ML21215A009

From kanterella
Jump to navigation Jump to search
Review Status Report 8-2-2021
ML21215A009
Person / Time
Site: Vogtle 
Issue date: 08/03/2021
From:
NRC/NRR/VPOB
To:
Gaslevic J
References
Download: ML21215A009 (80)


Text

Key for Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Status Report The following describes each column in the report:

ITAAC Index No.: A sequential number assigned to each ITAAC in Appendix C of the combined license (COL) at issuance. Because ITAAC may be added, deleted, or consolidated through license amendments, the highest ITAAC index number may not equal the total number of ITAAC. An ITAAC index number may also be out of numerical sequence from the current COL due to ITAAC amendments after initial COL issuance.

ITAAC No.: A number assigned to an ITAAC based on the Section of Appendix C of the COL in which the ITAAC appears.

ITAAC Notification Type (ICN, IPCN, UIN): The three types of licensee ITAAC notifications listed in this report:

- ICN: ITAAC closure notifications (ICNs) submitted pursuant to 10 CFR 52.99(c)(1),

- IPCN: ITAAC post-closure notifications (IPCNs) submitted pursuant to 10 CFR 52.99(c)(2), and

- UIN: uncompleted ITAAC notifications (UINs) submitted pursuant to 10 CFR 52.99(c)(3).

ITAAC Notification: The Agencywide Documents Access and Management System (ADAMS) accession numbers for the licensees ITAAC notifications.

NRC Checklist (VEF or UINC): The Agencywide Documents Access and Management System (ADAMS) accession numbers for the NRC staffs verification and evaluation forms (VEFs) and Uncompleted ITAAC Notification Checklists (UINCs). A VEF documents the NRCs review of ICNs and IPCNs. A UINC documents the NRCs review of UINs.

ITAAC Notification Review Status: The status of the NRCs review of the ITAAC notification.

- Unconditionally Verified as Completed or Federal Register Notice Published denote when the NRC has found an ICN or IPCN is acceptable. The licensee has successfully completed the closure of these ITAAC.

- Sufficient Information denotes when the UIN sufficiently describes the proposed methodology for closing the ITAAC. UIN reviews are not based on actual performance of the ITAAC, the acceptance criteria results, the completion of NRC inspections, or the resolution of NRC inspection findings. The NRC considers these matters during corresponding ICN review.

Federal Register No. or NRC Letter: The Federal Register No. is the citation for periodically-issued Federal Register notices of NRC determinations that ITAAC have been successfully completed. An NRC letter explains to the licensee why the NRC has determined that an ITAAC notification is not acceptable.

NRC Construction Inspection Report(s): ADAMS Accession No. for reports documenting ITAAC-related construction inspections.

NRC Vendor Inspection Report(s): ADAMS Accession No. for reports documenting ITAAC-related vendor inspections.

Report Print Date: 8/2/2021 7:14:10 AM Page 1 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 1 2.1.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 2 2.1.01.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 3 2.1.01.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 4 2.1.01.04 UIN ML18205A453 ML18262A388 Sufficient Information 2.1.01.04 ICN Not Received 5 2.1.01.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 6 2.1.01.06.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 7 2.1.01.06.ii ICN ML16214A248 ML17103A214 Federal Register Notice Published 82 FR 34992 ML17044A539 8 2.1.01.07.i ICN ML17103A053 ML17109A171 Federal Register Notice Published 83 FR 6217 9 2.1.01.07.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 10 2.1.01.07.iii ICN ML16182A348 ML16193A381 Federal Register Notice Published 82 FR 19758 11 2.1.01.07.iv ICN ML16182A355 ML17300B212 Federal Register Notice Published 83 FR 6217 ML17044A539 ML17317A527 Report Print Date: 8/2/2021 7:14:10 AM Page 2 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 12 2.1.02.01 UIN ML17214A765 ML18107A192 Sufficient Information 2.1.02.01 ICN Not Received 13 2.1.02.02a UIN ML18032A511 ML18100A784 Sufficient Information ML17226A034 ML17317A527 ML18045A476 ML18134A348 ML18226A348 ML18317A395 ML19045A614 ML19135A691 ML19220B678 ML19309D596 ML20042E292 ML20128J831 ML20315A455 ML14073A652 2.1.02.02a ICN Not Received 14 2.1.02.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 15 2.1.02.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 16 2.1.02.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 17 2.1.02.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 18 2.1.02.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 3 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 19 2.1.02.05a.i UIN ML18106A741 ML18116A141 Sufficient Information ML17317A527 ML18045A476 ML18226A348 ML19220B678 ML20315A455 ML12128A072 ML12128A072 ML14231B268 ML15078A379 ML17311A26 ML14073A652 ML12313A461 ML16307A159 ML20128J831 ML18102B171 ML20216A590 2.1.02.05a.i ICN Not Received 20 2.1.02.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 21 2.1.02.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 22 2.1.02.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 23 2.1.02.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 24 2.1.02.07a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 25 2.1.02.07a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 26 2.1.02.07b UIN ML19225C361 ML19232A481 Sufficient Information 2.1.02.07b ICN Not Received 27 2.1.02.07c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 28 2.1.02.08a.i ICN ML16090A237 ML17276B855 Federal Register Notice Published 82FR55658 ML16032A554 ML17226A034 29 2.1.02.08a.ii ICN ML16090A219 ML16137A159 Federal Register Notice Published 81FR69553 ML16032A554 Report Print Date: 8/2/2021 7:14:10 AM Page 4 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 30 2.1.02.08b UIN ML19030B400 ML19036A802 Sufficient Information 2.1.02.08b ICN Not Received 31 2.1.02.08c ICN ML18087A016 ML18107A806 Federal Register Notice Published 83FR34890 32 2.1.02.08d.i UIN ML19050A368 ML19063A968 Sufficient Information 2.1.02.08d.i ICN Not Received 33 2.1.02.08d.ii UIN ML18205A423 ML18233A284 Sufficient Information 2.1.02.08d.ii ICN Not Received 34 2.1.02.08d.iii ICN ML17016A014 ML17270A103 Federal Register Notice Published 82 FR 55658 ML17132A345 ML17226A034 35 2.1.02.08d.iv ICN ML20090C009 ML20094G718 Federal Register Notice Published 85FR29755 ML17132A345 36 2.1.02.08d.v UIN ML20297A370 ML20302A091 Sufficient Information ML20128J831 2.1.02.08d.v ICN Not Received 37 2.1.02.08d.vi ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 38 2.1.02.08d.vii ICN ML16271A140 ML18051A574 Federal Register Notice Published 83FR6217 ML17044A539 ML17317A527 39 2.1.02.08d.viii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 40 2.1.02.08e UIN ML18211A636 ML18262A397 Sufficient Information 2.1.02.08e ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 5 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 41 2.1.02.09a UIN ML19336D350 ML19339E775 Sufficient Information 2.1.02.09a ICN Not Received 42 2.1.02.09b.i ICN ML16357A082 ML16363A413 Federal Register Notice Published 83FR34890 43 2.1.02.09b.ii UIN ML18107A114 ML18135A170 Sufficient Information 2.1.02.09b.ii ICN Not Received 44 2.1.02.09c UIN ML19163A187 ML19178A364 Sufficient Information 2.1.02.09c ICN Not Received 45 2.1.02.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 46 2.1.02.11a.i UIN ML19031B848 ML19036A966 Sufficient Information 2.1.02.11a.i ICN Not Received 47 2.1.02.11a.ii UIN ML19354A050 ML20013D812 Sufficient Information 2.1.02.11a.ii ICN Not Received 48 2.1.02.11b.i UIN ML19024A334 ML19031C935 Sufficient Information 2.1.02.11b.i ICN Not Received 49 2.1.02.11b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 50 2.1.02.11b.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 6 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 51 2.1.02.11c.i UIN ML18355A673 ML19010A185 Sufficient Information 2.1.02.11c.i ICN Not Received 52 2.1.02.11c.ii UIN ML17186A065 ML17215A903 Sufficient Information Cover Letter says ITAAC 2.2.02.11c.ii instead of 2.1.02.11c.ii.

2.1.02.11c.ii ICN Not Received 53 2.1.02.12a.i UIN ML18235A364 ML18241A128 Sufficient Information ML14016A447 ML14016A447 2.1.02.12a.i ICN Not Received 54 2.1.02.12a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 55 2.1.02.12a.iii UIN ML19221B697 ML19231A118 Sufficient Information 2.1.02.12a.iii ICN Not Received 56 2.1.02.12a.iv UIN ML18065A056 ML18079A868 Sufficient Information ML17226A034 ML12158A154 ML13302B397 ML15210A806 ML16027A153 2.1.02.12a.iv ICN Not Received 57 2.1.02.12a.v ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 58 2.1.02.12a.vi ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 59 2.1.02.12a.vii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 60 2.1.02.12a.viii ICN ML17016A013 ML17264A368 Federal Register Notice Published 83FR34890 61 2.1.02.12a.ix ICN ML20090C266 ML20094G813 Federal Register Notice Published 85FR29755 Report Print Date: 8/2/2021 7:14:10 AM Page 7 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 62 2.1.02.12b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 63 2.1.02.13a UIN ML18117A269 ML18122A295 Sufficient Information 2.1.02.13a ICN Not Received 64 2.1.02.13b UIN ML19163A117 ML19179A084 Sufficient Information 2.1.02.13b ICN Not Received 65 2.1.02.13c UIN ML17186A049 ML17283A242 Sufficient Information 2.1.02.13c ICN Not Received 66 2.1.02.14 UIN ML17186A119 ML18107A194 Sufficient Information 2.1.02.14 ICN Not Received 67 2.1.02.15 UIN ML18142A318 ML18152A853 Sufficient Information 2.1.02.15 ICN Not Received 68 2.1.03.01 UIN ML18045A380 ML18107A209 Sufficient Information 2.1.03.01 ICN Not Received 69 2.1.03.02a ICN ML20128J848 ML20129J966 Federal Register Notice Published 85FR29755 70 2.1.03.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 71 2.1.03.02c ICN ML17004A204 ML18102A901 Federal Register Notice Published 83FR34890 ML16210A448 ML18226A348 Report Print Date: 8/2/2021 7:14:10 AM Page 8 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 72 2.1.03.03 UIN ML18057A812 ML18135A169 Sufficient Information ML16210A448 ML18134A348 ML18317A395 ML19135A691 ML19220B678 ML19309D596 2.1.03.03 ICN Not Received 73 2.1.03.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 74 2.1.03.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 75 2.1.03.06.i UIN ML19305A429 ML19310D788 Sufficient Information ML18226A348 ML20315A455 2.1.03.06.i ICN Not Received 76 2.1.03.06.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 77 2.1.03.06.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 78 2.1.03.07.i UIN ML21165A203 ML21167A212 Sufficient Information 2.1.03.07.i ICN Not Received 79 2.1.03.07.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 80 2.1.03.08 ICN ML14245A167 ML14282A794 Federal Register Notice Published 83FR34890 81 2.1.03.09a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 82 2.1.03.09a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 83 2.1.03.09b UIN ML19191A173 ML19198A137 Sufficient Information 2.1.03.09b ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 9 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 84 2.1.03.09c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 85 2.1.03.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 86 2.1.03.11 ICN ML14219A725 ML14268A455 Federal Register Notice Published 79 FR 616 ML14311A666 87 2.1.03.12 UIN ML18142A295 ML18152A854 Sufficient Information 2.1.03.12 ICN Not Received 88 2.1.03.13 UIN ML17341A658 ML18003B236 Sufficient Information 2.1.03.13 ICN Not Received 89 2.1.03.14 ICN ML17152A201 ML17249A536 Federal Register Notice Published 83FR34890 90 2.2.01.01 UIN ML18072A250 ML18079A864 Sufficient Information ML18317A395 2.2.01.01 ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 10 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 91 2.2.01.02a UIN ML18054A121 ML18100A786 Sufficient Information ML12046A144 ML12220A476 ML12319A458 ML13030A390 ML13127A392 ML13207A241 ML13312A316 ML14112A413 ML14311A666 ML15037A406 ML15124A857 ML16312A506 ML17044A539 ML17226A034 ML18045A476 ML18134A348 ML18317A395 ML19135A691 ML19220B678 ML19309D596 ML20042E292 ML20128J831 ML20225A025 2.2.01.02a ICN Not Received 92 2.2.01.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 93 2.2.01.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 94 2.2.01.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 95 2.2.01.04a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 11 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 96 2.2.01.04a.ii ICN ML18362A186 ML19022A251 Federal Register Notice Published 84FR14980 ML12046A144 ML12220A476 ML12319A458 ML13207A241 ML14112A413 ML15037A406 ML15124A857 ML16312A506 ML17044A539 ML17226A034 ML19135A691 97 2.2.01.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 98 2.2.01.05.i UIN ML19017A280 ML19030A937 Sufficient Information ML18045A476 ML18226A348 ML19220B678 ML20315A455 ML12108A097 ML12179A413 ML16357A725 ML15148A419 2.2.01.05.i ICN Not Received 99 2.2.01.05.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 100 2.2.01.05.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 101 2.2.01.06a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 102 2.2.01.06a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 103 2.2.01.06b UIN ML19224B575 ML19232A087 Sufficient Information 2.2.01.06b ICN Not Received 104 2.2.01.06c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 105 2.2.01.06d.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 106 2.2.01.06d.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 12 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 107 2.2.01.07.i UIN ML18180A090 ML18205A297 Sufficient Information 2.2.01.07.i ICN Not Received 108 2.2.01.07.ii UIN ML19266A636 ML19270E656 Sufficient Information 2.2.01.07.ii ICN Not Received 109 2.2.01.08 UIN ML18019A181 ML18030A794 Sufficient Information ML19135A691 ML19220B678 ML20042E292 2.2.01.08 ICN Not Received 110 2.2.01.09 UIN ML19221B724 ML19225D263 Sufficient Information 2.2.01.09 ICN Not Received 111 2.2.01.10a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 112 2.2.01.10b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 113 2.2.01.10c UIN ML17186A045 ML17285A442 Sufficient Information 2.2.01.10c ICN Not Received 114 2.2.01.11a.i UIN ML18235A302 ML18241A130 Sufficient Information ML17226A034 ML14016A447 ML14016A447 2.2.01.11a.i ICN Not Received 115 2.2.01.11a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 116 2.2.01.11a.iii UIN ML20031D681 ML20034D673 Sufficient Information 2.2.01.11a.iii ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 13 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 117 2.2.01.11a.iv UIN ML19151A640 ML19156A214 Sufficient Information 2.2.01.11a.iv ICN Not Received 118 2.2.01.11b UIN ML18152B741 ML18166A284 Sufficient Information 2.2.01.11b ICN Not Received 119 2.2.02.01 UIN ML17235B093 ML17241A226 Sufficient Information 2.2.02.01 ICN Not Received 120 2.2.02.02a UIN ML18074A041 ML18102A974 Sufficient Information ML18317A395 2.2.02.02a ICN Not Received 121 2.2.02.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 122 2.2.02.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 123 2.2.02.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 124 2.2.02.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 125 2.2.02.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 126 2.2.02.05a.i UIN ML18054A655 ML18072A336 Sufficient Information ML12108A097 ML16357A725 2.2.02.05a.i ICN Not Received 127 2.2.02.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 128 2.2.02.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 14 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 129 2.2.02.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 130 2.2.02.05c UIN ML17276A072 ML18033A086 Sufficient Information Cover sheet is at ML17276A070.

2.2.02.05c ICN Not Received 131 2.2.02.06a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 132 2.2.02.06a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 133 2.2.02.06b UIN ML19200A257 ML19206A014 Sufficient Information 2.2.02.06b ICN Not Received 134 2.2.02.06c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 135 2.2.02.07a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 136 2.2.02.07a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 137 2.2.02.07a.iii UIN ML19304B738 ML19311C424 Sufficient Information 2.2.02.07a.iii ICN Not Received 138 2.2.02.07b.i UIN ML19266A596 ML19275G845 Sufficient Information 2.2.02.07b.i ICN Not Received 139 2.2.02.07b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 140 2.2.02.07b.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 141 2.2.02.07c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 15 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 142 2.2.02.07d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 143 2.2.02.07e.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 144 2.2.02.07e.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 145 2.2.02.07f.i UIN ML19266A623 ML19275F504 Sufficient Information 2.2.02.07f.i ICN Not Received 146 2.2.02.07f.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 147 2.2.02.08a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 148 2.2.02.08b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 149 2.2.02.08c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 150 2.2.02.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 151 2.2.02.10a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 152 2.2.02.10b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 153 2.2.02.10c UIN ML17186A047 ML17285A440 Sufficient Information 2.2.02.10c ICN Not Received 154 2.2.02.11a.i UIN ML18235A313 ML18241A326 Sufficient Information 2.2.02.11a.i ICN Not Received 155 2.2.02.11a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 16 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 156 2.2.02.11a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 157 2.2.02.11b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 158 2.2.03.01 UIN ML18068A089 ML18079A736 Sufficient Information 2.2.03.01 ICN Not Received 159 2.2.03.02a UIN ML18089A363 ML18144B004 Sufficient Information ML16356A258 ML17226A034 ML18045A476 ML18134A348 ML18226A348 ML18317A395 ML19045A614 ML19135A691 ML19220B678 ML19309D596 ML20225A025 ML20315A455 ML112440588 ML14073A652 ML17346A937 2.2.03.02a ICN Not Received 160 2.2.03.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 161 2.2.03.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 162 2.2.03.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 163 2.2.03.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 164 2.2.03.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 17 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 165 2.2.03.05a.i UIN ML18054A413 ML18085B157 Sufficient Information ML18226A348 ML19220B678 ML20315A455 ML12128A072 ML12128A072 ML14231B268 ML15078A379 ML14073A652 ML12313A461 ML16307A159 ML20128J831 ML18102B171 2.2.03.05a.i ICN Not Received 166 2.2.03.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 167 2.2.03.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 168 2.2.03.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 169 2.2.03.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 170 2.2.03.07a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 171 2.2.03.07a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 172 2.2.03.07b UIN ML19225C195 ML19232A211 Sufficient Information 2.2.03.07b ICN Not Received 173 2.2.03.07c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 174 2.2.03.08a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 175 2.2.03.08b.01 UIN ML20126G499 ML20127H961 Sufficient Information 2.2.03.08b.01 ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 18 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 176 2.2.03.08b.02 ICN ML20118C437 ML20120A578 Federal Register Notice Published 85FR29755 ML20225A025 177 2.2.03.08c.i.01 UIN ML17186A132 ML17268A067 Sufficient Information 2.2.03.08c.i.01 ICN Not Received 178 2.2.03.08c.i.02 UIN ML17186A127 ML17269A092 Sufficient Information 2.2.03.08c.i.02 ICN Not Received 179 2.2.03.08c.i.03 UIN ML18120A301 ML18135A158 Sufficient Information ML112440588 ML17346A937 2.2.03.08c.i.03 ICN Not Received 180 2.2.03.08c.i.04 UIN ML18120A264 ML18135A166 Sufficient Information 2.2.03.08c.i.04 ICN Not Received 181 2.2.03.08c.ii UIN ML19050A364 ML19071A298 Sufficient Information 2.2.03.08c.ii ICN Not Received 182 2.2.03.08c.iii UIN ML21068A184 ML21071A145 Sufficient Information 2.2.03.08c.iii ICN Not Received 183 2.2.03.08c.iv.0 1

ICN ML21180A334 ML21182A184 Unconditionally Verified as Completed ML19045A614 ML19220B678 ML20128J831 184 2.2.03.08c.iv.0 2

ICN ML21202A451 ML21207A005 Unconditionally Verified as Completed ML19309D596 185 2.2.03.08c.iv.0 3

ICN ML21167A303 ML21168A092 Unconditionally Verified as Completed Report Print Date: 8/2/2021 7:14:10 AM Page 19 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 186 2.2.03.08c.iv.0 4

ICN ML20118C419 ML20119A866 Federal Register Notice Published 85FR29755 ML20225A025 187 2.2.03.08c.v.01 ICN ML19177A268 ML19189A005 Federal Register Notice Published 84FR55183 ML19220B678 188 2.2.03.08c.v.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 189 2.2.03.08c.vi.0 1

ICN ML15317A057 ML15328A191 Federal Register Notice Published 81FR69553 ML15301A424 190 2.2.03.08c.vi.0 2

ICN ML15048A049 ML15089A314 Federal Register Notice Published 81FR69553 ML15124A857 191 2.2.03.08c.vi.0 3

UIN ML20297A375 ML20302A230 Sufficient Information 2.2.03.08c.vi.0 3

ICN Not Received 192 2.2.03.08c.vii UIN ML18082A335 ML18107A387 Sufficient Information 2.2.03.08c.vii ICN Not Received 193 2.2.03.08c.viii UIN ML18149A395 ML18157A384 Sufficient Information 2.2.03.08c.viii ICN Not Received 194 2.2.03.08c.ix UIN ML17339A433 ML18030A761 Sufficient Information ML18134A348 2.2.03.08c.ix ICN Not Received 195 2.2.03.08c.x UIN ML19269B896 ML19274B833 Sufficient Information ML16245A895 ML17044A539 ML20042E292 2.2.03.08c.x ICN Not Received 196 2.2.03.08c.xi ICN ML16211A157 ML17024A087 Federal Register Notice Published 82 FR 19758 ML15301A424 ML17044A539 Report Print Date: 8/2/2021 7:14:10 AM Page 20 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 197 2.2.03.08c.xii UIN ML18106A790 ML18141A461 Sufficient Information 2.2.03.08c.xii ICN Not Received 198 2.2.03.08c.xiii UIN ML18082A372 ML18107A380 Sufficient Information 2.2.03.08c.xiii ICN Not Received 199 2.2.03.08c.xiv ICN ML18173A030 ML18191B060 Federal Register Notice Published 83FR34890 200 2.2.03.08d ICN ML19206A430 ML19212A672 Federal Register Notice Published 84FR55183 201 2.2.03.09a.i UIN ML18120A282 ML18135A167 Sufficient Information 2.2.03.09a.i ICN Not Received 202 2.2.03.09a.ii UIN ML18117A271 ML18135A161 Sufficient Information 2.2.03.09a.ii ICN Not Received 203 2.2.03.09a.iii ICN ML19288A225 ML19294A315 Federal Register Notice Published 85FR6001 204 2.2.03.09b ICN ML17118A006 ML17144A252 Federal Register Notice Published 82 FR 34992 ML17044A539 205 2.2.03.09c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 139 206 2.2.03.10 UIN ML19240B002 ML19247B962 Sufficient Information 2.2.03.10 ICN Not Received 207 2.2.03.11a.i UIN ML19031A960 ML19043A870 Sufficient Information 2.2.03.11a.i ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 21 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 208 2.2.03.11a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 209 2.2.03.11b.i UIN ML18355A794 ML19010A187 Sufficient Information 2.2.03.11b.i ICN Not Received 210 2.2.03.11b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 211 2.2.03.11b.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 212 2.2.03.11c.i UIN ML18353B211 ML19002A358 Sufficient Information 2.2.03.11c.i ICN Not Received 213 2.2.03.11c.ii UIN ML17186A131 ML18106A743 Sufficient Information 2.2.03.11c.ii ICN Not Received 214 2.2.03.12a.i UIN ML18106A742 ML18109A210 Sufficient Information ML17226A034 ML12158A154 ML13302B397 ML14016A447 ML15152A080 ML15210A806 ML16027A153 ML14016A447 ML18102B171 2.2.03.12a.i ICN Not Received 215 2.2.03.12a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 216 2.2.03.12a.iv UIN ML19161A102 ML19162A200 Sufficient Information 2.2.03.12a.iv ICN Not Received 217 2.2.03.12b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 22 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 218 2.2.03.13 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 219 2.2.04.01 UIN ML18033A047 ML18058A843 Sufficient Information 2.2.04.01 ICN Not Received 220 2.2.04.02a UIN ML18072A155 ML18106A749 Sufficient Information ML20128J831 2.2.04.02a ICN Not Received 221 2.2.04.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 222 2.2.04.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 223 2.2.04.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 224 2.2.04.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 225 2.2.04.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 226 2.2.04.05a.i UIN ML18057A451 ML18078A662 Sufficient Information 2.2.04.05a.i ICN Not Received 227 2.2.04.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 228 2.2.04.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 229 2.2.04.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 230 2.2.04.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 231 2.2.04.07a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 23 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 232 2.2.04.07a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 233 2.2.04.07b UIN ML19210D530 ML19219A220 Sufficient Information 2.2.04.07b ICN Not Received 234 2.2.04.07c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 235 2.2.04.08a.i ICN ML18032A487 ML18043A295 Federal Register Notice Published 83FR34890 236 2.2.04.08a.ii ICN ML18037A885 ML18046B416 Federal Register Notice Published 83FR34890 237 2.2.04.08b.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 238 2.2.04.08b.ii ICN ML15351A404 ML16033A319 Federal Register Notice Published 83FR34890 239 2.2.04.08c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 240 2.2.04.09a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 241 2.2.04.09a.ii UIN ML19162A231 ML19178A305 Sufficient Information 2.2.04.09a.ii ICN Not Received 242 2.2.04.09b.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 243 2.2.04.09b.ii ICN ML16313A504 ML16320A242 Federal Register Notice Published 83FR34890 244 2.2.04.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 245 2.2.04.11a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 246 2.2.04.11b.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 24 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 247 2.2.04.11b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 248 2.2.04.12a.i UIN ML18235A290 ML18257A162 Sufficient Information 2.2.04.12a.i ICN Not Received 249 2.2.04.12a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 250 2.2.04.12a.iii UIN ML19221B718 ML19248C485 Sufficient Information Attachment C, SGS-56A/B should be Steam Generator 2 not 1.

2.2.04.12a.iii ICN Not Received 251 2.2.04.12b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 252 2.2.05.01 UIN ML18033A051 ML18058A840 Sufficient Information 2.2.05.01 ICN Not Received 253 2.2.05.02a UIN ML19177A301 ML19196A099 Sufficient Information 2.2.05.02a ICN Not Received 254 2.2.05.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 255 2.2.05.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 256 2.2.05.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 257 2.2.05.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 258 2.2.05.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 25 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 259 2.2.05.05a.i UIN ML18065A063 ML18078A771 Sufficient Information ML18226A348 ML12108A097 ML16357A725 2.2.05.05a.i ICN Not Received 260 2.2.05.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 261 2.2.05.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 262 2.2.05.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 263 2.2.05.06a UIN ML19224B395 ML19232A235 Sufficient Information 2.2.05.06a ICN Not Received 264 2.2.05.06b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 265 2.2.05.07a.i UIN ML19210D661 ML19218A201 Sufficient Information 2.2.05.07a.i ICN Not Received 266 2.2.05.07a.ii ICN ML18257A055 ML18264A317 Federal Register Notice Published 83FR53321 267 2.2.05.07a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 268 2.2.05.07b.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 269 2.2.05.07b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 270 2.2.05.07c UIN ML19051A082 ML19064A984 Sufficient Information 2.2.05.07c ICN Not Received 271 2.2.05.07d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 26 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 272 2.2.05.08 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 273 2.2.05.09a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 274 2.2.05.09b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 275 2.2.05.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 276 2.2.05.11 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 277 2.2.05.12 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 278 2.3.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 279 2.3.01.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 280 2.3.01.03.i ICN ML16040A246 ML16053A135 Federal Register Notice Published 83FR34890 281 2.3.01.03.ii UIN ML19106A207 ML19114A276 Sufficient Information 2.3.01.03.ii ICN Not Received 282 2.3.01.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 283 2.3.01.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 284 2.3.02.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 285 2.3.02.02a UIN ML18117A305 ML18144B007 Sufficient Information 2.3.02.02a ICN Not Received 286 2.3.02.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 27 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 287 2.3.02.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 288 2.3.02.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 289 2.3.02.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 290 2.3.02.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 291 2.3.02.05.i UIN ML18057A434 ML18079B164 Sufficient Information ML12108A097 ML16357A725 2.3.02.05.i ICN Not Received 292 2.3.02.05.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 293 2.3.02.05.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 294 2.3.02.06a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 295 2.3.02.06a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 296 2.3.02.06b UIN ML19210D483 ML19219B199 Sufficient Information 2.3.02.06b ICN Not Received 297 2.3.02.06c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 298 2.3.02.07a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 299 2.3.02.07b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 300 2.3.02.07c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 28 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 301 2.3.02.08a.i ICN Not Received 2.3.02.08a.i UIN ML19339G167 ML19344A037 Sufficient Information 302 2.3.02.08a.ii ICN ML19079A248 ML19106A140 Federal Register Notice Published 84FR34953 303 2.3.02.08a.iii ICN Not Received 2.3.02.08a.iii UIN ML17244A081 ML17258A087 Sufficient Information 304 2.3.02.08b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 305 2.3.02.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 306 2.3.02.10a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 307 2.3.02.10b.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 308 2.3.02.10b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 309 2.3.02.11a.i ICN Not Received 2.3.02.11a.i UIN ML18235A273 ML18241A129 Sufficient Information ML14016A447 ML14016A447 310 2.3.02.11a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 311 2.3.02.11a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 312 2.3.02.11a.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 313 2.3.02.11b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 314 2.3.02.12a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 29 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 315 2.3.02.12b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 316 2.3.02.13 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 317 2.3.02.14 ICN Not Received 2.3.02.14 UIN ML19310F953 ML19316A455 Sufficient Information 318 2.3.03.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 319 2.3.03.02 ICN Not Received 2.3.03.02 UIN ML21068A243 ML21070A046 Sufficient Information 320 2.3.03.03a ICN ML20357B062 ML20358A144 Federal Register Notice Published 86FR23756 321 2.3.03.03b ICN ML17276A088 ML17290A284 Federal Register Notice Published 83FR34890 322 2.3.03.03c ICN Not Received 2.3.03.03c UIN ML19105B146 ML19112A219 Sufficient Information 323 2.3.03.03d ICN ML18089A296 ML18107A446 Federal Register Notice Published 83FR34890 324 2.3.03.04 ICN Not Received 2.3.03.04 UIN ML19060A187 ML19296D948 Sufficient Information 325 2.3.03.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 326 2.3.04.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 Report Print Date: 8/2/2021 7:14:10 AM Page 30 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 327 2.3.04.02.i ICN Not Received 2.3.04.02.i UIN ML18131A206 ML18143B310 Sufficient Information 328 2.3.04.02.ii ICN Not Received 2.3.04.02.ii UIN ML18275A052 ML18288A228 Sufficient Information 329 2.3.04.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 330 2.3.04.04.i ICN Not Received 2.3.04.04.i UIN ML19177A292 ML19184A041 Sufficient Information 331 2.3.04.04.ii ICN Not Received 2.3.04.04.ii UIN ML18346A039 ML18354A914 Sufficient Information 332 2.3.04.05 ICN Not Received 2.3.04.05 UIN ML19050A395 ML19053A733 Sufficient Information 333 2.3.04.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 334 2.3.04.07 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 335 2.3.04.08 IPCN ML17139C497 ML17163A375 Federal Register Notice Published 84FR34953 IPCN based on issuance of License Amendment No. 58, which revised the acceptance criteria 2.3.04.08 ICN ML16027A264 ML16070A171 Federal Register Notice Published 83FR34890 Report Print Date: 8/2/2021 7:14:10 AM Page 31 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 336 2.3.04.09 IPCN ML17139C523 ML17250A265 Federal Register Notice Published 84FR34953 2.3.04.09 ICN ML16214A250 ML16235A465 Federal Register Notice Published 83FR34890 337 2.3.04.10 ICN Not Received 2.3.04.10 UIN ML19269D625 ML19280A743 Sufficient Information 338 2.3.04.11 ICN Not Received 2.3.04.11 UIN ML18107A676 ML18116A129 Sufficient Information 339 2.3.05.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 340 2.3.05.02.i ICN Not Received 2.3.05.02.i UIN ML18060A011 ML18085A581 Sufficient Information 341 2.3.05.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 342 2.3.05.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 343 2.3.05.03a.i ICN ML19056A456 ML19067A223 Federal Register Notice Published 84FR14980 344 2.3.05.03a.ii IPCN ML20301A851 ML20317A256 Federal Register Notice Published 86FR23756 2.3.05.03a.ii ICN ML20204B029 ML20206K846 Federal Register Notice Published 85FR67017 345 2.3.05.03a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 346 2.3.05.03b.i ICN ML19086A266 ML19094B327 Federal Register Notice Published 84FR34953 347 2.3.05.03b.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 32 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 348 2.3.05.03b.iii ICN Not Received 2.3.05.03b.iii UIN ML19170A326 ML19179A092 Sufficient Information 349 2.3.05.03c.i ICN ML19291D439 ML19295E522 Federal Register Notice Published 85FR6001 Minor error - should be item 3c in the ITAAC statement of the ICN 350 2.3.05.03c.ii ICN Not Received 2.3.05.03c.ii UIN ML19141A305 ML19149A402 Sufficient Information 351 2.3.05.03d.i ICN ML19295E102 ML19297F188 Federal Register Notice Published 85FR6001 Minor error - should be item 3d in the ITAAC statement of the ICN 352 2.3.05.03d.ii ICN Not Received 2.3.05.03d.ii UIN ML19141A337 ML19149A400 Sufficient Information Minor editorial error - ITAAC Statememt, DC, should be 3.d not 3.c 353 2.3.05.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 354 2.3.06.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 355 2.3.06.02a ICN Not Received 2.3.06.02a UIN ML18117A341 ML18141A459 Sufficient Information 356 2.3.06.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 357 2.3.06.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 358 2.3.06.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 359 2.3.06.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 33 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 360 2.3.06.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 361 2.3.06.05a.i ICN Not Received 2.3.06.05a.i UIN ML18054A426 ML18068A215 Sufficient Information ML18226A348 362 2.3.06.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 363 2.3.06.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 364 2.3.06.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 365 2.3.06.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 366 2.3.06.07a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 367 2.3.06.07a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 368 2.3.06.07b ICN Not Received 2.3.06.07b UIN ML19224B478 ML20050D137 Sufficient Information 369 2.3.06.07c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 370 2.3.06.08a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 371 2.3.06.08b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 372 2.3.06.09a.i ICN ML18120A270 ML18151A733 Federal Register Notice Published 83FR34890 373 2.3.06.09a.ii ICN ML18117A424 ML18135A168 Federal Register Notice Published 83FR34890 374 2.3.06.09b.i ICN ML16245A280 ML16271A442 Federal Register Notice Published 83FR34890 Report Print Date: 8/2/2021 7:14:10 AM Page 34 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 375 2.3.06.09b.ii ICN Not Received 2.3.06.09b.ii UIN ML19109A239 ML19116A102 Sufficient Information 376 2.3.06.09b.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 377 2.3.06.09b.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 378 2.3.06.09b.v ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 379 2.3.06.09c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 380 2.3.06.09d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 381 2.3.06.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 382 2.3.06.11a ICN Not Received 2.3.06.11a UIN ML19206A436 ML19213A189 Sufficient Information 383 2.3.06.11b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 384 2.3.06.12a.i ICN Not Received 2.3.06.12a.i UIN ML18235A067 ML18257A164 Sufficient Information ML14016A447 ML14016A447 385 2.3.06.12a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 386 2.3.06.12a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 387 2.3.06.12a.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 388 2.3.06.12b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 35 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 389 2.3.06.13 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 390 2.3.06.14 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 391 2.3.07.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 392 2.3.07.02a ICN Not Received 2.3.07.02a UIN ML18117A296 ML18123A536 Sufficient Information 393 2.3.07.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 394 2.3.07.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 395 2.3.07.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 396 2.3.07.05.i ICN Not Received 2.3.07.05.i UIN ML18054A369 ML18085B154 Sufficient Information ML12108A097 ML16357A725 397 2.3.07.05.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 398 2.3.07.05.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 399 2.3.07.06a ICN Not Received 2.3.07.06a UIN ML19200A256 ML19206A011 Sufficient Information 400 2.3.07.06b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 401 2.3.07.07a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 36 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 402 2.3.07.07b.i ICN Not Received 2.3.07.07b.i UIN ML19141A299 ML19143A335 Sufficient Information 403 2.3.07.07b.ii ICN ML21169A019 ML21175A139 Unconditionally Verified as Completed 404 2.3.07.07b.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 405 2.3.07.07b.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 406 2.3.07.07b.v ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 407 2.3.07.07b.vi ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 408 2.3.07.07c ICN Not Received 2.3.07.07c UIN ML19162A230 ML19175A167 Sufficient Information 409 2.3.07.08.i ICN ML13182A695 ml13204a140 Federal Register Notice Published 83FR34890 410 2.3.07.08.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 411 2.3.07.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 412 2.3.07.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 413 2.3.07.11 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 414 2.3.08.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 415 2.3.08.02.i ICN Not Received 2.3.08.02.i UIN ML19066A215 ML19071A342 Sufficient Information Report Print Date: 8/2/2021 7:14:10 AM Page 37 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 416 2.3.08.02.ii ICN ML16183A028 ML16193A353 Federal Register Notice Published 83FR34890 417 2.3.08.02.iii ICN Not Received 2.3.08.02.iii UIN ML18337A047 ML18347A480 Sufficient Information 418 2.3.08.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 419 2.3.08.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 420 2.3.09.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 421 2.3.09.02a ICN Not Received 2.3.09.02a UIN ML19197A212 ML19204A385 Sufficient Information 422 2.3.09.02b ICN Not Received 2.3.09.02b UIN ML19200A261 ML19206A024 Sufficient Information 423 2.3.09.03.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 424 2.3.09.03.ii ICN Not Received 2.3.09.03.ii UIN ML19105B144 ML19113A149 Sufficient Information 425 2.3.09.03.iii ICN ML19177A266 ML19190A113 Federal Register Notice Published 84FR55183 426 2.3.09.03.iv ICN ML17332A069 ML18010A783 Federal Register Notice Published 83FR34890 427 2.3.09.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 38 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 428 2.3.09.04b ICN Not Received 2.3.09.04b UIN ML19084A073 ML19119A208 Sufficient Information 429 2.3.09.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 430 2.3.10.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 431 2.3.10.02a ICN Not Received 2.3.10.02a UIN ML18032A586 ML18057B040 Sufficient Information 432 2.3.10.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 433 2.3.10.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 434 2.3.10.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 435 2.3.10.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 436 2.3.10.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 437 2.3.10.05a.i ICN Not Received 2.3.10.05a.i UIN ML18106A848 ML18109A234 Sufficient Information 438 2.3.10.05a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 439 2.3.10.05a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 440 2.3.10.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 441 2.3.10.06a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 39 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 442 2.3.10.06b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 443 2.3.10.07a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 444 2.3.10.07a.ii ICN Not Received 2.3.10.07a.ii UIN ML19179A082 ML19190A237 Sufficient Information 445 2.3.10.07b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 446 2.3.10.08 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 447 2.3.10.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 448 2.3.10.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 449 2.3.11.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 450 2.3.11.02.i ICN ML17355A310 ML18025B239 Federal Register Notice Published 83FR34890 451 2.3.11.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 452 2.3.11.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 453 2.3.11.03a ICN ML15211A138 ML15232A673 Federal Register Notice Published 83FR34890 454 2.3.11.03b ICN Not Received 2.3.11.03b UIN ML19151A637 ML19165A272 Sufficient Information 455 2.3.11.03c ICN Not Received 2.3.11.03c UIN ML19130A202 ML19137A151 Sufficient Information Report Print Date: 8/2/2021 7:14:10 AM Page 40 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 456 2.3.12.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 457 2.3.12.02 ICN ML15240A322 ML15314A476 Federal Register Notice Published 83FR34890 458 2.3.13.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 459 2.3.13.02 ICN Not Received 2.3.13.02 UIN ML18051A717 ML18064A234 Sufficient Information 460 2.3.13.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 461 2.3.13.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 462 2.3.13.05.i ICN Not Received 2.3.13.05.i UIN ML18054A652 ML18068A216 Sufficient Information 463 2.3.13.05.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 464 2.3.13.05.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 465 2.3.13.06a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 466 2.3.13.06a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 467 2.3.13.06b ICN Not Received 2.3.13.06b UIN ML19197A217 ML19204A354 Sufficient Information 468 2.3.13.06c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 469 2.3.13.07 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 41 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 470 2.3.13.08 ICN Not Received 2.3.13.08 UIN ML19254D166 ML19260D821 Sufficient Information 471 2.3.13.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 472 2.3.13.10a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 473 2.3.13.10b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 474 2.3.13.11a ICN ITAAC Deleted ITAAC Deleted Per License Amendment Number 10, ML13150A052 475 2.3.13.11b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 476 2.3.13.12 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 477 2.3.14.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 478 2.3.14.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 479 2.3.14.03 ICN ML17205A300 ML18107A804 Federal Register Notice Published 83FR34890 480 2.3.14.04 ICN Not Received 2.3.14.04 UIN ML19053A743 ML19065A065 Sufficient Information 481 2.3.15.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 482 2.3.15.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 483 2.3.15.03 ICN Not Received 2.3.15.03 UIN ML19066A182 ML19078A329 Sufficient Information Report Print Date: 8/2/2021 7:14:10 AM Page 42 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 484 2.3.19.01a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 485 2.3.19.01b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 486 2.3.19.02a ICN Not Received 2.3.19.02a UIN ML19269D844 ML19275D720 Sufficient Information 487 2.3.19.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 488 2.3.29.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 489 2.3.29.02 ICN Not Received 2.3.29.02 UIN ML19304B950 ML19310D333 Sufficient Information 490 2.3.29.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 491 2.3.29.04 ICN Not Received 2.3.29.04 UIN ML19256B964 ML19261A093 Sufficient Information 492 2.4.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 493 2.4.01.02 ICN Not Received 2.4.01.02 UIN ML19085A399 ML19093B518 Sufficient Information 494 2.4.01.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 495 2.4.01.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 496 2.4.02.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 Report Print Date: 8/2/2021 7:14:10 AM Page 43 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 497 2.4.02.02a ICN Not Received 2.4.02.02a UIN ML19085A386 ML19087A066 Sufficient Information 498 2.4.02.02b ICN Not Received 2.4.02.02b UIN ML19260F917 ML19268A203 Sufficient Information 499 2.4.02.02c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 500 2.4.02.03.i ICN ML14113A348 ML14149A334 Federal Register Notice Published 83FR34890 501 2.4.02.03.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 502 2.4.02.03.iii ICN ML14297A477 ML14308A320 Federal Register Notice Published 83FR34890 503 2.4.06.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 504 2.4.06.02 ICN Not Received 2.4.06.02 UIN ML19051A081 ML19053A731 Sufficient Information 505 2.5.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 506 2.5.01.02a ICN Not Received 2.5.01.02a UIN ML19259A307 ML19270E650 Sufficient Information 507 2.5.01.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 508 2.5.01.02c.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 509 2.5.01.02c.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 44 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 510 2.5.01.02d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 511 2.5.01.03a ICN Not Received 2.5.01.03a UIN ML19095B550 ML19106A177 Sufficient Information 512 2.5.01.03b ICN Not Received 2.5.01.03b UIN ML19290H287 ML19296C216 Sufficient Information 513 2.5.01.03c ICN ML16153A096 ML16217A150 Federal Register Notice Published 81FR69553 ML16132A557 514 2.5.01.03d ICN ML17180A033 ML17234A489 Federal Register Notice Published 82 FR 55658 ML17132A345 ML12131A263 ML13318A689 515 2.5.01.03e ICN Not Received 2.5.01.03e UIN ML19106A221 ML19108A305 Sufficient Information 516 2.5.01.03f ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 517 2.5.01.03g ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 518 2.5.01.03h ICN ML16312A369 ML16342C342 Federal Register Notice Published 83FR34890 519 2.5.01.04 ICN Not Received 2.5.01.04 UIN ML19290G511 ML19296C321 Sufficient Information 520 2.5.01.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 521 2.5.02.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 45 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 522 2.5.02.02.i ICN Not Received 2.5.02.02.i UIN ML18078A034 ML18086B733 Sufficient Information ML18226A348 ML19220B678 ML20315A455 523 2.5.02.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 524 2.5.02.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 525 2.5.02.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 526 2.5.02.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 527 2.5.02.05a ICN Not Received 2.5.02.05a UIN ML19161A153 ML19170A183 Sufficient Information 528 2.5.02.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 529 2.5.02.06a.i ICN Not Received 2.5.02.06a.i UIN ML17268A204 ML17304B373 Sufficient Information Cover sheet is at ML17268A203.

530 2.5.02.06a.ii ICN Not Received 2.5.02.06a.ii UIN ML19354A048 ML19361A006 Sufficient Information ML20224A009 ML21041A242 531 2.5.02.06b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 532 2.5.02.06c.i ICN Not Received 2.5.02.06c.i UIN ML19017A282 ML19029B035 Sufficient Information 533 2.5.02.06c.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 46 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 534 2.5.02.07a IPCN Not Received ML17226A034 ML17123A085 ML17123A085 2.5.02.07a ICN ML17093A535 ML17268A062 Federal Register Notice Published 82 FR 55658 ML17226A034 ML17123A085 ML17123A085 535 2.5.02.07b ICN ML16316A009 ML17095A577 Federal Register Notice Published 82 FR 34992 ML17132A345 536 2.5.02.07c ICN ML17152A196 ML17352A740 Federal Register Notice Published 83FR34890 ML18045A476 537 2.5.02.07d ICN ML17060A290 ML17263A488 Federal Register Notice Published 82 FR 55658 ML17226A034 538 2.5.02.07e IPCN Not Received ML17132A345 ML17123A085 ML17123A085 2.5.02.07e ICN ML16351A334 ML17262A650 Federal Register Notice Published 82 FR 55658 ML17132A345 ML17123A085 ML17123A085 539 2.5.02.08a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 540 2.5.02.08a.ii ICN Not Received 2.5.02.08a.ii UIN ML19364A028 ML20013G482 Sufficient Information ML20224A009 541 2.5.02.08a.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 542 2.5.02.08b.i ICN Not Received 2.5.02.08b.i UIN ML19290H171 ML19295G505 Sufficient Information 543 2.5.02.08b.ii ICN Not Received 2.5.02.08b.ii UIN ML20002B640 ML20009F139 Sufficient Information ML20224A009 544 2.5.02.08c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 545 2.5.02.09a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 47 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 546 2.5.02.09b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 547 2.5.02.09c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 548 2.5.02.09d ICN Not Received 2.5.02.09d UIN ML20002B904 ML20013G338 Sufficient Information ML20224A009 549 2.5.02.10 ICN ML19360A221 ML20013D964 Federal Register Notice Published 85FR16388 ML20042E292 550 2.5.02.11 ICN ML20066H205 ML20076A586 Federal Register Notice Published 85FR29755 ML12171A058 ML13207A241 ML13312A316 ML19045A614 ML19220B678 ML20128J831 Note - ICN Reference 4 (Installation Summary Report) has been updated from Rev. 0 to Rev. 1 to provide justification and applicability for a Unit 3 procedure for PMS software installation and regression analysis to Unit 4 (identical process).

551 2.5.02.12 ICN ML19354A051 ML20034D563 Federal Register Notice Published 85FR16388 ML12171A058 ML13207A241 ML13312A316 ML19220B678 552 2.5.02.13 ICN ML15106A606 ML15126A212 Federal Register Notice Published 81FR69553 ML15124A857 553 2.5.02.14 ICN ML17143A244 ML17268A064 Federal Register Notice Published 82 FR 55658 ML17226A034 ML111890000 ML1118900005 ML14058A995 ML14262A351 ML14262A351 ML15363A360 554 2.5.03.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 555 2.5.03.02 ICN Not Received 2.5.03.02 UIN ML19301C966 ML19311C520 Sufficient Information Report Print Date: 8/2/2021 7:14:10 AM Page 48 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 556 2.5.04.01 ICN Not Received 2.5.04.01 UIN ML18059A162 ML18078A098 Sufficient Information 557 2.5.04.02.i ICN Not Received 2.5.04.02.i UIN ML20002B785 ML20013E358 Sufficient Information 558 2.5.04.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 559 2.5.04.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 560 2.5.04.03 ICN Not Received 2.5.04.03 UIN ML19032A580 ML19044A584 Sufficient Information 561 C.2.5.04.04a ICN Not Received C.2.5.04.04a UIN ML19106A261 ML19123A329 Sufficient Information 562 C.2.5.04.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 563 C.2.5.04.04c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 564 2.5.05.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 565 2.5.05.02.i ICN Not Received 2.5.05.02.i UIN ML18054A565 ML18072A335 Sufficient Information 566 2.5.05.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 567 2.5.05.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 49 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 568 2.5.05.03a.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 569 2.5.05.03a.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 570 2.5.05.03b ICN ML20216A594 ML20218A439 Federal Register Notice Published 85FR67017 571 2.5.05.03c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 572 2.5.05.04 ICN Not Received 2.5.05.04 UIN ML19024A431 ML19036A803 Sufficient Information 573 2.5.06.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 574 2.5.06.02 ICN Not Received 2.5.06.02 UIN ML17268A205 ML17276B779 Sufficient Information Cover Sheet is at ML17268A203.

575 2.5.09.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 576 2.5.09.02 ICN ML15317A067 ML15328A183 Federal Register Notice Published 83FR34890 577 2.5.09.03 ICN ML15317A068 ML15328A184 Federal Register Notice Published 83FR34890 578 2.6.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 579 2.6.01.02.i ICN Not Received 2.6.01.02.i UIN ML18067A136 ML18099A157 Sufficient Information 580 2.6.01.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 581 2.6.01.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 50 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 582 2.6.01.03a ICN Not Received 2.6.01.03a UIN ML19193A202 ML19206A030 Sufficient Information 583 2.6.01.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 584 2.6.01.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 585 2.6.01.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 586 2.6.01.04c ICN ITAAC Deleted LA 172 587 2.6.01.04d ICN Not Received 2.6.01.04d UIN ML19028A264 ML19031C936 Sufficient Information 588 2.6.01.04e ICN Not Received 2.6.01.04e UIN ML19329D491 ML19337C168 Sufficient Information 589 2.6.01.04f ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 590 2.6.01.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 591 2.6.01.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 592 2.6.02.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 593 2.6.02.02a ICN Not Received 2.6.02.02a UIN ML18107A723 ML18123A543 Sufficient Information Report Print Date: 8/2/2021 7:14:10 AM Page 51 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 594 2.6.02.02b ICN Not Received 2.6.02.02b UIN ML18107A694 ML18123A547 Sufficient Information 595 2.6.02.02c ICN Not Received 2.6.02.02c UIN ML18127A006 ML18129A414 Sufficient Information 596 2.6.03.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 597 2.6.03.02.i ICN Not Received 2.6.03.02.i UIN ML18078A037 ML18085A637 Sufficient Information ML18226A348 ML19220B678 ML19309D596 ML20315A455 ML21041A242 598 2.6.03.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 599 2.6.03.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 600 2.6.03.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 601 2.6.03.04a ICN Not Received 2.6.03.04a UIN ML19211D226 ML19219B384 Sufficient Information 602 2.6.03.04b ICN ML21032A266 ML21036A107 Federal Register Notice Published 86FR23756 ML20042E292 603 2.6.03.04c ICN Not Received 2.6.03.04c UIN ML19197A223 ML19205A063 Sufficient Information 604 2.6.03.04d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 52 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 605 2.6.03.04e ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 606 2.6.03.04f ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 607 2.6.03.04g ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 608 2.6.03.04h ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 609 2.6.03.04i ICN Not Received 2.6.03.04i UIN ML19234A217 ML19241A388 Sufficient Information 610 2.6.03.05a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 611 2.6.03.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 612 2.6.03.05c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 613 2.6.03.05d.i ICN Not Received 2.6.03.05d.i UIN ML18117A319 ML18144B010 Sufficient Information 614 2.6.03.05d.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 615 2.6.03.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 616 2.6.03.07 ICN Not Received 2.6.03.07 UIN ML18250A157 ML18267A104 Sufficient Information ML20042E292 ML17013A658 ML20042E292 617 2.6.03.08 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 618 2.6.03.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 53 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 619 2.6.03.10 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 620 2.6.03.11 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 621 2.6.04.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 170 622 2.6.04.02a ICN Not Received 2.6.04.02a UIN ML19087A248 ML19092A246 Sufficient Information 623 2.6.04.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 624 2.6.04.02c ICN Not Received 2.6.04.02c UIN ML19059A374 ML19073A218 Sufficient Information 625 2.6.04.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 626 2.6.04.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 627 2.6.05.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 628 2.6.05.02.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 629 2.6.05.02.ii ICN Not Received 2.6.05.02.ii UIN ML19031B390 ML19037A482 Sufficient Information 630 2.6.05.03.i ICN Not Received 2.6.05.03.i UIN ML18036A169 ML18043A242 Sufficient Information 631 2.6.05.03.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 54 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 632 2.6.05.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 633 2.6.05.05.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 634 2.6.05.05.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 635 2.6.05.06.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 636 2.6.05.06.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 637 2.6.06.01.i ICN Not Received 2.6.06.01.i UIN ML19267A221 ML19274C161 Sufficient Information 638 2.6.06.01.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 639 2.6.06.01.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 640 2.6.06.01.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 641 2.6.09.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 642 2.6.09.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 643 2.6.09.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 644 2.6.09.05a ICN Not Received 2.6.09.05a UIN ML19249B862 ML19268A208 Sufficient Information 645 2.6.09.05b ICN ML19330E144 ML19347A428 Federal Register Notice Published 85FR6001 ML19220B678 Report Print Date: 8/2/2021 7:14:10 AM Page 55 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 646 2.6.09.05c ICN Not Received 2.6.09.05c UIN ML19171A341 ML19190A222 Sufficient Information 647 2.6.09.06 ICN Not Received 2.6.09.06 UIN ML18178A557 ML18262A385 Sufficient Information 648 2.6.09.07a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 649 2.6.09.07b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 650 2.6.09.08 ICN Not Received 2.6.09.08 UIN ML18211A622 ML18262A398 Sufficient Information 651 2.6.09.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 652 2.6.09.13a ICN Not Received 2.6.09.13a UIN ML18211A632 ML18262A393 Sufficient Information 653 2.6.09.13b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 654 2.6.09.13c ICN Not Received 2.6.09.13c UIN ML19053A722 ML19077A269 Sufficient Information 655 2.6.09.15a ICN Not Received 2.6.09.15a UIN ML19266A639 ML19274B838 Sufficient Information 656 2.6.09.15b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 56 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 657 2.6.09.16 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 658 C.2.6.09.01 ICN ML17362A019 ML18025C016 Federal Register Notice Published 83FR34890 ML17317A495 ML17317A527 ML18044A209 ML18045A476 659 C.2.6.09.02 ICN Not Received C.2.6.09.02 UIN ML19107A359 ML19129A147 Sufficient Information 660 C.2.6.09.03a ICN Not Received C.2.6.09.03a UIN ML19095B448 ML19106A174 Sufficient Information 661 C.2.6.09.03b ICN Not Received C.2.6.09.03b UIN ML19238A078 ML19268A210 Sufficient Information 662 C.2.6.09.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 663 C.2.6.09.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 664 C.2.6.09.05a ICN Not Received C.2.6.09.05a UIN ML18155A339 ML18200A161 Sufficient Information ML19317E471 665 C.2.6.09.05b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 666 C.2.6.09.06 ICN Not Received C.2.6.09.06 UIN ML18155A226 ML18200A160 Sufficient Information Report Print Date: 8/2/2021 7:14:10 AM Page 57 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 667 C.2.6.09.07 ICN Not Received C.2.6.09.07 UIN ML19240B204 ML19268A206 Sufficient Information 668 C.2.6.09.08a ICN Not Received C.2.6.09.08a UIN ML19084A119 ML19099A228 Sufficient Information ML20044C867 ML21133A105 669 C.2.6.09.08b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 670 C.2.6.09.09 ICN Not Received C.2.6.09.09 UIN ML19066A212 ML19084A142 Sufficient Information 671 C.2.6.12.01 ICN ML19242C624 ML19248C630 Federal Register Notice Published 84FR55183 672 C.2.6.12.02 ICN ML19242C725 ML19248C653 Federal Register Notice Published 84FR55183 673 C.2.6.12.03 ICN ML19240B527 ML19248C224 Federal Register Notice Published 84FR55183 674 C.2.6.12.04 ICN ML19238A102 ML19248C245 Federal Register Notice Published 84FR55183 675 C.2.6.12.05 ICN ML19242D436 ML19274C162 Federal Register Notice Published 84FR55183 ML19309D596 676 C.2.6.12.06 ICN ML19238A149 ML19268A212 Federal Register Notice Published 84FR55183 ML19309D596 677 2.7.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 678 2.7.01.02a ICN Not Received 2.7.01.02a UIN ML18089A349 ML18108A084 Sufficient Information 679 2.7.01.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 58 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 680 2.7.01.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 681 2.7.01.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 682 2.7.01.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 683 2.7.01.04b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 684 2.7.01.05.i ICN Not Received 2.7.01.05.i UIN ML18054A306 ML18058A811 Sufficient Information ML12108A097 ML16357A725 685 2.7.01.05.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 686 2.7.01.05.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 687 2.7.01.06a ICN Not Received 2.7.01.06a UIN ML19193A204 ML19198A122 Sufficient Information 688 2.7.01.06b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 689 2.7.01.07 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 690 2.7.01.08a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 691 2.7.01.08b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 692 2.7.01.08c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 693 2.7.01.08d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 694 2.7.01.09 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 Report Print Date: 8/2/2021 7:14:10 AM Page 59 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 695 2.7.01.10a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 696 2.7.01.10b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 697 2.7.01.11 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 698 2.7.01.12 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 699 2.7.01.13 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 700 2.7.01.14 ICN Not Received 2.7.01.14 UIN ML19198A175 ML19206A078 Sufficient Information 701 2.7.02.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 702 2.7.02.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 703 2.7.02.03a ICN Not Received 2.7.02.03a UIN ML19064A410 ML19071A327 Sufficient Information 704 2.7.02.03b ICN ML17093A300 ML17233A151 Federal Register Notice Published 83FR34890 705 2.7.02.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 706 2.7.02.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 707 2.7.03.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 708 2.7.03.02a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 709 2.7.03.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 60 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 710 2.7.03.03 ICN Not Received 2.7.03.03 UIN ML19151A678 ML19157A062 Sufficient Information 711 2.7.03.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 712 2.7.04.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 713 2.7.04.02a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 714 2.7.04.02b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 715 2.7.04.02c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 716 2.7.04.03 ICN Not Received 2.7.04.03 UIN ML19302D374 ML19311C593 Sufficient Information 717 2.7.04.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 718 2.7.05.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 719 2.7.05.02.i ICN Not Received 2.7.05.02.i UIN ML19151A625 ML19163A234 Sufficient Information 720 2.7.05.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 721 2.7.05.02.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 722 2.7.05.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 723 2.7.06.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 Report Print Date: 8/2/2021 7:14:10 AM Page 61 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 724 2.7.06.02.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 725 2.7.06.02.ii ICN Not Received 2.7.06.02.ii UIN ML19289C319 ML19291C842 Sufficient Information 726 2.7.06.03.i ICN Not Received 2.7.06.03.i UIN ML19304C243 ML19310D583 Sufficient Information 727 2.7.06.03.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 728 2.7.06.03.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 729 2.7.06.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 730 2.7.06.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 731 2.7.07.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 168 732 2.7.07.02 ICN Not Received 2.7.07.02 UIN ML19063B599 ML19065A161 Sufficient Information 733 3.1.00.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 734 3.1.00.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 735 3.1.00.03 ICN Not Received 3.1.00.03 UIN ML18032A222 ML18043A300 Sufficient Information 736 3.1.00.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 Report Print Date: 8/2/2021 7:14:10 AM Page 62 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 737 3.1.00.05 ICN ML17305A012 ML17349A647 Federal Register Notice Published 83FR34890 ML18045A476 738 3.1.00.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 739 3.2.00.01a ICN ML17205A305 ML17234A488 Federal Register Notice Published 82 FR 55658 ML17044A539 740 3.2.00.01b ICN ML17205A293 ML17233A146 Federal Register Notice Published 82 FR 55658 ML17132A345 741 3.2.00.01c.i ICN ML16350A110 ML17137A275 Federal Register Notice Published 82 FR 34992 ML17132A345 742 3.2.00.01c.ii ICN ML18179A072 ML18200A167 Federal Register Notice Published 83FR53321 ML18226A348 743 3.2.00.01d ICN ML18180A103 ML18200A169 Federal Register Notice Published 83FR53321 ML18226A348 744 3.2.00.01e ICN Not Received 3.2.00.01e UIN ML19290H553 ML19311C753 Sufficient Information 745 3.2.00.02 ICN Not Received 3.2.00.02 UIN ML19011A085 ML19016A327 Sufficient Information 746 3.2.00.03.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 747 3.2.00.03.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 748 3.2.00.03.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 749 3.2.00.03.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 750 3.2.00.03.v ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 63 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 751 3.2.00.04 UIN ML19290H055 ML19296C354 Sufficient Information 3.2.00.04 ICN Not Received 752 3.2.00.05 UIN ML17244A043 ML18107A199 Sufficient Information 3.2.00.05 ICN Not Received 753 3.2.00.06.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 754 3.2.00.06.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 755 3.2.00.06.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 756 3.2.00.07 UIN ML19079A138 ML19084A191 Sufficient Information 3.2.00.07 ICN Not Received 757 3.2.00.08 ICN ML16152A109 ML16166A290 Federal Register Notice Published 83FR34890 758 3.2.00.09 UIN ML19169A099 ML19175A199 Sufficient Information 3.2.00.09 ICN Not Received 759 3.3.00.01 UIN ML19143A325 ML19149A398 Sufficient Information 3.3.00.01 ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 64 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 760 3.3.00.02a.i.a UIN ML19326C865 ML19343C810 Sufficient Information ML14121A433 ML14311A666 ML15223B074 ML15301A424 ML16032A554 ML16132A557 ML16210A448 ML16312A506 ML17044A539 ML17132A345 ML17317A527 ML18045A476 ML18134A348 ML18226A348 ML18317A395 ML19045A614 ML19309D596 ML11286A106 ML13042A397 ML15175A446 ML18100A857 ML18101A168 ML18186A573 ML18131A260 3.3.00.02a.i.a ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 65 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 761 3.3.00.02a.i.b UIN ML19326B992 ML19343D794 Sufficient Information ML13312A316 ML14024A594 ML14112A413 ML14218A213 ML15037A406 ML15223B074 ML15301A424 ML16132A557 ML16210A448 ML16312A506 ML17132A345 ML17226A034 ML17317A527 ML18045A476 ML18134A348 ML18226A348 ML19220B678 ML19309D596 ML20042E292 ML20128J831 ML20315A455 ML21041A242 ML11286A106 ML13042A397 ML18186A573 ML18131A260 3.3.00.02a.i.b ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 66 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 762 3.3.00.02a.i.c UIN ML19326B990 ML19343D918 Sufficient Information ML13312A316 ML14024A594 ML14218A213 ML14311A666 ML15037A406 ML15124A857 ML15223B074 ML16032A554 ML16132A557 ML16312A506 ML17044A539 ML17317A527 ML18045A476 ML18134A348 ML18317A395 ML19045A614 ML19135A691 ML19220B678 ML19309D596 ML20042E292 ML20315A455 ML21041A242 ML11286A106 ML13042A397 ML18186A573 ML18131A260 3.3.00.02a.i.c ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 67 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 763 3.3.00.02a.i.d UIN ML19326B963 ML19343D971 Sufficient Information ML13312A316 ML14024A594 ML14218A213 ML14311A666 ML15223B074 ML15301A424 ML16032A554 ML16132A557 ML16210A448 ML16312A506 ML17044A539 ML17132A345 ML17226A034 ML18045A476 ML18134A348 ML18226A348 ML18317A395 ML19135A691 ML19220B678 ML19309D596 ML20042E292 ML21041A242 ML11286A106 ML13042A397 ML17226A340 ML18101A168 ML18186A573 ML18131A260 3.3.00.02a.i.d ICN Not Received 764 3.3.00.02a.ii.a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 765 3.3.00.02a.ii.b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 766 3.3.00.02a.ii.c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 767 3.3.00.02a.ii.d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 768 3.3.00.02a.ii.e UIN ML21182A376 ML21188A213 Sufficient Information 3.3.00.02a.ii.e ICN Not Received 769 3.3.00.02a.ii.f ICN ML21167A295 ML21172A224 Unconditionally Verified as Completed Report Print Date: 8/2/2021 7:14:10 AM Page 68 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 770 3.3.00.02b UIN ML19301D255 ML19308B674 Sufficient Information 3.3.00.02b ICN Not Received 771 3.3.00.02c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 772 3.3.00.02d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 773 3.3.00.02e ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 774 3.3.00.02f UIN ML20022A177 ML20027A177 Sufficient Information ML14311A666 ML15037A406 ML19135A691 3.3.00.02f ICN Not Received 775 3.3.00.02g ICN ML20136A495 ML20147A467 Federal Register Notice Published 85FR67017 ML20225A025 776 3.3.00.02h UIN ML18019A100 ML18046B394 Sufficient Information 3.3.00.02h ICN Not Received 777 3.3.00.03a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 778 3.3.00.03b ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 779 3.3.00.03c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 780 3.3.00.03d ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 781 3.3.00.04a ICN ITAAC Deleted ITAAC Deleted Per License Amendment 165 782 3.3.00.04b ICN ML19364A031 ML20008D551 Federal Register Notice Published 85FR16388 ML20042E292 Minor editorial error - DC should say "operations" 783 3.3.00.04c ICN ITAAC Deleted ITAAC Deleted Per License Amendment 72 Report Print Date: 8/2/2021 7:14:10 AM Page 69 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 784 3.3.00.05a ICN ML20148M265 ML20154K738 Federal Register Notice Published 85FR67017 ML12319A458 ML20225A025 recv'd 5/27/20 785 3.3.00.05b UIN ML19056A447 ML19066A165 Sufficient Information 3.3.00.05b ICN Not Received 786 3.3.00.05c UIN ML18180A097 ML18206A931 Sufficient Information 3.3.00.05c ICN Not Received 787 3.3.00.06a ICN ML20118C603 ML20120A352 Federal Register Notice Published 85FR29755 788 3.3.00.06b ICN ML19291A461 ML19308A036 Federal Register Notice Published 85FR6001 789 3.3.00.07aa UIN ML19291C975 ML19295G632 Sufficient Information ML16210A448 3.3.00.07aa ICN Not Received 790 3.3.00.07ab UIN ML19291D036 ML19295G276 Sufficient Information ML16210A448 ML19309D596 3.3.00.07ab ICN Not Received 791 3.3.00.07ac UIN ML19294A026 ML19296C552 Sufficient Information ML16210A448 3.3.00.07ac ICN Not Received 792 3.3.00.07ba UIN ML18089A294 ML18102A941 Sufficient Information ML16210A448 3.3.00.07ba ICN Not Received 793 3.3.00.07bb UIN ML18095A079 ML18109A222 Sufficient Information ML16210A448 3.3.00.07bb ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 70 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 794 3.3.00.07bc UIN ML18095A095 ML18109A503 Sufficient Information ML16210A448 3.3.00.07bc ICN Not Received 795 3.3.00.07c.i.a UIN ML18177A122 ML18197A227 Sufficient Information 3.3.00.07c.i.a ICN Not Received 796 3.3.00.07c.i.b UIN ML18177A099 ML18197A233 Sufficient Information 3.3.00.07c.i.b ICN Not Received 797 3.3.00.07c.ii.a UIN ML18100A030 ML18156A198 Sufficient Information 3.3.00.07c.ii.a ICN Not Received 798 3.3.00.07c.ii.b UIN ML18177A057 ML18193A538 Sufficient Information 3.3.00.07c.ii.b ICN Not Received 799 3.3.00.07d.i UIN ML18177A145 ML18193A566 Sufficient Information ML16210A448 3.3.00.07d.i ICN Not Received 800 3.3.00.07d.ii.a UIN ML18191B339 ML18200A256 Sufficient Information ML16210A448 Cover letter at ML18191B338 for related ITAAC 3.3.00.07d.ii.a; ITAAC 3.3.00.07d.iii.a; ITAAC 3.3.00.07d.iv.a; and ITAAC 3.3.00.07d.v.a.

3.3.00.07d.ii.a ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 71 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 801 3.3.00.07d.ii.b UIN ML18194A697 ML18206A577 Sufficient Information ML16210A448 Cover letter at ML18194A696 for related ITAAC 3.3.00.07d.ii.b, 3.3.00.07d.iii.b, 3.3.00.07d.iv.b, and 3.3.00.07d.v.b 3.3.00.07d.ii.b ICN Not Received 802 3.3.00.07d.ii.c UIN ML18194A711 ML18219B756 Sufficient Information ML16210A448 Cover letter at ML18194A170 for related ITAAC 3.3.00.07d.ii.c, 3.3.00.07d.iii.c, 3.3.00.07d.iv.c, and 3.3.00.07d.v.c 3.3.00.07d.ii.c ICN Not Received 803 3.3.00.07d.iii.a UIN ML18191B340 ML18200A263 Sufficient Information ML16210A448 Cover letter at ML18191B338 for related ITAAC 3.3.00.07d.ii.a; ITAAC 3.3.00.07d.iii.a; ITAAC 3.3.00.07d.iv.a; and ITAAC 3.3.00.07d.v.a.

3.3.00.07d.iii.a ICN Not Received 804 3.3.00.07d.iii.b UIN ML18194A698 ML18207A502 Sufficient Information ML16210A448 Cover letter at ML18194A696 for related ITAAC 3.3.00.07d.ii.b, 3.3.00.07d.iii.b, 3.3.00.07d.iv.b, and 3.3.00.07d.v.b 3.3.00.07d.iii.b ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 72 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 805 3.3.00.07d.iii.c UIN ML18194A713 ML18221A249 Sufficient Information ML16210A448 Cover letter at ML18194A710 for related ITAAC 3.3.00.07d.ii.c, 3.3.00.07d.iii.c, 3.3.00.07d.iv.c, and 3.3.00.07d.v.c 3.3.00.07d.iii.c ICN Not Received 806 3.3.00.07d.iv.a UIN ML18191B341 ML18200A353 Sufficient Information ML16210A448 Cover letter at ML18191B338 for related ITAAC 3.3.00.07d.ii.a; ITAAC 3.3.00.07d.iii.a; ITAAC 3.3.00.07d.iv.a; and ITAAC 3.3.00.07d.v.a.

3.3.00.07d.iv.a ICN Not Received 807 3.3.00.07d.iv.b UIN ML18194A699 ML18207A911 Sufficient Information ML16210A448 Cover letter at ML18194A696 for related ITAAC 3.3.00.07d.ii.b, 3.3.00.07d.iii.b, 3.3.00.07d.iv.b, and 3.3.00.07d.v.b 3.3.00.07d.iv.b ICN Not Received 808 3.3.00.07d.iv.c UIN ML18194A714 ML18228A642 Sufficient Information ML16210A448 Cover letter at ML18194A710 for related ITAAC 3.3.00.07d.ii.c, 3.3.00.07d.iii.c, 3.3.00.07d.iv.c, and 3.3.00.07d.v.c 3.3.00.07d.iv.c ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 73 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 809 3.3.00.07d.v.a UIN ML18191B342 ML18200A312 Sufficient Information ML16210A448 Cover letter at ML18191B338 for related ITAAC 3.3.00.07d.ii.a; ITAAC 3.3.00.07d.iii.a; ITAAC 3.3.00.07d.iv.a; and ITAAC 3.3.00.07d.v.a.

3.3.00.07d.v.a ICN Not Received 810 3.3.00.07d.v.b UIN ML18194A700 ML18211A352 Sufficient Information ML16210A448 Cover letter at ML18194A696 for related ITAAC 3.3.00.07d.ii.b, 3.3.00.07d.iii.b, 3.3.00.07d.iv.b, and 3.3.00.07d.v.b 3.3.00.07d.v.b ICN Not Received 811 3.3.00.07d.v.c UIN ML18194A715 ML18228A641 Sufficient Information ML16210A448 Cover letter at ML18194A710 for related ITAAC 3.3.00.07d.ii.c, 3.3.00.07d.iii.c, 3.3.00.07d.iv.c, and 3.3.00.07d.v.c 3.3.00.07d.v.c ICN Not Received 812 3.3.00.07e UIN ML19210D676 ML19232A414 Sufficient Information ML16210A448 3.3.00.07e ICN Not Received 813 3.3.00.08 UIN ML17339A419 ML18017A662 Sufficient Information 3.3.00.08 ICN Not Received 814 3.3.00.09 ICN ML14345A948 ML15014A479 Federal Register Notice Published 80FR6551 ML15037A406 Report Print Date: 8/2/2021 7:14:10 AM Page 74 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 815 3.3.00.10.i UIN ML19283A254 ML19295E237 Sufficient Information 3.3.00.10.i ICN Not Received 816 3.3.00.10.ii UIN ML19298A644 ML19303B040 Sufficient Information 3.3.00.10.ii ICN Not Received 817 3.3.00.10.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 818 3.3.00.12 ICN ML18299A180 ML18306A905 Federal Register Notice Published 84FR14980 819 3.3.00.13 UIN ML19130A204 ML19136A393 Sufficient Information ML19135A691 3.3.00.13 ICN Not Received 820 3.3.00.14 UIN ML19130A199 ML19141A156 Sufficient Information ML17044A539 ML17045A764 ML17226A034 ML17226A044 ML18299A326 ML19317E471 3.3.00.14 ICN Not Received 821 3.3.00.16 UIN ML18211A633 ML18262A395 Sufficient Information 3.3.00.16 ICN Not Received 822 3.3.00.17 UIN ML19039A226 ML19077A271 Sufficient Information 3.3.00.17 ICN Not Received 823 3.5.00.01.i UIN ML18065A073 ML18085B139 Sufficient Information 3.5.00.01.i ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 75 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 824 3.5.00.01.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 825 3.5.00.01.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 826 3.5.00.02.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 827 3.5.00.02.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 828 3.5.00.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 829 3.5.00.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 830 3.5.00.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 831 3.5.00.06 UIN ML19169A122 ML19177A280 Sufficient Information ML17132A345 3.5.00.06 ICN Not Received 832 3.5.00.07 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 833 3.5.00.08 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 112 834 3.6.00.01.i ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 835 3.6.00.01.ii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 836 3.6.00.01.iii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 837 3.6.00.01.iv ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 838 3.6.00.01.v ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 839 3.6.00.01.vi ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 Report Print Date: 8/2/2021 7:14:10 AM Page 76 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 840 3.6.00.01.vii ICN ITAAC Deleted ITAAC Deleted Per License Amendment 84 841 3.7.00.01 ICN ML17363A285 ML18051B535 Federal Register Notice Published 83FR6217 ML16312A506 842 C.3.8.01.01 ICN ML18085A015 ML18116A185 Federal Register Notice Published 83FR34890 ML18134A348 843 C.3.8.02.01 ICN ML20220A563 ML20224A074 Federal Register Notice Published 85FR67017 ML17044A539 ML18134A348 844 E.3.8.05.01.01 ICN ML13275A108 ML13319A141 Federal Register Notice Published 78FR73894 ML112232161 ML11259A159 845 E.3.9.01.01.01 UIN ML17262A645 ML17298B061 Sufficient Information E.3.9.01.01.01 ICN Not Received 846 E.3.9.01.01.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 24 847 E.3.9.03.00.01 UIN ML18355A910 ML19015A173 Sufficient Information E.3.9.03.00.01 ICN Not Received 848 E.3.9.03.00.02 UIN ML18355A901 ML19015A282 Sufficient Information E.3.9.03.00.02 ICN Not Received 849 E.3.9.05.01.01 ICN ITAAC Deleted ITAAC Deleted for VEGP Unit 4 as Verified on VEGP Unit 3 850 E.3.9.05.01.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 851 E.3.9.05.01.03 UIN ML17244A542 ML17300B136 Sufficient Information E.3.9.05.01.03 ICN Not Received Report Print Date: 8/2/2021 7:14:10 AM Page 77 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 852 E.3.9.05.01.04 UIN ML19275G497 ML19277H327 Sufficient Information E.3.9.05.01.04 ICN Not Received ITAAC Restored Per License Amendment 158 853 E.3.9.05.01.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 24 854 E.3.9.05.01.06 ICN ITAAC Deleted ITAAC Deleted for VEGP Unit 4 as Verified on VEGP Unit 3 855 E.3.9.05.01.07 ICN ITAAC Deleted ITAAC Deleted for VEGP Unit 4 as Verified on VEGP Unit 3 856 E.3.9.05.01.08 ICN ITAAC Deleted ITAAC Deleted for VEGP Unit 4 as Verified on VEGP Unit 3 857 E.3.9.05.02.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 858 E.3.9.05.02.02 UIN ML17244A572 ML17300B139 Sufficient Information E.3.9.05.02.02 ICN Not Received 859 E.3.9.06.00.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 860 E.3.9.06.00.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 861 E.3.9.06.00.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 862 E.3.9.06.00.04 UIN ML19275G263 ML19277H326 Sufficient Information E.3.9.06.00.04 ICN Not Received 863 E.3.9.06.00.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 864 E.3.9.06.00.06 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 865 E.3.9.07.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 Report Print Date: 8/2/2021 7:14:10 AM Page 78 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 866 E.3.9.07.01.02 UIN ML18339A017 ML18351A246 Sufficient Information E.3.9.07.01.02 ICN Not Received 867 E.3.9.07.01.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 868 E.3.9.07.01.04 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 869 E.3.9.07.01.05 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 94 870 E.3.9.08.01.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 871 E.3.9.08.01.02 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 872 E.3.9.08.01.03 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 873 E.3.9.09.00.01 ICN ITAAC Deleted ITAAC Deleted Per License Amendment 161 874 E.2.5.04.05.05.

01 ICN ML13127A390 ML13162A231 Federal Register Notice Published 78FR38411 ML101241082 ML103130516 ML110460304 ML13127A392 875 E.2.5.04.05.05.

02 ICN ML13154A032 ML13191A333 Federal Register Notice Published 78FR53484 ML110460304 ML13207A241 876 2.6.03.04j ICN ML19344D045 ML19353C904 Federal Register Notice Published 85FR6001 ML20042E292 ITAAC Added Per License Amendment 68 877 2.2.05.09c UIN ML19172A241 ML19183A030 Sufficient Information added per license amendment 107 2.2.05.09c ICN Not Received ITAAC Added Per License Amendment 107 878 2.3.10.11a UIN ML19161A130 ML19169A013 Sufficient Information added per license amendment 106 2.3.10.11a ICN Not Received ITAAC Added Per License Amendment 106 Report Print Date: 8/2/2021 7:14:10 AM Page 79 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number:

ITAAC Index No.

ITAAC No.

ITAAC NOTIFICATION TYPE (ICN, IPCN, UIN)

ITAAC NOTIFICATION NRC CHECKLIST (VEF or UINC)

ITAAC NOTIFICATION REVIEW STATUS FEDERAL REGISTER No.

or NRC LETTER NRC CONSTRUCTION INSPECTION REPORT(S)

NRC VENDOR INSPECTION REPORT(S)

OTHER NOTES 879 2.3.10.12 UIN ML19063B582 ML19065A159 Sufficient Information added per license amendment 106 2.3.10.12 ICN Not Received ITAAC Added Per License Amendment 106 880 2.2.05.07e ICN ML20076A583 ML20080L649 Federal Register Notice Published 85FR29755 ML20128J831 ITAAC added per LA 122 881 2.3.07.07b.vii UIN ML21060B449 ML21061A093 Sufficient Information 2.3.07.07b.vii ICN Not Received ITAAC Added Per LA 126 Report Print Date: 8/2/2021 7:14:10 AM Page 80 Of 80 Plant Name: Vogtle Unit 4 Combined License VOG4 ITAAC Review Status Report Unit Number: