X Licensee ugr,.2 c"L3 Cause & Corrective No. Date F 3g g ,3gg Event Action to
$5 5 Repost # 'N0 E.b
! Present Recitrrence 3
e dj =! u 6
Pump xx Controlled load reduction to N/A 01/03/84 S N/A B N/A N/A .CH B repair Main Boiler Feed-Pump Control Oil System.
4 _____ ______.____ _ _ _ _ .___________.______ _ _ _ _ _ _;_ _ _ _.. _____ ________ ,_______________________________
Valve x Containment Isolation purge i 1 01/0$/84 F 64.27 D 2 84-01 SD B exhaust val.e repairs.
Instru. Controlled load reduction due N/A 01/27/84 F N/A D N/A N/A IB I to inoperability of Control Rod Position Indication Sys_
tem.
],
l 1 2 3 4 l F: FereJ Reasos;; Method: Ex!nbit G - Instructions S: SchedulcJ A 1:quipment Failure (Explain) 1-Manual for Pseparation of Data B Maintenana or Test 2-Manual Scram. Entry Sheets fur Licensee C-Refueling 3- Automatic Scram. Event Report tLERI File (NUREG-D-Regulatory Restriction 4 Other (Explain) 0161)
F-Operator Training & License Examinatitm F Administrative 5 4
G Operational Error (Explain) Exhrbit I- Same Source (d!77) ll-Other (Explain) 4
.. i i
+
[
Summary of Operating Experience t
. January 1984 ,
U3 it 2 operated at 100% reactor power at the beginning of the report period. During the month several small power reductions occurred for
. preventive and corrective maintenance.
On January .j 3, reactor power was reduced to 68% to conduct preventive maintenance.on a main boiler feed pump.
On January 5, the reactor was brought to hot shutdown due to excessive air. leakage from the Weld channel and Containment Penetration Pressurization System. The cause of - the excessive leakage was corrected and the reactor returned to 100% power on January 7.
On January 10, reactor power was reduced to S3% while securing a condensate pump for corrective maintenance.
.On January 13, reactor power was reduced to 98% to plug a leaking condenser tube.
During the period from January 19 through January 20, power reactor was
- reduced to 98% on three occasions while main circulating. water pumps were temoved from service to allow inspection of the circulating water intake structures.
On January 27,.s controlled power reduction to' hot shutdown was commenced i due to apparent inaccuracies in the Rod Position Indication (RPI)
Systen. The shutdown was terminated at a reactor power of 17% when new
- rod position calibration curves indicated that the RPI System was satisfactory. The reactor was returned to 100%~ power and remained there for the rest of the month.
w .
I 2
O m
.s-
'V e
MAJOR' SAFETY RELATED'CORRECTIV_E MAINTENANCE
- MWR NO. DATE COMPONENT SYSTEM CORRECTIVE ACTION 10179 12-2-83 NIS CH 42 . NI S .
- ADJUSTED ISOLATION AMPLIFIER-t
. 11165 11-21-83 BORIC ACID BAHT MAINTENANCE REINSTALLED ~
HEAT TRACE THERMOCOUPLES CKT 29 i
11202 11-25-83 BORIC ACID BAHT MAINTENANCE TO REPLACE HEAT I HEAT TRACE 46B TRACE
- 10483 11-21-83 BORIC ACID HEAT BAHT REPLACED DEFECTIVE TRIAC TRACE CIRCUIT 6
~,.
11136 11-21-83 BORIC ACID HEAT BAHT- -
REPLACED CONTROLLER AND TRACE CIRCUIT 23 ALARM MOL'ULES 11140 11-29-83 BORIC ACID HEAT BAHT REPLACED CONTROLLER TRACE CIRCUIT 48B, 49B I 11215 11-25-83 24 STATIC IN- ELEC REPLACED BIDWN OUTPUT FUSES j VERTER 11138 11-30-83 BORIC ACID HEAT BAHT REPLACED DEFECTIVE TRIAC AND TRACE CIRCUIT 47 AND CCNTROLLER i
10480 11-29-83 ' BORIC ACID HEAT BART REPLACED DEFECTIVE BOARD IN
- CIRCUIT 54 ALARM MODULE i-19861 11-2-83 AIR IDCK AREA RAD RM FOUND BROKEN PIN IN
- MONITOR R-2 DETECTOR & PIGTAIL CON-NEC70R, REPLACED BULKHEAD CONNECTOR T
h 1
4
-l n John D. O'Toob
' *t Vee Prescent Conschdated Edison Ccepany of New York. Inc.
4 trying P! ace, New York, NY 10033 Telephone (212) 460-2533 February 15, 1984 Re : - Indian Point Unit No. 2 Docket No. 50-247 Mr. William G. Mcdonald, Director.
Office of Management Information and Program Control c/o Distribution Servaces Branch, DDC, ADM Washington, D. C. 20555
Dear Mr. Mcdonald:
Enclosed you will find two copies of the Monthly Operating Report for Indian Point Unit No. 2 for the month of January 1984.
Vety ruly yours, YY Encl.
cc Mr. Richard DeYoung. Director (40 copies)
Office of Inspection and Enforcement c/o Distribution Services Branch, DDC, ADM U. S. Nuclear Regulatory Connaission Washington, D. C. 20555 Dr. Thomas E. Murley, Regional Administrator Region I U. S. ' Nuclear Regulatory Connaiscion 631 Park Avenue King of Prussia, Pa. 19406 Mr. Thomas Foley, Senior Resident Inspector