Forwards Safety Evaluation Supporting Proposed Redesign of Steam Generator Upper Support of Reactor Coolant Loop Sys for Unit 2 & Revised FSAR Pages.Revised Steam Generator Upper Support Design Would Reduce Number of Snubbers to Two
ML20235S797
Person / Time
Site: Vogtle Southern Nuclear icon.png
Issue date: 10/07/1987
From: Mark Miller
Office of Nuclear Reactor Regulation
To: James O'Reilly
GEORGIA POWER CO.
Shared Package
ML20235S801 List:
References
TAC-65082, NUDOCS 8710090142
Download: ML20235S797 (1)


Text

'

Docket No.: 50-425 Mr. James P. O'Reilly Senior Vice President - Nuclear Operations Georgia Power Company 00T 0 71987 P.O. Box 4545 Atlanta, Georgia 30302

Dear Mr. O'Reilly:

Subject:

Staff Acceptance of Vogtle Unit 2 Steam Generator Snubber Reduction (TAC 65082)

By letters dated July 1, and August 6, 1987, Georgia Power Company (GPC) i proposed a redesign of the steam generator upper support of the reactor coolant loop system for Vogtle Unit 2 by submitting a technical evaluation i and the proposed revised FSAR pages. The revised steam generator upper support design would reduce the number of snubbers per steam generator from five to two.

The staff has reviewed GPC's submittals and concludes that the proposed  !

steam generator redesign is acceptable. The staff's evaluation is enclosed. i l

Sincerely,

%\ l Melanie A. Miller, Project Manager Project Directorate 11-3 Division of Reactor Projects I/II

Enclosure:

As stated cc :- See next page l DISTRIBUTION:

Docket File TSullivan NRC PDR PDll-3 Reading H. Shaw Local PDR MDuncan K. Wichman OGC-Bethesda SVarga/Glainas S. Lee JPartlow EJordan ACRS(10) MMiller lyt b F}Qfly$7hPI/II .M -h PI/II PDJ MD,6n@' ta'n k/DNRR/EM PI/II MMfTler/ rad TSullivan Ab g PD 10/6/87 10/ /87 10/(,/87 10 /87 8710090142 871007T PDR ADOCK 05000425 A PDR

_______j