ND-19-0645, Notice of Uncompleted ITAAC 225-Days Prior to Initial Fuel Load Item 2.2.03.12a.iv (Index Number 216)
| ML19161A102 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 06/10/2019 |
| From: | Yox M Southern Nuclear Operating Co |
| To: | Document Control Desk, Office of New Reactors |
| References | |
| ND-19-0645 | |
| Download: ML19161A102 (9) | |
Text
^
Southern Nuclear JUN t 0 2019 Michael J. Vox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel ND-19-0645 10 CFR 52.99(c)(3)
Docket Nos.: 52-025 52-026 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 and Unit 4 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.12a.iv llndex Number 2161 Ladies and Gentlemen:
Pursuant to 10 CFR 52.99(c)(3), Southern Nuclear Operating Company hereby notifies the NRC that as of June 4, 2019, Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Uncompleted Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.2.03.12a.iv [Index Number 216] has not been completed greater than 225-days prior to initial fuel load. The Enclosure describes the plan for completing this ITAAC. Southern Nuclear Operating Company will, at a later date, provide additional notifications for ITAAC that have not been completed 225-days prior to initial fuel load.
This notification is informed by the guidance described in NEI 08-01, Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52, which was endorsed by the NRC in Regulatory Guide 1.215. In accordance with NEI 08-01, this notification includes ITAAC for which required inspections, tests, or analyses have not been performed or have been only partially completed. All ITAAC will be fully completed and all Section 52.99(c)(1) ITAAC Closure Notifications will be submitted to NRC to support the Commission finding that all acceptance criteria are met prior to plant operation, as required by 10 CFR 52.103(g).
This letter contains no new NRC regulatory commitments.
If there are any questions, please contact Tom Petrak at 706-848-1575.
Respectfully submitted, Michael J. Vox Regulatory Affairs Director Vogtle 3 & 4
Enclosure:
Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.2.03.12a.iv [Index Number 216]
MJY/GCW/sfr
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 2 of 3 To:
Southern Nuclear Operating Company/ Georgia Power Company Mr. R. G. West (w/o enclosures)
Mr. D. L. McKinney (w/o enclosures)
Mr. M. D. Meier (w/o enclosures)
Mr. D. H. Jones (w/o enclosures)
Mr. J. B. Klecha Mr. G. Chick Mr. M. J. Vox Mr. A. 8. Parton Ms. K. A. Roberts Mr. T. G. Petrak Mr. W. A. Sparkman Mr. C. T. Defnall Mr. C. E. Morrow Mr. J. L. Hughes Ms. K. M. Stacy Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:
Nuclear Reouiatorv Commission Mr. W. Jones (w/o enclosures)
Mr. F. D. Brown Ms. J. M. Heisserer Mr. C. P. Patel Mr. G. J. Khouri Ms. S. E. Temple Mr. N. D. Karlovich Mr. A. Lerch Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. I. Cozens Mr. J. Gaslevic Mr. V. Hall Qqiethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipai Eiectric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Daiton Utilities Mr. T. Bundros
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 3 of 3 Westinqhouse Electric Company. LLC Dr. L. OrlanI (w/o enclosures)
Mr. D. 0. Durham (w/o enclosures)
Mr. M. M. Corletti Ms. L. G. Iller Ms. J. Monahan Mr. J. L. Coward Other Mr. J. E. Hosier, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.
Dr. W. R. Jacobs, Jr., Ph.D., CDS Associates, inc.
Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernlzan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Baich Bingham
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 1 of 6 Southern Nuclear Operating Company ND-19-0645 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.2.03.12a.iv [index Number 216]
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 2 of 6 ITAAC Statement Desion Commitment 12.a) The squib valves and check valves Identified in Table 2.2.3-1 perform an active safety-related function to change position as indicated in the table.
I nspections/T ests/Analvses iv) Exercise testing of the check valves with active safety functions identified in Table 2.2.3-1 will be performed under preoperational test pressure, temperature, and fluid flow conditions.
Acceptance Criteria iv) Each check valve changes position as indicated in Table 2.2.3-1.
ITAAC Completion Description Multiple ITAAC are performed to verify that the squib valves and check valves identified in Table 2.2.3-1 perform an active safety-related function to change position as indicated in the table.
This ITAAC performs testing of check valves in accordance with preoperational test procedures 3-PXS-ITPP-502 and 4-PXS-ITPP-502 (References 1 and 2), 3-PXS-ITPP-503 and 4-PXS-ITPP-503 (References 3 and 4), 3-PXS-ITPP-506 and 4-PXS-ITPP-506 (References 5 and 6),
and 3-PXS-ITPP-507 and 4-PXS-ITPP-507 (References 7 and 8) to demonstrate each check valve with active safety functions changes position as indicated in VEGP Combined License (COL) Appendix C Table 2.2.3-1 (Attachment A) under preoperational test pressure, temperature, and fluid flow conditions.
References 1 and 2 perform the transfer open testing of the Accumulator Discharge Check Valves (PXS-PL-V028A and -V029A, -V028B and -V029B). The test establishes the initial conditions of the Accumulator Tank (PXS-MT-01 A) as filled and pressurized to greater than 70 pounds per square inch gage (psig) and less than 80 psig, the reactor pressure vessel (RPV) is at atmospheric pressure with the head off and the accumulator outlet valves are closed. During the flow resistance determination testing of the line from the accumulator discharge to the direct vessel injection (DVI) nozzle, the "A" accumulator outlet valves are opened and the "A" accumulator discharges into the RPV through the DVI line. During this testing the flow rate Is measured using a strap-on ultrasonic flow meter (UFM) located as close to the "A" accumulator as possible and based on the flow rate, the Accumulator Discharge Check Valves (PXS-PL-V028A and -V029A) are verified to transfer open when flow rate exceeds 1614 gallons per minute (gpm). This test is repeated for the Accumulator Discharge Check Valves (PXS-PL-V028B and -V029B) during the flow resistance determination testing of the "B" Accumulator discharge through the "B" DVI line. These test flow paths are depicted on drawing SV3-PXS-M6-001, Piping and Instrumentation Diagram (P&ID) Passive Core Cooling System.
References 1 and 2 perform the transfer closed testing of the Nitrogen Supply Containment Isolation Check Valve (PXS-PL-V043). The tests establish the initial conditions of closing the nitrogen supply isolation valve to containment and closing a manual valve downstream of PXS-PL-V043. Temporary air lines are connected to test connections on either side of the PXS-PL-
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 3 of 6 V043 check valve. With the downstream test connection open, the upstream test connection is pressurized with air and V043 is determined to be open by verifying air exits the downstream test connection. The upstream connection is then closed and the air supply is connected to the downstream test connection. The downstream line is then pressurized through the downstream test connection and the test connection upstream of PXS-PL-V043 is opened and the differential pressure causes the PXS-PL-V043 check valve to transfer closed. The upstream test connection is checked for leakage to verify the check valve has transferred closed. These test flow paths are depicted on drawing SV3-PXS-M6-001, P&ID Passive Core Cooling System.
References 3 and 4 perform the transfer closed testing of the Accumulator Discharge Check Valves (PXS-PL-V028A and -V029A, -V028B and -V029B). The test ensures the "A" accumulator discharge lines are filled with water and the accumulator level is at 55% to 56%
- full, the "A" accumulator discharge isolation valves are closed, and one train of Normal Residual Heat Removal System (RNS) is in service recirculating the Reactor Coolant System (RCS) with the RCS Hot Leg level between 48% and 50%. The Passive Core Cooling System (PXS) test panel is utilized to sequentially place RNS pressure on the downstream side of each Accumulator Discharge Check Valve (PXS-PL-V028A and -V029A). When the upstream side of the check valves have depressurized by opening their respective upstream test connection, each check valve is demonstrated to have transferred closed. This test is repeated for the Accumulator Discharge Check Valves (PXS-PL-V028B and -V029B). These test flow paths are depicted on drawing SV3-PXS-M6-001, P&ID Passive Core Cooling System. Testing the transfer open function during pre-operational testing (References 1 and 2) along with testing the transfer closed function during pre-operational testing (References 3 and 4) provides assurance that the Accumulator Discharge Check Valves (PXS-PL-V028A and -V029A, -V028B and -
V029B) have adequately cycled to demonstrate they transfer both open and closed. These test flow paths are depicted on drawing SV3-PXS-M6-001, P&ID Passive Core Cooling System.
References 5 and 6 perform the transfer open function of the Core Makeup Tank (CMT)
Discharge Check Valves (PXS-PL-V016A and -V017A, -V016B and -V017B) during the flow resistance determination testing of the CMT injection line. VEGP Updated Final Safety Analysis Report (UFSAR) subsection 6.3.2.1.3 states that these check valves are normally open with or without flow in the line (i.e., flow out of the CMT and into the DVI injection line). These tests establish the "A" CMT is at approximately 75% level, the RPV is at atmospheric pressure with the head off and the "A" CMT isolation valves are verified to be closed. The "A" CMT isolation valves are then opened and a level rise in the RPV confirms that the "A" CMT Discharge Check Valves (PXS-PL-V016A and -V017A) are open. This testing is repeated on the "B" CMT Discharge Check Valves (PXS-PL-V016B and -V017B). These test paths are depicted on drawing SV3-PXS-M6-001, P&ID Passive Core Cooling System.
References 3 and 4 perform the transfer closed function of the CMT Discharge Check Valves (PXS-PL-V016A and -V017A, -V016B and -V017B). These tests establish the "A" CMT is approximately 75% full and the RPV is at atmospheric pressure with the head installed. PXS-PL-V016A is tested by closing upstream and downstream "A" CMT isolation valves, connecting a demineralized water hose with a flow meter and pressure gauge to a downstream test connection and opening an upstream test connection. A rise in the demineralized water supply pressure and a decrease in flow rate demonstrates that the PXS-PL-V016A Discharge Check Valve transfers closed. This testing is repeated for each of the remaining CMT Discharge Check Valves (PXS-PL-V016B, -V017A and -V017B). These test paths are depicted on drawing SV3-PXS-M6-001, P&ID Passive Core Cooling System. Testing the open function during pre-operational testing (References 5 and 6) along with testing the transfer closed
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 4 of 6 function during pre-operational testing (References 3 and 4) provides assurance that the GMT Discharge Check Valves (PXS-PL-V016A and -V017A, -V016B and -V017B) have adequately cycled to demonstrate they transfer both open and closed.
References 7 and 8 perform the transfer open and transfer closed function of the In-containment Refueling Water Storage Tank (IRWST) Injection Check Valves (PXS-PL-V122A, -V124A,
-V122B and -V124B) during the IRWST flow resistance determination testing of the IRWST injection lines. These tests establish the IRWST level is at 12 to 15 inches, the reactor vessel is fuii to its flange with the head off and venturi flow meter test spools are installed in place of downstream squib valves. The IRWST injection iine "A" motor operated valve (MOV) is opened and obtaining the required flow through each check valve confirms the IRWST Injection Check Valves PXS-PL-V122A and -V124A have transferred open (Note, full open may not occur per LAR 17-009). After check valves PXS-PL-V122A and -V124A are confirmed to be open, IRWST Injection Line "A" MOV is closed and the check valves PXS-PL-V122A and -V124A are confirmed to transfer ciosed by Main Control Room (MCR) indication. This test is repeated for the "B" IRWST Injection Check Valves (PXS-PL-V122B and -V124B). These test paths are depicted on drawing SV3-PXS-M6-002, P&ID Passive Core Cooling System. Performance of pre-operational testing (References 7 and 8) provides assurance that IRWST Injection Check Vaives (PXS-PL-V122A, -V124A, -V122B and -V124B) have adequately cycled to demonstrate they transfer both open and closed.
References 7 and 8 perform the transfer open and transfer closed function of the Containment Recirculation Check Valves (PXS-PL-V119A and -V119B) during the IRWST Screen "A" to Containment Recirculation Sump "A" flow resistance determination testing. These tests establish the IRWST level is at 12 to 15 inches, the reactor vessei is full to its flange with the head off, IRWST sumps are fitted with temporary removable plugs, temporary pipe spools are installed in place of downstream squib vaives and a temporary pipe with a venturi flow meter is installed to cross-connect the containment recirculation sump "A" to "B". The containment recircuiation "A" MOV is opened and IRWST injection line "B" isolation valve is opened and check valve PXS-PL-V119A is confirmed to be closed by MCR indication whiie PXS-PL-V119B is confirmed to be open by system fiow. This test is repeated by opening containment recircuiation "B" MOV and IRWST injection line "A" isolation vaive and confirming PXS-PL-VI19B is closed by MCR indication and PXS-PL-V119A is confirmed to be open by system fiow.
These test paths are depicted on drawing SV3-PXS-M6-002, P&ID Passive Core Cooling System. Performance of pre-operational testing (References 7 and 8) provides assurance that Containment Recircuiation Check Valves (PXS-PL-V119A and -VI19B) have adequately cycled to demonstrate they transfer both open and closed.
References 1 through 8 are available for NRC inspection as part of Unit 3 and Unit 4 iTAAC 2.2.03.12a.iv Compietion Packages (Reference 9 and 10).
List of ITAAC Findings In accordance with piant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant ITAAC findings associated with this ITAAC.
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 5 of 6 References (available for NRC inspection)
- 1. 3-PXS-ITPP-502, "Passive Core Cooling System Acceptance Tesf
- 2. 4-PXS-ITPP-502, "Passive Core Cooling System Acceptance Tesf
- 3. 3-PXS-ITPP-503, "Passive Core Cooling System Acceptance Tesf
- 4. 4-PXS-ITPP-503, "Passive Core Cooling System Acceptance Tesf
- 5. 3-PXS-ITPP-506, "Passive Core Cooling System Acceptance Tesf
- 6. 4-PXS-ITPP-506, "Passive Core Cooling System Acceptance Tesf
- 7. 3-PXS-ITPP-507, "Passive Core Cooling System Acceptance Tesf
- 8. 4-PXS-ITPP-507, "Passive Core Cooling System Acceptance Tesf
- 9. 2.2.03.12a.iv-U3-CP-RevO, ITAAC Completion Package 10.2.2.03.12a.iv-U4-CP-RevO, ITAAC Completion Package
U.S. Nuclear Regulatory Commission ND-19-0645 Enclosure Page 6 of 6 Attachment A
'Excerpt from COL Appendix C Table 2.2.3-1 Equipment Name
- Tag No.
- Active Function*
CMT A Discharge Check Valve PXS-PL-V016A Transfer Open/Transfer Closed CMT B Discharge Check Valve PXS-PL-V016B Transfer Open/Transfer Closed CMT A Discharge Check Valve PXS-PL-V017A Transfer Open/Transfer Closed CMT B Discharge Check Valve PXS-PL-V017B T
ransfer Open/T ransfer Closed Accumulator A Discharge Check Valve PXS-PL-V028A Transfer Open/Transfer Closed Accumulator B Discharge Check Valve PXS-PL-V028B Transfer Open/Transfer Closed Accumulator A Discharge Check Valve PXS-PL-V029A Transfer Open/Transfer Closed Accumulator B Discharge Check Valve PXS-PL-V029B Transfer Open/Transfer Closed Nitrogen Supply Containment Isolation Check Valve PXS-PL-V043 Transfer Closed Containment Recirculation A Check Valve PXS-PL-V119A Transfer Open/Transfer Closed Containment Recirculation B Check Valve PXS-PL-V119B Transfer Open/Transfer Closed IRWST Injection A Check Valve PXS-PL-V122A Transfer Open/Transfer Closed IRWST Injection B Check Valve PXS-PL-V122B T
ransfer Open/T ransfer Closed IRWST Injection A Check Valve PXS-PL-V124A Transfer Open/Transfer Closed IRWST Injection B Check Valve PXS-PL-V124B Transfer Open/Transfer Closed