05000254/LER-1979-001, Forwards LER 79-001/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 79-001/03L-0
ML19261B196
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 01/19/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19261B197 List:
References
NJK-79-29, NUDOCS 7902140155
Download: ML19261B196 (1)


LER-1979-001, Forwards LER 79-001/03L-0
Event date:
Report date:
2541979001R00 - NRC Website

text

0 00_.

@ Commonwealth Edison Quad Cities Nuclear Power Station 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-79-29 January 19, 1979 J. Keppler, Regional Director Of fice of Inspection and Enforcement Reg!on 111 U.S. Nuc. lear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 Re fe rence:

Quad-Cities Nuclear Power Station Docket No. 50-254, DPR-29, Unit 1 Appendix A, Sections 3.5.E.1 and 6.6.B.2.b.

Enciosed please find Reportable Occurrence Report No. R0 79-01/03L for Quad-Ci t ies Nuclear Power Station.

This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B.2.b, as a condition leading to operation in a degraded mode permitted by a limiting condition for operation.

Very truly yours, COMMONWEALTH EDIS0N COMPANY QUAD-CITIES NUCLEAR POWER STATION

/

/df/

s N.J. Ka l i ianakis Station Superintendent i s N J K/J CV,'cb cc:

R.F. Janecek

~ 379 7 9 0 214 0 IST 8'Vg 5