Informs That Licensee Vessel Data Is Different than NRC Database Based on Listed Info,Per 990722 Request to Review Rvid
ML20211J738
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 08/27/1999
From: Beasley J
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LCV-1372, TAC-MA0581, TAC-MA0582, NUDOCS 9909070004
Download: ML20211J738 (2)


Text

..........

.(

- J. Bernie Beastry. Jr., P.E. ~ Southern Nuciasr

' Vice President Opsrating Company, Inc.

Vogtie Project

' 40 Inumess Center Parkway l,-

. P0 Box 1235 --

8 rmingham, Alabama 35201 Tel 205 992.7110 fax 2059970403 SOUTHERN COMPANY Er:ergy to Serve Your %rld" August 27,1999 LCV-1372 Docket Nos.: 50-424 50-425-Tac Nos.:

MA0581 MA0582 U. S. Nuclear Regulatory Commission Attn: Document Control Desk.

Washington, DC 20555 Ladies and Gentlemen:

VOGTLE ELECTRIC GENERATING PLANT REVIEW OF REACTOR VESSEL INTEGRITY DATABASE As requested in your letter ofJuly 22,1999, the Reactor Vessel Integrity Database (RVID) has been reviewed. Our vessel data is different than the NRC database based on the following:

The RVID2 database is out-of-date. Only two surveillance capsules (U and Y) are

' included in the RVID2 database for Vogtle Unit 1. Capsule V has been pulled, and

the results of the analysis were forwarded by the Southern Nuclear letter dated October 2,1998. Only two surveillance capsules (U and Y) are included in the RVID2 database for Vogtle Unit 2, Capsule X has been pulled, and the results of the analysis were forwarded by the Southern Nuclear letter dated March 17,1999.

l 0 The percent drop in upper shelf energy (USE) at end-of-life (EOL) at % T for the e

Vogtle plates that are not included in the surveillance capsule program should use copper values for both Vogtle reactor vessels that are less than the 0.10% value included in Figure 2 of Regulatory Guide 1.99, Revision 2. It appears that the NRC i

0g.

Staff conservatively used the curve for 0.10% copper that results in a conservative 0

evaluation for both the Vogtle reactor vessels.

E

\\

99o9070004 990827 PDR ADOCK 0 4y4 P

.=.

U. S. Nuclear Regulatory Commission j

1 LCK-1372 Page 2 -

.The RVID2 values for RT ns t EOL for Vogtle Unit 2 lower shell plate B8628-1 and a

e

- for the circumferential and axial welds calculated by the NRC are not as conservative as those calculated by Southern Nuclear.

Please contact this office if you have any questions.

Sincerely, _

)

. B. Be s e r.

JBB/pah cc:

& thern Nuclear Operatine Company

f. T. Gasser h.

M. Sheibani SNC Document Management U. S. Nuclear Regulatory Commission Mr. L. A. Reyes, Regional Administrator Mr. Ramin R. Assa, Vogtle Project Manager, NRR Mr. J. Zeiler, Senior Resident inspector, Vogtle l