Insp Rept 50-261/90-25 on 901105-08.No Violations Noted. Major Areas Inspected:Occupational Radiation Safety During Extended Outages,Audits & Appraisals,Planning & Preparation, Training & Qualification & External Exposure Control
ML14178A064
Person / Time
Site: Robinson 
Issue date: 11/29/1990
From: Gloersen W, Kuzo G, Potter J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML14178A062 List:
References
50-261-90-25, NUDOCS 9012170108
Download: ML14178A064 (20)


Text

S REG UNITED STATES o

NUCLEAR REGULATORY COMMISSION C

a

REGION II

101 MARIETTA STREET, ATLANTA, GEORGIA 30323 NOV 3 0 %

Report No.:

50-261/90-25 Licensee:

Carolina Power and Light Company P.O. Box 1551 Raleigh, NC 27602 Docket No.:

50-261 License No.:

DPR-23 Facility Name:

H. B. Robinson Inspection Conducted:

November 5-8, 1990 Inspectors:

) Gloersen Date Signed G. B. Kuzo Date Signed Accompanying Personnel:

E. B. Pharr Approved by:

4 2 z

J. P. Potter, Chief Date Signed SFacilities Radiation Protection Section Radiological Protection and Emergency Preparedness Branch Division of Radiation Safety and Safeguards SUMMARY Scope:

This routine, unannounced inspection was conducted in the area of occupational radiation safety during extended outages and included an examination of:

audits and appraisals, planning and preparation, training and qualification, external exposure control, internal exposure control, control of radioactive materials and contamination, surveys and monitoring, and maintaining occupational exposures ALAR In addition, Information Notices and the licensee response to a previously identified inspection finding were reviewe Results:

In the areas inspected, three non-cited violations and one unresolved item were identifie Based on interviews with licensee management, supervision, technicians, and records review, the inspectors found the radiation protection program to be managed adequatel The licensee's programs for external and internal radiation exposure controls were effective and functioning adequately to protect the health and safety of occupational radiation worker Contractor 9012170108 901130 PDR ADOCK 05000261 Q

PDR

health physics employee training and qualifications met applicable requirement However, weaknesses were noted and were identified as non-cited violations in the following areas: (1) failure to barricade an entrance to a high radiation area (licensee-identified) (Paragraph 3);

(2) failure to follow procedures (Paragraph 7.c); and (3) failure to label properly storage containers for radioactive materials (Paragraph 9.b).

Additionally, an unresolved item concerning the adequacy of verification of Grade D quality for the supplied-air system was identified (Paragraph 6.b).

REPORT DETAILS 1. Persons Contacted Licensee Employees S. Billings, Technical Aid-Regulatory Compliance M. Burch, Radiation Control Foreman - Environmental and Radiological Control (E&RC)

C. Coffman, Project Engineer - Onsite Nuclear Safety R. Crook, Senior Specialist-Regulatory Compliance

  • Curley, Manager -

E&RC

  • C. Dietz, Manager -

RNPD

  • A. Eaddy, Support Supervisor -

E&RC

  • K. Kirkland, Senior Specialist -

E&RC

  • Kloosterman, Director -

Regulatory Compliance T. Pilo, ALARA Specialist -

E&RC

  • W. Ritchie, Senior Specialist -

E&RC

  • J. Sheppard, Plant General Manager Other licensee employees contacted included radiation control foremen, technicians, supervisors, and office personne Nuclear Regulatory Commission L. Garner, Senior Resident Inspector
  • K. Jury, Resident Inspector
  • Attended exit interview 2. Organization and Management Controls (83750)

The inspectors reviewed changes made to the licensee's organization, staffing levels, and lines of authority as they related to radiation protection, and verified that there were no significant changes made to the licensee's organization or program since the last inspectio The inspectors discussed with the radiation protection supervisor the type, methods of, and degree of interaction between plant group The inspector reviewed the licensee's program for self-identification of weaknesses related to the radiation protection program and the appropriateness of corrective action taken. This subject is discussed further in Paragraph No violations or deviations were identifie. Audits and Appraisals (83750)

Technical Specification (TS) 6.5.3.2.d requires that audits of plant activities be performed under the cognizance of the Quality Assurance (QA)

Services Section of the Corporate QA Department and that the audits shall

encompass, in part, the following:-(a) the conformance of facility operation to all provisions contained within the TSs and applicable license conditions at least once per 12 months; and, (b) the Process Control Program (PCP)

and implementing procedures for solidification of radioactive wastes at least once per 24 month The inspectors reviewed the following audits of the Environmental and Radiation Control Program:

Audit Report No.: QAA/0020-89-01 (conducted February 20-March 3, 1989)

Audit Report No.: QAA/0020-90-02 (conducted February 5-16, 1990)

In general, the audits were found to be well planned and documented and contained items of substance relating to the radwaste, radiological protection, monitoring, dosimetry, control, testing, and ALARA program The reports of audit findings to management also were reviewed and were found to contain responsive commitments by management to effect corrective actions for the deficiencies note The inspectors also reviewed the experience of the licensee in identifying and correcting deficiencies or weaknesses related to the control of radiation or radioactive material. The licensee used the following vehicles to identify and document radiological control weaknesses: radiation safety violations (RSVs),

significant condition reports (SCRs),

nonconformance reports (NCRs), and QA field report The inspectors reviewed RSVs for 1990 and observed that RSVs were neither sequenced nor tracked by severity level or root caus The RSVs were apparently tracked by Department and the information was supplied in the monthly E&RC reports to managemen If the licensee noted several similar RSVs, then an SCR normally would be written. The inspectors discussed this type of-tracking system for RSV Licensee representatives stated that they would evaluate the tracking system for changes that might enhance the program for self-identification and correctio One apparent problem area was identified by the licensee involving two examples for failure to barricade an entrance to a high radiation area located at the Pipe Alley in the Auxiliary Building in accordance with TS 6.1 The first event occurred on November 25, 1989, and involved both a posting and barricading problem while the second event occurred on August 17, 1990, and involved only a barricading problem. Both cases involved the physical barrier to the Pipe Alley being left dow As part of the corrective action to prevent recurrence of the first event, the licensee submitted a request to install a door to control access to the Pipe Alle After an engineering evaluation was performed, the door proposal was unacceptable due to fire protection concerns. The licensee then submitted a request to install a swing gat The ensuing engineering evaluation required a significant amount of time since the swing gate was to be installed into a seismic wal Before the swing gate was installed, the second event occurred on August 17, 1990 (as noted above).

The inspectors

-informed the licensee that this problem area would be identified as a violation of TS 6.13.1, however this licensee-identified violation would not be cited because the criteria specified in Section V.G.1 of the NRC Enforcement Policy were satisfie This violation was considered to be a non-cited violation (NCV) since the licensee's corrective action to prevent recurrence of the first event had not been implemented before the second event occurred due to engineering evaluation delays (NCV: 50-261/90-25-01).

One NCV for failure to barricade a high radiation area in accordance with TS 6.13.1 was identifie.

Planning and Preparation (83750)

The inspectors reviewed the licensee's augmentation of the health physics (HP) staff to support the H. B. Robinson thirteenth refueling (RF13) outag The licensee had requested and ultimately hired 83 contractor health physics technicians (HPTs) to supplement the permanent staff of 31 Radiation Control Technicians (RCTs).

The contractor HP staff consisted of 55 senior technicians, 25 junior technicians, and 3 supervisor The licensee assigned a permanent HP Foreman with each contract supervisor to work as a team during the entire outag During the RF13 outage, the licensee estimated a ratio of one HPT to 16 outage worker The inspectors also examined indicators of management support for the radiation protection progra The following approvals of budgeted items needed for radiation protection during the outage and future outages were noted:

o Authorization of an additional 25 HPTs to support RF13 o

Authorization for additional temporary shielding purchases o

Approval to decontaminate the RHR system o

Authorization to order three tool monitors

,

Authorization to order approximately 100 digital alarming dosimeters No violations or deviations were identifie. Training and Qualifications (83750)

10 CFR 19.12 requires the licensee to instruct all individuals working or frequenting any portions of the restricted areas in the health protection aspects associated with exposure to radioactive material or radiation, in precautions or procedures to minimize exposure, and in the purpose and function of protection devices employed, applicable provisions of the Commission Regulations, individuals responsibilities and the availability of radiation exposure dat General Employee Training (GET) provided to craftsmen as well as to licensee and contract HP technicians was reviewed and discussed with licensee representative a. General Employee Training (GET)

Training Instruction-300 (TI), General Employee Training and Respiratory Protection Training, Revision (Rev.)

24, dated June 26, 1990, describes a program in which facility employees were provided with general knowledge and skills for safe work in and around the plan GET is divided into two levels with GET I providing a general plant indoctrination while GET II, is required for employees entering the Radiologically Controlled Area (RCA).

GET requalification was required annuall From review of training procedures and course outlines, and discussions with training personnel, the inspectors noted that the program met the provisions of 10 CFR 19.1 In addition the training program was thorough and well-organized. Trainees were taught exposure reduction techniques, ALARA concepts, and hazards associated with radiation exposur Students were required to pass the GET exam with a minimum of 80 percent correct. Also a demonstration of profficiency in a full dress mock-up of entering and exiting a contaminated area was require The mock-up exercise required complete and correct donning and removing of protective clothing, as well as demonstration of safe radiation protection practice The inspectors reviewed selected GET records for workers signed in on Radiation Work Permits (RWPs)

R90-660, and R90-0786, both dated on November 2, 199 The RWPs were associated with steam generator (S/G)

activitie Records. were reviewed using the licensee's Radiological Information Management System (RIMS).

For the individuals reviewed, all GET was curren No violations or deviations were identifie HP Technician Training TI-114, Related Technical Training and On-the-job Training for Environmental and Chemistry and Radiation Control Personnel, Re,

dated May 21, 1990, provided for the initial and a continuous training program for RCTs and also for their pending qualificatio Licensee technicians are provided initially with a three to four week generic HP training program and after successful completion are given site specific trainin As part of their on-the-job training, technicians are required to complete selected tasks documented on qualification card Also within three years of their start date, technicians are required to complete a five week plant systems sessio Licensee RCTs were provided with quarterly specialized trainin The training department representatives stated that quarterly specific system classes are planned for the beginning of 199 Contract HPTs were required to complete successfully a two to three day site-specific training and to complete qualification cards as part.of their on-the-job training. Both junior and senior technicians required the same initial training but advanced training was available to only senior technician Selected qualification cards were reviewed for both in-house and contract technicians and all records of training activities were found to be appropriately completed or in progres No violations or deviations were identifie. Respiratory Protection Program (83750)

10 CFR 20.103(c)(2) permits the licensee to maintain and to implement a respiratory protective program that includes, at a minimum:

air sampling to identify the hazard; surveys and bioassays to evaluate the actual exposures; written procedures regarding supervision and training of personnel, and issuance of records; and determination by a physician prior to initial use of respirators, and at least every 12 months thereafter, that the individual user is physically able to use respiratory protective equipmen a. Training, Fit Testing and Medical Qualifications The inspectors reviewed and discussed the respirator protection program training, fit-testing, and medical qualification status for selected personnel using particulate and/or supplied-air respiratory protective equipment at the facilit TI-300, General Employee Training and Respiratory Protection Training, Re,

dated June 26, 1990, provided required training to prepare workers to wear respirators for protection against radiological and nonradiological contaminant Health Physics Procedure (HPP)-101, Administrative Control for Respirators, Rev. 12, dated July 21, 1989, required that the licensee maintain in good operating condition an adequate supply of respirators ready for issue at any tim HPP-101, Section 9.1 stated that respirators will not be issued to an individual unless he/she had been medically qualified, respirator trained or retrained, and successfully fit-tested per HPP-102, Respirator Fit Testing, within the past 15 month The inspectors noted that the length of time between medical qualifications were contrary to the regulations of 10 CFR 20.103(c)(2)

which require annual medical qualification Licensee representatives informed the inspectors that an exemption from the requirement was granted to H.B. Robinson by the NRC as detailed in a memo dated July 29, 1989. The exemption permitted the licensee to administer physical examinations for users of respiratory equipment at an interval of every 9 to 15 months rather than the currently schedulded 8 to 12 months, provided that the total time over any three consecutive physical exam periods did not exceed 39 month The inspectors noted that the licensee's procedure only required that respirator users be medically examined within 15 months

of respirator us Therefore, by following the current procedure, an employee could exceed the 39 month time interval granted by the NRC's exemption over three consecutive exam period Licensee representatives stated they would consider potentially revising the procedure to assure that no individual could exceed the 39 month time interva Review of selected records on the licensee's RIMS indicated that selected contractor and licensee employees conducting S/G work associated with RWPs R90-660 and R90-0786 were trained to use respiratory protective equipment, fit-tested, and medically qualified in accordance with procedural requirement No violations or deviations were identifie b. Breathing Air Quality 30 CFR 11.121 requires that compressed, gaseous breathing air meet the applicable minimum grade requirements for Type 1 gaseous air set forth in the Compressed Gas Association (CGA)

Commodity Specification for Air, G-7 (Grade D or higher quality).

HPP-110, Inspection and Maintenance of Respiratory Equipment, Rev. 10, dated November 12, 1988, provides instructions for inspection and maintenance of routine use of respiratory protective equipmen The procedure requires the breathing air to be sampled every 92+/-23 days to ensure air quality of Grade D or bette The inspectors reviewed and discussed with cognizant licensee representatives methods for verifying Grade D quality for the site supplied-air syste Licenkee representatives stated that air to the system was provided by one of four compressors utilized at the site, quarterly samples were collected from six separate locations, and samples were processed by a vendor laborator The inspectors noted and discussed the following issues regarding the licensee's sampling and Grade D verification program for the supplied-air breathing syste Criteria specifying Grade D-air, sampling locations, and licensee actions to recertify and conduct followup actions regarding air samples not meeting the vendor established Grade D criteria were not specifie Additionally, the procedure did not require collection and verification of Grade D for air samples collected on a routine basis for each compressor potentially providing input to the supplied-air syste Licensee representatives stated that all sampling was conducted by a radiation control technician trained and qualified in the subject task and criteria for verification of GradeD quality for each air sample were detailed in the vendor contract specification Documentation supporting these licensee statements, including technician qualification review forms for the sampling task and vendor specifications for assuring Grade D air quality were provided to the inspectors for revie The January 1, 1989, through September 30, 1990 records for supplied-air system quarterly sampling and verification of Grade D quality were reviewe The reviewed records indicated that for each designated sample location the supplied-air system was sampled and verified on a quarterly basi From review of vendor results, applicable Plant Improvement Requests (PIRs),

and discussion with cognizant licensee representatives, the inspector noted that samples from supplied-air lines not meeting Grade D quality were removed from servic In addition, the inspectors noted that the vendor's Grade D quality specifications were upgraded to reduce the Carbon Monoxide (CO)

limit from 20 to 10 parts per million (ppm)

following the second quarter 1989, and thus met the most current CO limits specified in the compressed Gas Association, In Standard, ANSI/CGA G7.1-198 However, by the end of the onsite inspection licensee representatives were unable to provide documentation indicating that each of the compressor systems potentially supplying input to the supplied-air system were sampled and Grade D air verified on a routine basis. The inspector informed licensee representatives that pending their proposed review of operational records, this issue regarding the adequacy of their sampling to meet Grade D air criteria for all compressor systems would be considered an unresolved item (URI)* (50-261/90-25-02).

One URI pending the licensee's evalution to determine verification of Grade D quality air for all supplied-air breathing system compressors was identifie.

Internal Exposure (83750)

10 CFR 20.103(a)(1) states that no licensee shall possess, use, or transfer licensed material in such a manner as to permit any individual in a restricted area to inhale a quantity of radioactive material in any period of one calendar quarter greater than the quantity which would result from inhalation for 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> per week for 13 weeks at uniform concentrations of radioactive material in air specified in 10 CFR Part 20 Appendix B, Table 1, Column CFR 20.103(a)(3) requires for purposes of determining compliance with the requirements of this section, the licensee shall use measurements of radioactivity in the body, measurements of radioactivity excreted from the body, or any combination of such measurements as may be necessary for the timely detection and assessment of individual intakes of radioactivity by exposed individual TS 6.1. requires procedures for personnel radiation protection to be prepared consistent with the requirements of 10 CFR Part 20 and to be approved, maintained and adhered to for all operations involving personnel radiation exposur *An unresolved item is an item about which more information is required to ascertain whether it is an acceptable item, a deviation, or a violatio Internal Exposure Evaluation Procedures Licensee's procedures to implement 10 CFR Part 20.103 requirements were reviewed and discussed with cognizant licensee representative Dosimetry Procedure (DP)-018, Personnel Whole Body Counting, Rev.' 8, dated June 20, 1989, details guidance for conducting quality control checks and maintenance for the current licensee's body burden analysis syste Additionally the, procedure describes required frequency and guidance for conducting body burden analyses. Annual whole body counts are required for personnel issued thermoluminescent dosimetry.. Special analysis are required for special conditions including facial contamination exceeding 1,000 disintegrations per minute (dpm)

and suspect internal contamination exceeding 40 maximum permissible airborne concentration-hours (MPCa-hr).

DP-011, Updating Whole Body Counts, Re, dated July 7, 1988, and DP-020, Assessment of Internal Dose, Rev. 2, dated October 15, 1988, provide guidance for updating records and calculating internal doses/MPCa-hrs based on in vivo and in vitro monitoring result The inspectors verified that the licensee utilized acceptable methods, Internal Council of Radiation Protection II (ICRP II)

methodology, for conducting internal exposure evaluation MPCa-hrs are calculated when the maximum permissible organ burden (MPOB), equals or exceeds two percen MPCa-hr evaluation results derived from calulations involving internally deposited radioruclides take precendence over MPCa-hrs based on air samplin HPP-105, Grab Air Sampling and Control of MPC-hours, Re,

dated September 22, 1989, establishes methods for collecting airborne radioactivity grab samples and for documenting the MPCa fraction collected for purposes of respiratory protectio The procedure requires that everytime respiratory protective equipment is utilized an air sample is collected and also that exposures to airborne materials exceeding 40 MPCa-hrs are investigate The inspectors noted that for the selected review conducted, licensee guidance met 10 CFR 20 requirement No violations or deviations were identifie b. Program Implementation Licensee implementation of annual and special whole body analyses and air sampling during the current outage was reviewe The inspectors reviewed and verified completion of the annual whole body analyses for selected RC supervisory and managerial personne In addition, the inspectors reviewed selected September 1, through November 6, 1990, contamination event shift logbooks and verified that for all facial contamination events, whole body count analyses were conducted in accordance with procedural guidanc In addition, the inspectors verified whole body analysis quality control checks were conducted at specified frequencie Licensee records of air sampling results used to evaluate the hazard associated with reactor head removal and S/G activities during September 1990 and November 1990, respectively, were reviewe The inspectors discussed and reviewed the minimum detectable activity (MDA)

based on a sample time of approximately 5 minutes with a flow rate of 2 cubic feet per minute which was noted for several sample analyse Cognizant licensee representatives calculated a

MDA of 6.13 E-11 microcuries per cubic centimeter (mCi/cc) which was less than the MPCa of 3.OE-9 uCi/cc for gross beta/gamma emitters listed in 10 CFR Part 20, Appendix B, Table 1, Column 1. The inspectors noted that for the tasks reviewed, the majority of air sampling results indicated that airborne gross beta/gamma concentrations were less than 25 percent of the MPC No violations or deviations were identifie c. Termination Whole Body Analysis Reports DP-018, Personnel Whole Body Counting, Re, dated June 20, 1990, requires the licensee to attempt to count all personnel upon terminatio If a terminated individual is not available (permanently exited the site), and every reasonable effort has been made to contact the individual, the procedure requires the immediate supervisor of the termihated individual to complete and place Attachment 11.5, Documentation of a Missing Whole Body Count, into the individual's exposure history file maintained by the onsite Dosimetry Departmen From review of selected. termination reports, the inspector noted numerous persons with no record of a termination whole body coun DP-001, Dosimetry Issuance, Re,

dated June 23, 1990, permits the licensee to waive the termination whole body count for individuals who never entered the RC For individuals who have entered the RCA, a

missed whole body count requires that Attachment 11.5 of DP-018 be put into the individual's dosimetry fil The licensee was able to verify that for the files reviewed, excluding one employee, none of the selected individuals had entered the RCA. The one employee previously entered the RCA on September 7, 1990, and terminated employment on September 19, 199 Further review of the issue indicated that the individual's supervisor did not complete Attachment 11.5 nor was any information placed in the individual's file clarifying reasons for the missed termination whole body coun The failure to follow procedures for documentation of a missed whole body count was identified as a violation of TS 6.11 (50-261/90-25-03).

The licensee initiated immediate corrective action by the appropriate supervisor, including completion of the Attachment 11.5 and subsequent placement into the terminated individual's dosimetry fil The inspector informed licensee representatives this NRC-identified violation was not being cited because criteria specified in Section V.A of the enforcement policy were me One NRC-identified NCV for failure to complete appropriate termination whole body analysis documentation was identifie.

External Exposure (83750)

10 CFR 20.101 requires that no licensee possess, use, or transfer licensed material in such a manner as to cause any individual in a restricted area to receive in any period of one calendar quarter a total occupational dose in excess of 1.25 rems to the whole body, head and trunk, activity blood forming organs, lens of the eyes, or gonads; 18.75 rems to the hands, forearms, feet and ankles; and 7.5 rems to the skin of the whole bod During the onsite audit, the licensee's program for whole body and extremity monitoring was reviewe a. Extremity Monitoring DP-001, Dosimetry Issuance, Rev. 21, dated June 23, 1990, details the instructions for monitoring external radiation exposure including the criteria for issuing multiple and whole body and extremity thermoluminescent dosimetry (TLD)

badge During discussion of implementation of the monitoring procedure for high dose rate outage tasks, cognizant licensee representatives stated that all extremity monitoring was conducted utilizing wrist-mounted rather than finger-mounted TLD badge The licensee provided a previous study, Routine Hand Doses versus Monitoring Regulations, dated 1980, which indicated that monitored extremity (hand)

doses were less than regulatory limits requiring use of monitoring device In addition, a licensee report, Multibading/Extremity Monitoring Analysis -

1988 Refueling Outage, dated August 30, 1989, was reviewed which provided supplemental information indicating that for most high dose rate tasks at the facility, extremity monitoring was not required based on the multibadging procedural requirement The inspectors noted that the initial 1980 study of extremity monitoring requirements was conducted for routine activities and did not focus on high dose rate task Furthermore, only wrist badges were used during the 1988 study without determining the ratio of wrist-mounted to finger-mounted TLD results and then calculating the maximum dose rate to the tips of the finger The January 1, through September 30, 1990 quarterly extremity exposure results for individuals, as measured using wrist-mounted TLDs, were reviewe The maximum quarterly extremity dose reported was 1,944 millirem (mrem).

The inspectors informed licensee representatives that ratios exceeding a factor of two for finger-to wrist-mounted TLD extremity results for selected tasks at several power reactor facilities have been reporte The inspectors noted that there were no studies of placement of extremity monitoring for site specific tasks involving handling of high dose rate materials, to confirm the accuracy of the licensee's extremity monitoring progra Licensee representatives stated that they would conduct a study of

extremity dosimetry placement for high dose rate tasks. The inspector informed licensee representatives that NRC review of licensee results regarding this issue would be tracked as an Inspector Followup Item (IFI) (50-261/90-25-04).

No violations or deviations were identifie Form NRC-4 10 CFR 20.102(b) requires, under certain circumstances, the licensee to obtain a certificate on Form NRC-4, signed by the individual showing each period of time after.the individual attained the age of 18 in which an occupational dose to radiation was received. This signed and completed form shall be obtained before permitting the individual in a restricted area to receive an occupational radiation dose in excess of the standards specified in 10 CFR 20.101(a).

The inspectors reviewed selected individual's records on the licensee's RIMS for the existance of the individual's Form NRC-Records of workers signed on RWP's associated with potentially high dose jobs were reviewed. The inspectors rioted a Form NRC-4 on file for all selected individual No violations or deviations were identifie. Surveys, Monitoring, and Control of Radioactive Material and Contamination (83750) High Radiation Area Control TS 6.13.1 details radiological controls required in lieu of the control device or alarm signal required by 10 CFR 20.203(c) for high radiation areas where radiation exceeds-100 and 1,000 millirem per hour (mr/hr).

During tours of the Auxiliary and Containment Buildings conducted from November 5 through 9, 1990, the inspectors verified that control of activities conducted in high radiation areas was conducted in accordance with the applicable TS requirement No violations or deviations were identifie Labeling and Posting 10 CFR 20.203(e) requires each area in which licensed material is used or stored and which contains any radioactive material in an amount exceeding ten (10)

times the quantity of such material specified in Appendix C of this part to be posted with a sign or signs bearing the radiation caution symbol and the words: "Caution, Radioactive Material (s)."

10 CFR 20.203(f) requires each container of licensed material to bear a durable, clearly visible label identifying the radioactive contents and providing sufficient information to permit individuals handling or using the containers, or working in the vicinity thereof, to take precautions to avoid or minimize exposure HPP-007, Handling and Storage of Contaminated and Radioactive Materials, Rev. 5, dated May 2, 1989, requires that the handling and storage of contaminated/radioactive material be conducted in accordance with regulations of 10 CFR Part 2 During tours of the licensee's, RCA, the inspectors reviewed labeling used to denote radioactive material hazards on selected barrels, storage bins and containers utilized to store contaminated equipment or to place radioactive waste awaiting shipment to an offsite vendor facility for compactio On November 7, 1990, the inspectors noted more than 10 storage boxes located in the RCA with the radioactive material information required by 10 CFR 20.203(f) written on adhesive tape affixed beneath, and not on the radioactive material labe In addition, for three storage boxes/bins the radiological information and dates differed between label/tape affixed to separate sides of the containe Licensee representatives stated that the discrepancies regarding required information noted between different sides of a box occurred, most likely, as the result of adjacent containers obscuring or preventing the RCT from noting and removing the old label information. In addition, the licensee stated that the habit of writing the required radioactive material label information on a separate. piece of adhesive tape resulted from numerous survey updates required during the filling of containers with radioactive waste. However, subsequent to discussions with the inspectors and review of the regulations, cognizant licensee representatives agreed that the appropriate information should be placed on the designated radioactive material label and subsequently instructed the RC technicians to eliminate use of the adhesive tape for labeling purpose The inspectors informed licensee individuals that the failure to label containers properly was a violation of 10 CFR 20.203(f) requirements (50-261/90-25-05). Prior to the end of the onsite inspection, licensee representatives removed improper radioactive labels as necessary, resurveyed the containers, and relabeled all containers appropriatel The inspectors verified the corrective actions and informed licensee representatives that this NRC-identified violation was not being cited because criteria specified in Section V.A of the enforcement policy were me One NRC-identified NCV for failure to label containers in accordance with 10 CFR 20.203(f) requirements was identifie Surveys 10 CFR 20.201(b) requires each licensee to make or cause to be made such surveys as may be necessary for the licensee to comply with the regulations in 10 CFR Part 20 and are reasonable under the

circumstances to evaluate the extent of radiation hazards that may be presen During tours of selected facility areas, the inspectors verified that personnel survey equipment in use was calibrated in accordance with the applicable procedure Confirmatory radiation and/or contamination surveys also were conducted to verify posted Auxiliary Building room radiation hazards and to determine compliance with contamination level limits for release of items from contaminated RCA area Verification radiation/

contamination surveys conducted November 6-7, 1990, for the Auxiliary Building Northside Drumming and Number 1 Auxiliary Sump rooms indicated that posted radiation surveys and controls were adequate to evaluate the extent of the radiation hazards present. In addition, supplemental contamination surveys of compressed gas bottles previously released from a contaminated area within the Auxiliary Building verified contamination levels were less than 1,000 disintegrations per minute per 100 square centimeters (dpm/100 cm2).

No violations or deviations were identifie d. Termination Reports 10 CFR 20.408(b) and 20.409(b) require that the licensee make a report to the Commission, arid notify the individual involved, of the radiation exposure of each individual who has terminated employment. The report is to be furnished within 30 days after the individual's exposure was determined by the licensee or 90 days after the date of termination of employment or work assignment, whichever is earlie DP-009, Termination/Deactivation of Employees, Re,

dated January 31, 1990, defines the licensee's procedure to assure complete and accurate reporting of exposures of employees as required by 10 CFR Parts 19 and 2 The dosimetry group was responsible for the tracking of monthly terminations and "normally after 10 days of the termination date" sending exposure results and other termination information to the licensee's Harris Energy and Environmental Center (HE&EC)

for termination processin The HE&EC issues termination reports to employees with the radiation exposure received while at Robinson. The inspector noted timely readings of TLDs by the onsite dosimetry group following an employee's termination, forwarding of termination information to the HE&EC normally within 10 days, and the timely issuance of letters with an exposure report to the terminated individuals by the HE&E Personnel Contamination Events The inspectors reviewed records of personnel contaminations for 1990 and the RF13 outage. As of October 31, 1990, the licensee experienced 122 personnel contamination events (PCEs)

which was within the

cumulative goal to date of 148 PCEs. The PCE goal for 1990 was 300. The licensee experienced only 93 PCEs in 198 The lower number was attributable to fewer outage days and less entries into the RC No violations or deviations were identifie.

Program for Maintaining Exposures As Low As Reasonably Achievable (ALARA)

(83750)

10 CFR 20.1c states that persons engaged in activities under licenses issued by the NRC should make every reasonable effort to maintain radiation exposures ALARA. The recommended elements of an ALARA program are contained in Regulatory Guide 8.8, Information Relevant to Ensuring that Occupational Radiation Exposure at Nuclear Power Stations will be ALARA, and Regulatory Guide 8.10, Operating Philosophy for Maintaining Occupational Radiation Exposures ALAR Regulatory Guides 8.8 and 8.10 provide information relevant to attaining goals and objectives for planning and operating light water reactors and provide general philosophy acceptable to the NRC as a necessary basis for a program of maintaining occupational exposures ALAR CFR 20.1(c) states that persons engaged in activities under licenses issued by the NRC should make every reasonable effort to maintain radiation exposures ALAR a. Organization The inspectors reviewed the licensee's organizational structure for ALARA responsibilities, including the delineation of authority and responsibilit During normal operations, the licensee's ALARA staff consists of two ALARA Specialists and an ALARA Technician (rotating position). During the outage, the ALARA staff was supplemented with a Corporate senior ALARA specialist and a contract ALARA technician. The ALARA staff reported to the E&RC Manager. The ALARA Committee consisted of representatives from the following departments: plant management, instrumentation and control, mechanical maintenance, E&RC, operations, technical support, modifications projects, and QA/Q In addition, representatives from planning and scheduling, design engineering, and training were also members. The ALARA Committee Chairman was the ALARA Specialist. Monthly Committee member attendance for 1990 was generally good, however Modification Projects showed the poorest attendance record in that the member or alternate missed four out of eleven meeting The responsibilities of the ALARA Committee were described in AP-034, ALARA Committee Activities and Responsibilities, Revision 0, June 29, 198 Some of the accomplishments of the ALARA Committee during the last 12 months included the following:

(1) use of long-life light bulbs in the plant to minimize entries for light replacement; (2) use of submicron absolute filters after the letdown demineralizers to aid in reducing source term; (3) scheduling a surrogate video tour

of the entire plant; and (4) development of a new ALARA incentive program to promote quality ALARA suggestion The. inspectors also noted that professional development training was provided to the ALARA Specialist by attending REM Seminars and the Region II ALARA supervisor's meeting in 199 ALARA Reviews The inspectors reviewed selected work tasks to verify that pre-job ALARA reviews were conducte Since RF13 outage was ongoing at the time of this inspection, post-job reviews were not availabl The inspectors determined that for the selected jobs reviewed, pre-job reviews adequately addressed the work to be performed and incorporated lessons learned from past post-job review Pre-job ALARA review criteria were specified in Plant Program Procedure PLP-016, Radiation Work Permit Program, Revision 9, September 28, 198 All jobs with projected collective doses greater than one person-rem received a pre-job ALARA review. All nonroutine tasks with a projected collective dose greater than 25 person-rem were subjected to review by the ALARA Committee. ALARA Specialists reviewed daily access control reports and ALARA summary review reports as necessary to perform ALARA reviews of on-going work activitie Field observations from RCTs and radiation workers also were considere The following pre-job review packages were examined: (1) -RWP 90-0788:

inspect and repair S/G tube plugs; (2) RWP 90-0659: install, transport, and remove eddy current testing equipment; and (3) RWP 90-0633: Reactor head removal (ALARA Committee review included).

Based upon data provided by the licensee, over 99 percent of the accumulated collective dose for RF13 as of November 7, 1990, had received a pre-job ALARA revie An analogous pre-job review percentage was observed for RF1 ALARA Goals, Objectives, and Results The inspectors discussed with licensee representatives the total annual collective dose against their goals and the industry average The 1990 collective dose goal was 450 person-re As of November 7, 1990, the actual collective dose was 242 person-rem. Approximately 65 percent of the scheduled outage work had been completed. The licensee was well below its projected accumulated station collective dose of approximately 400 person-re The licensee's three year average collective dose (1987-1989)

was 426 person-re The high three year average was partially due to the resistance temperature detector (RTD) bypass removal job performed in 1988 (103 person-rem).

No violations or deviations were identifie.

Facility Tours (83750)

10 CFR 19.11(a) and (b) require, in part, that the licensee post current copies of Part 19, Part 20, the license, license conditions, documents incorporated into the license, license amendments and operating procedures, or that a licensee post a notice describing these documents and where they may be examine CFR 19.11(d)

requires that a licensee post Form NRC-3, Notice to Employee Sufficient copies of the required forms are to be posted to permit licensee workers to observe them on the way to or from licensed activity location During the onsite audit, the inspectors verified that NRC Form 3 and notices referencing the appropriate 10 CFR Part 19 and Part 20 and licensee documents were posted in accordance with the applicable regulatio Forms were posted at the West PAP entrance to the controlled are No visible forms were posted at the East PAP but following discussions with the licensee and tours of the facility the inspector verified that such forms were posted at the entrance to the RCA where all employees must pass to claim their dosimetr No violations or deviations were identifie.

Followup Items (92701, 92702) Previous Violations (Closed) 50-261/89-22-01:

Failure to perform adequate release surveys of tools and equipment leaving the plant site as required by 10 CFR 20.201(b).

The inspectors reviewed the licensee's response to the Notice of Violation in a letter dated November 15, 1989, and ascertained that the response and stated corrective actions were timely, appropriate and implemente The licensee established a special task force comprised of Radiation Control and Regulatory Compliance personnel to determine the root cause of the violation. The generic implications were addressed and the licensee's QA program practices and procedures were strengthened to prevent recurrenc Licensee management had expanded the Monthly Performance Monitoring program to three years to assess trends for similar event This item is considered close Information Notices Information Notices (INs)

are first reviewed at the licensee's Corporate Office in Raleigh for applicability and then are sent to each facility.. Subsequently, each IN is reviewed by the Robinson Onsite Nuclear Safety (ONS)

Uni If the ONS Unit is satisfied with the corporate assessment, the IN is incorporated onsite as assesse If additional comments are made by the ONS Unit regarding the assessment, the Notice is reviewed for applicability and then returned to the

corporate offic This review process continues until all parties concur with the IN assessmen Once the final assessment has been made, the ONS Unit is responsible for assuring,that any operating information, per each IN, pertinent to plant nuclear safety is supplied to the operating and training organization The inspectors determined that the following INs were still in the review process at the corporate office in Raleigh:

o IN 90-31:

Update on Waste Form and High Integrity Container Topical Report Review Status, Identification of Problems With Cement Solidification, and Reporting of Waste Mishaps o

IN 90-33:

Sources of Unexpected Occupational Radiation Exposures at Spent Fuel Storage Pools o

IN 90-35:

Transportation of Type A Quantities of Non-Fissile Radioactive Materials

IN 90-47:

Unplanned Radiation Exposures to Personnel Extremities Due to Improper Handling of Potentially Highly Radioactive Sources o

IN 90-48:

Enforcement Policy for Hot Particle Exposures The inspectors determined that the following INs had been received by the licensee, reviewed for applicability, distributed to appropriate personnel, and that action, as appropriate was taken or scheduled:

o IN 88-79:

Misuse of Flashing Lights For High Radiation Area Controls o

IN 89-13:

Alternative Waste Management Procedures In Case of Denial of Access to Low-Level Waste Disposal Sites o

IN 89-27:

Limitations On The Use of Waste Forms and High Integrity Containers for the Disposal of Low-Level Radioactive Waste o

IN 89-47:

Potential Problems with Worn or Distorted Hose Clamps on Self-Contained Breathing Apparatus o

IN 90-08:

Kr-85 Hazards from Decayed Fuel o

IN 90-44:

Dose-Rate Instruments Underresponding to the True Radiation Fields 1 Exit Meeting The inspectors met with licensee representatives (denoted in Paragraph 1) at the conclusion of the inspection on November 8, 199 The inspectors summarized the scope and findings of the inspection, including the URI,

NCVs, and the IF The inspectors also discussed the likely informational content of the inspection report with regard to documents or processes reviewed by the inspector during the inspectio The licensee did not identify any such documents or processes as proprietar Dissenting comments were,not received from the license Item Number Description and Reference 50-261/90-25-01 NCV: Failure to barricade a high radiation area in accordance with TS 6.1 (Paragraph 3).

50-261/90-25-02 URI:

Potential failure to verify Grade D quality air for all supplied-air breathing system compressors (Paragraph 6.b).

50-261/90-25-03 NCV:

Failure to complete appropriate termination documentation in accordance with DP-018, Personnel Whole Body Counting (Paragraph 7.c).

50-261/90-25-04 IFI:

Evaluate the effectiveness of using ring TLDs versus wrist TLDs (Paragraph 8.a).

50-261/90-25-05 NCV:

Failure to label properly containers of licensed material in accordance with 10 CFR 20.203(f)(Paragraph 9.b).

Licensee management was informed that the violation discussed in Paragraph 12 was considered closed.