November 13, 2018 Michael Yox Regulatory Affairs Director Southern Nuclear Operating Company 7835 River Road, Bldg. 140, Vogtle 3 & 4 Waynesboro, GA 30830

SUBJECT:

VOGTLE ELECTRIC GENERATING PLANT, UNITS 3 AND 4 - NRC INTEGRATED INSPECTION REPORTS 05200025/2018003, 05200026/2018003

Dear Mr. Yox:

On September 30, 2018, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at the Vogtle Electric Generating Plant, Units 3 and 4. The enclosed inspection report documents the inspection results, which the inspectors discussed on October 12, 2018 with Mr. J. Klecha and other members of his staff.

The inspection examined a sample of construction activities conducted under your Combined License (COL) as it relates to safety and compliance with the Commissions rules and regulations and with the conditions of these documents. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

The NRC inspectors did not identify any finding or violation of more than minor significance.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.

M. Yox 2

Should you have any questions concerning this letter, please contact us.

Sincerely,

/RA/

Nicole Coovert, Chief (Acting)

Construction Inspection Branch 1 Division of Construction Oversight Docket Nos.: 5200025, 5200026 License Nos: NPF-91, NPF-92

Enclosure:

NRC Inspection Report (IR) 05200025/2018003, 05200026/2018003 w/attachment: Supplemental Information

M. Yox 3

cc:

Office of the Attorney General Resident Inspector 40 Capitol Square, SW Vogtle Plant Units 3 & 4 Atlanta, GA 30334 8805 River Road Waynesboro, GA 30830 Resident Manager Oglethorpe Power Corporation Mr. Barty Simonton Alvin W. Vogtle Nuclear Plant Team Leader 7821 River Road Environmental Radiation Program Waynesboro, GA 30830 Air Protection Branch Environmental Protection Division Southern Nuclear Operating Company, Inc.

4244 International Parkway, Suite 120 Document Control Coordinator Bin N-226-EC Atlanta, GA 30354-3906 3535 Colonnade Parkway Birmingham, AL 35243 George B. Taylor, Jr.

2100 East Exchange Pl Anne F. Appleby Atlanta, GA 30084-5336 Olgethorpe Power Corporation 2100 East Exchange Place Brian H. Whitley Tucker, GA 30084 3535 Colonnade Parkway, Bin N-226-EC 42 Inverness Center Parkway, BIN B237 County Commissioner Birmingham, AL 35243 Office of the County Commissioner Burke County Commission Mr. Michael Yox Waynesboro, GA 30830 Site Regulatory Affairs Director Vogtle Units 3 & 4 Mr. Wayne Guilfoyle 7825 River Road, Bin 63031 Commissioner District 8 Waynesboro, GA 30830 Augusta-Richmond County Commission 4940 Windsor Spring Rd Hephzibah, GA 30815 Gwendolyn Jackson Burke County Library 130 Highway 24 South Waynesboro, GA 30830 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission Atlanta, GA 303

M. Yox 4

Email acchambe@southernco.com (Amy Chamberlian) agaughtm@southernco.com (Amy Aughtman)

ALPUGH@southernco.com (Amanda Pugh) awc@nei.org (Anne W. Cottingham) becky@georgiawand.org (Becky Rafter) bhwhitley@southernco.com (Brian Whitley)

Bill.Jacobs@gdsassociates.com (Bill Jacobs) bjadams@southernco.com (Brad Adams) bwwaites@southernco.com (Brandon Waites) castelca@westinghouse.com (Curtis Castell) comerj@westinghouse.com (James Comer) crpierce@southernco.com (C.R. Pierce) dahjones@southernco.com (David Jones) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis) dgbost@southernco.com (Danny Bost) dlfulton@southernco.com (Dale Fulton) drculver@southernco.com (Randy Culver) durhamdc@westinghouse.com (David Durham) ed.burns@earthlink.net (Ed Burns) edavis@pegasusgroup.us (Ed David) erg-xl@cox.net (Eddie R. Grant) fdhundle@southernco.com (Forrest Hundley) fhwillis@southernco.com (Fred Willis)

G2NDRMDC@southernco.com (SNC Document Control) graysw@westinghouse.com (Scott W. Gray) jadwilli@southernco.com (J.D. Williams) james1.beard@ge.com (James Beard) jannina.blanco@pillsburylaw.com (Jannina Blanco) jantol1dj@westinghouse.com (David Jantosik) jenmorri@southernco.com (Jennifer Buettner)

JHaswell@southernco.com (Jeremiah Haswell) jim@ncwarn.org (Jim Warren)

John.Bozga@nrc.gov (John Bozga)

Joseph_Hegner@dom.com (Joseph Hegner) jpredd@southernco.com (Jason R. Redd) jranalli@meagpower.org (Jerry Ranalli) karen.patterson@ttnus.com (Karen Patterson) karlg@att.net (Karl Gross) kmstacy@southernco.com (Kara Stacy)

KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) lchandler@morganlewis.com (Lawrence J. Chandler) markus.popa@hq.doe.gov (Markus Popa)

M. Yox 5

Matthew.Williams@hq.doe.gov (Matthew Williams) mdmeier@southernco.com (Mike Meier) media@nei.org (Scott Peterson)

Melissa.Smith@Hq.Doe.Gov (Melissa Smith)

Michael.Kuca@hq.doe.gov (Michael Kuca) mike.price@opc.com (M.W. Price)

MKWASHIN@southernco.com (MKWashington) mlgraves@southernco.com (Michelle Graves)

MSF@nei.org (Marvin Fertel) myox@southernco.com (Mike Yox) nirsnet@nirs.org (Michael Mariotte)

Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell)

Paul@beyondnuclear.org (Paul Gunter) pbessette@morganlewis.com (Paul Bessette) r.joshi15@comcast.net (Ravi Joshi)

RJB@NEI.org (Russell Bell)

Ronald.Jones@scana.com (Ronald Jones) rwink@ameren.com (Roger Wink) sabinski@suddenlink.net (Steve A. Bennett) sara@cleanenergy.org (Sara Barczak) sblanton@balch.com (Stanford Blanton)

Shiva.Granmayeh@hq.doe.gov (Shiva Granmayeh) sjackson@meagpower.org (Steven Jackson) skauffman@mpr.com (Storm Kauffman) sroetger@psc.state.ga.us (Steve Roetger) stephan.moen@ge.com (Stephan Moen) stephen.burdick@morganlewis.com (Stephen Burdick) tom.miller@hq.doe.gov (Tom Miller)

TomClements329@cs.com (Tom Clements)

Vanessa.quinn@dhs.gov (Vanessa Quinn) vcsummer2n3@gmail.com (Brian McIntyre) wasparkm@southernco.com (Wesley A. Sparkman) wayne.marquino@gmail.com (Wayne Marquino) weave1dw@westinghouse.com (Doug Weaver) x2gabeck@southernco.com (Gary Becker) x2kmseib@southernco.com (Kristin Seibert

M. Yox 6

Enclosure Letter to Michael Yox from Nicole Coovert dated November 13, 2018.

SUBJECT:

VOGTLE ELECTRIC GENERATING PLANT, UNITS 3 AND 4 - NRC INTEGRATED INSPECTION REPORTS 05200025/2018003, 05200026/2018003 Distribution O. Ayegbusi, NRO F. Brown, NRO R. Patel, NRO W. Jones, NRO V. Hall, RII S. Walker, RII N. Coovert, RII S. Rose, RII B. Adkins, RII A. Artayet, RII P. Carman, RII G. Crespo, RII C. Even, RII B. Griman, RII D. Harmon, RII N. Karlovich, RII B. Kemker, RII G. Khouri, RII A. Lerch, RII J. Lizardi-Barreto, RII K. McCurry, RII T. Nazario, RII S. Smith, RII S. Temple, RII J. Vasquez, RII PUBLIC ADAMS Accession No.: ML18317A395 Publicly Available Non-Sensitive SUNSI Review Complete Form 665 Attached OFFICE DFFI DCO DCO DCO DCO DCO DCO SIGNATURE K. McCurry B. Kemker D. Harmon G. Khouri S. Smith P. Carman G. Crespo DATE 11/13/2018 11/13/2018 11/09/2018 11/09/2018 11/09/2018 11/09/2018 11/09/2018 OFFICE DCO NRO DCO DCO DCO DCO DCO SIGNATURE P. Heher R. Patel J. Vasquez N. Karlovich B. Griman A. Artayet T. Nazario DATE 11/09/2018 11/09/2018 11/09/2018 11/09/2018 11/13/2018 11/13/2018 11/13/2018 OFFICE DCO DCO DFFI DCO DCO SIGNATURE J. Lizardi

/B. Kemker for S. Temple/

/K. McCurry for B. Adkins/

C. Even N. Coovert DATE 11/09/2018 11/13/2018 11/13/2018 11/13/2018 11/13/2018

Enclosure U.S. NUCLEAR REGULATORY COMMISSION Region II Docket Numbers:

5200025 5200026 License Numbers:

NPF-91 NPF-92 Report Numbers:

05200025/2018003 05200026/2018003 Licensee:

Southern Nuclear Operating Company, Inc.

Facility:

Vogtle Unit 3 Combined License Vogtle Unit 4 Combined License Location:

Waynesboro, GA Inspection Dates:

July 1, 2018 through September 30, 2018 Inspectors:

B. Adkins, Senior Fuel Facility Projects Inspector, DFFI A. Artayet, Senior Construction Inspector, DCO P. Carman, Project Manager, DCO G. Crespo, Senior Construction Inspector, DCO B. Griman, Construction Inspector, DCO D. Harmon, Construction Inspector, DCO P. Heher, Construction Inspector, DCO N. Karlovich, Resident Inspector, DCO B. Kemker, Senior Resident Inspector, DCO G. Khouri, Senior Construction Inspector, DCO J. Lizardi-Barreto, Construction Inspector, DCO K. McCurry, Fuel Facility Inspector, DFFI T. Nazario, Senior Test Inspector, DCO R. Patel, Vendor Inspector, DCIP S. Smith, Senior Construction Inspector, DCO S. Temple, Resident Inspector, DCO D. Terry-Ward, Construction Inspector, DCO J. Vasquez, Construction Inspector, DCO Approved by:

Nicole Coovert, Branch Chief (Acting)

Construction Inspection Branch 1 Division of Construction Oversight

SUMMARY

OF FINDINGS Inspection Report (IR) 05200025/2018003, 05200026/2018003; 07/01/2018 through 09/30/2018; Vogtle Electric Generating Plant Units 3 & 4 integrated inspection report.

This report covers a three month period of inspection by resident and regional inspectors, and announced Inspections, Tests, Analysis, and Acceptance Criteria (ITAAC) inspections by resident and regional. The NRCs program for overseeing the construction of commercial nuclear power reactors is described in Inspection Manual Chapter (IMC) 2506, Construction Reactor Oversight Process General Guidance and Basis Document, February 20, 2017.

A. NRC-Identified and Self Revealed Findings None B. Licensee-Identified Violations None

REPORT DETAILS Summary of Plant Construction Status During this report period in Unit 3 containment, SPL modules that make up the columns and floor of the operating deck were installed. In addition, pipe and components that make up the passive core cooling system (PXS) and reactor coolant system (RCS) continued to be installed, including the PRHR HX line, pressurizer surge line and the PXS lines that connect the core makeup tank (CMT), accumulator, and the in-containment refueling water storage tank (IRWST) to the reactor vessel. In the shield building, work completed on the reinforced concrete portion of the shield building below 1596 and the remaining steel composite (SC) transition modules were installed and welded at 14610. In the auxiliary building, floors at 117-6 and walls from 117-6 to 135 were constructed.

In Unit 4 containment, piping work for the PXS and RCS continued to be installed. Rebar that makes up the IRWST floor at 103 was installed in preparation for placing the concrete floor. In the shield building, work continued on the RC and SC portions up to 139-6. In addition, concrete pours underneath the containment vessel (up to 100) were completed. In the auxiliary building, work continued on floors at 100 and work continued on walls from 100 to 117-6.

1.

CONSTRUCTION REACTOR SAFETY Cornerstones: Design/Engineering, Procurement/Fabrication, Construction/Installation, Inspection/Testing Inspection Manual Chapter (IMC) 2503, Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) - Related Work Inspections 1A01 (Unit 3) ITAAC Number 2.1.02.02a (13) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.02.02a (13). The inspectors used the following Nuclear Regulatory Commission (NRC) Inspection Procedures (IPs)/sections to perform this inspection:

65001.06-02.01 - General Installation The inspectors reviewed the pressurizer design specification to verify if the two temporary lifting trunnions bolted to the mid-shell pads were used for rigging and hoisting into the containment vessel to prevent exceeding design loads in accordance with the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC),Section III, Subsections NCA and NB, 1998 Edition including 2000 Addenda.

4 The inspectors reviewed the pressurizer technical manual to determine if the calculated dry weight, measurement location for the center of gravity and handling precautions were in accordance with the design specification for the upending and vertical lift.

The inspectors reviewed the rigging plan to determine if the capacity of both cranes, use of saddles attached to both lifting trunnions, use of steel cable spreader bar, lubrication of the pivot point trunnions for the upending rotation, and weather condition limitations were in accordance with the technical manual. Finally, the inspectors reviewed the rigging plan to verify soil testing, hydraulic functional testing, and load testing were performed prior to lifting the pressurizer in accordance with the "Step by Step Lift Narrative" that included prerequisite and sequential work step signatures.

b. Findings No findings were identified.

1A02 (Unit 3) ITAAC Number 2.1.02.02a (13) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.02.02a (13). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.04-02.01 - General Installation The inspectors reviewed drawings and performed independent measurements of pipe supports in the pressurizer compartment to verify if they were installed in accordance with the ASME Code,Section III, Subsection NF. The inspectors reviewed the following three installed pipe supports:

variable spring support RCS-PH-11V0101 on surge line spool piece 1, constant load support RCS-PH-11C0102 on surge line spool piece 2, and snubber RCS-PH-11Y0103 on surge line-spool piece 3.

The inspectors reviewed the isometric construction drawings for the RCS pipe supports located in the containment building pressurizer compartment to verify if the dimensions and tolerances were in accordance with the Westinghouse Electric Company (WEC) fabrication and installation specification. The inspectors performed a walkdown of the containment building pressurizer compartment to verify if the pipe supports installed were of the correct type, were in the correct location, were properly restrained to the pipe and anchorage point, and were properly aligned in accordance with the pipe support installation construction drawings. During the walkdown, the inspectors independently measured the pipe supports to verify the distance between the center of the RCS-PL-L003 pipe to base plate as well as the distance between the center of the pipe support and the overlay plate joint to CA01 structural module wall met the requirements of the design drawings. Finally, the inspectors examined the pipe supports to verify there was no structural damage and there was no oil leakage from the snubber as required by the WEC fabrication and installation specification.

5

b. Findings No findings were identified.

1A03 (Unit 3) ITAAC Number 2.1.02.02a (13) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.02.02a (13). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.03 - Installation and Welding 65001.B-02.03-Welder Qualification 65001.B-02.05-Inspection 65001.B-02.06-Records The inspectors reviewed quality records associated with manual gas tungsten arc welding (GTAW) on field weld SV3-PXS-PLW-080-5 for line PXS-PL-L130B shown on isometric drawing SV3-PXS-PLW-080 for the automatic depressurization system (ADS) discharge piping to sparger B to determine whether production welding was performed in accordance with the requirements of the qualified welding procedure. The inspectors reviewed the WECTEC weld data sheet to verify quality control (QC) and authorized nuclear inspector (ANI) hold points for visual inspections were signed-off for material identification markings, cleanliness, fit-up, and internal purge/backing gas in accordance with the licensee's procedures. The inspectors reviewed the welder performance qualification records for welders BAP7990, DJK5939, JDC6055, and JJ9039 to verify they were tested and certified in accordance with the requirements of the ASME Code,Section IX.

b. Findings No findings were identified.

1A04 (Unit 3) ITAAC Number 2.2.01.02a (91) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.01.02a (91). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.B-02.06-Records 65001.F-02.02-Fabrication Records Review

6 Sump Discharge Containment Isolation Valve - IRC Valve Tag Location SV3-WLS-PL-V055 The inspectors reviewed procurement and fabrication records associated with the material for the Unit 3 sump discharge containment isolation valve to verify the valve qualification testing and fabrication met the requirements of the WEC design specifications and the ASME Code,Section III. The inspectors reviewed material test records for the valve body, valve bonnet, bonnet studs, bonnet nuts, and plug/stem of the 2 x 2-inch Class 150, air-operated plug valve S/N E2267, Valve Tag number (No.)

SV3-WLS-PL-V055.

The inspectors reviewed the WEC purchase order for the procurement of the plug valve to verify if the quality assurance requirements were specified in accordance with Nuclear Quality Assurance (NQA)-1-1994, and the technical requirements of the WEC design specifications were in accordance with ASME Code,Section III, Division 1.

The inspectors reviewed the certificates of conformance for the valve parts described above to verify the base materials were in compliance with the ASME Code, Sections II and III. The inspectors also reviewed six certified material test reports (CMTRs) to verify the materials were properly heat treated; met the specified chemical, mechanical, impact, and nondestructive testing requirements of the ASME Code,Section II, Parts A and C.

The inspectors reviewed the pressure boundary welds of valve parts described above to verify the welding was performed in accordance with the ASME Code,Section III. The inspectors reviewed the ASME Code Form NPV-1 report to verify if traceability of materials was maintained, the key dimensions met the design, and the valve components were hydrostatically tested at the appropriate design pressure and temperature in accordance with the ASME Code,Section III, Subsection NC. In addition, the inspectors reviewed the ASME Code Form NPV-1 report to verify the ANI authorized the application of the ASME Code symbol stamp in accordance with the ASME Code,Section III, Subarticle NCA-8000. The inspectors reviewed the hydrostatic test report of the valve assembly and the pneumatic seat test reports to verify the test parameters met the acceptance criteria of the WEC design specifications. The inspectors reviewed the vendors production test summary report No. TR-037 to verify the test results and acceptability of test data met the requirements of valve design data report and satisfied the requirements of WEC design specifications.

The inspectors reviewed fabrication records for the valve parts described above to verify the required heat treatment, nondestructive examinations (NDE), and additional tests were performed and the sequence of these activities were conducted to meet the requirements of WEC design specifications and the ASME Code, Sections II and III.

The inspectors reviewed the heat treatment reports to verify the material met the specified mechanical requirements in accordance with the requirements of the ASME Code,Section II, Part A. For NDE, the inspectors reviewed ultrasonic testing (UT) and dye penetrant testing (PT) reports to verify the records were complete and the exam results met the acceptance criteria of the ASME Code,Section V, Articles 5 and 6, respectively.

7 The inspector reviewed the vendor's certificate of compliance to verify the valve was designed, fabricated, and tested to meet the WEC design specifications and the ASME Code,Section III, Subsections NC and NCA-4000.

The inspectors reviewed the final quality data package to verify the records were complete, accurate, reviewed and approved by the responsible organizations, and provided evidence the applicable quality assurance and the ASME Code was satisfied.

The inspectors reviewed nonconformance and deviation reports issued during design and fabrication of valve parts to verify the issues were dispositioned with a technical justification in accordance with NQA-1-1994 Basic Requirements 15 and 16.

SV3-PV14-Z0D-105 Reactor Coolant Drainage Tank Gas Outlet Safety Air Operating Valve IRC V067 The inspectors reviewed procurement and fabrication records associated with material for the reactor coolant drainage tank gas outlet containment isolation valve to verify the valve, qualification testing, and fabrication met the requirements of the applicable WEC design specifications and the ASME Code,Section III. The inspectors reviewed material test records for the valve body, valve bonnet, bonnet studs, bonnet nuts, and plug/stem of the 1 HPNS Globe Valve Class 150, air-operated plug valve S/N 19089917, Valve Tag No. SV3-WLS-PL-V067.

The inspectors reviewed Fisher Controls design report No. 11QN09-DR-02 for the valve to verify the valve parts described above were constructed in accordance with the ASME Code,Section III, Subsection NC. Specifically, the inspectors reviewed a purchase order, fabrication records, and pressure boundary welds.

The inspectors reviewed the WEC purchase order for the procurement of the globe valve to verify it specified the quality assurance requirements in accordance with NQA-1-1994 and technical requirements of the WEC design specifications in accordance with the ASME Code,Section III, Division 1.

The inspectors reviewed six CMTRs to verify the base materials were in compliance with the WEC design specifications. The inspectors reviewed the CMTRs to verify the base metal and weld metals chemical and physical properties were in compliance with the WEC design specifications and the ASME Code,Section II, Parts A, B, and C.

The inspectors reviewed the pressure boundary welds of the valve stem assembly to verify the welding was performed in accordance with the ASME Code,Section III. The inspectors reviewed the ASME Code Form NPV-1 report to verify the ANI authorized the application of the Code symbol stamp in accordance with the ASME Code,Section III, Subarticle NCA-8000. The inspectors also reviewed the hydrostatic test report of the valve assembly and the pneumatic seat test reports to verify the test parameters met the acceptance criteria of the WEC design specifications. The inspectors reviewed the valve assembly production test report to verify the operational test met the test acceptance criteria specified in the WEC design specifications.

The inspectors reviewed fabrication records for the valve parts described above to verify the required heat treatment, NDE, and additional tests were performed and the sequence of these activities were conducted to meet the requirements of WEC design

8 specifications and the ASME Code Sections II and III. The inspectors reviewed six heat treatment reports to verify the material met the specified mechanical requirements in accordance with ASME Code,Section II, Part A. For NDE, the inspectors reviewed UT and PT reports to verify the records were complete and the exam results met the acceptance criteria of the ASME Code,Section V, Articles 5 and 6, respectively.

The inspector reviewed the vendors certificate of compliance to verify the valve was designed, fabricated and tested to meet the WEC design specifications and Article NC-3500 of the ASME Code,Section III.

The inspectors reviewed the final quality data package to verify the records were complete, accurate, reviewed and approved by responsible organizations, and provided evidence the ASME Code requirements were satisfied.

The inspectors reviewed seven nonconformance and deviation reports issued during design and fabrication of valve parts to verify the issues were dispositioned in accordance with NQA-1-1994 Basic Requirements 15 and 16.

b. Findings No findings were identified.

1A05 (Unit 3) ITAAC Number 2.2.01.02a (91) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.01.02a (91). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.B-02.05-Inspection 65001.F-02.02-Fabrication Records Review The inspectors reviewed fabrication records for the fuel transfer tube (FTT) assembly using weld maps to determine whether base and weld materials, examinations, and testing were in accordance with the requirements of the Updated Final Safety Analysis Report (UFSAR), Chapter 3, Table 3.2-3 and the ASME Code Section III, Subsection NE. The inspectors reviewed the WEC ASME Form N-2 code data report to determine it was completed and signed by the ANI in accordance with the ASME Code. The inspectors reviewed nine base metal CMTRs to verify dimensions of the transfer tube, flange, test angle, and hatch with mechanical properties, chemical analysis, and heat treatment were in accordance with the ASME Code provisions and the design specification, APP-FT01-Z0-001, for the FTT. The inspectors reviewed five weld filler metal CMTRs to verify weld filler metal ferrite numbers, mechanical properties, and chemical analysis were as required by the ASME Code Sections III-NE and II-Part C.

The inspectors reviewed two NDE reports to determine if welds were signed by the appropriate level of NDE inspector and were found acceptable in accordance with the ASME Code. The inspectors reviewed test reports for pneumatic, hydrostatic, vacuum

9 box bubble leak, and functional clearance testing to verify contents met the requirements of the design specification, APP-FT01-Z0-001, for the FTT.

b. Findings No findings were identified.

1A06 (Unit 3) ITAAC Number 2.2.01.08 (109) / Family 08F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.01.08 (109). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.08-02.02 - In-Process Installation 65001.08-02.04 - Inspection of Containment Electrical Penetration Assemblies (EPAs) 65001.F-02.04 - General QA Review The inspectors observed installation of various electrical penetration assemblies at different points in the installation process to verify they were installed in accordance with installation manual SV3-EY01-V0M-100. Specifically, the inspectors performed independent measurements, observed in-process installation activities, observed in-process welding, and observed cable feed-through for electrical penetration assemblies SV3-IDSD-EY-P15Y, SV3-ECS-EY-P18X, SV3-IDSC-EY-P27Z, and SV3-ECS-EY-P25W.

For EPA SV3-IDSD-EY-P15Y (containing cables associated with low voltage power functions), the inspectors observed the installation, including the lift, alignment, and set, to verify the penetration was not bent during installation and the installation crew used chain hoists in accordance with the installation manual.

For EPA SV3-ECS-EY-P18X (containing cables associated with low voltage control), the inspectors observed in-process welding of the penetration sleeve to the canister (field weld SV3-ECS-EY-P18X-4) to verify it was welded in accordance with the installation manual and weld procedure 1.1.8T20, Revision 6. The inspectors observed the use of 250 degree Fahrenheit temperature sticks during welding to verify the interpass temperature of the weld did not rise above 250 degrees per the installation manual. The inspectors observed the filler material, voltage, amperage, and direction of the welding were in accordance with weld procedure 1.1.8T20.

For EPA SV3-IDSC-EY-P27Z (containing cables associated with instrumentation and control), the inspectors observed the installation of feed through cables associated with core exit thermocouples to verify the cables were installed in accordance with the installation manual and the specification data sheet for instrumentation and controls penetrations. The inspectors observed the in-process cable pull for cables IIS-EW-GRP4BZC, IIS-EW-GRP5BZC, and IIS-EW-GRP6BZC to verify the identification and

10 placement for each cable were in accordance with the specification data sheet.

Additionally, the inspectors observed the pull to verify fresh grease was used and the cable bend radius was not exceeded during the pull per the penetration installation manual. The inspectors reviewed the qualifications of the quality control inspector performing the inspection to verify he was qualified in accordance with quality assurance procedures.

For EPA SV3-ECS-EY-P25W (containing cables associated with medium voltage power), the inspectors independently measured the installed cables extending from the installed penetration into containment to verify they were sized in accordance with the specification data sheet and drawings for medium voltage power electrical penetration assemblies. Additionally, the inspectors observed the insulation and cones for the cables to verify they were installed in accordance with specification data sheet and drawings.

b. Findings No findings were identified.

1A07 (Unit 3) ITAAC Number 2.2.02.02a (120) / Family 07F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.02.02a (120). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.01 - Purchase and Receipt of Materials 65001.03-02.02 - Storage and Handling 65001.03-02.03 - Installation and Welding 65001.03-02.05 - Pressure Testing 65001.03-02.06 - Nondestructive Examination 65001.03-02.07 - Review of Records 65001.07-02.01 - General Installation 65001.07-02.02 - Component Welding 65001.B-02.02 - Welding Procedure Qualification 65001.B-02.03 - Welder Qualification 65001.B-02.06 - Records 65001.F-02.02 - Fabrication Records Review The inspectors conducted an inspection of Module KB-36, which consists of ASME pipe spools and valves in the passive containment cooling system (PCS). The inspectors performed this inspection to verify KB-36 was fabricated in accordance with ASME BPVC,Section III, WEC design and fabrication specifications, and the UFSAR, Chapter

6. Specifically, the inspectors reviewed fabrication and installation records applicable to the following valves and their associated pipe spools and pipelines:

11 PCS-PL-V005 (4 inch Manual Operated Gate Valve) installed in pipe spool SV3-PCS-PLW-10J-1A, part of line PCS-PL-L048 (Post-72-hour SFS Makeup From Supply Line Connection)

PCS-PL-V015 (1 inch Manual Operated Globe Valve) installed in pipe spool SV3-PCS-PLW-10F-1, part of line PCS-PL-L050 (Post-72-hour Containment Cooling Makeup From Supply Line Connections)

PCS-PL-V039 (4 inch Self-Actuated Check Valve) installed in pipe spool SV3-PCS-PLW-10A-1A, part of line PCS-PL-L051 (Post-72-hour Supply Line Connection)

The inspectors reviewed fabrication records for the valves and pipe spools listed above, including associated pressure boundary welds, to verify the installation was accomplished by qualified personnel and in accordance with approved drawings, qualified procedures, fabrication specifications, and applicable codes and standards.

The inspectors reviewed purchase orders and fabrication specifications to verify quality, technical, material, and regulatory requirements were adequately specified in accordance with 10 Code of Federal Regulations (CFR) Part 21 and Part 50 Appendix B, the ASME Code, the UFSAR, and design specifications.

The inspectors reviewed ASME N-5, NPP-1, and NPV-1 code data reports from the fabricators to determine whether the materials specified and hydrostatic tests performed met the requirements of the ASME code and the design specification. In addition, the inspectors reviewed the data reports to determine if they were signed by an authorized representative of the N-stamp holder and an ANI. The inspectors reviewed the results for the hydrostatic shell test, valve closure and seat leakage test, backseat leakage test, packing leakage test, and operational test recorded in the production test report to verify the required minimum test pressures, holding times, leak rates, and number of times cycled met the requirements listed in the design specification for the valve tested.

The inspectors reviewed the applicable code data reports, weld travelers, and vendor and WEC drawings to verify if the records provided adequate traceability to identify the associated components to the welding procedures, welders, NDE reports, and nonconformance reports used during fabrication. Additionally, the inspectors reviewed all the applicable documents to verify valve and piping materials and welding consumables were of the correct specified type and grade and were uniquely identified by a heat number and markings on the material.

The inspectors reviewed CMTRs to verify if materials were properly heat treated and met the specified chemical, mechanical, and NDE requirements of the ASME Code, Sections II and III, the UFSAR, and WEC design documents. The inspectors also reviewed CMTRs to verify no base material repairs were made without approval from the purchaser in accordance with the ASME Code and WEC fabrication specifications.

The inspectors reviewed a sample of welding procedures to verify the processes and all essential variables used were qualified as required by the ASME Code, Sections III and IX. Specifically, the inspectors reviewed the welding procedures to verify if they were written in accordance with a supporting procedure qualification records (PQR) and the ASME Code,Section IX. In addition, the inspectors reviewed the supporting PQRs to verify the ranges of welding variables were qualified and the qualification tests (both type and number of tests) met the acceptance criteria required by the ASME Code.

12 The inspectors reviewed a sample of welder performance qualification records to determine if the welders were assigned a unique identification number and demonstrated their skill by performing specific performance qualification tests, the qualification testing conditions and qualification limits were fully documented, and the required number of acceptable test results were achieved in accordance with the ASME Code,Section IX, 2007 Edition 2008 Addenda.

The inspectors reviewed reports from visual and liquid penetrant examinations to determine if the welds had been inspected as required by the ASME Code,Section V and found to meet the acceptance criteria of the ASME Code,Section III.

Lastly, the inspectors walked down the module to verify the selected welds did not have any surface defects, the valves were oriented adequately to match their designed flow direction, and the module was stored in accordance with the licensee procedure.

b. Findings No findings were identified.

1A08 (Unit 3) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.06-02.01 - General Installation The inspectors reviewed the core makeup tank B (CMT) design specification to verify if the three vessel lifting lugs located on the top head were used for rigging and hoisting into the containment vessel to prevent exceeding the design loads in accordance with the requirements of the ASME Code,Section III, Subsections NCA and NB.

The inspectors reviewed the CMT B technical manual to determine if the estimated weight and measurement location for the center of gravity were in accordance with the design specification.

The inspectors reviewed the capacity of the crane, use of wire rope slings, and weather conditions in the rigging plan to determine if the rigging plan was in accordance with the technical manual. Finally, the inspectors reviewed the rigging plan to verify load testing was performed prior to lifting the CMT B in accordance with the "Step by Step Lift Narrative" that included prerequisite and sequential work step signatures.

b. Findings No findings were identified.

13 1A09 (Unit 3) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.03 - Installation and Welding 65001.B-02.02-Welding Procedure Qualification 65001.B-02.03-Welder Qualification 65001.B-02.04-Production Controls The inspectors observed installation activities associated with passive core cooling system in-containment refueling water storage tank injection line PXS-L021B.

Specifically, the inspectors observed welding of the line to the direct vessel injection (DVI) line B. The inspectors observed tack and final manual GTAW welding activities for field weld SV3-PXS-PLW-025-1 included in work package SV3-PXS-POW-ME3238 to verify the welding was performed in accordance with the requirements of the ASME Code,Section III, Subsection NB.

The inspectors reviewed the steps of the WDS, including hold point sign-offs by the welder, quality control personnel, and authorized nuclear inspector to verify the sequential steps for activities were in compliance with the ASME Code,Section III, Subsection NB. The inspectors reviewed welding procedure specification (WPS) WPS1-8.8T01 to determine if the essential variables were specified in accordance with the requirements of the ASME Code,Section IX. The inspectors reviewed the weld data sheet included in the work package to verify the welding procedure specification, joint details, traceability of the welder and weld filler material, welding instructions and notes, inspection and NDE procedures, quality control and authorized nuclear inspector hold points, and measuring and test equipment (M&TE) traceability were in accordance with the site welding procedures.

The inspectors observed the intermediate welding passes to verify the interpass temperature, electrical characteristics for amperage, weave and gas techniques, and argon shielding gas requirements were maintained in accordance with the approved welding procedure specification. The inspectors reviewed the welder's performance qualification record to determine if the welder was qualified for the process and weld position in accordance with the ASME Code,Section IX, Article III. The inspectors reviewed weld material requisitions from the rod room and the etchings on the filler metal rods to verify the weld filler material was being properly controlled and traceable to the heat/lot number in accordance with the welding procedure specification. Lastly, the inspectors reviewed the weld filler metal certified material test reports to verify the material properties conformed to the ASME Code,Section II, Part C and were qualified in accordance with the ASME Code,Section III, Subsection NB.

In addition, the inspectors reviewed the NDE results of PT and radiographic testing (RT) for field weld SV3-PXS-PLW-025-1 to verify the records included all the essential

14 variables and the acceptance criteria were documented in accordance with the qualified NDE procedure. The inspectors reviewed the NDE reports to verify the results were reviewed and accepted by a Level II inspector in accordance with the qualified NDE procedure and requirements of the ASME Code,Section III, Subsection NB. The inspectors reviewed the PT and RT procedures to verify the examination techniques and acceptance criteria were in accordance with the requirements of the ASME Code,Section III, Article NB-5000. The inspectors reviewed the qualification and certification records of both Level II PT and RT inspectors to verify their qualifications were in accordance with the ASME Code,Section III, Subarticle NB-5520, "Personnel Qualification, Certification, and Verification." The inspectors reviewed the certification records of the NDE consumables to verify the sulfur and halogen contents were less than 1% by weight in accordance with the requirements of the ASME Code,Section V, Article 6, Paragraph T-640, and Article 24. Finally, the inspectors reviewed calibration records of the M&TE used for NDE inspection to verify the equipment was controlled and calibrated in accordance with the requirements of 10 CFR 50, Appendix B, Criteria XII.

b. Findings No findings were identified.

1A10 (Unit 3) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.06-02.01 - General Installation 65001.A.02.01 - Observation of in-Process Installation Activities 65001.A.02.02 - Installation Records Review The inspectors observed the installation of the passive residual heat removal (PRHR) heat exchanger (HX) to ensure the installation was in accordance with the requirements of the ASME Code,Section III, Subsections NCA and NB, and NQA-1-1994, Part II, Subpart 2.15 for a Category A item.

Prior to the lift, the inspectors observed the surface of the HX to verify there were no signs of physical damage or deterioration during storage in accordance with NQA 1994, Subpart 2.2.

Also, the inspectors reviewed the design specification for the PRHR HX to verify the four lifting lugs on each of the upper and lower parts of the housing structure were used for rigging, rotation, and hoisting into the IRWST to prevent exceeding design loads in accordance with the requirements of the ASME Code Section III, Subsections NCA and NB.

15 The inspectors reviewed the PRHR HX technical manual to determine if the calculated dead weight, location for the center of gravity, and handling precautions were in accordance with the design specification for the upending rotation and vertical lift.

The inspectors reviewed the rigging plan to verify the lift requirements were in accordance with technical manual. Specifically, the inspectors reviewed the rigging plan to verify the two upper lifting lugs on the lower part of the housing structure and the two lower lifting lugs on the upper part of the housing structure were used in tandem for the upending rotation in accordance with the technical manual. The inspectors also determined if the lead and tail cranes, chain hoists, equalizer blocks, and spreader pipe assemblies were used in accordance with the requirements of the technical manual.

The inspectors observed the lifting, movement, and set of the HX to verify the tubes, support skirt, and attached nozzles, were not bumped or damaged in accordance with the rigging plan. During the lift, the inspectors observed the orientation of the HX to verify it met the handling requirements of the rigging plan. In addition, the inspectors observed the lift to verify the HX was level, and the maximum wind speed and temperature were not exceeded in accordance with the rigging plan. Finally, the inspectors reviewed the signature logs included in the rigging plan to verify hold points were observed, quality inspections were completed, and work sequences were maintained in accordance with NQA-1-1994, Part II, Subpart 2.15.

b. Findings No findings were identified.

1A11 (Unit 3) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.B-02.04 - Production Controls 65001.B-02.05 - Inspection The inspectors observed welding and reviewed the associated WDS for field weld SV3-PXS-PLW-042-13 joining 14" diameter stainless steel pipe PXS-PL-L103 to the PRHR HX outlet nozzle to determine whether welding activities were performed in accordance with the requirements of the ASME Code,Section III, Subsection NB, for Class 1 components. Specifically, the inspectors observed manual welding to determine whether interpass cleanliness and use of amperage were in accordance with WPS 1-8.8T01. The inspectors reviewed the WDS to determine whether the weld rod heat numbers and welder identifications were recorded for traceability in compliance with the ASME Code,Section III, Subsection NB. The inspector also reviewed the WDS to determine whether the sequential QC hold point sign-offs for verification of the weld location, fit-up and tack, internal purge/backing gas envelope, and satisfactory results of

16 the final weld surface NDE visual testing (VT) and PT were performed by QC inspectors in accordance with the licensee's quality assurance program.

In addition, the inspectors reviewed WDS SV3-PXS-PLW-042-13-RW for a weld repair performed on the above weld joint to verify welding and inspections of the thru-wall repair area were in compliance with the ASME Code,Section III, Subsection NB-4450, "Repair of Weld Metal Defects." The inspectors reviewed the weld rod heat numbers and welder identifications to verify if traceability to the WDS were in accordance with the quality assurance program. Finally, the inspectors reviewed the repair WDS to verify the hold point sign-offs for visual inspection of the excavated cavity prior to rewelding, final weld surface NDE VT and PT, and volumetric RT were performed by QC inspectors (including the ANI for review of the RT results) in accordance with the quality assurance program.

b. Findings No findings were identified.

1A12 (Unit 3) ITAAC Number 2.2.03.08b.02 (176) / Family 06A

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.08b.02 (176). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.01-02.04 - Key Dimensions and Volumes 65001.A.02.02 - Installation Records Review The inspectors observed the in-process survey of the centerline of the PRHR HX upper channel head to verify the survey was performed in accordance with procedure 26139-000-4MP-T81C-N3201, "Construction Survey," Revision 0.

The inspectors reviewed the survey results for the PRHR HX, the survey results for the RCS hot leg, and a design drawing to verify the difference in centerline elevation of the PRHR HX upper channel was greater than or equal to 26.3 feet higher than the centerline of the RCS hot leg. Specifically, the inspectors independently calculated the results of the survey performed to verify the elevation requirement in Section 6.3.6.1.3 of the UFSAR was satisfied, which requires PXS components were installed in accordance with the accident analyses in Chapter 15 of the UFSAR. The inspectors also reviewed the training of the engineer who translated the field survey data into the survey drawing quality record to verify he was qualified in accordance with the training matrix guidance required by the personnel training and qualification procedure. Additionally, the inspectors inspected the survey equipment to verify the date on the calibration sticker was valid in accordance with the construction survey procedure. The inspectors reviewed procedures NCSP03-06 and NCSP03-24 to verify changes made did not lesson the quality requirements imposed by the previous revision of the procedure.

17

b. Findings No findings were identified.

1A13 (Unit 3) ITAAC Number 2.2.03.08c.iv.04 (186) / Family 03A

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.08c.iv.04 (186). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.01-02.04 - Key Dimensions and Volumes 65001.A - As-Built Attributes for SSCs associated with ITAAC 65001.A.02.02 - Installation Records Review The inspectors observed the in-process survey of the top of the PRHR HX lower channel head and points on the attached PXS pipelines to verify the survey was performed in accordance with survey procedure 26139-000-4MP-T81C-N3201, "Construction Survey," Revision 0. Additionally, the inspectors performed an independent walkdown of the piping to visually verify the pipe going to the steam generator was lower than the PRHR HX lower channel in accordance with the design drawings. The specific line numbers for the piping walked down were PXS-PL-L103, PXS-PL-L104A, PXS-PL-L14B, PXS-PL-L105, and RCS-PL-L113.

The inspectors reviewed the survey results for the piping from the lower channel of the PRHR HX to the steam generator to verify the inside top surface of the piping was lower than the inside top surface of the PRHR HX lower channel in accordance with the accident analysis in the UFSAR, Section 15.2.6.1. Specifically, the inspectors reviewed the field survey results to verify the pipe thickness, cladding thickness, and lower channel head wall thickness taken from reference drawings and standards were properly translated into the survey results from the reference documents. The inspectors independently performed the calculations used in the survey results to verify the PRHR HX lower elevation requirement in Section 15.2.6.1 of the UFSAR was satisfied, which requires the heat exchanger to be located above the core to provide natural circulation flow when the reactor coolant pumps are not operating.

The inspectors also reviewed the training of the engineer who translated the field survey data into the survey drawing quality record to verify he was qualified in accordance with the training matrix guidance required by the licensee's personnel training and qualification procedure.

b. Findings No findings were identified.

18 1A14 (Unit 3) ITAAC Number 2.2.03.08c.v.01 (187) / Family 06A

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.08c.v.01 (187). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.A - As-Built Attributes for SSCs associated with ITAAC 65001.A.02.02 - Installation Records Review 65001.A.02.03 - Independent Assessment/Measurement Inspection The inspectors performed an inspection to verify the elevation of the Unit 3 CMT A with respect to the reactor pressure vessel DVI nozzle satisfied the ITAAC requirement. The inspectors reviewed quality records including the Principal Closure Document and as-built drawings to verify the elevation of the bottom inside tank surface was higher than the DVI nozzle centerline by at least 7.5 feet as specified in Table 2.2.3-4 of Appendix C of the Combined License (COL). The inspectors also reviewed the training of the engineer who translated the field survey data into the survey drawing quality record to verify the individual was qualified in accordance with the training matrix guidance required by the licensee's personnel training and qualification procedure.

The inspectors reviewed drawings and survey results to verify key dimensions and elevations listed met the acceptance criteria in Table 2.2.3-4 of Appendix C of the COL.

In addition, after its placement inside the containment building at elevation 107'-2", the inspectors performed independent measurements of the centerline of the CMT manway cover to the bottom of the tank's feet to verify the as-built dimensions were consistent with the as-built drawings and key dimensional inputs to the licensee's calculation.

b. Findings No findings were identified.

1A15 (Unit 3) ITAAC Number 2.6.03.02.i (597) / Family 08A

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.6.03.02.i (597). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.08-02.03 - Completed Work 65001.F-02.04-General QA Review The inspectors inspected the following partially installed battery racks in the battery rooms on the 66'6" and 82'6" elevations of the auxiliary building:

19 IDSD-DB-1B IDSA-DB-1B IDSS-DB-1B IDSB-DB-2A IDSC-DB-1B The inspectors performed independent measurements of the distance from the racks to the walls to verify the clearance was in accordance with the assembly instructions. The inspectors also measured the welds connecting the racks to the embedment plates on the floor to verify the racks were welded per the embedment plate drawings.

b. Findings No findings were identified.

1A16 (Unit 3) ITAAC Number 3.3.00.02a.i.a (760) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.a (760). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.01-02.05 - Steel Structures 65001.A.02.01 - Observation of in-Process Installation Activities 65001.B-02.01 - Program and Procedures Review 65001.F-02.02 - Fabrication Records Review 65001.F-02.03 - Observation of Fabrication Activities The inspectors performed inspections on structural connections at elevation 107'-0" associated with the steel columns that support the operating floor inside containment at elevation 135'-3". The inspectors observed in-process welding, in-process bolt pre-tensioning tests, and personnel qualification activities. The inspectors reviewed weld records, design drawings, and commercial grade dedication documents.

The inspectors reviewed weld records and observed in-process welding associated with weld Nos. FW-069 and FW-071 on the steel columns for the operating floor inside containment located at elevation 118'-4". The inspectors reviewed WPSs, weld maps, design drawings, design specifications, and weld data sheets to determine if welding parameters were in conformance with clause 3 of American Welding Society (AWS)

D1.1 2000. The inspectors observed in-process welding activities to verify whether interpass temperature, weld position, amperes, volts, and filler metal requirements specified on WPS2-1.1 1S01 were in accordance with procedure 26139-000-4MP-T040-S0021 and clause 3 of AWS D1.1 2000.

The inspectors reviewed documents and observed pre-installation inspections associated with material verification of fastener assemblies to verify whether the type and material characteristics of the connection components were in accordance with

20 procedure NCSP 03-40, AISC-N690-1994, and Section 3.8.4.6 of the UFSAR.

Specifically, the inspectors reviewed design specifications, design and as-built drawings, procedures, and personnel qualification to verify the installation activities were performed in accordance with Section 4.6.2.5 of specification APP-SS01-Z0-001.

The inspectors reviewed pre-installation qualification records associated with American Society for Testing and Materials (ASTM) A325 and A490 bolts to verify the testing process met 70 percent of the specified minimum tensile strength as described in Section 8.1 of the Research Council on Structural Connections. In addition, the inspectors observed a pre-installation qualification test of ASTM A490 bolts using the turn-of-the-nut method and observed qualification activities for personnel performing bolt installation to verify whether the bolt pre-tensioning test was performed in accordance to Section 6.7.7 of NCSP 03-40 and specification APP-SS01-Z0-001.

The inspectors reviewed the CMTR for SPL-18, Sequence III bolting materials.

Specifically, the inspectors reviewed the CMTRs to verify the materials used for the fabrication of A325 bolts, A490 bolts, F436 washers, F959 Direct Tension Indicator (DTI) washers, and A563 nuts met the physical and chemical properties required by the ASTM.

b. Findings No findings were identified.

1A17 (Unit 3) ITAAC Number 3.3.00.02a.i.b (761) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.b (761). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.01-02.05 - Steel Structures 65001.01-02.06 - Records 65001.F-02.03 - Observation of Fabrication Activities The inspectors observed on-going construction activities associated with the Unit 3 shield building reinforced concrete (RC)/ steel composite (SC) horizontal connection located approximately between azimuths 62 and 85 degrees at elevation 146'-10". The inspectors observed the installation of the steel transition horizontal module to the reinforced concrete wall of the shield building and reviewed licensee records including design drawings, specifications, and quality control inspection reports.

The inspectors observed the installations of RC/SC horizontal transition modules 01C and 01D to verify they were performed in accordance with Appendix 3H of the UFSAR.

The inspectors observed construction personnel cleaning and inspecting threads on the vertical reinforcement to verify they were free of any damage, foreign material, and rust in conformance with Section 8.3 of specification APP-CR01-Z0-010. The inspectors

21 observed the installation of the ASTM A563 Grade DH heavy hex nuts and ASTM F436 flat washers onto the No. 11 vertical reinforcement bars installed through the RC/SC support plates to verify they were installed according to design drawings and specification APP-CR01-Z0-010.

The inspectors interviewed quality control personnel and reviewed inspection records associated with the installation of RC/SC modules to verify whether activities affecting quality were verified using appropriate methods and examinations in accordance with ASME NQA-1-1994, Basic Requirement 10. Specifically, the inspectors reviewed procurement documents and the storage requisition report to verify the nuts and washers were made of the required material in accordance with Section 10 of the Bechtel Project Quality Assurance Manual (PNQAM). The inspectors reviewed the structural steel inspection record to verify it was current, accurate, properly completed, and specified an acceptance criteria in accordance with Section 10 of the PNQAM. The inspectors also reviewed the verification of installation record to verify proper installation sequences were followed in accordance with Section 10 of the PNQAM.

b. Findings No findings were identified.

1A18 (Unit 3) ITAAC Number 3.3.00.02a.i.b (761) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.b (761). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A - As-Built Attributes for SSCs associated with ITAAC 65001.A.02.02 - Installation Records Review The inspectors reviewed records, observed testing activities, and performed independent evaluations for the concrete associated with the shield building cylinder from elevation 139'-4" to 149'-2" and approximately between azimuths 73.61 degrees to 180 degrees, including the RC/SC connection at elevation 146'-10". The inspectors performed a record review of the concrete placement and reviewed inspection records, personnel qualifications, and design deviations. Specifically, the inspectors compared the concrete batch tickets against pour card No. 4133 to verify the concrete mix satisfied the design specifications. The inspectors also reviewed the concrete testing records delivered to the intended location to verify they met the strength, slump, air content, mix temperature, and density as required by specification SV3-CC01-Z0-026.

The inspectors reviewed quality control inspection records associated with pre-placement activities to verify whether installed steel reinforcement was clean and free of concrete or grease; rebar was the proper size and had the correct spacing; splices had the proper length; and reinforcement had the proper configuration as required by

22 specification SV3-CC01-Z0-031 and American Concrete Institute (ACI) 349-01. The inspectors reviewed the inspection records to verify whether the concrete placement area was free of debris and foreign materials and the formwork was the correct type; had the correct form release agent applied; and was properly installed without interfering with embedded items in accordance with specification SV3-CC01-Z0-031.

The inspectors reviewed records associated with concrete placement inspections to verify whether quality control inspections were performed during the placement in accordance with Section 4.5 of SV3-CC01-Z0-031. The inspectors reviewed inspection report 26139-SV3-IR-C0-00100 to verify the following requirements were inspected by the licensee in accordance with SV3-CC01-Z0-031 and ACI 349-01:

the proper concrete mix was received; free drop distance for concrete placement was not exceeded; concrete was placed in layers that did not exceed the 18-inch project requirement; vibrating equipment was used with the proper insertion to the previous placed layer to consolidate the mix; concrete was tested at the required frequency and the results recorded; batch tickets were accounted for and recorded; and the concrete placement card was reviewed for completeness and acceptance of field test results.

The inspectors reviewed inspection qualification records to verify if quality control inspectors had been adequately trained and certified for the inspection of concrete placement activities in accordance with NQA1-1994, Subpart 2.5 and the Bechtel Project Nuclear Quality Control Manual (PNQCM). The inspectors also reviewed nonconformance and condition reports associated with the concrete placement to verify whether nonconformances were documented, evaluated, and dispositioned in accordance with procedure APP-GW-GAP-428.

The inspectors observed the 28-day compressive strength testing of six cylindrical concrete specimens to verify the test method used was in accordance with NQA-1-1994, ASTM C39/C39M, and specification SV3-CC01-Z0-027 section 6.1.12, "Concrete Testing during Placement." Additionally, during the testing activities, the inspectors observed the tests to verify they were within the allowable time frame, and were done using an appropriate test machine in accordance with ASTM C39/C39M.

The inspectors checked the testing machine to verify the type, capacity, load indication displays, and allowable accuracy was in accordance with ASTM C39/C39M. The inspectors reviewed the calibration record for the test machine to verify the load capacity, rate, and accuracy were confirmed by the licensee within the time allowed by ASTM C39/C39M. The inspectors observed the technician confirm the bearing blocks and spacers used for testing to verify they were of the correct material, shape, size, and dimensions for the concrete cylinders being tested in accordance with ASTM C39/C39M.

The inspectors also independently verified the attributes of the bearing blocks and spacers used for testing. The inspectors reviewed the calibration record for the bearing blocks and spacers to verify material, shape, size, and dimensions were demonstrated by the licensee within the time allowed by ASTM C39/C39M.

23 The inspectors observed the technician prepare the bearing blocks, spacers, specimens, and test machine prior to running each test to verify the tests were set up in accordance with ASTM C39/C39M. The inspectors observed the test machine setup, including installation of the bearing blocks, spacers, and specimens to verify the machine was prepared and set up in accordance with ASTM C39/C39M. The inspectors independently checked and observed the technician confirm the axial alignment of the cylinders before and during axial loading to verify the load was applied in the manner required by ASTM C39/C39M.

The inspectors observed the application of the compressive axial load to the cylinder specimens to verify the tests were performed in accordance with ASTM C39/C39M and specification SV3-CC01-Z0-027 section 6.1.12. The inspectors observed the rate of loading and continuous application of load to verify the load was applied in the method specified in ASTM C39/C39M. The inspectors observed and independently assessed the fracture pattern type of each cylinder after removal from the test machine to verify the technician correctly identified and documented them on the test reports in accordance with ASTM C39/C39M.

The inspectors observed the curing conditions; reviewed the curing area logs; and observed the storage conditions for the cylinders prior to testing to verify they were kept within the temperature and moisture conditions specified in ASTM C39/C39M, ASTM C31/C31M, and SV3-CC01-Z0-027 section 6.1.12. The inspectors observed the technician verify and record the dimensions and perpendicularity of the test specimens to verify these properties were determined using the method described in ASTM C39/C39M. The inspectors independently calculated the cross-sectional area of the cylinder specimens to verify the areas recorded by the technician were in accordance with ASTM C39/C39M.

The inspectors reviewed the test reports and associated concrete batch tickets for the concrete cylinder strength testing observed to verify the records were complete, accurate, and contained the required information in accordance with NQA-1-1994, ASTM C39/C39M, and specification SV3-CC01-Z0-027 section 6.1.12. Additionally, the inspectors reviewed the test results to verify they met the strength requirements for the specified concrete mix in accordance with specification SV3-CC01-Z0-026 section 4.2.10, "Concrete Mix Design."

b. Findings No findings were identified.

1A19 (Unit 3) ITAAC Number 3.3.00.02a.i.b (761) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.b (761). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.01-02.05 - Steel Structures

24 65001.B-02.02 - Welding Procedure Qualification 65001.B-02.03 - Welder Qualification 65001.B-02.04 - Production Controls 65001.B-02.05 - Inspection The inspectors reviewed documents for two vertical seam welds on the east side of the shield building for the horizontal transition modules at the 146'-10" elevation to verify compliance with the requirements of the AWS D1.1-2000 code and WEC specification APP-1208-Z0-001 for fracture toughness. The inspectors reviewed weld travelers for joining the 1A to 1B and 1C to 1D panels to verify hold points were signed-off by QC for fit-up and tack welding, magnetic particle testing (MT) of temporary attachment removal areas, and final weld seam VT and 10% spot volumetric UT. The inspectors reviewed two WPSs for impact testing and fifteen welder certification records for six welders to verify testing was performed in accordance with the requirements of ASME Section IX for use of the shielded metal arc welding (SMAW) and flux-cored arc welding (FCAW) processes. The inspectors reviewed CMTRs for the following three weld filler materials to verify chemical analysis and mechanical properties with impact testing were performed in accordance with the requirements of the AWS material specifications:

SMAW E8018-C1 H4R (lot-no. 1332R) of A5.5, FCAW E71T-1M/-9M (lot-no. 1186B) of A5.20, and FCAW E71T-1M-J (lot-no. 1329B) of A5.20.

The inspectors reviewed three MT reports for inside/outside surface inspections of temporary attachment and backup bar removal areas for both vertical seam welds to verify inspections were performed in accordance with the requirements of AWS D1.1-2000, Section 6, Inspection. The inspectors reviewed four UT reports for inside/outside 10% spot volumetric inspections of both vertical seam welds to verify inspections were performed in accordance with the requirements of AWS D1.1-2000, Section 6.

The inspectors reviewed N&D SV3-1208-GNR-000099 and engineering and design coordination reports (E&DCR) E&DCR-1208-GEF-211 to verify rework of interfering rebar and backup bar to facilitate weld joint alignment of the 01C/01D panels within acceptable limits were appropriately evaluated, approved, and dispositioned in accordance with applicable technical and quality assurance requirements. The inspectors reviewed an associated weld traveler to verify hold points were signed-off by QC for mapping rework locations and welding of tie bar splices with VT and MT inspections of completed welds. The inspectors reviewed an MT report for a 10% spot surface MT of the final weld on a 01C/01D tie bar splice plate to verify inspection was performed in accordance with AWS D1.1-2000, Section 6.

b. Findings No findings were identified.

25 1A20 (Unit 3) ITAAC Number 3.3.00.02a.i.b (761) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.b (761). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.01-02.06 - Records 65001.A.02.01 - Observation of in-Process Installation Activities 65001.A.02.02 - Installation Records Review 65001.A.02.04 - Review As-built Deviations/Nonconformance 65001.B-02.05 - Inspection 65001.F-02.03 - Observation of Fabrication Activities The inspectors performed inspection activities associated with the assembly of shield building panels located at EL. 149' 6" between azimuths 62.5 and 152.5. The inspectors observed in-process welding of vertical and horizontal seams, reviewed design drawings and documentation associated with welding activities, and reviewed welder qualifications.

The inspectors performed inspection of construction activities associated with vertical seam welds between panels 07A and 07B and panels 07B and 07C, and the horizontal seam weld between panels 07C/07D and 01D/01E. The inspectors observed weld-joint preparation and fit-up of vertical and horizontal welds to determine if the configuration was in conformance with approved as-built design drawings and Clause 4, "Qualification," of AWS D1.1 2000.

The inspectors reviewed the following to determine if the documents and applicable essential variables were in accordance with the requirements of Clause 4 of AWS D1.1 2000:

PQRs, material distribution logs, traveler documents, SMAW and FCAW processes, welding position, type of base metal, type of filler metal, and process parameters such as amperage, current, voltage, and travel speed.

The inspectors observed in-process welding of vertical and horizontal seams to ensure the welds complied with the requirements established in the WPS. Specifically, the inspectors observed in-process welding of one vertical seam, 07A and 07B, and two horizontal seams to verify work was performed in accordance with WPS 181816-000-WS-SP-E71T1. The inspectors also sampled four welder qualification records to verify the welders were qualified for the welding processes used to assemble the shield building panels in accordance with the general welding procedures and Clause 4 of AWS D1.1 2000.

26 The inspectors reviewed NDE records of welds on the vertical seam joining panels 07A-07B, welds on the circumferential horizontal seam between panels 07C and transition panels 01C/01D, and the weld on the horizontal seam between panels 07D and transition panels 01D/01E. Specifically, the inspectors reviewed traveler documents and UT reports to determine if welds were performed in accordance with procedure 181816-000-WS-PR-45054 and Clause 6, "Inspection," of AWS D1.1 2000.

The inspectors sampled seven E&DCRs to verify the licensee was controlling design changes associated with the joint configuration of shield building panel welds in accordance with NQA1-1994, Basic Requirement 3 and Supplement 3S-1.

b. Findings No findings were identified.

1A21 (Unit 3) ITAAC Number 3.3.00.02a.i.c (762) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.c (762). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A - As-Built Attributes for SSCs associated with ITAAC 65001.A.02.01 - Observation of in-Process Installation Activities 65001.A.02.03 - Independent Assessment/Measurement Inspection 65001.A.02.04 - Review As-built Deviations/Nonconformance The inspectors performed inspection of construction activities associated with the main control room floor located between column lines 9.2 to 11 and column lines I to L at elevation 117'-6" in the auxiliary building. The inspectors observed ongoing reinforcement installation activities and reviewed licensee records including design specifications, design drawings, and E&DCRs.

The inspectors performed independent measurements of steel reinforcement bars in the floor to verify they were installed in accordance with ACI 349-01. Specifically, the inspectors conducted in-field measurements of installed top and bottom layers of reinforcing steel to verify they met size and spacing requirements; had minimum concrete clear cover; lap splices met the minimum length; and the floor had the required thickness in accordance with design drawings.

The inspectors observed reinforcement installation activities to verify they were performed using the latest approved design changes, design drawings, and quality control procedures in accordance with NQA-1 1994, Basic Requirements 3 and 5.

27 The inspectors reviewed quality records and observed concrete placement activities associated with the main control room floor. Specifically, the inspectors reviewed concrete pour card No. 4246 to determine whether concrete mix design requirements were properly translated into quality assurance documents in accordance with design specification SV3-CC01-Z0-026. During placement, the inspectors also compared the pour card to the batch tickets to verify concrete delivered to the site had the appropriate concrete mix type. The inspectors reviewed the batch tickets during concrete placement to verify transport time was completed within the time allowed by ACI 349-01 and the delivery was intended for the proper location in accordance with the pour card. The inspectors observed concrete placement activities to determine whether placement drop distances met requirements specified in section 4.2.4 of specification SV3-CC01-Z0-031.

The inspectors also observed the use of concrete vibrators to verify they were handled and operated to ensure adequate consolidation of the mix in accordance with section 4.2.9 of specification SV3-CC01-Z0-031.

The inspectors reviewed calculation CALC-VMD-026 associated with the laboratory mix trials for safety related, self-consolidating concrete mixes. The inspectors reviewed the calculations to verify the self-consolidated concrete mixes were able to reach the minimum bulk dry density requirement of 140 pounds per cubic feet as described in Section 12.3.2.2 of the UFSAR.

b. Findings No findings were identified.

1A22 (Unit 3) ITAAC Number 3.3.00.02a.i.c (762) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.c (762). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.02 - Laboratory Testing 65001.02-02.06 - Record Review 65001.A.02.03 - Independent Assessment/Measurement Inspection The inspectors observed testing activities, performed independent evaluations, and reviewed records for the concrete associated with the auxiliary building at column line 11 from column line L to Q from elevation 117'-6" to 135'-3", including the north walls of both main steam isolation valve compartments. The inspectors observed the 28-day compressive strength testing of six cylindrical concrete specimens to verify the test method used was in accordance with ASTM C39/C39M, and specification SV3-CC01-Z0-027 section 6.1.12, "Concrete Testing during Placement." Additionally, the inspectors observed the testing activities to verify they were performed by a qualified concrete laboratory test technician; were within the allowable time frame; and were done using an appropriate test machine in accordance with ASTM C39/C39M.

28 The inspectors independently inspected the testing machine to verify the type, capacity, load indication displays, and accuracy were in accordance with ASTM C39/C39M. The inspectors reviewed the calibration record for the test machine to verify the load capacity, rate, and accuracy were confirmed by the licensee within the time allowed by ASTM C39/C39M. The inspectors independently observed the technician confirm the bearing blocks and spacers used for testing to verify they were of the correct material, shape, size, and dimensions for the concrete cylinders being tested in accordance with ASTM C39/C39M. The inspectors reviewed the calibration record for the bearing blocks and spacers to verify material, shape, size, and dimensions were demonstrated by the licensee within the time allowed by ASTM C39/C39M.

The inspectors observed the curing conditions; reviewed the curing area logs; and observed the storage conditions for the cylinders to verify they were kept within the temperature and moisture conditions specified in ASTM C39/C39M, ASTM C31/C31M, and SV3-CC01-Z0-027, Section 6.1.12. The inspectors observed the technician verify and record the dimensions and perpendicularity of the test specimens to verify these properties were determined using the method described in ASTM C39/C39M. The inspectors independently calculated the cross-sectional area of the cylinder specimens to verify the areas were in accordance with ASTM C39/C39M.

The inspectors observed the technician prepare the bearing blocks, spacers, specimens, and test machine prior to running each test to verify the tests were set up correctly in accordance with ASTM C39/C39M. The inspectors observed the test machine setup, including installation of the bearing blocks, spacers, and specimens to verify the machine was prepared and set up in accordance with ASTM C39/C39M. The inspectors independently checked and observed the technician confirm the axial alignment of the cylinders before and during axial loading to verify the load was applied in the manner required by ASTM C39/C39M.

The inspectors observed the application of the compressive axial load to the cylinder specimens to verify the tests were performed in accordance with ASTM C39/C39M and specification SV3-CC01-Z0-027, Section 6.1.12. The inspectors observed load testing to verify the load was applied in the method specified in ASTM C39/C39M. The inspectors observed and independently assessed the fracture pattern type of each cylinder after removal from the test machine to verify the technician identified and documented them on the test reports in accordance with ASTM C39/C39M.

The inspectors reviewed the certification record for the technician performing the tests to verify the technician was qualified in accordance with ASTM C39/C39M.

The inspectors reviewed the three test reports and two associated concrete batch tickets for the concrete cylinder strength testing to verify the records were complete, accurate, and contained the required information in accordance with ASTM C39/C39M, and specification SV3-CC01-Z0-027, Section 6.1.12. Additionally, the inspectors reviewed the test results to verify they met the strength requirements for the specified concrete mix in accordance with specification SV3-CC01-Z0-026, Section 4.2.10, "Concrete Mix Design."

29

b. Findings No findings were identified.

1A23 (Unit 3) ITAAC Number 3.3.00.02a.i.d (763) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.d (763). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A.02.01 - Observation of in-Process Installation Activities 65001.A.02.04 - Review As-built Deviations/Nonconformance The inspectors performed inspection of construction activities associated with column line 1 wall from J-2 to N from elevation 117'-6" to 127'-0" in the auxiliary building. The inspectors observed ongoing reinforcement installation, observed ongoing concrete placement activities, and reviewed licensee records including design drawings, specifications, E&DCRs, and N&Ds.

The inspectors performed independent measurements of installed reinforcement and embed plates. Specifically, the inspectors measured installed reinforcing steel to verify it met size and spacing requirements; met minimum concrete clear cover; and lap splices met the minimum length in accordance with ACI 349-01. Also, the inspectors measured reinforcement around mechanical penetrations to verify the configuration was in accordance with the latest approved design drawings. The inspectors independently measured reinforcement spacing in congested areas to verify whether reduced spacing between steel reinforcement met the requirements specified in Section 3.3.2 of ACI 349-

01. The inspectors also performed measurements of embedments to verify they were located properly in the structure, secured, and free of concrete or excessive rust and had the proper clearances in accordance with drawing SV3-0000-C9-002A.

The inspectors observed reinforcement installation activities to verify they were performed using the current approved design changes, design drawings, and design specifications in accordance with NQA-1 1994, Basic Requirement 3. The inspectors also reviewed three non-conformance reports and four disposition reports to verify nonconforming items were dispositioned in accordance with section 4.6.4 of procedure APP-GW-GAP-428.

The inspectors reviewed quality records and observed concrete placement activities.

Specifically, the inspectors reviewed concrete pour card No. 4199 to determine whether concrete mix design requirements were translated into quality assurance documents in accordance with design specification SV3-CC01-Z0-026. During concrete placement, the inspectors compared the pour card to the batch tickets to verify concrete delivered to the site had the appropriate concrete mix type. In addition, the inspectors evaluated whether transport time was completed within the time allowed by ACI 349-01 and the delivery was intended for the location in accordance with the pour card. The inspectors

30 observed concrete placement activities to determine whether placement drop distances met requirements specified in Section 4.2.4 of specification SV3-CC01-Z0-031. The inspectors also observed the use of concrete vibrators to verify they were handled and operated to aid adequate consolidation of the mix, including vertical operation and penetration into the previous placed concrete layer, in accordance with Section 4.2.9 of specification SV3-CC01-Z0-031.

During concrete placement, the inspectors observed in-process concrete testing to determine if concrete temperature, slump, and air content were determined at the mix delivery location as required by specification SV3-CC01-Z0-026 and ACI 349-01. The inspectors also observed the in-process testing to verify the methods used for testing were in accordance with specification SV3-CC01-Z0-027 and required ASTM standards for verifying applicable concrete properties. The inspectors observed the sampling of 24 concrete strength test cylinders to verify whether sample collection was performed in accordance with specification SV3-CC01-Z0-027 and ASTM C172.

b. Findings No findings were identified.

1A24 (Unit 3) ITAAC Number 3.3.00.02a.i.d (763) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.d (763). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A.02.01 - Observation of in-Process Installation Activities The inspectors performed inspection of construction activities associated with the floor from column line I to J-2 and 4 to intersecting vertical wall before column line 5 (column line 4.8) at elevation 107'-2" in the radiologically controlled area of the auxiliary building.

The inspectors observed ongoing reinforcement installation activities, reviewed licensee records including design drawings, design specifications, and E&DCRs.

The inspectors performed independent measurements of the floor reinforcement to verify it was installed in accordance with ACI 349-01. Specifically, the inspectors performed independent measurements of installed reinforcing steel to verify it was met size and spacing requirements; had minimum concrete clear cover; lap splices met the minimum length; and reinforcement around mechanical penetrations was installed in accordance with the design drawings. The inspectors also observed reinforcement installation activities to verify they were performed using the latest-approved design changes, design drawings and design specifications in accordance with NQA-1 1994, Basic Requirement 3.

31 The inspectors sampled seven E&DCRs to verify design changes were processed and translated into design drawings in accordance with procedure APP-GW-GAP-420.

b. Findings No findings were identified.

1A25 (Unit 3) ITAAC Number 3.3.00.02a.i.d (763) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.d (763). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A.02.01 - Observation of in-Process Installation Activities The inspectors performed inspection of construction activities associated with wall 4 located between column lines I and J-1 from elevation 117'-6" to 135'-3" in the radiation area of the auxiliary building. The inspectors observed ongoing reinforcement installation, performed independent measurements, and reviewed licensee records including design drawings, specifications, E&DCRs, and non-conformance reports.

The inspectors performed independent measurements of installed reinforcement and embed plates. Specifically, the inspectors measured installed reinforcing steel to verify it met size and spacing requirements; met minimum concrete clear cover; and lap splices met the minimum length in accordance with ACI 349-01. Also, the inspectors measured reinforcement around mechanical penetrations to verify the configuration was in accordance with the latest approved design drawings. The inspectors independently measured reinforcement spacing in congested areas to verify whether reduced spacing between steel reinforcement met the requirements specified in Section 3.3.2 of ACI 349-

01.

The inspectors also performed measurements of embedments to verify they were located in the structure in accordance with design drawings. The inspectors performed walkdowns to verify the embedments were secured, free of concrete or excessive rust, and had the appropriate clearances in accordance with General Notes drawing SV3-0000-C9-002A. The inspectors observed reinforcement installation activities to verify they were performed using the latest-approved design changes, design drawings, and design specifications in accordance with NQA-1 1994, Basic Requirements 3 and 5.

The inspectors reviewed two nonconformance reports and one E&DCR in order to verify whether design deviations were dispositioned in accordance with NQA-1-1994, Basic Requirement 3, and Supplement 3S-1.

32

b. Findings No findings were identified.

1A26 (Unit 3) ITAAC Number 3.3.00.14 (820) / Family 17E

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.14 (820). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.17-02.07 - Bullet Resisting Physical Barriers This input is security related. See non-public report 05200025/2018412 for details.

b. Findings No findings were identified.

1A27 (Unit 4) ITAAC Number 2.1.02.02a (13) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.02.02a (13). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.06 - Nondestructive Examination The inspectors observed in-process field activities and performed an independent assessment of the PT examinations on the weld preparation machined surface of the cold leg (L002A) to the reactor vessel inlet nozzle. The inspectors observed in-process field activities and performed an independent assessment of the PT examinations on the other Unit 4 RCS cold leg (L002B) to the east steam generator, for field weld SV4-RCS-PL01-FW-BCL05. The inspectors observed the examinations performed in the field by PCI inspectors to determine if the requirements of procedure GQP 9.7 were adhered to, including surface temperature of the weld, type of penetrant, solvent and developer used, and penetrant dwell time. The inspectors reviewed NDE PT procedure GQP 9.7, to determine if the procedure met the ASME Code,Section V, Article 6, and the acceptance criteria met the ASME Code,Section III, Subsection NB-5350. The inspectors also performed an independent assessment of the test results to determine if the requirements of the ASME Code,Section III, Subsection NB-5350 were met.

33

b. Findings No findings were identified.

1A28 (Unit 4) ITAAC Number 2.1.02.02a (13) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.02.02a (13). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.06-02.01 - General Installation The inspectors observed rigging and installation activities associated with steam generator (SG) MB-02 to verify the pre-installation and pre-lift safety verification, pre-transportation verification, rigging equipment size and load capacity selection, load lift calculations, and safety walkdown were performed in accordance with the rigging plan SV4-MB01-MHH-003.

The inspectors reviewed the design specification to verify if the design specification was in accordance with the ASME Code,Section III, Section NCA. The inspectors reviewed the technical manual to verify the rigging and hoisting of the steam generator into containment was completed without exceeding the design loads. Specifically, the inspectors reviewed the technical manual to verify if the center of gravity and lifting configuration were in accordance with the design specification.

The inspectors reviewed the rigging plan to verify lifting requirements were in accordance with the technical manual. Specifically, the inspectors reviewed the rigging plan to verify the load capacity calculations, pre-requisites, and sequential work steps laid out in the "Step by Step Lift Narrative" prior to lifting the SG were performed in accordance with the requirements of the technical manual. The inspectors observed the configuration of trunnion lift links A and B and the installation of the keeper plates to verify they were installed in accordance with the technical manual.

The inspectors reviewed the installation requirements, including proper location, placement, dimensions, alignment, and other mounting requirements to verify they were specified in the approved quality assurance traveler in accordance with the rigging plan.

The inspectors attended the pre-job briefing and performed a walkdown of the installation area to verify specially trained personnel and special tools were available to perform the work in accordance with the rigging plan. The inspectors reviewed the work steps and signature logs included in the work package to verify hold points were observed and quality control inspections were conducted as required by the rigging plan.

The inspectors observed the licensee's verification of the wind velocity and ambient temperature to verify the speed did not exceed 20 miles per hour at the boom tip and the ambient temperature was above 25 degrees Fahrenheit in accordance with the rigging plan. The inspectors observed the installation of the upending assembly to verify the assembly was installed in accordance with the installation drawing in the rigging plan.

34 Further, the inspectors observed the lift of the SG through the steam generator temporary installation system (SGTIS) to verify the nozzles did not get damaged in accordance with the rigging plan. The inspectors observed the final setting of the steam generator on the SGTIS and bolting trunnion lift links A & B to the SGTIS to verify it was supported for final installation and alignment in accordance with the rigging plan.

The inspectors reviewed two E&DCRs and one N&D to verify the disposition was conducted in accordance with specification APP-GW-GAP-428, "Nonconformance and Disposition Report," Revision 15.

b. Findings No findings were identified.

1A29 (Unit 4) ITAAC Number 2.1.02.02a (13) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.02.02a (13). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.03 - Installation and Welding 65001.03-02.06 - Nondestructive Examination 65001.B-02.02 - Welding Procedure Qualification 65001.B-02.03 - Welder Qualification 65001.B-02.04 - Production Controls The inspectors observed installation activities related to machine welding of the RCS hot and cold leg piping to the reactor vessel nozzles. Specifically, the inspectors observed GTAW machine welding for the following field welds to verify if the reactor coolant system loop installation was performed in accordance with the requirements of the ASME Code,Section III, Subsection NB:

SV4-RCS-PL01-FW-BHL01, that connect the hot leg L001B to the reactor vessel nozzle, SV4-RCS-PL01-FW-BCL04, that connect the cold leg L002C to the reactor vessel nozzle, and SV4-RCS-PL01-FW-BCL06, that connect the cold leg L002D to the reactor vessel nozzle.

The inspectors reviewed the steps of the work package, including hold point sign-offs by the welders, QC personnel, NDE Level II, and the ANI to verify if the sequence was maintained and the steps were performed in accordance with the ASME Code,Section III, Subsection NB. The inspectors observed in-process GTAW machine welding of the root welds and intermediate weld passes to verify whether the inter-pass temperature, electrical characteristics, techniques, and argon shielding gas requirements were maintained and checked by the welding operator in accordance with the approved WPS.

35 The inspectors observed in-process welding parameters to verify if the voltage, amperage, travel speed, and wire-feed speed were being controlled in accordance with the WPS qualified to the requirements of the ASME Code,Section IX. The inspectors reviewed the following activities to verify they were performed in accordance with the WPS and work package:

the work, including details of materials and personnel, was documented; the weld joint was sufficiently protected from wind or rain; the weld area was clean and free of harmful substances such as moisture, grease, or paint; cleaning and grinding between weld passes and starts and stops were performed as necessary; the correct weld filler metal was used and had been appropriately issued with a weld material requisition slip; QC personnel performed regular inspections of the welding activities; the interpass temperature was monitored and kept below the procedure's maximum temperature; and the welds were made in accordance with the variables listed in the WPS.

The inspectors reviewed WPS 8MN-GTAW to verify whether applicable essential variables met the requirements of the ASME Code,Section IX and were qualified to meet the ASME Code,Section III. The inspectors reviewed a sample of four welding operator's qualification records to verify if the skill of welding operators were tested, certified, and maintained in accordance with the requirements of the ASME Code,Section IX. Additionally the inspectors reviewed the CMTR for the weld filler metal used to verify if the weld material physical and chemical composition were in accordance with the ASME Code, Sections II, Part C, and were qualified in accordance with the requirements of the ASME Code,Section III.

The inspectors observed in-process field activities of the NDE PT for the following weld surfaces to verify whether the NDE examinations were performed and documented in accordance with the qualified PT procedure:

internal back weld surface of field weld SV4-RCS-PL01-FW-BCL06 between the cold leg RCS-L002D and reactor vessel inlet nozzle, tack block removal on external surfaces of hot and cold legs, and welding preparation of field weld SV4-RCS-PL01-FW-BCL05 on cold leg RCS-L002B to steam generator MB-02.

The inspectors reviewed NDE RT and PT procedures to verify the examination techniques were in accordance with the requirements of the ASME Code,Section V, Articles 2 and 6, and the acceptance criteria met the requirements of the ASME Code,Section III, Subsection NB-5350, "Examination." The inspectors reviewed the written practice for qualification and certification of NDE personnel to verify the document was in accordance with ASNT Recommended Practice SNT-TC-1A-1992, "Personnel Qualification and Certification in Nondestructive Testing." The inspectors observed the PT examination performed in the field by a Level II inspector to verify the requirements of General Quality Procedure 9.7, "Solvent Removable Liquid Penetrant Examination and Acceptance Standard for Welds, Base Materials and Cladding (40 to 125F)," were

36 adhered to, including checking the surface temperature of the weld, type of penetrant, solvent and developer used, and penetrant and developer dwell times.

The inspectors reviewed the RT performed on hot leg RCS-L001B, cold leg RCS-L002C and RCS-L002D to verify whether the test results recorded by Level II inspectors met the requirements of the ASME Code,Section III, Subsection NB-5350. The inspectors also reviewed the PT performed on welding preparation of field weld RCS-PL01-FW-BCL03 to verify if the test results recorded by Level II inspectors met the requirements of the ASME Code,Section III, Subsection NB-5350.

The inspectors reviewed material certificate of conformance reports for cleaner, penetrant, and developer to verify if the sulfur and halogen material content were less than 1% by weight in accordance with the requirements of the ASME Code,Section V, Article 6, Paragraph T-640, and Article 24. The inspectors reviewed the qualification and certification records for both Level II PT and RT inspectors to verify if the qualifications were in accordance with the ASME Code Section III, Subarticle NB-5520, "Personnel Qualification, Certification, and Verification." Finally, the inspectors reviewed calibration records of the measuring and test equipment used for NDE inspection to verify whether the equipment was controlled, traceable, and calibrated in accordance with the requirements of 10 CFR Part 50 Appendix B, Criteria XII and ASME NQA-1-1994.

b. Findings No findings were identified.

1A30 (Unit 4) ITAAC Number 2.1.03.03 (72) / Family 05F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.1.03.03 (72). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.05-02.03 - RPV Installation The inspectors reviewed the reactor pressure vessel (RPV) design specification to verify if the two temporary lifting lugs were used for rigging and hoisting into the containment vessel to prevent exceeding the design loads in accordance with the requirements of the ASME Code Section III, Subsections NCA and NB, and NQA-1-1994, Part II, Subpart 2.15.

The inspectors reviewed the RPV technical manual to determine if the dry weight, center of gravity location, handling requirements for the upending sequence and vertical lift position were in accordance with the design specification.

The inspectors reviewed the rigging plan to determine if the capacity of the crane, use of the RPV upending J-skid, steel cable spreader bar, torqued lifting lugs with pin lubrication for upending, and weather conditions were in accordance with the technical manual. Finally, the inspectors reviewed the rigging plan to verify if load testing was

37 performed prior to lifting the RPV in accordance with the "Step by Step Lift Narrative" that included prerequisite and sequential work step signatures.

b. Findings No findings were identified.

1A31 (Unit 4) ITAAC Number 2.2.01.01 (90) / Family 11A

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.01.01 (90). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.A.02.03 - Independent Assessment/Measurement Inspection The inspectors performed a containment system (CNS) functional arrangement walkdown for the following containment vessel flued head nozzle penetrations:

SV4-RNS-PY-C01 (P19, RCS to RHR pump outlet);

SV4-RNS-PY-C02 (P20, RHR pump to RCS inlet); and SV4-SFS-PY-C02 (P22, IRWST reference cavity purification outlet).

Specifically, the inspectors independently measured the as-built azimuth and elevation locations of the penetrations to verify compliance with the UFSAR, Section 2.2.1, and Figure 2.2.1-1 of Appendix C of the COL for the CNS, such that these penetration samples are located in accordance with the construction isometric drawings. The inspectors reviewed the construction drawings to verify if they met the CNS component locations as shown in Figure 2.2.1-1 of Appendix C of the COL. Finally, the inspectors observed the penetration coverings to verify that they were adequately protected against damage from adjacent work.

b. Findings No findings were identified.

1A32 (Unit 4) ITAAC Number 2.2.01.02a (91) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.01.02a (91). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.11-02.03 - Installation and Welding 65001.B-02.03 - Welder Qualification

38 65001.B-02.05 - Inspection The inspectors observed GTAW activities and reviewed documentation for joining two containment vessel penetration assemblies for field welds SV4-SFS-PY-C02 (P22, IRWST reference cavity purification outlet) and SV4-RNS-PY-C01 (P19, RCS to RHR pump outlet) to verify welding and inspections were performed in accordance with the requirements of the ASME Code,Section III, Subsections NE and NC, respectively.

Specifically, for pressure boundary field weld SV4-SFS-PY-C02-2 (P22, flued head to penetration sleeve), the inspectors observed the fit-up and tack welds to verify the alignment and root opening were in compliance with the ASME Code,Section III, Subsection NE-4230. The inspectors reviewed the CMTR for the rod heat number 1332L to verify the chemical analysis and mechanical properties were in accordance with the requirements of the ASME Code,Section II. The inspectors also reviewed the weld material requisition record to verify weld material traceability was maintained in compliance with the ASME Code,Section III, Subsection NE. The inspectors measured the final cover pass maximum reinforcement thickness to verify compliance with the ASME Code,Section III, Subsection NE-4426. The inspectors reviewed the welder qualification record for welder AT2517 to determine if the welder was tested and certified in accordance with the requirements of the ASME Code,Section IX.

For pressure boundary field weld SV4-RNS-PY-C01-3 (P19, flued head to guard pipe),

the inspectors observed fit-up and tack inspection activities performed by the QC inspector to verify the individual performed the inspection in compliance with the qualified welding procedure. The inspectors reviewed the weld material requisition record to verify the weld filler material traceability was maintained in accordance with the licensee's site welding procedures.

Finally, the inspectors reviewed final NDE reports for PT and RT on field weld SV4-SFS-PY-C02-2 (P22) and RT on field weld SV4-RNS-PY-C01-3 (P19) to verify the required examinations were accepted in accordance with the ASME Code,Section III, Subsections NE-5350 and NC-5320, respectively.

b. Findings No findings were identified.

1A33 (Unit 4) ITAAC Number 2.2.02.02a (120) / Family 07F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.02.02a (120). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.01 - Purchase and Receipt of Materials 65001.03-02.02 - Storage and Handling 65001.03-02.03 - Installation and Welding

39 65001.03-02.05 - Pressure Testing 65001.03-02.06 - Nondestructive Examination 65001.03-02.07 - Review of Records 65001.03-02.08 - Problem Identification and Resolution 65001.07-02.01 - General Installation 65001.07-02.02 - Component Welding 65001.07-02.05 - Problem Identification and Resolution 65001.B-02.02 - Welding Procedure Qualification 65001.B-02.03 - Welder Qualification 65001.B-02.06 - Records 65001.F-02.02 - Fabrication Records Review The inspectors conducted an inspection of Module KB-36, which consists of ASME pipe spools and valves in the PCS. The inspectors performed this inspection to verify KB-36 was fabricated in accordance with ASME Code,Section III, WEC design and fabrication specifications, and the UFSAR, Chapter 6. Specifically, the inspectors reviewed fabrication and installation records applicable to the following valves and their associated pipe spools and pipelines:

PCS-V020 (3 inch manual operated gate valve) installed in pipe spool SV4-PCS-PLW-10F-1A/1B, part of line PCS-PL-L007 (Post-72-hour containment cooling makeup from supply line connections);

PCS-V044 (4 inch manual operated gate valve) installed in pipe spool SV4-PCS-PLW-10X-1A/1B, part of lines PCS-PL-L048 & L051 (post-72-hour supply line connection); and PCS-V050 (2 inch manual operated globe valve) installed in pipe spool SV4-PCS-PLW-10E-1A, part of line PCS-PL-L049 (post-72-hour SFS makeup from supply line connection.)

The inspectors reviewed fabrication records for the valves and pipe spools listed above, including associated pressure boundary welds, to verify the installation was accomplished by qualified personnel and in accordance with approved drawings, qualified procedures, fabrication specifications, and applicable codes and standards.

The inspectors reviewed purchase orders and fabrication specifications to verify quality, technical, material, and regulatory requirements were adequately specified in accordance with 10 CFR Part 21 and Part 50, Appendix B, the ASME Code, the UFSAR, and design specifications.

The inspectors reviewed ASME N-5, NPP-1, and NPV-1 code data reports from the fabricators to determine whether the materials specified and hydrostatic tests performed met the requirements of the ASME code and the design specification. In addition, the inspectors reviewed the data reports to determine if they were signed by an authorized representative of the N-stamp holder and an ANI. The inspectors also reviewed the results for the hydrostatic shell test, valve closure and seat leakage test, backseat leakage test, packing leakage test, and operational test recorded in the production test report to verify the required minimum test pressures, holding times, leak rates, and number of times cycled met the requirements listed in the design specification for the valve tested.

40 The inspectors reviewed the applicable code data reports, weld travelers, and vendor and WEC drawings to verify if the records provided adequate traceability to identify the associated components to the welding procedures, welders, NDE reports, and nonconformance reports used during fabrication. Additionally, the inspectors reviewed all the applicable documents to verify valve and piping materials and welding consumables were of the correct specified type and grade and were uniquely identified by a heat number and markings on the material, when appropriate.

The inspectors reviewed CMTRs to verify if materials were properly heat treated and met the specified chemical, mechanical, and NDE requirements of the ASME Code, Sections II and III, the UFSAR, and WEC design documents. The inspectors also reviewed CMTRs to verify no base material repairs were made without approval from the purchaser in accordance with the ASME Code and WEC fabrication specifications.

The inspectors reviewed a sample of welding procedures to verify the processes and essential variables used were qualified as required by the ASME Code, Sections III and IX. Specifically, the inspectors reviewed the welding procedures to verify if they were written in accordance with a supporting PQR and the ASME Code,Section IX. In addition, the inspectors reviewed the supporting PQRs to verify the ranges of welding variables were qualified and the qualification tests (both type and number of tests) met the acceptance criteria required by the ASME Code.

The inspectors reviewed a sample of welder performance qualification records to determine if the welders were assigned a unique identification number and demonstrated their skill by performing specific performance qualification tests, the qualification testing conditions and qualification limits were fully documented, and the required number of acceptable test results were achieved in accordance with the ASME Code,Section IX, 2007 Edition 2008 Addenda.

The inspectors reviewed reports from VT and PT examinations to determine if the welds had been inspected as required by the ASME Code,Section V and found to meet the acceptance criteria of the ASME Code,Section III.

Lastly, the inspectors walked down the module to verify the selected welds did not have any surface defects; the valves were oriented adequately to match their designed flow direction; the material markings were appropriate; and the module was stored in accordance with the design specifications and applicable ASME Code sections.

b. Findings No findings were identified.

41 1A34 (Unit 4) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.06 - Nondestructive Examination The inspectors reviewed computed radiography of three stainless steel pipe field welds.

The welds were for the isolation valves to common injection header piping line PXS-L018B and the CMT A discharge piping lines PXS-L016A and PXS-L017A. Specifically, the inspectors reviewed the results and examination reports for the following welds to determine compliance with the requirements of the ASME Code, Section III:

Report V-18-RT-302-0267 for field weld SV4-PXS-PLW-020-3 for 8" pipe to inlet side of check valve PXS-PL-V016B on line PXS-L018B; Report V-18-RT-302-0281 for field weld SV4-PXS-PLW-01V-8 for 8" pipe to inlet side of globe valve PXS-PL-V015A on line PXS-L017A; and Report V-18-RT-302-0330 for field weld SV4-PXS-PLW-01V-10 for 8" pipe to inlet side of globe valve PXS-PL-V014A on line PXS-L016A.

The inspectors reviewed images of the welds to determine whether the technique and brightness at the body of the required wire image quality indicator locations in the area of interest were in accordance with the requirements of MISTRAS radiography procedure 521-RT-302 and the ASME Code,Section V, Article 2. Additionally, the inspectors reviewed the images to determine if the results were in accordance with the requirements of the ASME Code,Section III, Subsection NB-5320, Radiographic Acceptance Standards. Finally, the inspectors reviewed the radiography reports listed above to determine if the results for acceptance were accurately recorded in accordance with MISTRAS 521-RT-302 procedure.

b. Findings No findings were identified.

1A35 (Unit 4) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.06 - Nondestructive Examination 65001.03-02.07 - Review of Records

42 65001.B-02.05 - Inspection The inspectors observed installation activities associated with CMT A discharge check valve PXS-PL-V017A to DVI line PXS-PL-L018A at elevation 97'-0. The inspectors observed manual stainless steel GTAW activities for field weld SV4-PXS-PLW-01K-1 to verify the valve installation was controlled in accordance with the requirements of the ASME Code,Section III, Subsection NB.

The inspectors reviewed the steps of the work package for hold point sign-offs by the welder, QC personnel, and the ANI to verify the sequence was maintained and the steps were performed in accordance with the ASME Code,Section III, Subsection NB. The inspectors reviewed WPS 1-8.8T01 to verify the essential variables met the requirements of the ASME Code,Section IX. The inspectors also reviewed the weld data sheet included in the work package to verify the WPS, the joint details, the traceability of the welder and weld filler material, the welding instructions and notes, the inspection and NDE procedures, the QC and ANI hold points, and the M&TE traceability were in accordance with the site welding procedures.

The inspectors observed intermediate welding passes to ensure the welder was observing the requirements for interpass temperature, electrical characteristics, and argon shielding gas in accordance with the approved WPS. The inspectors reviewed the welder's performance qualification record to verify the welder was qualified for the process and position in accordance with the requirements of the ASME Code,Section IX, Article III, QW-304. The inspectors reviewed the weld filler metal material CMTRs to verify the material properties conform to the requirements of the ASME Code,Section II, Part C and were in accordance with the requirements of the ASME Code,Section III.

In addition, the inspectors reviewed the NDE results of PT and RT for field weld SV4-PXS-PLW-01K-1 to verify the records included the essential variables and the acceptance criteria were documented in accordance with the qualified NDE procedure.

The inspectors reviewed the NDE reports to verify the results were reviewed and accepted by a Level II inspector. The inspectors reviewed the PT and RT procedures to verify the examination techniques and acceptance criteria were in accordance with the requirements of the ASME Code,Section III, Article NB-5000, "Examination."

The inspectors reviewed the written practice for qualification and certification of NDE personnel to verify the document was in accordance with ASNT Recommended Practice SNT-TC-1A-1992, "Personnel Qualification and Certification in Nondestructive Testing."

The inspectors reviewed the qualification and certification records of both Level II PT and RT inspectors to verify the qualifications were in accordance with the ASME Code,Section III, Subarticle NB-5520, "Personnel Qualification, Certification, and Verification."

The inspectors reviewed the certification records of the NDE consumables to verify the sulfur and halogen contents were less than 1% by weight per the requirements of the ASME Code,Section V, Article 6, Paragraph T-640, and Article 24. Finally, the inspectors reviewed calibration records of the M&TE used for NDE inspection to verify the equipment was controlled and calibrated in accordance with the requirements of 10 CFR 50, Appendix B, Criteria XII.

43

b. Findings No findings were identified.

1A36 (Unit 4) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.03-02.03 - Installation and Welding 65001.03-02.06 - Nondestructive Examination 65001.B-02.04 - Production Controls 65001.B-02.06 - Records The inspectors reviewed installation records associated with accumulator lines SV4-PXS-PL-L025A and L027A to discharge check valves SV4-PXS-PL-V029A and SV4-PXS-PL-V028A, respectively. Specifically, the inspectors reviewed the weld records for field welds SV4-PXS-PLW-014-6 (check valve SV4-PXS-PL-V029A to DVI line SV4-PXS-PL-L025A) and field weld SV4-PXS-PLW-014-10 (check valve SV4-PXS-PL-V028A to DVI line SV4-PXS-PL-L027A).

The inspectors reviewed the records of manual GTAW welding activities performed on the field welds to verify the valve installations were performed in accordance with the requirements of the ASME Code,Section III, Subsection NB. The inspectors reviewed the steps of the work package, including hold point sign-offs by the welder, QC personnel, and the ANI, to verify the sequence was maintained. The inspectors reviewed WPS 1-8.8T01 to verify the interpass temperature, electrical characteristics, techniques, and shielding gas were specified in accordance with the requirements of the ASME Code,Section IX.

The inspectors reviewed the performance qualification record for three welders to verify the welders were qualified for the process and position in accordance with the requirements of the ASME Code,Section IX, Article III, QW-304. The inspectors reviewed the weld filler metal CMTRs to verify the material properties conformed to the requirements of the ASME Code,Section II, Part C and were qualified in accordance with the requirements of the ASME Code,Section III.

In addition, the inspectors reviewed the NDE results of PT to verify the tests satisfied the acceptance criteria and were reviewed and accepted by a Level II inspector in accordance with the PT procedure. The inspectors reviewed the PT procedure to verify the examination techniques and acceptance criteria were in accordance with the requirements of the ASME Code,Section III, Article NB-5000, "Examination." The inspectors reviewed the written practice for qualification and certification of NDE personnel to verify the document was in accordance with ASNT Recommended Practice SNT-TC-1A-1992, "Personnel Qualification and Certification in Nondestructive Testing."

44 The inspectors reviewed the qualification and certification records of two Level II PT inspectors to verify they met the ASME Code,Section III, Subarticle NB-5520, "Personnel Qualification, Certification, and Verification."

b. Findings No findings were identified.

1A37 (Unit 4) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.06-02.01 - General Installation 65001.A.02.01 - Observation of in-Process Installation Activities 65001.A.02.03 - Independent Assessment/Measurement Inspection The inspectors observed the heavy lift and placement of accumulator B (tank PXS-MT-01B) into containment to verify the component lift was performed in accordance with the ASME Code,Section III, Subsections NCA and NB. The inspectors reviewed the design specification to verify the lifting lugs met the ASME Code,Section III, Subsections NCA and NB. The inspectors reviewed the technical manual to verify the weight, center of gravity, and lift instructions were in accordance with the design specification. The inspectors observed the lift to verify the accumulator was oriented in accordance with the technical manual. The inspectors reviewed the rigging plan to verify the lift requirements were in accordance with the technical manual. Specifically, the inspectors observed the licensee's verification of the wind velocity, the ambient temperature, and the alignment of the tank and rigging during the lift.

Also, the inspectors reviewed the attachment points, attachment type, and the rigging material to verify the accumulator rigging configuration was in accordance with the rigging plan. The inspectors observed the lift to verify the accumulator was not damaged. The inspectors also observed the final set of the accumulator tank in the nuclear island, including alignment of the baseplate holes to the anchor bolts, release of the load from the crane, and initial installation of the nuts to the anchor bolts, to verify the tank was aligned and installed in the correct location in accordance with the design specification and the rigging plan.

In addition, the inspectors walked down the tank prior to installation to verify the tank matched the physical description in the COL Appendix C, Section 2.2.3, "Passive Core Cooling System." The inspectors reviewed the nameplate attached to the tank to verify it matched the description in the design description; met the marking requirements of ASME Code Section III for a Class 3 pressure vessel; and had the component number designated in COL Appendix C, Table 2.2.3-1. The inspectors observed the following attributes to verify they met the requirements of the technical manual:

45 surface of the tank and attachments, including no signs of physical damage or deterioration during storage; tank nozzles were adequately covered to preclude introduction of foreign materials during tank installation; and the uncoated portions of the tank, baseplates, and nozzles to verify there were no potentially harmful contaminants on those surfaces.

b. Findings No findings were identified.

1A38 (Unit 4) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.F-02.02 - Fabrication Records Review The inspectors reviewed procurement and fabrication records for Class 1500 8" diameter check valve SV4-PXS-PL-V017A welded to CMT direct injection line PXS-PL-L018A to verify the fabrication and testing met the requirements of WEC design specification APP-PV03-Z0-001 and the ASME Code,Section III, Subsection NB. The inspectors reviewed records related to the valve body, the valve disk, the pipe fittings, the 2" round bar for weld sleeve, and the concentric reducer.

The inspectors reviewed the WEC purchase order and vendor's certificate of compliance to verify the valve was hydrostatically tested in accordance with the WEC design specification.

The inspectors reviewed fabrication records including CMTRs for the valve parts and weld filler metals to verify the applicable chemical analysis, mechanical properties, and heat treatment were in accordance with requirements of the ASME Code,Section II, Parts A and C. The inspectors reviewed RT and PT reports for the valve to verify the NDE exam results met the acceptance criteria of the ASME Code,Section III.

The inspectors reviewed records for the pressure boundary weld between the reducer and the valve to verify welding was performed in accordance with the requirements of the ASME Code, Sections III. The inspectors reviewed the valve ASME Code Data NPV-1 report to verify the traceability of materials, dimensions, and hydrostatic test pressure and temperature were in accordance with the ASME Code. In addition, the inspectors reviewed the ASME Code data report to verify the ANI had inspected the valve and authorized the application of the Code symbol stamp in accordance with the ASME Code,Section III, Subsection NCA-8000. The inspectors reviewed the valve pneumatic seat test report and hydrostatic test report to verify the test parameters and results met the acceptance criteria of the WEC valve data sheet and WEC design

46 specification. The inspectors reviewed the final quality data package to verify the records were complete, accurate, reviewed and approved by the responsible organizations, and provided objective quality evidence the ASME Code requirements were satisfied.

The inspectors reviewed deviation reports issued during the design and fabrication of valve parts to verify deviations were dispositioned with technical justification and approved by the customer in accordance with site corrective action procedures.

b. Findings No findings were identified.

1A39 (Unit 4) ITAAC Number 2.2.03.02a (159) / Family 06F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 2.2.03.02a (159). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.04-02.01 - General Installation 65001.04-02.02 - Pipe Support and Restraint Welding 65001.B-02.02 - Welding Procedure Qualification 65001.B-02.03 - Welder Qualification 65001.B-02.04 - Production Controls 65001.B-02.05 - Inspection The inspectors reviewed isometric construction drawing APP-PXS-PLW-02L for PXS pipe support SV4-PXS-PH-11R0142 located in containment building room 11207 to verify the pipe support was installed in accordance with the qualified welding procedure.

The inspectors performed a walkdown of a rigid pipe support on line PXS-PL-127B to verify it was constructed and installed in the location and was aligned and supported the pipe in accordance with the isometric drawing. The inspectors observed SMAW for field weld SV4-PXS-PH-11R0142-7 to verify the welding location was in accordance with the weld map.

The inspectors observed intermediate pass welding to verify the interpass temperature, amperage and voltage, shielding gas, gas flow rate, technique, and travel speed to verify they were within the limits of the WPS. The inspectors reviewed the WPS to verify it was qualified in accordance with the requirements of the ASME Code,Section IX. The inspectors reviewed the work steps of the WDS to verify the hold point sign-offs were sequentially performed by QC personnel in accordance with the licensee's procedures.

The inspectors also reviewed the weld data sheet in the work package to verify the following attributes were in accordance with the site general welding specification:

assembly was properly documented, including details of materials and personnel activities;

47 weld joint was sufficiently protected from wind or rain; weld area was clean and free of harmful substances such as moisture, grease, or paint; cleaning and grinding between weld passes and starts and stops were performed as necessary; correct weld filler metal was being used and had been appropriately issued with a weld material requisition slip; QC performed regular inspections of the welding activities; interpass temperature was monitored and kept below the procedure's maximum temperature; and welds were made in accordance with the variables listed in the WPS.

The inspectors reviewed the welder's performance qualification record to verify the individual was qualified for the welding process and position in accordance with the requirements of the ASME Code,Section IX, Article III, QW-304. The inspectors reviewed weld material requisition slips from the rod room and etchings on the electrodes to verify the weld filler material was being properly controlled and traceable to the lot number in accordance with the quality assurance program. The inspectors reviewed the weld filler metal CMTRs to verify the material's chemical analysis and mechanical properties conformed to the requirements of the ASME Code,Section II, Part C, and Section III, Subsection NF.

In addition, the inspectors reviewed the NDE MT examination report to verify the surface examination was performed and accepted by a Level II inspector in accordance with the qualified NDE MT procedure and the ASME Code,Section III, Article NF-5000, "Examination." The inspectors reviewed the qualification and certification of NDE personnel to verify the document was in conformance with ASNT Recommended Practice No. SNT-TC-1A-1992, "Personnel Qualification and Certification in Nondestructive Testing". The inspectors reviewed the qualification and certification record of the Level II MT examiner to verify the qualifications were in accordance with ASNT SNT-TC-1A. The inspectors reviewed the certification records of the NDE consumables to verify the material met the requirements of the ASME Code,Section V, Article 7. Finally, the inspectors reviewed calibration records of the M&TE used for the NDE MT examination to verify the equipment was controlled and calibrated in accordance with the requirements of the M&TE program procedures.

b. Findings No findings were identified.

1A40 (Unit 4) ITAAC Number 3.3.00.02a.i.c (762) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.c (762). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement

48 65001.A.02.03 - Independent Assessment/Measurement Inspection 65001.A.02.04 - Review As-built Deviations/Nonconformance The inspectors performed on-site inspection of construction activities associated with the non-radiological area of the auxiliary building. The inspectors performed inspection activities associated with the wall segment located along column line P and between the shield building wall and column line 11, from elevation 100'-0" to 117'-6". The inspectors observed ongoing reinforcement installation activities and reviewed a sample of licensee records, including three design drawings, three N&D reports, and one E&DCR. The inspectors reviewed these documents to determine if differences between the as-built and as-designed structure was properly documented and incorporated in the final as-built drawings.

The inspectors performed independent measurements of steel reinforcement bars in the wall to verify they were constructed in accordance with ACI 349-01. Specifically, the inspectors conducted in-field measurements of installed main horizontal and vertical reinforcing steel to verify it met the size and spacing requirements; the minimum concrete clear cover; and the lapped splices met the minimum length as described in design drawings.

b. Findings No findings were identified.

1A41 (Unit 4) ITAAC Number 3.3.00.02a.i.c (762) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.c (762). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A.02.01 - Observation of in-Process Installation Activities 65001.A.02.03 - Independent Assessment/Measurement Inspection 65001.A.02.04 - Review As-built Deviations/Nonconformance The inspectors reviewed design drawings; took independent measurements; and observed ongoing work associated with construction of the reinforced concrete column line 11 wall from column line L to P from elevation 100'-0" to 117'-6" in the auxiliary building.

The inspectors reviewed design drawings to verify they were in accordance with the UFSAR and COL, Appendix C, Section 3.3. Specifically, the inspectors reviewed the reinforcement details, including splices, development length, and shear reinforcement, as described in the drawings to verify it met the seismic category 1 structural design and analysis requirements specified in ACI 318/349. The inspectors reviewed coupler and weld sizing requirements described in the drawings to verify they met the requirements

49 of the UFSAR, Section 3.8.4.5.1. The inspectors reviewed the dimensions detailed in the drawings to verify they aligned with the seismic analysis inputs specified in the UFSAR, Section 3.8.4.5.3 and COL, Appendix C, Section 3.3. The inspectors reviewed the concrete design requirements, including strength and aggregate size, described in the drawings to verify the requirements of the UFSAR, Section 3.8.4.6.1.1 were included. The inspectors reviewed the reinforcing steel material requirements, including mechanical connection material requirements, as described in the drawings to verify they encompassed the requirements specified in the UFSAR, Section 3.8.4.6.1.2. The inspectors reviewed the reinforcing steel sizes and spacing specified in the design drawings to verify it aligned with the UFSAR, Figure 3H.5-5.

The inspectors independently measured the steel reinforcement sizes, spacing, and locations of the vertical and horizontal rebar to verify it was installed in accordance with the design drawings, specifications SV4-CC01-Z0-031 and SV4-CR01-Z0-011, and ACI 349-01, Chapter 21, "Special Provision for Seismic Design." The inspectors measured the reinforcing bar dowels and lap splices to verify they met the requirements specified on the design drawings, in specification SV4-CR01-Z0-011, ACI 349-01, Chapter 21, and ACI 349-01, Chapter 12, "Development and Splices of Reinforcement." The inspectors measured the hooks and bar bends to verify they met development, splice, and bend diameter requirements of ACI 349-01, Chapter 12 and Chapter 21. The inspectors independently measured the reinforcement bar clearances to verify they were installed in accordance with ACI 349-01, Section 3.3.2. The inspectors observed the markings on the steel reinforcement bars to verify they were the size specified on the design drawings and were the material required by ACI 349-01, Section 21.2.5, Reinforcement in Members Resisting Earthquake-Induced Forces.

The inspectors observed in-process installation activities to verify work packages were available in the work area and were followed in accordance with NQA-1-1994, Basic Requirement 5 and 10 CFR 50, Appendix B. The inspectors reviewed the signature logs in the work packages to verify the installation and inspection sequences were maintained in accordance with 10 CFR 50, Appendix B, Criterion V and 1-SV4-CC01-Z-031, Section 4.5, "Inspection/Verification."

The inspectors observed in-process installation activities of embedded plates to verify these activities were controlled and performed in accordance with specification SV4-CC01-Z-031, Section 4.2.3.6. Additionally, the inspectors independently measured the embedded plates specified on design drawings APP-12S02-CE-PW903 and APP-12S02-CE-PW904 to verify they were properly located along column line 11 and were secured providing proper clearances as required by the design drawings. The inspectors observed the surface of these embedded plates to confirm excessive rust or material defects were not present.

The inspectors reviewed a sample of four design changes to ensure differences between the as-built and as-designed structures were documented and dispositioned in accordance with NQA-1-1994, Basic Requirement 3 and specification APP-GW-GAP-420. Additionally, the inspectors reviewed the technical justifications for these design changes to verify the dispositions had suitable technical bases in accordance with ACI-349-01 and 10 CFR 50, Appendix B.

50

b. Findings No findings were identified.

1A42 (Unit 4) ITAAC Number 3.3.00.02a.i.c (762) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.c (762). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A.02.04 - Review As-built Deviations/Nonconformance The inspectors performed inspection activities associated with walls on column lines L and M located between wall 11 and the shield building from elevation 100'-0" to 117'-6".

The inspectors observed ongoing reinforcement installation activities and reviewed licensee records including design drawings, design specifications, design change documents, and nonconformance reports.

The inspectors performed independent measurements of steel reinforcement on walls L and M to verify whether they were installed in accordance with the requirements of ACI 349-01. Specifically, the inspectors conducted in-field measurements of installed reinforcing steel to verify it met the size and spacing requirements; minimum concrete clear cover; lapped splices met the minimum length; and reinforcement around wall penetrations was installed in accordance with latest approved design drawings.

The inspectors independently measured reinforcement spacing in congested areas to verify whether reduced spacing between steel reinforcement met the requirements specified in Section 3.3.2 of ACI 349-01. The inspectors performed measurements of embedments to verify they were located, secured, free of concrete or excessive rust, and had the clearances in accordance with General Notes drawing SV3-0000-C9-002A.

The inspectors evaluated the condition of installed reinforcement to verify it was secured, free of concrete or excessive rust, and had the clearances in accordance with the licensee's design specification and drawings.

The inspectors observed reinforcement installation activities to verify they were performed using the latest-approved design changes, design drawings and design specifications in accordance with procedure APP-GW-GAP-420 and NQA-1 1994, Basic Requirement 3 and Supplement 3S-1. The inspectors also reviewed two nonconformance reports to verify if non-conforming items were dispositioned in accordance with Section 4.6.4 of procedure APP-GW-GAP-428.

b. Findings No findings were identified.

51 1A43 (Unit 4) ITAAC Number 3.3.00.02a.i.d (763) / Family 01F

a. Inspection Scope The inspectors performed a direct inspection of construction activities associated with ITAAC Number 3.3.00.02a.i.d (763). The inspectors used the following NRC IPs/sections to perform this inspection:

65001.02-02.01 - Inspection of Concrete Placement 65001.A.02.04 - Review As-built Deviations/Nonconformance The inspectors performed inspection of construction activities associated with column line N wall from column line 1 to 12'-9" north of column line 1 from elevation 100'-0" to 118'-2 1/2" in the Unit 4 radiologically controlled area of the auxiliary building. The inspectors observed ongoing reinforcement installation and concrete placement activities and reviewed the licensee's records including design specifications, design drawings, and E&DCRs.

The inspectors performed independent measurements of the wall reinforcement to verify it was constructed in accordance with ACI 349-01. Specifically, the inspectors measured installed reinforcing steel to verify whether it met the size and spacing requirements; met minimum concrete clear cover; and lap splices met the minimum length in accordance with the design drawings.

The inspectors sampled four E&DCR's to determine if steel reinforcement was installed using the latest-approved design changes, design drawings, and design specifications in accordance with NQA-1 1994, Basic Requirement 3 and Supplement 3S-1.

The inspectors reviewed quality records and performed direct inspection of concrete placement activities. Specifically, the inspectors reviewed concrete pour card No. 4029 and a sample of three batch tickets to determine whether concrete mix design requirements were properly translated into quality assurance documents in accordance with design specification SV4-CC01-Z0-026. The inspectors compared the pour card to the batch tickets to verify concrete delivered had the proper mix type and delivery location. In addition, the inspectors verified the concrete trucks did not exceed the 300 revolutions specified on SV4-CC01-Z0-026 prior to placement of the mix. The inspectors also verified transport time was completed within the time allowed by ACI 349-01.

During the concrete placement, the inspectors observed in-process concrete testing to determine whether concrete temperature, slump, and air content requirements in the mix were verified by quality control personnel as required by specification SV4-CC01-Z0-026 and ACI 349-01. The inspectors observed the in-process testing to verify the methods used for testing were in accordance with specification SV3-CC01-Z0-027 and required ASTM standards. The inspectors also observed the sampling of 24 concrete strength test cylinders to verify whether sample collection was performed in accordance with specification SV4-CC01-Z0-027 and ASTM C172.

52

b. Findings No findings were identified.

IMC 2504, Construction Inspection Program - Inspection of Construction and Operational Programs 1P01 Construction QA Criterion 16

a. Inspection Scope Follow-Up of Selected Issues Based on items reviewed during routine corrective action program reviews, the inspectors selected a sample of issues identified in the corrective action programs for a more in-depth review and follow-up.

The inspectors reviewed SNC corrective action report 211074, (NRC Identified)

Clarification to Westinghouse on Boron Precipitation Concern CR 815684, corresponding WEC corrective action prevention and learnings (CAPAL) 100025998, SNC interface of corrective action processes condition report (CR) 815684 Boron Precipitation RFI response lacks adequate technical detail, and other related condition reports and technical evaluations to evaluate the effectiveness of the licensee's corrective actions. The inspectors assessed whether the licensee properly identified, accurately and completely documented, and properly classified and prioritized the issue.

The inspectors also assessed whether the licensee adequately considered extent of condition, generic implications, common cause, and previous occurrences, adequately identified root causes and apparent causes, and identified appropriate and timely corrective actions. Also, the inspectors verified that the licensee processed the issue in accordance with procedure, ND-AD-002, Nuclear Development Corrective Action Program, Rev. 26.

b. Findings No findings were identified.

1P02 Construction QA Criterion 16

a. Inspection Scope Quarterly Resident Inspector Corrective Action Program (CAP) Routine Review The inspectors reviewed issues entered into the licensee's CAP daily to assess issues that might warrant additional follow-up inspection; to assess repetitive or long term issues; to assess adverse performance trends; and to ensure the CAP appropriately included regulatory required non-safety related SSCs. The inspectors periodically attended the licensee's corrective action program review meetings; held discussions with

53 licensee and contractor personnel; and performed reviews of CAP activities during the conduct of other baseline inspection procedures. The inspectors reviewed conditions entered into the licensee's CAP to determine whether issues were appropriately classified in accordance with the licensee's quality assurance program and CAP implementing procedures. The inspectors reviewed corrective actions associated with conditions entered into the CAP to determine whether appropriate actions to correct the issues were identified and implemented effectively, including immediate or short-term corrective actions, in accordance with the licensee's quality assurance program requirements and 10 CFR 50, Appendix B. Additionally, the inspectors reviewed corrective actions taken to determine whether they were commensurate with the significance of the associated condition in accordance with the licensee's CAP implementing procedures. The inspectors completed reviews of CAP entry logs to verify issues from all aspects of the project, including equipment, human performance, and program issues, were being identified by the licensee and its contractors at an appropriate threshold and entered into the CAP as required by the licensee's CAP implementing procedures.

b. Findings No findings were identified.

1P03 ITAAC Management

a. Inspection Scope During the week of September 24, 2018, the NRC conducted an inspection of the licensee's program for managing ITAAC closure, per IP 40600, "Licensee Program for Managing ITAAC Closure," dated July 28, 2014. Specifically, the inspection was conducted to verify the following:

the ITAAC closure process, as documented in each ITAAC notification submitted to the NRC, was adequately controlled by procedures; the ITAAC closure and ITAAC maintenance controls have been properly implemented and the resulting notifications on ITAAC accurately reflect the record of completion and maintenance of the subject ITAAC; the Quality Assurance (QA) controls for ITAAC related documentation conformed to the guidance of NEI 08-01; training requirements have been established for individuals involved with preparation, performance, approval, and audit activities for ITAAC completion packages, ITAAC Closure Notices (ICNs), and other notifications on ITAAC; ITAAC Project Managers (PMs) met the established qualification requirements and training activities; and the ITAAC notification process conformed to the regulatory requirements of 10 CFR 52.99(c).

The inspectors reviewed the detailed process established by the licensee for the generation, validation, and submittal of ITAAC notifications to the NRC. The inspectors assessed the framework provided for organization, division of responsibilities, quality

54 assurance, and final authority, as set forth in the licensee's approved procedures and instructions.

Per IP 40600, the inspectors utilized NEI 08-01 as endorsed by the NRC in RG 1.215 for guidance to verify ITAAC closure package controls were in place, which included programmatic controls for ITAAC completion, documentation, records verification, quality assurance, and notification to the NRC.

The inspectors sampled nine ICNs for both targeted and non-targeted ITAACs to verify that the licensee implemented its ITAAC closure program in accordance with approved procedures and instructions.

Specifically, for nine ICNs, the inspectors reviewed the associated ITAAC completion packages, which included the ICNs, the Principal Closure Documents (PCDs), the document transmittals, and the PCD review forms. The inspectors verified that procedural controls have been established that provide reasonable assurance that the ITAAC have been successfully performed and the acceptance criteria have been met and are being maintained. For all QA records, such as the PCDs associated with the ICNs, the inspectors verified that the documents were prepared, reviewed, approved, revised, and stored per the licensee's QA Program and as required by NEI 08-01 and site procedures.

The inspectors sampled ITAAC related Condition Reports (CRs) to verify ITAAC related issues were captured and dispositioned in the CAP. The inspectors verified that the qualification requirements and training activities had been established for the groups and individuals involved with preparation, performance, and approval for ITAAC completion packages, ICNs, and other notifications on ITAAC.

b. Findings No findings were identified.

1P04 Reporting Defects and Noncompliance - Construction

a. Inspection Scope The inspectors reviewed the implementing procedures for the procurement of safety-related components to verify compliance with 10 CFR Part 21 and 10 CFR 50.55(e).

The inspectors reviewed eight purchase orders issued by WECTEC and Georgia Power for safety-related components to verify that the documents invoked the requirements of 10 CFR Part 21 and 10 CFR 50.55 (e)(7). In all cases reviewed, the purchase orders explicitly required compliance with these regulations.

The inspectors reviewed the records retention procedures to ensure that the program met the requirements of 10 CFR 50.55(e)(9). Specifically, the inspectors reviewed procedures to determine that the licensee established retention measures for procurement documents, and records of deviations and non-compliances. The inspectors reviewed evaluation reports developed by CB&I and WECTEC dating back to 2015, for items that failed to comply with tolerance requirements, required tests, and

55 nonconforming support components. The inspectors reviewed these documents to verify that the licensee evaluated deviations, reported defects and noncompliances, and retained records in accordance with 10 CFR 50.55(e)(9).

b. Findings No findings were identified.
4.

OTHER INSPECTION RESULTS 4OA5 Other Activities

.01 Non-Cited Violation (NCV)05200025/2017002-01 and 05200026/2017002-01, "Thermal Stress Analysis Not Performed for 14-inch ADS Squib Valves IAW with ASME Section III Closure

a. Inspection Scope During a previous inspection documented in integrated inspection reports 05200025/2017002 and 05200026/2017002, the inspectors identified an ITAAC finding of very low safety significance (Green) and associated NCV for SNC's failure through their contractor WEC to perform thermal stress analysis in the ASME design report for the shear cap and valve body of the 14-inch fourth stage ADS squib valves, RCS-PL-004A/B/C/D (NCV 05200025/2017002-01 and 05200026/2017002-01, "Thermal Stress Analysis Not Performed for 14-inch ADS Squib Valves IAW with ASME Section III"). The inspectors determined that the ASME design report contained insufficient detail to show that the 14-inch ADS squib valves satisfy the thermal stress requirements. The RCS design transients evaluated both pressure and temperature variations resulting from design transients; however, the temperature variations were not appropriately transcribed to the plant and system transients for the squib valves and incorporated in the ASME design report. The inspectors determined that the following ASME Section III requirements were not met: subparagraphs NB-3222.2, Primary Plus Secondary Stress Intensity and NB-3222.4, Analysis for Cyclic Operation for the shear cap, and subparagraph NB-3545.3, Fatigue Requirements for the valve body. These NCVs were left open during the time of the inspection pending completion of corrective actions to show that compliance was restored and the acceptance criteria of Unit 3 and Unit 4 ITAAC 13 was not impacted. These corrective actions included additional analysis and revisions to the ASME design report and supporting documents.

During the week of September 3, 2018, the inspectors reviewed corrective action documents, design reports, transient analyses, calculations, and E&DCRs to determine if corrective actions for NCV 05200025/2017002-01 and 05200026/2017002-01 were taken to show that compliance was restored and the acceptance criteria of Unit 3 and Unit 4 ITAAC 13 was not impacted.

The inspectors reviewed corrective action documents to determine if the licensees responses and stated corrective and preventative actions were timely and appropriate, and if corrective actions have been fully implemented. The inspectors reviewed the

56 corrective action documents to determine if they referenced the appropriate thermal stress requirements in accordance with the ASME Code,Section III, and if the need for document revision was identified based on the findings identified in NCV 05200025/2017002-01 and 05200026/2017002-01.

The inspectors reviewed transient analyses, calculations, and E&DCRs to determine if plant and system thermal transients affecting the fourth stage ADS squib valves were analyzed in accordance with the UFSAR and translated into component specific transient documents. The valve vendor revised the ASME design report to include additional thermal transients, which was reviewed and accepted by WEC and SNC. The inspectors reviewed the revised ASME design report for the fourth stage ADS squib valves to determine if thermal transients were included as inputs in the calculation of thermal stresses to the valve body and shear cap, and if the thermal stress analyses met the ASME Code,Section III requirements.

The condition for failure to perform a thermal analysis no longer exists nor impacts the acceptance criteria of the ITAAC therefore, NCV 05200025/2017002-01 and 05200026/2017002-01 is considered closed.

b. Findings No findings were identified.

.02 NCV 05200025/2016004-01 and 05200026/2016004-01, Failure to Identify Nonconforming Embed Plate Welds Closure

a. Inspection Scope During a previous inspection documented in integrated inspection reports 05200025/2016004 and 05200026/2016004, the inspectors identified an ITAAC finding of very low safety significance (Green) and associated NCV for the licensees failure to identify nonconforming welds between seismic category I embed plates and structural modules inside the Vogtle Unit 3 and Unit 4 containment buildings (NCV 05200025/2016004-01 and 05200026/2016004-01, Failure to identify nonconforming embed plate welds). The inspectors determined that QC inspectors failed to identify that welds did not have thorough fusion between adjacent layers of weld metal, and therefore did not meet the visual acceptance criteria established by the AWS D1.1:2000 and AWS D1.6:1999 Codes. During the time of the inspection, the licensee was performing an extent of condition inspection to determine if additional welds were affected. These NCVs were left open during the time of the inspection pending completion of the extent of condition and corrective actions to show that compliance was restored and the acceptance criteria of Unit 3 and Unit 4 ITAAC 760 was not impacted. The inspector's finding and completion of the extent of condition inspection performed by the licensee identified a total of 37 welds that were not in compliance with AWS Code: 19 welds in Unit 3 CA01, 8 welds in Unit 3 CA02, 4 welds in Unit 4 CA01, and 6 welds in CA05.

During the week of September 3, 2018, the inspectors reviewed corrective documents, N&D reports, weld repair records, NDE examination records, and qualification records to determine if licensee corrective actions for NCV 05200025/2016004-01 and

57 05200026/2016004-01 were taken to show that compliance was restored and the acceptance criteria of Unit 3 and Unit 4 ITAAC 760 was not impacted.

The inspectors reviewed corrective action documents to determine if the licensees responses and stated corrective and preventative actions were timely and appropriate, and if corrective actions have been fully implemented. The inspectors reviewed the corrective action documents to determine if all welds identified in the inspectors findings and licensees extent of condition were documented in N&D reports, and if the weld repair and NDE actions taken were in accordance with the applicable AWS Code and ANSI/AISC N690-1994.

For the 37 weld repairs, the inspectors reviewed weld data sheets to determine if weld repairs were documented for the welds identified in corrective action documents and N&D reports. The inspectors reviewed the weld data sheets to determine if welders signatures were documented for repairs preformed in accordance with the licensees welding control procedure, inspection hold points were identified in accordance with AWS Code and the welding control procedure, and QC inspectors signatures and associated reports were documented in accordance with the welding control procedure.

The inspectors reviewed NDE reports (MT, PT, and UT) for the 37 weld repairs to determine if NDE was performed and met acceptance criterion in accordance with the licensees NDE procedures. The inspectors reviewed the structural weld inspection plan used to perform visual inspections of the weld repairs to determine if the visual inspection acceptance criteria of AWS D1.1:2000 and AWS D1.6:1999 Codes were included in the inspection plan. In addition, the inspectors reviewed a sample of VT, PT, MT, and UT qualification records to determine if QC inspectors were qualified for the inspections performed.

The condition for failure to identify and correct non-conforming welds no longer exists nor impacts the acceptance criteria of the ITAAC, therefore NCV 05200025/2016004-01 and 05200026/2016004-01 is considered closed.

b. Findings No findings were identified.

4OA6 Meetings, Including Exit

.01 Exit Meeting On October 12, 2018, the inspectors presented the inspection results to Mr. J. Klecha, Vogtle Vice President, and other licensee and contractor staff members. Proprietary information was reviewed during the inspection period, but was not included in the inspection report.

SUPPLEMENTAL INFORMATION KEY POINTS OF CONTACT Licensee and Contractor Personnel R. Givens, SNC Document Control Supervisor T. Neal, SNC Procedures and Document Services Supervisor D. Gardner, SNC Licensing Lead C. Castell, SNC Licensing Engineer G. Scott, SNC Licensing Engineer L. Pritchett, SNC ITAAC Project Manager R. Beilke, SNC ITAAC Project Manager T. Petrak, SNC ITAAC Manager K. Stacy, SNC Licensing Supervisor LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED Item Number Type Status Description 05200025/2017002-01 NCV Closed Thermal Stress Analysis Not Performed for 14-inch ADS Squib Valves IAW with ASME Section III 05200026/2017002-01 NCV Closed Thermal Stress Analysis Not Performed for 14-inch ADS Squib Valves IAW with ASME Section III 05200025/2016004-01 NCV Closed Failure to Identify Nonconforming Embed Plate Welds05200026/2016004-01 NCV Closed Failure to Identify Nonconforming Embed Plate Welds LIST OF DOCUMENTS REVIEWED Section 1A01 ASME Code Section III-98 Edition including 00 addenda; Subsection NCA-1210, -3250, and 3520; and Subsection NB-3130, -3200 for Class 1 Components NQA-1-1994, Part II, Subpart 2.15, Quality Assurance Requirements for Hoisting, Rigging, and Transporting of Items for Nuclear Power Plants APP-MV20-Z0-100, AP1000 Pressurizer Design Specification for RCS System, Revision 11 APP-MV20-VHM-001, AP1000 Pressurizer Technical Manual: Instructions for Receipt Inspection, Storage and Assembly, Revision 0 SV3-MV20-MHH-001, Rigging Plan - Field Copy, Revision 0

2 Section 1A02 WEC APP1000 Fabrication and Installation Specification APP-PH02-Z0-002, "AP1000 ASME Section III Class 1, 2 and 3 Pipe Supports/Tubing Supports," Revision 4 WEC Document APP-GW-P1-027, "Lisega Standard Component Installation and Operation Information," Revision 1 Isometric Construction Drawing APP-RCS-PLW-041, "Reactor Coolant System Containment Bldg Rooms 11303/1304, Surge Line-Spool Piece 1," Revision 4 Isometric Construction Drawing APP-RCS-PLW-042, "Reactor Coolant System Containment Bldg Room 11303, Surge Line-Spool Piece 2," Revision 3 Isometric Construction Drawing APP-RCS-PLW-043, "Reactor Coolant System Containment Bldg Rooms 11303/1304, Surge Line-Spool Piece 3," Revision 4 Drawing APP-RCS-PH-11V01011, "Pipe Support Drawing RCS System RCS-PH-IIV0101,"

Revision 3 Drawing APP-RCS-PH-11C01021, "Pipe Support Drawing RCS System RCS-PH-11C0102,"

Revision 2 Drawing APP-RCS-PH-11Y101031, "Pipe Support Drawing RCS System RCS-PH-11Y0103,"

Revision 2 Section 1A03 WEC Isometric Drawing SV3-PXS-PLW-080-R0, "Passive Core Cooling System Containment Building Room 11305 ADS Piping to Sparger B", Rev. 0 WECTEC Weld Data Sheet (WDC) SV3-PXS-PLW-080-5 for work package SV3-PXS-P0W-800033, 8-8-2018 Lincoln Electric CMTR-No. 6338965 ES-RAXM for Lot-No. 1203E, SFA-5.9 ER308/308L, 1/8" dia., April 10, 2015 Lincoln Electric CMTR-No. 6338965 ES-RAXL for Lot-No. 1203F, SFA-5.9 ER308/308L, 3/32" dia., April 14, 2015 S&W Record of Welder Performance Qualification Test (WPQ) - ASME Section IX with GTAW 1CS-02 for JDC6055 (06/12/2018), and GTAW 1SS-02 for BAP7990 (06/28/2018), DJK5939 (03/29/2017), and JJ9039 (04/11/2018)

Section 1A04 Design Specification, Drawings and Purchase Order WEC Design Specification APP-PV10-Z0-001, Ball and Plug Valves, ASME Boiler & Pressure Code Section III, Class 2 and 3, Revision 7 WEC Purchase Order 4500312904 Change Notice 20, dated October 17, 2012, to Crane Nuclear for procurement of 2-inch Plug Valve Air Operated WEC Drawing APP-PV10-V0-014, Air-operated plug Valve 2 Class 150, Butt Weld Envelope Dimensions, Revision 2 WEC Data Sheet APP-PV10-Z0D-141, PV10 Datasheet 141, Revision 1 Crane Nuclear Design Report, CNI Report No. DR-157, 2-inch Class 150 Plug Valve, Air Operated, Assembly No. CD04805-00N2, Datasheet No. APP-PV10-Z0D-141, Revision 9, dated September 6, 2012 Crane Nuclear Design Report CNI Report No. DR-157-RECON-3, Revision 0, dated November 19, 2012 WEC purchase order No. 4500327665, change order 19, dated February 24, 2015, issued to Fisher Control INTL Inc., for procurement of 1 Class 150 Globe Valve WEC drawing APP-PV14-V2-105002, PV14 Datasheet 105 Assembly Drawing, Revision 1 WEC Design Specification APP-PV14-Z0-001, Air Operated Globe and Stop Check Valves, ASME Boiler and Pressure Vessel Code,Section III, Class 1, 2, and 3, Revision 7

3 WEC Datasheet APP-PV14-Z0D-105, PV14 Datasheet 105, Revision 3 Fisher Control Design Report 11QN09-DR-02, Design Report for Class 2 Components per ASME Sec. III, Div. 1, 1998 Ed., 2000 Add., Revision A Quality Assurance Documents WEC Quality Release & Certificate of Conformance No. QR-13-641, Revision 3, March 27, 2015 WEC Quality Release & Certificate of Conformance No. QR-13-641, Revision 0, February 21, 2013, with Contingent Quality Report No. CQR-879 Revision 0 WEC Quality Release & Certificate of Conformance No.13-641, Revision 1, September 4, 2014, for Contingent Report No. 879, Revision 1 WEC Quality Release & Certificate of Conformance No.13-641, Contingent Report No. N/A, Revision 2, January 5, 2015 Crane Nuclear Certificate of Compliance for 2-inch Model CTXP-1 Class 150 AOV Plug Valve Assembly VDS: APP-PV10-Z0D-141 Rev. 1 S/N E2267, dated February 18, 2013 ASME Form NPV-1, Certificate Holders Data Report for Nuclear Pumps or Valves, for 2 x 2 Plug Valve, September 9, 2014 WEC Quality Release and Certificate of Conformance QR-15-1105 Rev.0, Continent QR# 1408, Revision 0, dated April 24, 2015 WEC Quality Release and Certificate of Conformance QR 15-1105, Rev. 0, dated April 24, 2015 Fisher Controls Manufacturers Certification 0987790VOG, for 1 HPNS Globe Valve Assembly S/N 19089917, Tag No. APP-PV14-Z0D-105, April 2, 2015 Fisher Controls Design Report Review Certification for Valve S/N 0019089917, 1 Class 150 HPNS w/Schedule 80S BWE Valve Body, February 26, 2016 Fisher Controls Certification of Conformance and Material Certification dated April 27, 2015 ASME Form NPV-1, Code Data Report for 1 HPNS Globe Valve, dated April 29, 2015 Material Records CMTR I06248CI for valve body S/N E2203, Heat # 0779-2, May 3, 2011 CMTR I06249CI for valve bonnet S/N E2202, Heat # E1915-8, December 18, 2012 CMTR 126666 for bonnet studs, Heat # 900174, Trace Code 4X01, November 1, 2010 CMTR 127359 for bonnet nuts, Heat # 242828, Trace Code 4Y12, November 2, 2010 CMTR 285861 for plug stem, S/N E0374, Heat # S83662, Trace No. 38203, November 19, 2010 CMTR 4123334527 for Body P/N GE44017X052, Heat No. I1159 SN65, February 24, 2012 CMTR 138299 for Bonnet P/N GE44371X062, S/N AA006034, Heat No. JNRP SN41, June 5, 2014 CMTR 57163 for Plug Block S/N AA008118, 1-1/2 diameter round bar x 29.1 long Heat No.

12123868-4, dated July 10, 2014 CMTR 0043362 for Stem S/N AA007927, Heat No. G19148, dated August 29, 2012 CMTR 299971 for Stud Bolts P/N 1J9582X0252 Heat No. C4A93 Trace Code 04Z1, dated November 21, 2014 CMTR 298680 for Hex Nuts P/N 1A4452X2302 size 1 1/8-8 UN 2B, heat No. 52186-1VBA, Trace Code 04A5, dated November 3, 2014 CMTR 138299 for weld wire WT-6H Alloy ERCoCr-A size 1/16 diameter x 36length Heat No.

07-1665, ASME SFA5.21, dated November 2, 2007 Stoody Certificate of Analysis No. 243034 dated May 9, 2013, for weld wire size 1/8 diameter ERCoCr-A Stoodite 6H MOD Lot No. 4AW30B, certified to AWS A5.21 Keokuk Steel Casting Heat Treat Certificate of Bonnet P/N GE44371X062, dated June 24, 2014 Carboline Certificate of Conformance No. 1098176-3 dated December 5, 2013, for Carboguard 890N P/N 1M6095X0022

4 Hydrostatic Test and NDE Records Hydrostatic Test Report for 2-inch plug valve, S/N E2267, dated January 16, 2013 Pneumatic Seat Test Report for 2-inch plug valve S/N E2267, dated January 16, 2013 Production Test Summary Report, CNI Report No. TR-037, Revision 0, dated January 21, 2013 Liquid Penetrant Examination Report on Body P/N. 35740-08, Heat No. E2203, October 22, 2012 Liquid Penetrant Examination Report on Bonnet P/N 35740-08, Heat No. E2202, October 23, 2012 Liquid Penetrant Examination Report on Plug P/N 37194-01N, Heat No. E0371, November 26, 2012 LTI Ultrasonic Examination Report for Stem material 2-1/2-inch diameter x 23 long round bar, Alloy 718, Heat No. S83662, October 28, 2010 Ultrasonic Examination Report for Stem material 2-1/2-inch diameter x 51-1/2 long round bar, Alloy 718, Heat No. S83662, October 28, 2010 Fisher Controls NDE Surface Examination Report, Liquid Penetrant Examination of Bonnet Hardface Backseat S/N AA006034, Heat No. JRP SN41, January 6, 2015 NDE Surface Examination Report NMR 6701, Liquid Penetrant Examination of Plug/Stem Assembly S/N AA008118, of seating surface dated December 22, 2014 NDE Surface Examination Report NMR 6751, Liquid Penetrant Examination of Plug/Stem Assembly S/N AA008118, of plug/stem weld dated December 9, 2014 NDE Surface Examination Report NMR 6601, Liquid Penetrant Examination of Plug/Stem Assembly S/N AA008118, of all accessible finished machine surface dated December 22, 2014 NDE Surface Examination Report NMR 901, Liquid Penetrant Examination of all accessible finish machine surface of Plug S/N AA008118, Heat No. 12123868-4, October 22, 2014 NDE Surface Examination Report NMR 501, Liquid Penetrant Examination of all accessible finish machine surface of Stem S/N AA007927, Heat No. G19148, October 14, 2014 METCO Penetrant Inspection Report dated August 9, 2014, on Fisher Control round NITRONIC bar HT No. G19148 for Stem S/N AA007927 NDE Surface Examination Report 2401 for Actuator Stem P/N GE57682X052, S/N AA004511, dated November 1, 2014 NOVA Machine Liquid Penetrant Report 272914-6100 for 1-1/8-8 x 5 studs, Heat C4A93, Trace Code 04Z1, dated October 28, 2014 NOVA Machine Liquid Penetrant Report 271620-5100 for 1-1/8-8 UN-2B heavy hex nut, Heat 52186-1VBA, Trace Code 04A5, dated October 8, 2014 Nuclear Paint Report Carbozinc 11 HSN for Yoke, Lower and Upper Casing, dated January 13, 2015 Valve test report No. 004 -X012149977, for seat leak, pneumatic seat leak and hydro test, dated January 16, 2015 Valve Operational test report No. 11QN10-FR-02.01, FlowScanner Result Summary Report, for 1 Class 150 HPNS Globe Valve with 667NS2 Size 45A Diaphragm Actuator, Revision B, dated February 26, 2015 Dimensional Inspection Reports Dimensional Inspection Report for Valve Item No. 35740-08, 2 Plug Valve Assembly, S/N E2267, February 11, 2013 Minimum Wall Record Plug Valve BodyButtweld End, for Body S/N E2203, September 26, 2012 Dimensional Inspection Report for Body S/N E2203, October 29, 2012 Minimum Wall Record Bonnet, for Bonnet S/N E2202, September 26, 2012 Dimensional Inspection Report for 2 Bonnet S/N E2202, October 30, 2012 Dimensional Inspection Report for 2 Plug S/N E0371, January 18, 2011

5 Critical Dimensional Inspection Report Data Sheet 105, for Fisher Valve S/N 0019089917, dated April 2, 2015 Inspection Test Report for Valve Body P/N GE44017X052, dated February 26, 2014 Inspection Test Report for Bonnet P/N GE44371X062, S/N AA006034, dated February 24, 2014 Minimum Wall Thickness Report for Valve Body P/N GE44017X052, S/N AA005064, Heat No.

I1159 SN65, December 15, 2014 Design Reconciliation Review Form for Valve Body casting P/N GE44016X11A, S/N AA005064, Heat No. I1159 SN65, July 9, 2014 Minimum Wall Thickness Report for Bonnet P/N GE44371X062, S/N AA006034, Heat No.

JNRP SN41, December 12, 2014 Fisher Control Inspection and Test Report (ITR) No. 0987790VOG-ITR-3-3, for Plug block P/N GE45476X032, S/N AA008118, Heat No. 12123868-4, dated October 2, 2014, Fisher Controls ITR No. 0987790VOG-ITR-3-12, for Plug/Stem Assembly P/N GE45478X032, S/N AA008118, dated September 10, 2014 Weld Records Fisher Weld Order Record for Bonnet S/N AA006034 with hardface of bonnet seat dated October 16, 2014 Fisher Weld Order Record for Plug/Stem Assembly S/N AA008118, of welding stem to plug, dated November 17, 2014 Deviation Notices WEC Procurement Advisory Release (PAR) No. 4500312904-192-0, for CNI Deviation Notice No. 35740-0032, Deviation Notice for Cleaning Procedure CL-1, dated February 11, 2011 WEC Deviation Notice (DN) No. AP-PV10-008, DN10-006 Contingent Release to Ship Prior to Final Approval of EQ Reports, Revision 1, May 28, 2013 PAR No. 4500312904-167-0, Deviation Notice for PV10 Datasheet APP-PV10-Z0D-141 Envelope Drawing, VDS141, DN-PV10-008, dated December 5, 2012 PAR No. 4500312904-154-0, Deviation Notice for Contingent Release, VDS141, DN-PV10-006, dated November 28, 2012 PAR No. 4500312904-090-0, for CNI Deviation Notice No. 35739-0028, Deviation Notice for Hardened Washers, dated December 20, 2010 DN PV10-006, Contingent Release to Ship Prior to Final Approval of EQ Reports, October 30, 2012 DN APP-PV10-GNR-008, Deviation Notice for Contingent Release for Data Sheet 141, Rev. 1, May 25, 2013 WEC APP-PV14-GNR-005, Deviation Notice for PV14 Cycle Testing, Revision 0, approved on June 2, 2014 WEC APP-PV14-GNR-006, Deviation Notice for PV14 root pass weld NDE, Revision 0, approved on February 26, 2015 WEC APP-PV14-GNR-007, Deviation Notice for Contingent Quality Release of PV14 Module Valves, approved on April 2, 2015 WEC APP-PV14-GNR-013, Deviation Notice for PV14 Coating, Revision 0 Fisher Document No. 11QN10-DR-02.01, Supplemental Non-Conformance Reconciliation for Code Design Report No. 11QN09-DR-02, Revision B, dated February 9, 2016 Section 1A05 APP-FT01-Z0-001, AP1000 Fuel Transfer Tube, ASME Boiler and Pressure Vessel Code Section III, Subsection NE, Class MC, Revision 3

6 WEC-Newington Operations, Form N-2 Certificate Holder's Data Report for Identical Nuclear Parts and Appurtenances (transfer tube, flange, test angle, and hatch), Part Serial No. 6046, 5/25/18 Fuel Transfer Tube (WEC Ident. No. 15-0517, Material-No. FT01-V2-531-01-1):

Outokumpu Stainless Steel LLC, CMTR 0288571-01, heat & piece 859405 - 6A, 11/13/14 Bristol Metals LLC, CMTR for 30" dia. X 0.375" min. wall thickness pipe, SA312 TP304/304L, heat/Lot-no. 859405/132291 (WEC ID-No. 15-0517), 01/23/2015 Brismet Radiographic Examination Report 30P-.375-3/4, heat# 859405, actual mat'l thick.

0.423", certified by Level II, 1/15/15 WEC Liquid Penetrant Examination Report NDE-040889, transfer tube (SDCR 11020 Repair),

WEC Ident. No. 15-0517, Material-No. FT01-V2-531-01-1, by Level II Inspector, 10/16/15 WEC Radiographic Examination Report NDE-040927, transfer tube joint 1 (SDCR 11020 Repair), WEC Ident. No. 15-0517, 14 film locations, Signed by Level II & III, and ANI, 10/20/2015 Flange (WEC Ident. No. 14-1584, Material-No. FT01-V2-531-01-2S):

Element Materials Technology, CMTR ENE022-07-18-25550-1, SA182 F304L, Heat Number H632, 7-23-14 Energy & Process Corporation Element, CMTR for 38.5" OD X 27.5" ID X 5.5" Thk, SA182 F304L (Qty. 2), heat: H632, 7/30/14 Test Angle (WEC Ident. No. 15-1445, Material-No. B01.250P041):

Energy & Process Corporation Element, CMTR 46621C for 1/4" thick plate, Heat W1J3, Lot (Jacket Fiche) 55403, SA240 Type 304L, 09/18/15 Hatch (WEC Ident. No. 14-1980, Material-No. M3X7 (PC) 1):

Energy & Process Corporation Element, CMTR 43512C for 2" thick X 34" dia. plate, Heat M3X7, Lot (Jacket Fiche) 52202, SA240 Type 304L, 09/26/14 Weld Filler Metals :

ESAB, CMTR 2-49251-00-0-A, SFA-5.22, E308T1-4/308LT1-4,.045" dia, WEC Ident. No. 2152, Lot-No. 15979, 04/13/2010 Arcos, CMTR 114204, SFA-5.9, ER308/308L,.035" dia, WEC Ident. No. 2155, Heat-No.

740400, Lot-No. XT9336, 11/16/2010 Amended Arcos, CMTR 140798, SFA-5.9, ER308/308L, 1/16" dia, X 36", WEC Ident. No. 2253, Heat-No.

537291, Lot-No. AF0029, 6/5/2014 Weldstar, Certificate of Compliance/Conformance, Arcos, SFA-5.9, ER308/308L, 1/16" dia, X 36", Heat-No. 537291, Lot-No. AF0029, June 5, 2014 Lincoln Electric Company, CMTR 6697050 ES-TADC, SFA-5.9, ER308/308L, 3/32" X 36", Heat-No. 539207, Lot-No. 1212C, 24 Sept 2014 Weld Maps, NDE reports, and Test Reports :

WEC Weld Map No. WM-2412284-01, Rev. 03, Titled "FT01-Fuel Transfer Tube", Reference Drawing APP-FT01-V2-531, 7 pages, 4-27-16 WEC Weld Map No. WM-2412284-10, Rev. 01 Titled "FT01 Fuel Transfer Tube Assembly",

Reference Drawing APP-FT01-V2-530, 6 pages, 6-30-16 NDE Report for VT and PT for Assy # A1, Joints 1 thru 11 with reference document Weld Map-2412284-01, accepted by Level II Inspectors 116 and 149, SV3-F01-VQQ-001, pages 1724-1727, 5-9-18

7 NDE Report for VT and PT for Assy # A1, Joints 1 thru 3 with reference document Weld Map-2412284-10, accepted by Level II Inspector 147, SV3-F01-VQQ-001, page 1734, 5-9-18 WEC Pneumatic Test Report for Weld Ident. No. 2412284, at 67 psi for 10 min., signed by Level II Inspector 81, 06-28-17 WEC Hydrostatic Test Report NDE-049205 for Weld Ident. No. 2412284 Assy A1, at 74 psi for 10:36, signed by Level II Inspector 116, 07/11/2017 WEC Fuel Transfer Tube Functional Testing Test Report WEC Ident. No. Assy A1, signed by Level II Inspector 32, 12-7-17 Section 1A06 SV3-EY01-V0M-100, "Vogtle Unit 3&4 Electrical Penetration Assembly (EPA) Multipurpose Manual: EPA installation and Maintenance Manual", Rev. 1 SV3-EY01-V0-001, "Vogtle Units 3&4 Electrical Penetration Assembly (EPA) Multipurpose:

Medium Voltage Power EPA Drawings", Rev. 1 SV3-EY02-Z0D-011, "Specification Datasheet for Non-1E Medium Voltage EPA", Rev. 1 SV3-EY01-Z0D-020, "Specification Datasheet for Class 1E I&C electrical penetration assemblies", Rev. 3 Section 1A07 Drawings APP-KB36-V0-001, Module 1231-KB-36 PCS Pump/Valve Module Drawing Index, Revision 6 APP-KB36-V1-401, Module 1231-KB-36 PCS Pump/Valve Module General Outline Equipment List and Notes, Revision 2 APP-PCS-M6-002, Piping and Instrumentation Diagram Passive Containment Cooling System, Revision 11 APP-PCS-PLW-10A, Passive Containment Cooling System Auxiliary Building Room12306 Piping in Module 1231-KB-36, Revision 4 APP-PCS-PLW-10F, Passive Containment Cooling System Auxiliary Building Room12306 Piping in Module 1231-KB-36, Revision 2 APP-PCS-PLW-10J, Passive Containment Cooling System Auxiliary Building Room12306 Piping in Module 1231-KB-36, Revision 1 SV0-PV03-V2-109001, AP1000 Manually Operated Gate Valve 4 Class 150 Assembly Drawing APP-PV03-Z0D-109, Revision 1 SV0-PV03-V2-109002, AP1000 Manually Operated Gate Valve 4 Class 150 Assembly Drawing APP-PV03-Z0D-109, Revision 0 Design Specifications APP-PL02-Z0-102, AP1000 Class 2, 3 Piping and B31.1 Extensions Design Specification, Revision 4 APP-PV02-Z0-001, 2 and Smaller Manually Operated Globe and Check Valves, ASME Boiler and Pressure Vessel Code,Section III, Class, 1, 2 and 3, Revision 13 APP-PV03-Z0-001, Design Specification for 3 and Larger Manually Operated Gate, Stop Check, and Check Valves, ASME Boiler and Pressure Vessel Code,Section III, Class, 1, 2, and 3 for Various Systems, Revision 9 Fabrication Specifications APP-GW-VLR-002, Technical Requirements of Stainless Steels, Nickel-Base Alloys, Carbon and Low Alloy Steels, and Welding Materials for the AP1000, Revision 2 APP-GW-VLR-010, AP1000 Supplemental Fabrication and Inspection Requirements, Revision 2

8 Nonconformance Reports APP-KB36-GNR-850050, dated February 15, 2017 APP-KB36-GNR-850051, dated February 15, 20 17 APP-KB36-GNR-850062, dated January 5, 20 17 APP-KB36-GNR-850128, dated May 4, 2017 APP-KB36-GNR-850141, dated June 2, 2017 SV0-PV03-GNR-002, dated March 20, 2018 Fabrication Records in QADP SV3-PV02-VQQ-004, Valve PCS-V015 (Serial No. SF1107-0025), Revision 3 QR-12-241, Westinghouse Quality Release & Certificates of Conformance, Revision 3 DN-PV02-VG-006, Quality Assurance (QA) Records Data Package Index, Revision 0 Form NPV-1 Certificate Holders Data Report for Nuclear Pumps of Valves, Manufactured and certified by Samshin Limited, Manufactured for Westinghouse Electric Company, Valve Serial No. SF1107-0025, dated November 16, 2011 CMTR-PV02-VG-11-002, ASME SA182-F304L, Heat No. GX-2/1 (Source Material Heat No.

A30126), dated August 29, 2011 CMTR 10511-2240, ASTM A276M 304/304L, Heat No. A30126, dated May 11, 2011 CMTR-PV02-VG-11-013, ASME SA182-F304L, Heat No. GY-1/1 (Source Material Heat No.

S98683), dated August 29, 2011 CMTR 10511-2240, ASTM A276M 304/304L, Heat No. S98683, dated July 11, 2011 CMTR-PV02-VG-11-014, ASME SA479-304L, Heat No. HH-1 (Source Material Heat No.

S85180), dated August 29, 2011 CMTR 10511-2240, ASTM A182 F304L, Heat No. S85180, dated June 10, 2019 CMTR TR-S1001, ASME SFA-5.9 ER308L, Heat No. E63398, dated December 28, 2009 HTR-5-1107-004, Heat Treatment Record, Heat Nos. GX-2/1 and GY-1/1, dated September 29, 2011 11-SSV-P502, Liquid Penetrant Examination Report, Heat No. GX-2/1, On Root Pass of Weldments, dated September 1, 2011 11-SSV-P503, Liquid Penetrant Examination Report, Heat No. GY-1/1, On Root Pass of Weldments, dated September 1, 2011 11-SSV-P504, Liquid Penetrant Examination Report, Heat No. HH-1, On Root Pass of Weldments, dated September 1, 2011 11-SSV-P577, Liquid Penetrant Examination Report, Heat No. GX-2/1, On Hardfaced Surface &

Adjacent Base Material, dated September 7, 2011 11-SSV-P578, Liquid Penetrant Examination Report, Heat No. GY-1/1, On Hardfaced Surface &

Adjacent Base Material, dated September 6, 2011 11-SSV-P579, Liquid Penetrant Examination Report, Heat No. HH-1, On Hardfaced Surface &

Adjacent Base Material, dated September 7, 2011 11-SSV-P684, Liquid Penetrant Examination Report, Heat No. GX-2/1 + GY-1/1, On Hardfaced Surface & Adjacent Base Material, dated September 28, 2011 PTR-PV02-VG-131-01-1, Pressure Test Report, Serial No. SF1107-0025, dated November 1, 2011 WR-103065-11-21, Welding Record, Body + Bonnet, TS-III-VG-PV02-131-1, ER308L, Heat No.

E63398, dated September 29, 2011 WVD-VG-006, Welding Verification Documentation, Seal Welding on Body to Bonnet Fabrication Records in QADP SV3-PV03-VQQ-005, Valve PCS-V005 (Serial No. BK-489),

Revision 2 QR-12-2032, Westinghouse Quality Release & Certificates of Conformance, Revision 2

9 Form NPV-1 Certificate Holders Data Report for Nuclear Pumps of Valves, Manufactured and certified by Flowserve Corporation, Manufactured for Westinghouse Electric Company, Valve Serial No. BK-489, dated September 14, 2012 CMTR M1371/SUP-4, ASME SA351 GR CF3M, Heat No. M1371 Serial No: 2, dated November 12, 2010 CMTR K9904-1, ASME SA 182 F316, Heat No. 251426, dated December 21, 2010 CMTR M1371/SUP-5, ASME SA351 GR CF3M, Heat No. M1371 Serial No: 5, dated November 12, 2010 CMTR 041274999117602, ASME SA-453 Grade 660 Class B, Heat No. 352, dated December 10, 2010 CMTR 041226279117602, ASME SA-194 Grade 8, Heat No. 460, dated December 30, 2010 CMTR TA-1989, ASME SFA 5.4 E308L-16, Heat No. 526226, dated August 12, 2011 CMTR QSC-488, ASME SFA 5.9 Class ER308L, Lot No. D4790R308L, dated January 30, 1985 Weld Process Report for 91176-02, Serial No. M1371-2, Fillet, 308, Lot No. D4790R308L, dated August 22, 2011 Weld Process Report for 91176-02, Serial No. M1371-2, Body Groove Weld, E308L-16, Heat No. 526226, Lot No. 116110, dated August 23, 2011 91176-02, Liquid Penetrant Examination for Serial No. M1371-2, Root Pass, dated August 21, 2011 91176-02, Liquid Penetrant Examination for Serial No. M1371-2, PT Seat Ring to Body Welds, dated August 24, 2011 ADD1956, Liquid Penetrant Examination, Serial No. M1371-2, 4 CL 150 FW Body Casting, dated March 12, 2010 ARD 2389, Radiography Test Report, Serial No. M1371-2, 4 CL 150 FW Body Casting, dated November 29, 2010 ARD 2437, Radiography Test Report, Serial No. M1371-5, 4 CL 150 FW Gate Casting, dated November 29, 2010 36-Q-1129, Assembly & Test Data Sheet, Pressure Seal Gasket No. BK 489, Heat No. M1371-2, Revision 7 Fabrication Records in QADP SV3-PV03-VQQ-006, Valve PCS-V039 (Serial No. BK-560),

Revision 2 QR-12-2240, Westinghouse Quality Release & Certificates of Conformance, Revision 2 Form NPV-1 Certificate Holders Data Report for Nuclear Pumps of Valves, Manufactured and certified by Flowserve Corporation, Manufactured for Westinghouse Electric Company, Valve Serial No. BK-560, dated October 19, 2012 CMTR M1459/SUP-1, ASME SA351 GR CF3M, Heat No. M1459 Serial No: 4, dated July 1, 2010 CMTR 285855, ASME SA-240 316, Heat No. E79578, dated November 10, 2010 CMTR K9795-1, ASME SA 182 F316, Heat No. 251426, dated December 21, 2010 CMTR 041268889117617, ASME SA-453 Grade 660 Class B, Heat Code 337, Heat No.

250337 dated December 10, 2010 CMTR 041089229117624, ASME SA-194 Grade 8, Heat No. 028, dated December 29, 2010 CMTR TA-1756, ASME SFA 5.4 E308L-16, Heat No. E91345, dated March 5, 2010 CMTR QSC-488, ASME SFA 5.9 Class ER308L, Lot No. D4790R308L, dated January 30, 1985 Weld Process Report for 91176-17, Serial No. M1459-4, Root Pass, 308L, Lot No.

D4790R308L, dated August 8, 2011 Weld Process Report for 91176-17, Serial No. M1459-4, Final Pass, E308L-16, Heat No.

L91345, Lot No. 003920, dated August 11, 2011 91176-17, Liquid Penetrant Examination for Serial No. M1459-4, Root Pass, dated August 10, 2011

10 91176-17, Liquid Penetrant Examination for Serial No. M1459-4, Seat Ring to Body Welds, dated August 21, 2011 ADD2081, Liquid Penetrant Examination, Serial No. M1459-4, 4 CL 150 SCV Body, dated July 1, 2011 ARD 2535, Radiography Test Report, Serial No. M1459-4, 4 CL 150 SCV Body, dated December 30, 2010 36-Q-1129, Assembly & Test Data Sheet, Pressure Seal Gasket No. BK-560, Heat No. M1459-4, Revision 5 Valve Weld Installation Records from CB&I Laurens Shop Travelers for Sketch numbers: 890700-40.01-00005, 890700-40-01-00045, 890700 01-00007 Weld Filler Metal CMTRs for heat numbers: AF9689 (7/30/12), CT9742 (11/16/12), DF0140 (1/30/15), CT9617 (6/15/12)

Welding Procedure AP1000-803 Revisions: 3, 7, & 8 Welding Procedure Qualification records: PRN 070 (6/15/1990), PRN 072 (4/14/1993), PRN 076 (12/11/1991)

Welder Performance Qualification Records for welder IDs: B8 (2/2/15) and B1 (10/6/11)

Liquid Penetrant Test Reports for sketch numbers: 890700-40.01-00005 (2/3/16), 890700 01-00045 (1/21/16), 890700-40-01-00007 (1/2/15)

Pipe Welding Records from Aecon Drawing SV3-KB36-PCS-PLW-03-02X Rev. 2 Weld Data Sheets: SV3-KB36-PCS-PLW-03-X36-W91 Rev. 0, SV3-KB36-PCS-PLW-03-X36-W92 Rev. 0, SV3-KB36-PCS-PLW-03-X36-W93 Rev. 0 CMTRs for weld filler metal heat numbers: 13951629 (8/5/15), 13684216 (6/17/15), 1256K (7/5/16)

Welding Procedure: 88-200-N28, Rev. 2 Welding Procedure Qualification Records: 88-20-715 (3/11/15), 88-200-712 (1/6/15)

Welder Qualification Records for welder ID 2 (8/10/16)

PT reports: PT-X36-009 (3/3/17), PT-X36-010 (3/9/17), PT-X36-015 (3/14/17)

VT Reports: VT-X36-118 (3/2/17), VT-X36-120 (3/3/17), VT-X36-138 (3/9/17), VT-X36-136 (3/14/17), VT-X36-117 (3/2/17), VT-X36-128 (3/9/17)

Pipe Spool SV3-PCS-PLW-10A-1A Sketch No. 890700-40-01-00045, Line No. PCS-PL-L051 and L065, Pipe Spool Serial No. SV3-PCS-PLW-10A-1B and -1C, Heat No. F119136, Revision 1A Form NPP-1, Certificate Holders Data Report for Fabricated Nuclear Piping Assemblies, Fabricated and certified by CB&I Laurens, Fabricated for CB&I Stone and Webster, Serial No.

SV3-PCS-PLW-10A-1B, dated April 13, 2016 Form NPP-1, Certificate Holders Data Report for Fabricated Nuclear Piping Assemblies, Fabricated and certified by CB&I Laurens, Fabricated for CB&I Stone and Webster, Serial No.

SV3-PCS-PLW-10A-1C, dated April 13, 2016 Form N-5, Certificate Holders Data Report for Installation or Shop Assembly of Nuclear Power Plant Components, Supports, and Appurtenances, Installed and certified by CB&I Laurens, Installed for CB&I Stone and Webster, Serial No. SV3-PCS-PLW-10A-1A (includes Piping Subassembly SV3-PCS-PLW-10A-1B & -1C and Valve BK-560), dated April 13, 2016 CMTR 0YYU5536, ASME SA-312 GR. TP304L, Heat No. F119136, dated January 11, 2012 Liquid Penetrant Examination Report for APP-PCS-PLW-10A, dated January 21, 2016

11 Pipe Spool SV3-PCS-PLW-10F-1 Sketch No. 890700-40-01-00005, Line No. PCS-PL-L007 and L050, Pipe Spool Serial No. SV3-PCS-PLW-10F-1, Heat No. F12A044, Revision 3A Form NPP-1, Certificate Holders Data Report for Fabricated Nuclear Piping Assemblies, Fabricated and certified by CB&I Laurens, Fabricated for CB&I Stone and Webster, Serial No.

SV3-PCS-PLW-10F-1A, dated February 19, 2016 Form NPP-1, Certificate Holders Data Report for Fabricated Nuclear Piping Assemblies, Fabricated and certified by CB&I Laurens, Fabricated for CB&I Stone and Webster, Serial No.

SV3-PCS-PLW-10F-1B, dated February 19, 2016 Form N-5, Certificate Holders Data Report for Installation or Shop Assembly of Nuclear Power Plant Components, Supports, and Appurtenances, Installed and certified by CB&I Laurens, Installed for CB&I Stone and Webster, Serial No. SV3-PCS-PLW-10F-1 (includes Piping Subassembly SV3-PCS-PLW-10F-1A & -1B and Valve SF1107-0025), dated February 19, 2016 CMTR 0YYU5539R1, ASME SA-312 GR. TP304L, Heat No. F119136, dated December 9, 2011 Liquid Penetrant Examination Report for APP-PCS-PLW-10F, dated January 21, 2016 Pipe Spool SV3-PCS-PLW-10J-1A Sketch No. 890700-40-01-00007, Line No. PCS-PL-L048, Pipe Spool Serial No. SV3-PCS-PLW-10J-1B, Heat No. F119139, Revision 1A Form NPP-1, Certificate Holders Data Report for Fabricated Nuclear Piping Assemblies, Fabricated and certified by CB&I Laurens, Fabricated for CB&I Stone and Webster, Serial No.

SV3-PCS-PLW-10J-1B, dated January 28, 2016 Form N-5, Certificate Holders Data Report for Installation or Shop Assembly of Nuclear Power Plant Components, Supports, and Appurtenances, Installed and certified by CB&I Laurens, Installed for CB&I Stone and Webster, Serial No. SV3-PCS-PLW-10J-1A (includes Piping Subassembly SV3-PCS-PLW-10J-1B and Valve BK-489), dated January 28, 2016 CMTR 0YYU5584, ASME SA-312 GR. TP304L, Heat No. F119139, April 9, 2012 Liquid Penetrant Examination Report for APP-PCS-PLW-10J, dated January 12, 2015 Section 1A08 APP-MT01-Z0-100, Design Specification for the AP1000 Core Makeup Tank for System PXS, Revision 10 APP-MT01-VHM-001, AP1000 Core Makeup Tank Technical Manual: Instructions for Receipt Inspection, Storage and Assembly, Revision 0 APP-MT01-VNM-001, AP1000 Core Makeup Tank Technical Manual: Instructions for Operation and Maintenance, Revision 0 SV3-MT01-MHH-005, Rigging Plan, Lifting and Installing Unit 3 Core Make-up Tanks, Revision 0

Section 1A09 Drawings and Procedures Drawing APP-PXS-PLW-022, "Passive Core Cooling System Containment Building Room 11207 Common Injection Header To DVI-B", Revision 3 Drawing APP-PXS-PLW-025, "Passive Core Cooling System Containment Building Room 11204/11207 DVI-B To Reactor Vessel", Revision 5 CB&I Inspection Plan F-S562-006, "Pipe Welding/Brazing ASME B31.3, Power Piping-Visual Weld Inspection (Condenser, Internal Pipe Welds)," Revision 2, Change 0, dated August 17,2015

12 MISTRAS procedure 100-QC-005.2, "Qualification and Certification of Nondestructive Test Personnel," Revision 4.1 MISTRAS PT procedure 100-PT-301, "Liquid Penetrant Examination in Accordance with ASME Section V, Article 6", Revision 12 MISTRAS RT procedure 521-RT-302, "Radiographic Examination Using Computed Radiography In Accordance with ASME Section V, Article 2, Revision 0, dated January 13, 2017 Welding Procedure Specification WPS1-8.8T01, "Manual and Machine GTAW of P-No. 8 to P-No. 8, ASME III All Subsections & Non-ASME III", Revision 10 Weld and NDE Records Weld Record for field weld SV3-PXS-PLW-025-1 on work package SV3-PXS-POW-ME3238, connecting a NPS 8 SCH. S160 pipe of material ASME SA312 Gr. Type 316LN, traceable Serial No. SV3-PXS-PLW-025-1 with 90 LR Elbow NPS 8 SCH S-160, of material ASME SA403 Gr. WP316LN, traceable to serial No. SV3-PXS-PLW-022-2 MISTRAS Computer Radiography Examination Report No. V-18-RT-302-0414, of SV3-PXS-PLW-025-1, dated August 13, 2018 MISTRAS NDE Report Liquid Penetrant Examination Report No. V-18-PT-301-2863, of SV3-PXS-PLW-025-1, dated August 16, 2018 Material Test Records Certificate of Compliance 4931885 dated November 28, 2011, for weld wire ES-ZBER 3/32 x 18-inch Lincoln ER316/316L ASME SFA 5.9, Lot No. 1030C CMTR 7341122 for weld wire ES-ZBER 1/8 x 18-inch Lincoln ER316/316L ASME SFA 5.01, Lot No. 1243V, dated August 31, 2005 Magnaflux Certification for Spotcheck Cleaner, SKC-S, Batch No. 18A23K, dated February 6, 2018 Magnaflux Certification for Spotcheck Developer, SKD-S2, Batch No. 17H08K, dated August 16, 2017 Magnaflux Certification for Spotcheck Penetrant, SKL-SP2, Lot No. 14C08K, dated April 4, 2014 Measuring and Test Equipment Records Certificate of Calibration No. 2334906, dated May 4, 2018, for Magnaflux White Light Meter Serial No. 110703174 calibrated May 11, 2018 MISTRAS Flashlight Verification Log for White Maglite Model Serial No. FL7 performed on August 9, 2018 WECTEC Calibration Checklist No. V-AP-0186-2, for Digital Fluke Thermometer ID No. V-AP-0186, calibrated on August 17, 2017 WECTEC Calibration Checklist No. V-AP-0196-2, for Digital Fluke Thermometer ID No. V-AP-0196, calibrated on October 10, 2017 WECTEC Calibration Report No. V-AE-0109-2, for oxygen analyzer ID No. V-AE-0109-2 calibrated on December 22, 2017 Qualification Records S&W Record of Welder Performance Qualification Test 1SS-02, dated June 19, 2018, MISTRAS NDT Certification Record Certification No. 17213 Level II PT, qualified on December 3, 2015 (due December 2, 2018)

MISTRAS Visual Acuity Record dated August 14, 2018 (due August 14, 2019)

MISTRAS NDT Certification Record Certification No. 21542 Level II Computed Radiography, qualified on August 28, 2017 (due July 20, 2020)

MISTRAS Visual Acuity Record dated November 8, 2017 (due November 8, 2018)

13 Section 1A10 SV3-ME02-Z0-101, Design Specification for AP1000 Passive Residual Heat Removal Heat Exchanger for System PXS, Revision 13 SV3-ME02-Z0M-101, AP1000 PRHR HX Standard Technical Manual, Revision 2 SV3-ME02-MHH-003, Rigging Plan - Upending and Installing Unit 3 PRHR Heat Exchanger, Revision 0 Section 1A11 Construction Isometric Drawing SV3-PXS-PLW-042-R0, Passive Core Cooling System Containment Building Room 11300 PRHR Return Line to SG01, Revision 0 Stone & Webster Welding Data Sheet (WDS) SV3-PXS-PLW-042-13 from Work Package SV3-PXS-P0W-800001, 4/20/18 Stone & Webster Welding Data Sheet (WDS) SV3-PXS-PLW-042-13-WR, 7/10/18 Section 1A12 26139-000-4MP-T81C-N3201, "Construction Survey," Revision 0 SV3-PXS-MEK-891997, "As-Built Elevation Comparison of PRHR Heat Exchanger Upper Channel Head Centerline to RCS Hot Leg Centerline," Revision 1 SV3-ME02-V2-001-R0, "AP1000 Passive Residual Heat Removal Heat Exchanger Assembly Drawing," Revision 3 SV3-RCS-M6K-892061, "Vogtle Unit 3 RCS Hot and Cold Leg As-Built Centerline Elevations,"

Revision 2 SV0-GQ-FEX-001, "Training Matrix Guidance," Revision 10 NCSP03-06, "Personnel Training and Qualification," Revision 05.03 NCSP03-03, "Construction Engineering", Revision 01.04 NCSP03-24, "Field Surveying", Revision 05 Section 1A13 SV3-PXS-FSK-800186, "As-Built Hx Outlet Lines Elevation Comparison to PRHR HX Lower Channel Head Top Inside Surface Elevation", Rev. 0 SV3-ME02-V2-001, "AP1000 Passive Residual Heat Removal Heat Exchanger Assembly Drawing", Rev.0 SV3-PXS-M6-002, "Piping and Instrumentation Diagram Passive Core Cooling System", Rev. 7 SV3-PXS-PLW-042, "Passive Core Cooling System Containment Building Room 11200 PRHR Return Line to SG 01", Rev. 1 SV3-PXS-PLW-041, "Passive Core Cooling System Containment Building Room 11200 PRHR Return Line to SG 01", Rev. 2 SV3-RCS-PLW-04A, "Reactor Coolant System Containment Building Rooms 11300/11303 PRHR Return Line to SG 01", Rev. 2 SV3-RCS-PLW-04B, "Reactor Coolant System Containment Building Room 11300 PRHR Return Line to SG 01", Rev. 2 SWR 1041465, Survey of PRHR HX and piping, Dated 8-29-18 SV3-ME02-V2-002, "Passive Residual Heat Removal heat exchanger Header Assembly", Rev.

0 Qualifications for ITAAC field Engineer SV0-GQ-FEX-001, "Training Matrix Guidance," Revision 10 SV3-PL02-Z0-001, "Piping Class Sheets and Standards Details", Rev. 6

14 Section 1A14 SV3-PXS-MTK-892047, "CMTs Bottom Inside Tank Surface Comparison to DVI Nozzle Centerline Elevation", Rev. 2 SV3-PXS-MTK-892046, "As-Built Field Measurement of PXS-MT-02A", Rev. 0 SV3-PXS-MTK-892045, "As-Built Field Measurement of PXS-MT-02B", Rev. 0 W3-DWF-00-10-050, "AP1000 Core Makeup Tank," Rev. 012 SV3-RCS-P6K-887954, "Unit 3 Reactor Vessel Direct Injection Nozzles Elevations", Rev. 0 SV3-MT01-VQQ-001, "SV3 CMT#1 Quality Release & Certificate of Conformance", Rev. 4 2.2.03.08c.v.01-U3-PRF-Rev 0 CMT Inside Bottom EL vs DVI Nozzle Centerline EL, Vogtle Unit 3 Principal Closure Document Review, dated 9/20/18 Vogtle Electric Generating Plant, Units 3 and 4 UFSAR, Section 2, System Based Design Descriptions and ITAAC, Rev. 6 SWR-1040605, Survey of Core Makeup Tank manway elevation, dated 9/7/18 Section 1A15 SV3-DB01-V8M-001-R0, "AP1000 Class 1E 250 VDC Battery Assembly Drawings: Instruction for Assembling 1E Racks", Revision 0 SV3-1211-CE-001-R3, "Auxiliary Building Area 1 Battery Racks Embedment Plate Locations Room 12104 Plan at El 66'6" ", Revision 7 SV3-1211-CE-002-R3, "Auxiliary Building Area 1 Battery Racks Embedment Plate Locations Room 12105 Plan at EL 66'6" ", Revision 7 SV3-1212-CE-002-R3, "Auxiliary Building Area 2 Battery Racks Embedment Plate Locations Room 12102 Plan at EL 66'6" ", Revision 7 SV3-1212-CE-001-R3, "Auxiliary Building Area 2 Battery Racks Embedment Plate Locations Room 12101 Plan at EL 66'6" ", Revision 7 SV3-1212-CE-003-R3, "Auxiliary Building Area 2 Battery Racks Embedment Plate Locations Room 12103 Plan at EL 66'6" ", Revision 7 SV3-1212-CE-002-R3, "Auxiliary Building Area 2 Battery Racks Embedment Plate Locations Room 12102 Plan at EL 66'6" ", Revision 7 SV3-1221-CE-001-R3, "Auxiliary Building Area 1 Battery Racks Embedment Plate Locations Room 12204 Plan at El 82'6" ", Revision 3 Section 1A16 Work Packages SV3-1140-SPW-800000 SV3-1140-SPW-800002 SV3-1140-SPW-800003 Design Specifications APP-SS01-Z0-001, Shop Fabrication of Structural Steel Safety Class C, Seismic Category I, Rev. 5 SV3-SS01-Z0-002, Erection of Structural steel, Safety Class C, Seismic Category I, Rev. 4 Drawings SV3-1140-SPK-891744, SPL18 Sequence 3 Connections, Sheet 1 of 2, Rev. 0 SV3-1140-SPK-891744, SPL18 Sequence 3 Connections, Sheet 2 of 2, Rev. 0 SV3-1140-SPK-870553, SPL18 Installation Sequence 3 Weld Map, Sheet 1 of 6, Rev. 3 SV3-1140-SPK-870553, SPL18 Installation Sequence 3 Weld Map, Sheet 5 of 6, Rev. 3 SV3-1140-SS-001, Containment SPL 18 Grating Floor Maintenance Floor Mezzanine Room (11400) Global Plan View, Rev. 2

15 SV3-1140-SS-006, Containment SPL 18 Grating Floor Plan and ISO View SPL 18_02, Rev. 1 Engineering & Design Coordination Report SV0-1100-GEF-000037, Supplemental Specification for Implementing DuraSquirt DTI's, Rev.0 Weld Data Sheets (WDS) 870553-069 870553-071 Weld Procedure Specifications WPS2-1.1F01, FCAW of Carbon and Low Alloy Steels, AWS D1.1 2000 Groups I and II materials, Rev. 3 WPS2-1.1M01, GMAW of Carbon and Low Alloy Steels, AWS D1.1 2000 Groups I and II materials, Rev. 2 WPS2-1.1S01, SMAW of Carbon and Low Alloy Steels, AWS D1.1 2000 Groups I and II materials, Rev. 4 Procedures NCSP 03-40, Structural Steel Erection, Rev. 04.00 26139-000-4MP-T81C-N3221, Structural Steel Erection, Rev. 1 26139-000-4MP-T040-S0021, General Welding Standard GWS-Structural (2000), Rev. 2 Commercial Grade Dedication Document 132175-SS01.00-404-012-00203 Inspection Records 26139-SV3-IR-SS-00033A, Date: 8/29/2018 Calibration Records V-4AM-0011-3, Tension Tester High Strength Bolting, Date: 05/29/2018 Pre-Installation Qualification of Fastener Assemblies Records Direct Tension Indicators (DTI's)

Bolts: ASTM A490 (Diameter & Length), Lot No. 40802 Nuts: ASTM A563, (Diameter) ", Lot No. 17810-497463 Washers: F436, Lot No. 201253 DuraSquirt Washers DTI's: ASTM F959, (Diameter) ", Lot No. A55 Turn of the Nut Method Bolts: ASTM A490, (Diameter & Length) 1 1/8" x 4 ", Lot No. 40312 Nuts: ASTM A563, (Diameter) 1 1/8", Lot No. 21215-155498 Washers: ASTM F436, 1 1/8" (Diameter) 1 1/8", Lot No. 301737 Section 1A17 Design Specifications APP-SS01-Z0-001, "Shop Fabrication of Structural Steel, Westinghouse Safety Class C, Seismic Category I," Rev. 5 APP-1208-Z0-001, "Specification for the Fabrication and Field Erection of the SC Panels and the Conical Roof Steel Structure for the AP 1000 Shield Building," Rev. 2

16 APP-CR01-Z0-010, "Specification for Supply and Installation of Mechanical Splices for Reinforcing Steel," Rev. 8 Drawings SV3-1208-SC-100, Shield Building Steel Wall Panels EL. 100'-0" to EL. 248'-6" General Notes, Rev. 3 SV3-1208-SC-904, Shield Building Steel Wall Panels EL. 100'-0" to EL. 248'-6" Typical Details (Sheet 4), Rev. 2 SV3-1208-SC-231, Shield Building Steel Wall Panels EL. 100'-0" to EL. 248'-6" Connection Panel Group 23, Rev. 3 SV3-1208-SC-232, Shield Building Steel Wall Panels EL. 100'-0" to EL. 248'-6" Connection Panel Group 23 Details 1 Rev. 2 SV3-1208-SC-907, Shield Building Steel Wall Panels EL. 100'-0" to EL. 248 -6" Typical Details (Sheet 7), Rev. 2 SV3-1208-SC-961, Shield Building Steel Wall Panels EL. 100'-0" to EL. 248'-6" Connection Panel Details 1, Rev. 0 Storage Requisition Report SR No. 132175-SRR-18-05612, Date: 28/6/2018 Purchase Order J132175-J400A-00, Rev. 85 Inspection Records IR No. 26139-SV3-IR-SS-00038, "Structural Steel Inspection Record," Date: 7/20/2018 ID No. SV3-1208-CRW-800004-001, "Verification of Installation of Nuts & Washers for Shield Wall Panel 01C," Date: 7/20/2018 Section 1A18 Specifications Specification SV3-CC01-Z0-026, Safety Related Mixing and Delivering Concrete, Revision 7 Specification SV3-CC01-Z0-027, Safety Related Concrete Testing Services, Revision 6 Specification SV3-CC01-Z0-031, Safety Related Placing Concrete and Reinforcing Steel, Rev.

8.

Quality Control Manual PNQCM, Project Nuclear Quality Control Manual, Rev. 0.

Procedure APP-GW-GAP-428, Nonconformance and Disposition Report, Rev. 15 Work Package SV3-1208-CCW-800004 Concrete Pour Card Concrete Placement/Order Pour Card, Pour Number 4133, "U3 Shield Wall RC12 Placement from Elev. 139'4" to 149'6"," 6/29/18

17 Batch Tickets 76442 76444 76445 76446 76447 76448 76449 76450 76451 76452 76453 76454 76455 76456 Inspection Records 26139-SV3-IR-C0-00099, Concrete Pre-Placement Inspection Record, Date: 6/28/18 26139-SV3-IR-C0-00100, Construction Placement Inspection Record, Date: 7/17/18 Condition Reports 50000888, Shield Wall Placement RC-12, Post Placement Condition, Date: 7/12/18 50000001, 139-2 Cylindrical Wall RC-12, Rebar Fabrication & Installation, Date: 7/18/18 50000002, 139 Cylindrical Wall RC-12, Rebar Fabrication & Installation, Date: 7/18/18 70000007, 139 Cylindrical Wall RC-12, Rebar Fabrication & Installation, date: 8/1/18 Nonconformance & Disposition Reports (N&Ds)

SV3-CC01-GNR-000506, Shield Building Azimuth Man Door Honeycomb and Voids, Rev. 0 SV3-CC01-GNR-000501, 139 Cylindrical Wall RC-12, Rebar Fabrication & Installation, Rev.

0 Calibration Records Break Bearing Surface 29130, due 9/1/18 Micrometer/Caliper 4073, due 10/20/18 Break Bearing Surface 542, due 10/20/18 Pad Cap Retainer 4323, due 10/26/18 Pad Cap Retainer 4322, due 10/26/18 Straight Edge MACTEC LID #3255, due 10/28/18 Forney Test Pilot SN-11064, due 2/6/19 Compression Testing Machine V-T-0002A, due 8/1/19 Concrete Test Records AMEC Concrete / Grout Card Set ID 2018VEGP7839, 7/27/18 AMEC Concrete / Grout Card Set ID 2018VEGP7840, 7/27/18 Concrete/Grout Delivery Ticket #76448, Pour #4133, 06/29/2018 Concrete/Grout Delivery Ticket #76456, Pour #4133, 06/29/2018 AMEC Conventional Concrete Testing Log, Pour #4133, 06/29/2018 Miscellaneous Concrete Specimen Initial Curing Log, Pour #4133, 7/27/17 Curing Box Logs, Pour #4133, 6/29/18 to 6/30/18

18 Section 1A19 WEC APP-1208-Z0-001, Specification for the Fabrication and Field Erection of the SC Panels and the Conical Roof Steel Structure for the AP1000 Shield Building, Revision 2 CB&I Weld Traveler U3-01A/01B Vertical Inside/Outside Seam for Panels 01A to 01B, 11/13/17 CB&I Vertical Seam Peaking Dimensional Checks, Dimensional Inspection Report U3-020, Traveler U3 01A/01B I/O Vert., Seq. No. 11, by MF, 12-9-17 CB&I Report of Visual Examination, Report No. U3-040, Traveler U3 01A/01B Vert I/O, Seq. No.

5A, 5B, Signed by MF Level II, 12/9/17 CB&I Magnetic Particle Examination, Report No. U3-047, Traveler U3 01A/01B Vert I/O, Seq.

No. 5E, Inside and Outside Temporary Attachment (TA), by MF Level II, 12-9-2017 CB&I Magnetic Particle Examination, Report No. U3-053, Traveler U3 01A/01B Vert I/O, Seq.

No. 9, Inside and Outside Backup Bar (B.U.B.) removal areas I/O, by MF Level II, 12-9-2017 CB&I AWS Report of Ultrasonic Testing of Welds, Report No. U3-056, UT on 01A/01B Vert Outside, by RTC Level II, 12/13/2017 CB&I AWS Report of Ultrasonic Testing of Welds, Report No. U3-059, UT on 01A/01B Vert Inside, by NL Level II, 12/12/2017 CB&I Weld Traveler U3-01C/01D Vertical Inside/Outside Seam for Panels 01C to 01D, 5/8/18 CB&I Vertical Seam Peaking Dimensional Checks, Dimensional Inspection Report D0064, Traveler U3 01C/01D Vert. I/O, Seq. No. 26, by AJG, 6-1-18 CB&I Magnetic Particle Examination, Report No. 231122-003-IN-RP-M0242, Traveler U3 01C/01D Vert I/O, Seq. No. 14 & 24, MT of Vert TA and BUB Removal Areas, by MF Level II, 5/31/2018 CB&I AWS Report of Ultrasonic Testing of Welds, Report No. 231122-003-IN-RP-U0242, UT on 01C/01D Vert Inside, by NL Level II, 06/01/2018 CB&I AWS Report of Ultrasonic Testing of Welds, Report No. 231122-003-IN-RP-U0243, UT on 01C/01D Vert Outside, by NL Level II, 06/01/2018 CB&I WPS 181816-000-WS-SP-E8018, Rev. 2, 03/27/2018 (with supporting PQR 13408 with Cv at -70F, June 3, 2015)

CB&I WPS 181816-000-WS-SP-E71T1, Rev. 1, 04/23/2018 (with supporting PQR 13404 with Cv at -70F, February 3, 2015)

CB&I Services Welder Performance Qualification (WPQ) for welders DGC7650 (4), DRP0601 (2), JAL0807 (2), JAW6216 (4), JBW2054 (1), and TRW7177 (2)

CB&I Master Welder Qualification List - Vogtle Unit 3 and 4, ASME Section IX, 7/3/2018 CB&I Master Welder Qualification List - Vogtle Units 3 and 4, AWS D1.1, 7/3/2018 Lincoln Electric CMTR 9108375 ES-RBCF for 1/8" dia. Excalibur 8018-C1 MR 50EO, Lot-No.

1332R for SMAW with Cv at -70F, 17 Mar. 2018 Lincoln Electric CMTR 6339162 ES-RBGA for 0.045" dia. Outershield 71M 25SP (VFB), Lot-No.

1186B for FCAW with Cv at -70F, 26 Mar. 2014 Lincoln Electric CMTR 9108375 ES-RBGA for 0.045" dia. Outershield 71M 25SP, Lot-No.

1329B for FCAW with Cv at -70F, 18 Jan. 2018 WEC Nonconformance and Disposition Report (N&D) SV3-1208-GNR-000099, Rev. 0, "SV3 01C to 01D fit-up CBIS 231122-003-QA-NC-0026", 05/22/2018 NCR 231122-003-QA-NC-00026, Hold Tag. 39, Unit 3 Vert Fit-up 01C Panel and 01D Panel, 6/7/18 CB&I Weld Traveler R/T U3-01C/D Tie Bar (231122-003-QA-TRV-01036), 5/29/18 CB&I Magnetic Particle Examination, Report No. 231122-003-IN-RP-M0241, Traveler U3 01C/01D Tie Bar, Seq. No. 7, MT 10% of final weld on a tie bar splice plate, by MF Level II, 6/1/2018

19 Section 1A20 Design Specifications SV3-1208-Z0-001, Specification for the fabrication and erection of the Steel Composite Panels for the AP1000 Shield Building, Rev. 0 Procedures 26139-000-4MP-T81C-N3701, Welding Program, Rev. 0 181816-000-WS-SP-45001, General Welding Procedure Specification for AWS D1.1, AWS D1.4 Qualified WPSs, Rev. 1 CMS-720-03-PR-09654, Preheat/Interpass Temperature for ANSI/AISC N690 Projects, Rev. 0 CMS-720-03-PR-09604, Monitoring Welding Parameters for ANSI/AISC N690 Projects, Rev. 0 181816-000-WS-PR-45054, Ultrasonic Examination of Statically Loaded Nontubular Connections-AWS D1.1 Shield Building Work. Rev. 2D Drawings SV3-1208-SC-101, Shield Building Steel Wall Panels EL. 100-0 to EL. 248-6, Rev. 4 SV3-1208-SC-029, Shield Building Steel Wall Panels EL. 100-0 to EL. 248-6, Rev. 0 SV3-1208-SC-906, Shield Building Steel Wall Panels EL. 100-0 to EL. 248-6, Rev. 5 SV3-1208-SCK-CV6886, Shield Building Unit 3 Weld Details, Sheet 1 of 4, Rev. 2 SV3-1208-SCK-CV6886, Shield Building Unit 3 Weld Details, Sheet 2 of 4, Rev. 2 SV3-1208-SCK-CV6886, Shield Building Unit 3 Weld Details, Sheet 3 of 4, Rev. 2 SV3-1208-SCK-CV6886, Shield Building Unit 3 Weld Details, Sheet 4 of 4, Rev. 2 SV3-1208-SCK-CV8647, Unit 3 Shield Wall Weld Map for Course 7, Rev. 1 Pre-Heat Interpass Monitor Logs 07B-07C Vert I/O, Date: 08/07/18 06/07/01 I/O Horiz, Date: 08/07/18 07F/07G Vert I/O, Date: 08/07/18 07A/07B Vert I/O, Date: 08/07/18 06/07 Horiz I/O, Date: 08/07/18 07B/07C Verti I/O, Date: 08/07/18 Daily Welding Material Distribution Log 07B/07C, Vertical, Outside, Sequence 5A, Date: 08/07/18 07B/07C, Vertical, Inside, Sequence 5B, Date: 08/07/18 07F/01F/06G, Horizontal, Inside, Sequence 3A+3C, Date: 08/07/18 07F/01F/06G, Horizontal, Outside, Sequence 3A+3C, Date: 08/07/18 07A/07B Vertical Inside, Date: 08/06/18 07A/07B Vertical Outside Sequence 5A, Date: 08/06/18 07B/01B/01C, Horizontal, Sequence 3C, Date 08/06/18 Welding Procedure Specification and Supporting Procedure Qualification Records 181816-000-WS-SP-A8018, Shield Wall, Rev. 0B PQR 13411W PQR 13499W PQR 13410W PQR 13500W PQR 13412W PQR 13501W 181816-000-WS-SP-E71T1, Shield Wall, Rev. 0J PQR 13404

20 PQR 13869 PQR 13863 Traveler Document 231122-003QA-TRV-07006, Weld Vertical Seam for Panels U 07A/07B I/O, Date: 7/24/18 231122-003QA-TRV-07041, Weld Horizontal Seam for Panels 07D and 01D/01E, Date: 8/24/18 231122-003-QA-TRV-07041, Weld Horizontal Seams for Panels U3 07D & 01D/01E, Date:

8/22/18 Nondestructive Examination Reports (NDE's) 231122-003-IN-RP-U0283, Ultrasonic Test on Horizontal Weld on Panels 07D and 01D/01E 231122-003-IN-RP-U0287, Ultrasonic Test on Horizontal Weld on Panels 07D and 01D/01E 231122-003-IN-RP-U0288, Ultrasonic Test on Horizontal Weld on Panels 07D and 01D/01E 231122-003-IN-RP-U0293, Ultrasonic Test on Horizontal Weld on Panels 07D/07E and 01E 231122-003-IN-RP-U0295, Ultrasonic Test on Horizontal Weld on Panels 07D/and 01D/01E 231122-003-IN-RP-U0297, Ultrasonic Test on Horizontal Weld on Panels 07C and 01C/01D Engineering and Design Coordination Reports (E&DCR's)

APP-1208-GEF-027, Shield Building Panel Connection Components Corrections &

Clarifications, Rev. 0 APP-1208-GEF-054, Clarification of Weld Detail between 0.75" and 1", Rev. 0 APP-1208-GEF-069, Shield Building Panel Edge Weld Transition between inch and 1 inch plates, Rev. 0 APP-1208-GEF-078, Shield Building Joint Callout Clarification, Rev. 0 APP-1208-GEF-099, Shield Building Q Wall Plate Location Clarification and Panel Weld Clarification, Rev. 0 APP-1208-GEF-123, Shield Building D2L Subsurface Fitting Allowance, Rev. 0 APP-1208-GEF-850037, Panel 27 Bevel @ EL. 106'-6", Rev. 0 Section 1A21 Design Specifications SV3-CC01-Z0-031, Safety Related Placing Concrete and Reinforcing Steel, Rev. 8 SV3-CC01-Z0-026, "Safety Related Mixing and Delivering Concrete," Rev. 7 SV3-CC01-Z0-027, "Safety Related Concrete Testing Services," Rev. 6 Drawings SV3-1242-CR-204, "Auxiliary Building Concrete Outline Area 2 Concrete Reinforcement Floor El. 117-6 Plan", Revision 4 SV3-1200-CE-998-R2, "Standard Headed Embedment Plates G1, G2, G3 and Non0standard Plates X1, X2, NSDWA-122 & NSDWA-123", Rev. 2 SV3-1200-CE-999-R0, "Auxiliary Building Non-Standard Embedment Plates 4P-5, 4P-51, DEA1, NSHA-069, NSDWA-119, NSHA-070, NSTB-001/002/003/004, NSHA-070, NSTB-001/002/003/004, NSHA-048, NSHA-049, NSNI &NSN3", Rev. 0, SV3-1200-CE-988-R0, "Standard Headed Anchor Embedment Plates J1, J2, J3, J4", Rev. 0 SV3-1200-CE-992-R1, "Auxiliary Building Non-Standard Embedment plates NSP-05, NSP-06, NSP-07, NSP-09, 4P-8a and 4P-5", Rev. 3 SV3-CE01-CE-001, "Standard Embedment Plates Headed Anchor (HA) Type (Sheet 1)", Rev. 6 SV3-1242-CE-008-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Locations RM 12401 Plan EL 1176 Sheet 3 of 6", Rev. 4

21 SV3-1242-CEX-008-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Index RM 12401 Plan EL 1176 Sheet 3 of 6", Rev. 4 SV3-1242-CE-009-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Locations RM 12401 Plan EL 1176 Sheet 4 of 6", Rev. 3 SV3-1242-CEX-009-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Index RM 12401 Plan EL 1176 Sheet 4 of 6", Rev. 3 SV3-1242-CE-010-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Locations RM 12401 Plan EL 1176 Sheet 5 of 6", Rev. 3 SV3-1242-CEX-010-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Index RM 12401 Plan EL 1176 Sheet 5 of 6", Rev. 3 SV3-1242-CE-011-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Locations RM 12401 Plan EL 1176 Sheet 6 of 6", Rev. 4 SV3-1242-CEX-011-R2, "Auxiliary Building Area 2 Main Control Room Raised Floor Support Embed Plate Index RM 12401 Plan EL 1176 Sheet6 of 6", Rev. 4 Engineering and Design Coordination Reports (E&DCRs)

APP-1200-GEF-909, Changes to Finned Floor Bottom Dowel Reinforcement, Rev. 0 SV3-CE01-GEF-000091, "Sub-Divide of MCR Floor Embed Plates", Rev. 0 SV0-CC01-GEF-000451, Air Entrainment on Concrete Mixes for Indoor Members, Rev. 0 SV0-CC01-GEF-000399, ASTM C138 Acceptance Criteria, Rev. 0 Calculation CALC-VMD-026, Mix M-Test Results of Laboratory Mix Trials, Rev. 1 Concrete Pour Card 4246, U3 North Auxiliary Building Slab Floor at EL. 117'-6", Date 8/17/18 Batch Tickets 76824 76831 76840 Section 1A22 Specifications Specification SV3-CC01-Z0-026, Safety Related Mixing and Delivering Concrete, Revision 7 Specification SV3-CC01-Z0-027, Safety Related Concrete Testing Services, Revision 6 Specification SV3-CC01-Z0-031, Safety Related Placing Concrete and Reinforcing Steel, Revision 8 Calibration records Break Bearing Surface 29130, due 9/1/18 Micrometer/Caliper 4073, due 10/20/18 Break Bearing Surface 542, due 10/20/18 Pad Cap Retainer 4323, due 10/26/18 Pad Cap Retainer 4322, due 10/26/18 Straight Edge MACTEC LID #3255, due 10/28/18 Forney Test Pilot SN-11064, due 2/6/19 Compression Testing Machine V-T-0002A, due 8/1/19

22 Concrete Test Records AMEC Concrete / Grout Card Set ID 2018SCC0956, 7/27/18 AMEC Concrete / Grout Card Set ID 2018SCC0957, 7/27/18 Concrete/Grout Delivery Ticket #49297, Pour #4106, 06/29/2018 Concrete/Grout Delivery Ticket #49301, Pour #4106, 06/29/2018 AMEC SCC Testing Log, Pour #4106, 06/29/2018 Miscellaneous Concrete Placement/Order Pour Card, Pour Number 4106, "U3 North Auxiliary Building Wall Placement #116 Wall 11 Critical Section elevation 115'6" and 117'6" to 135'3"," 6/29/18 Concrete Specimen Initial Curing Log, Pour #4106 7/27/17 Curing Box Logs, Pour #4106, 6/29/18 to 6/30/18 Work Package SV3-1240-CCW-800000 Section 1A23 Design Specifications SV3-CC01-Z0-031, "Safety Related Placing Concrete and Reinforcing Steel," Rev. 8 SV3-CC01-Z0-026, "Safety Related Mixing and Delivering Concrete," Rev. 7 SV3-CC01-Z0-027, "Safety Related Concrete Testing Services," Rev. 6 Procedure APP-GW-GAP-428, "Non-Conformance and Disposition Report," Rev. 15 Drawings SV3-1200-CR-950, "Aux Building Areas 5 & 6 Concrete Reinforcement Wall 1 Elevation", Rev.

8 SV3-1230-CR-950, "Aux Building Areas 5 & 6 Concrete Reinforcement Wall 1 Elevation", Rev.

6 SV3-1240-CR-950, "Aux Building Areas 5 & 6 Concrete Reinforcement Wall 1 Sections and Details EL. 117'-6"", Rev. 4 SV3-0000-C9-002A, AP1000 General Notes, Rev. 2 SV3-0000-C9-002A, AP1000 Concrete General Notes, Rev. 2 E&DCRs SV3-CR01-GEF-000379,"Hold on Formwork Installation for East Portion of Wall 1 between EL.

117'-6" and EL. 135'-3", Rev. 1 SV0-CR01-GEF-001092,"Reinforcing for Pipe Penetrations, EL. 119'-0", 1 Line Wall, Rev. 0 SV3-CR01-GEF-000448,"Wall # 121 @ 1-Line; Vertical Corner Bar Outside Horizontal Hook Bar at EL. 117'-6"", Rev. 0 SV3-CR01-GEF-001091,"1 Line Wall EL. 127 ft. Corbel Detail Changes", Rev. 0 N&Ds SV3-CR01-GNR-000904, "1 Line Wall d Dimensions above Elevation 100'-0"", Rev. 0 SV3-CR01-GNR-000995, "Wall # 121 @ 1-Line Pipe Penetration/Rebar Conflict", Rev. 0 SV3-CR01-GNR-000920," Wall # 74 @ 1-Line: Closed-ties East of Pipe Penetrations above Elevation 117'-6"", Rev. 0 Pour Card 4199, U3 South Aux Building Wall Placement # 121 and # 122 (1-Line) up to 127-0

23 Batch Tickets 49618, Date: 08/02/2018 49625, Date: 08/02/2018 Section 1A24 Specifications SV3-CC01-Z0-031, "Safety Related Placing Concrete and Reinforcing Steel," Rev. 8 Procedure APP-GE-GAP-420, "Engineering and Design Coordination Reports," Rev. 12 Drawings SV3-0000-C9-001, "AP1000 Concrete General Notes," Rev. 8 SV3-1230-CR-344, "Aux Building Area 4 Concrete Reinforcement Floor EL. 105'-0" & 107'-2" Plan View," Rev. 1 SV3-1230-CR-393, "Aux Building Areas 4 & 5 Concrete Reinforcement Floor EL. 100'-0", 105'-

0" & 107'-2" Details," Rev. 6 SV3-1230-CR-100, "Aux Building Concrete Reinforcement Slab joint Rebar to Connect with Shield Building EL. 100'-0"," Rev. 2 SV3-1234-CE-001, "Aux Building Area 4, 2 HR Fire rated Metal Studded Wall Anchor Bolt Locations-Room 12351 Plan @ EL. 107'-2"," Rev. 0 E&DCR's APP-CR01-GEF-150,"Slab 12351 Reinforcement Spacing Around Large Floor Penetrations EL.

107'-2", Rev. 0 APP-1208-GEF-432,"Radial Dowel T-head Clarification for Elevations 100', 105', and 107-2"",

Rev.0 SV0-CR01-GEF-001141,"ESR 50001395 AB A4 Room 12351 Removal of CJ at Concrete Stairs SP-22", Rev. 0 SV0-1200-GEF-001,"Concrete Slab Top & Shear Reinforcement Details for Floor Drain Interferences", Rev. 0 APP-1230-GEF-850011,"Dedicated Conduit Penetrations for Radiation Monitor RMS-JE-RY021", Rev.0 SV3-CR01-GEF-000432,"# 9 U-bars Around Floor Opening, EL.107'-2" Room 12351", Rev. 0 SV3-CR01-GEF-000431,"#5 90 Degree Hook and Shear Ties Installation-Room 12351", Rev. 0 Section 1A25 Design Specification SV3-CC01-Z0-031, Safety Related Placing Concrete and Reinforcing Steel, Rev. 8 Design Drawings SV3-1200-CR-953, Aux Building Areas 5 & 6 Concrete Reinforcement Wall 4 Elevation, Rev.13 SV3-1240-CR-953, Aux Building Areas 5 & 6 Concrete Reinforcement Wall 4 Sections and Details, Rev.4 SV3-1200-CR-991, Auxiliary Building Concrete Reinforcement Typical Opening Detail, Rev. 5 SV3-0000-C9-001, AP1000 Concrete General Notes, Rev. 8 SV3-0000-C9-002A, AP1000 Concrete General Notes, Rev. 2 Non Conformance and Disposition Reports SV3-CR01-GNR-000924, I-line at 4-line; rebar congestion at 4-line hook bars, Rev. 0

24 SV3-CR01-GNR-000958, Added Bars Over 4-line Wall Opening, Rev. 0 Engineering Design and Coordination Report SV0-CR01-GEF-001068, 4-line Wall Opening Reinforcement Requirement, Rev. 0 Section 1A26 This input is security related. See non-public report 05200025/2018412 for details.

Section 1A27 SV0-RCS-M0P-800315, GQ P 9.7, "Solvent Removable Liquid Penetrant Examination and Acceptance Standards for Welds, Base Materials, and Cladding", Revision 19 ASME Section III, Subsection NB, "Class 1 Components", 1998 with 2000 Addenda Traveler 913384-011, "Install RCL Piping FW SV4-RCS-PL01-FW-BCL05", Rev. 0 Section 1A28 Design Specification, Technical Manual, Rigging Plan and Drawings Westinghouse Design Specification APP-MB01-Z0-101, "Design Specification for AP1000 Steam Generator for RCS," Revision 12 Westinghouse Technical Manual, TM 1440-C394, Volume 1, Revision 2, Document No. APP-MB01-VHM-001, "AP1000 Steam Generator Instructions for Receipt Inspection, Storage and Assembly," Revision 1 Bechtel Rigging Plan No. SV4-MB01-MHH-003, "Upending and Installation of Unit 4 Steam Generators MB-01 & MB-02," Revision 0 Drawing APP-MB01-V2-701, "AP1000 Steam Generator Installation Outline," Revision 1 Field Sketch Drawing 26139-SV4-FSK-R-000003, "Unit 4 Steam Generator Vertical Lift Installation Orientation," Revision 0 Drawing APP-VH01-V2-105, "Steam Generator Lift Assembly Trunnion and Temporary Support Linkage," Revision 2 E&DCR and Deviation Notices Westinghouse E&DCR No. APP-VH01-GEF-105, "EDCR to Change Minimum Thread Length Requirement on SG Upender Adaptor Plate Screws (Socket Head Cap)," Revision 0 APP-VH01-GEF-159, "Modifications to the SG Upender Skid Bolting and SG Clevis/Adapter Plates Bolting Sequence," Revision 0 APP-VH01-GEF-161, "Modification to SG Upender Installation Drawings," Revision 0 SV4-VH01-GNR-000002, "SV4 SG Up-ender Pin Re-use Inspection," Revision 0, disposition "Use-As-Is" dated of fluorescent wet magnetic particle examination report V-18-MT-302-3987 by MISTRAS SV0-MB01-GNR-000001, "MB01 Steam Generator Storage Condition," Revision 0 Bechtel Deviation No. SV4-MB01-MHF-001 for Rigging Plan SV4-MB01-MHH-003, Revision 0, Deviation No. 2 for MB-02 (East) Link Plates (2 each) signed by QC inspector on August 23, 2018 Bechtel Deviation No. SV4-MB01-MHF-002, dated August 23, 2018, for Rigging Plan SV4-MB01-MHH-003, Revision 0, for addition of 3 25'x9'x5' LAMPSON Crane mats under the upending frame changes the loading of the transporter and center of gravity offset necessary to equalize pressures, effecting page 5 of rigging plan with revised LAMPSON Hook Load calculation

25 NDE and M&TE Records MISTRAS Magnetic Particle Examination Report No. V-18-MT-302-3987, performed on Clevis Pin that was rejected on August 7, 2018, due to 4 linear indications found from bottom ends ATS Magnetic Particle Examination Report performed on 78 pieces of carbon steel 3-3/8" x 9-1/4" Trunnion Bolts, dated August 7, 2018 LAMPSON Trimble GS82 load scale and anemometer gage calibrated by Trimble Lifting Solutions Service on July 31, 2018 LAMPSON Lattice Boom Crane Inspection Report No. 037-18 performed by B&M Equipment Repair and Certification, Inc., dated July 10, 2018 LAMPSON Hoist Daily Inspection Log for Hoist S/N H547/H546 performed on August 24, 2018 LAMPSON Annual Assembly Inspection Report for Transi-Lift Heavy Lift Mobile Crane Model LTL 2600 dated July 11, 2018 Certificate of Calibration and Traceability No. COL-11067-299457-1, 299458-1, 299459-1, and COL-11067-299456-1 for LAMPSON Transporter pressure gauge ID Nos. 106451, 106452, 106453 and 106454, calibrated by J.A. King on August 17, 2018 LAMPSON crane operator certification dated August 31, 2014 due August 31, 2019 LOCTITE N7000 Ant-seize lubricant tag No. NLOC-51270, expiration date May 2022 STEP BY STEP LIFT NARRATIVE Bechtel document No. 26139-000-4MP-T81C-N1903, "Construction Rigging Work Operation Appendix A, "Shackle Inspection Form," for Wide Body Shackle S/Ns PL 7829KN #46, GN901463-2, PL6524KN # 38, #39, #40 and #41 dated August 23, 2018 Pre-Lift Rigging Steps for Trunnion Links "Step by Step Lift Narrative," signed on August 24, 2018 WECTEC Document SV0-VH01-MHH-011, "SG Upending Clevis & Manway Lift Trunnion Installation Plan," Revision 0 WECTEC Rigging Plan No. SV0-VH01-MHH-011, "Torque Data Sheet for SG Upending Clevis

& Manway Lift Trunnion Installation," dated August 22, 2018 Step by Step Lift Narrative Pre-requisite Steps for Upending and Installation Unit 4 Steam Generator MB-02 signed on August 23, 2018 Construction Rigging Work Operations No. 26139-000-4MP-T81C-N1903, "Pre-Lift Safety Checklist w/Roster" signed on August 24, 2018 Pre-Transport Safety Checklist w/Roster for Medium and Critical Transport Operations of KAMAG 2406S HS4E (Transporter) signed on August 24, 2018 Step-by-Step Narrative work steps for Upending and Installing Unit 4 Steam Generator MB-02 completed on August 24, 2018 with Step 5 for LAMPSON'S LMIT documented on Deviation No. SV4-MB01-MHF-002 Section 1A29 Drawings and Procedures Drawing No. SV4-RCS-VE-001 PCI Weld Map API-0755, "RCL Piping Weld Map," for Project No. 913384, Revision 0 PCI General Quality Procedure (GQP) 9.6 "Visual Examination of Welds," Revision 18 PCI GQP 9.7, "Solvent Removable Liquid Penetrant Examination and Acceptance Standard for Welds, Base Materials and Cladding (40 to 125F)", Revision 19, PCI GQP 9.7 Procedure Supplement PS-03, "Procedure Supplement," Revision 0, dated April 24, 2018 MISTRAS RT procedure 521-RT-302, "Radiographic Examination Using Computed Radiography In Accordance with ASME Section V, Article 2", Revision 0

26 PCI Welding Procedure Specification No. 8MN-GTAW Revision 7, w/Supplement 8MC-GTAW Revision 18 PCI Procedure Qualification Record (PQR) No. 8 MC-GTAW, "Manual GTAW process for P8-P8 material without Impact Testing," Revision 16 PCI PQR No. 062, "Machine GTAW process, for P8-P8 material," Revision 2 PCI PQR No. 063, "Manual GTAW and Manual SMAW process, for P8-P8 materials," Revision 6

PCI PQR No. 600, "Machine GTAW Process, for P8-P8 materials," Revision 8 PCI PQR No. 864, "Machine GTAW process for P8-P8 materials, without impact testing,"

Revision 2 PCI PQR No. 899, "Machine GTAW process for P8-P8 material without impact testing,"

Revision 4 Welding and NDE Records PCI Weld Process Traveler 913384-003 for field weld No. SV4-RCS-PL01-FW-BHL01 hot leg RCS L001B PCI Weld Process Traveler 913384-004 for field weld No. SV4-RCS-PL01-FW-BCL04 cold leg RCS L002C PCI Weld Process Traveler 913384-005 for field weld No. SV4-RCS-PL01-FW-BHL06 col leg RCS L002D PCI Quality Assurance Traveler 913384-005, "RCL Piping Installation for Vogtle Unit 4" on Field Weld No. SV4-RCS-PL01-FW-BCL06 for RV Inlet Nozzle, dated July 12, 2018 PCI Weld Material Withdrawal Slip No. 913384-003 for FW# SV4-RCS-PL01-FW-BHL01, dated August 3, 2018 PCI Report of Nondestructive Examination Visible, "Solvent Removable Liquid Penetrant Examination Report No. NDE-913384-016 (ID)", dated August 7, 2018 PCI Report of Nondestructive Examination Visible, "Solvent Removable Liquid Penetrant Examination Report No.913384-017 (tack welds)", dated August 7, 2018 PCI Report of Nondestructive Examination Visible, "Solvent Removable Liquid Penetrant Examination Report No.913384-019", dated August 20, 2018 PCI Report of Nondestructive Examination Visible, "Solvent Removable Liquid Penetrant Examination Report No.913384-020", dated August 20, 2018 MISTRAS Computed Radiograph Examination Report No. P-18-RT-302-0037, dated August 7, 2018, for Hot Leg RCS-L001B, SV4-RCS-PL01-FW-BHL01 MISTRAS Computed Radiograph Examination Report No. P-18-RT-302-0038, dated August 7, 2018, for Cold Leg RCS-L002C, SV4-RCS-PL01-FW-BCL04 MISTRAS Computed Radiograph Examination Report No. P-18-RT-302-0039, dated August 7, 2018, for Cold Leg L002D, SV4-RCS-PL01-FW-BCL06 Material Certification Records Lincoln CMTR 6338992 dated March 28, 2014 for 0.035" diameter ER316LN, Heat /Lot No.

1182D, ASME SFA 5.9 Lincoln CMTR 6338965 dated March 28, 2014 for 3/32" diameter x 18" ER316/ER316LN, Heat

/Lot No. 1181M, ASME SFA 5.9 Lincoln CMTR 6338965 dated March 28, 2014 for 1/8" diameter x 18" ER316/ER316LN, Heat

/Lot No. 1181L, ASME SFA 5.9 Certificate of Conformance for Magnaflux SpotCheck developer SKD-S2 Batch No. 16J08K, expires September 2021 Certificate of Conformance for Magnaflux SpotCheck Cleaner SKC-S Aerosol Batch No.

17K13K, expires October 2022

27 Certificate of Conformance for Magnaflux SpotCheck Penetrant SKP Batch No. 16D16K, expires September 2021 M&TE Records PCI Fluke Digital thermometer ID No. PCI QTC-206, calibration due October 6, 2018 PCI White Light Meter ID No. PQC-QLM-37, calibration due September 29, 2018 Qualification Records PCI ASME Welder Maintenance Log for GTAW automatic machine welders, expiration January 16, 2019 PCI ASME Qualified Welder List for Vogtle Unit 4 RCL, Revision 0, dated July 23, 2018 PCI NDE PT Level II Personnel Certification record SAP No. 98853, dated September 22, 2016 PCI NDE VT Level II Personnel Certification record SAP No. 98853, dated September 22, 2016 MISTRAS Level II RT inspector visual acuity record, dated November 8, 2017 MISTRAS NDT Certification Record No. 18800 for RT interpreter Level II inspector certified on July 21, 2016, due June 3, 2019 MISTRAS NDT Certification Record No. 21390 for Computer Radiography Level II inspector certified on July 20, 2017, due July 19, 2020 MISTRAS NDT Certification Record No. 20501 for Computer Radiography Erosion/Corrosion Level III inspector certified on March 6, 2017, due February 2, 2022 Section 1A30 APP-MV01-Z0-101, Design Specification for the AP1000 Reactor Vessel for System: Reactor Cooling System (RCS), Revision 13 APP-MV01-GEM-001, AP1000 Reactor Vessel Instruction Manual, Revision 2 SV4-MV01-MHH-005, Rigging Plan, Upending and Installing Reactor Vessel, Revision 0 Section 1A31 WEC APP-MV50-V8-001, AP1000 Containment Vessel Penetration Installation Specification, Revision 2 WEC APP-GW-P0-008, AP1000 Specification for Field Fabricated Piping and Installation, ASME Section III, Code Classes 1, 2, and 3, and ASME B31.1, Revision 6 WEC Drawing SV4-SFS-MLK-876768, Weld Map for Penetration SV4-SFS-PY-C02(P22),

Revision 0 Construction Isometric Drawing SV4-1100-P0-906-R1, Steel Containment Vessel Mechanical Penetration Details, Revision 1 Construction Isometric Drawing SV4-ML10-V6-010-R1, AP1000 Flued Head Detail Drawing for Penetration P22, Revision 1 Construction Isometric Drawing SV4-MV50-V1-015-R1, AP1000 Containment Vessel Penetrations List, Revision 1 Construction Isometric Drawing SV4-MV50-V1-016-R1, AP1000 Containment Vessel Penetrations Location, Revision 1 Construction Isometric Drawing SV4-MV50-V1-019-R2, AP1000 Containment Vessel Mechanical Penetrations Sleeves Bottom Head, Revision 2 Construction Isometric Drawing SV4-MV50-V2-062-R1, AP1000 Containment Vessel Penetration Sleeve Extensions, Rev. 1 Section 1A32 APP-MV50-V8-001, "AP1000 Containment Vessel Penetration Installation Specification",

Revision 2

28 Weld Data Sheet for Weld Number SV4-RNS-PY-C01-3 (P19 Flued Head to Guard Pipe, Pressure Boundary)

Lincoln Electric Company CMTR No. 8939798, 1/8" x 18", ER309/309L, Heat/Lot 1332L S&W Record of Welder Performance Qualification for Welder ID AT2517, Test No. 1SS-02, dated 6/8/2018 Weld Material Requisition No. 400059 for weld rod ER309L, Heat/Lot 1030A, dated 7/30/2018 Weld Data Sheet for Weld Number SV4-SFS-PY-C02-2 (P22 Flued Head to Penetration Sleeve, Pressure Boundary)

NDE V-18-RT-301-0300, Radiographic Examination Report for SV4-RNS-PY-C01-3, dated 6/19/2018 (P19)

V-18-PT-301-2765, Liquid Penetration Examination Report for SV4-SFS-PY-C02-2, dated 8/2/2018 (P22)

V-18-RT-302-0450, Radiographic Examination Report for SV4-SFS-PY-C02-2, dated 8/22/2018 (P22)

Drawings SV4-SFS-MLK-876768, "Weld Map for Penetration SV4-SFS-PY-C02 (P22)", Revision 0 APP-MV50-V2-062, "AP1000 Containment Vessel Penetration Sleeve Extensions", Revision 1 APP-ML10-V6-010, "AP1000 Flued Head Detail Drawing for Penetration P22", Revision 1 Section 1A33 Drawings APP-KB36-V0-001, Module 1231-KB-36 PCS Pump/Valve Module Drawing Index, Revision 6 APP-KB36-V1-401, Module 1231-KB-36 PCS Pump/Valve Module General Outline Equipment List and Notes, Revision 2 APP-PCS-M6-002, Piping and Instrumentation Diagram Passive Containment Cooling System, Revision 11 APP-PV02-V2-134001, Class 1500 Stainless Steel Manual Operated Y-Globe Valve 2", Seal Welded Bonnet, SW Assembly Drawing PV02 Datasheet 134, Rev. 0 SV0-PV03-V2-111001 - 111004, AP1000 Manually Operated Gate Valve 3" Class 150 Assembly Drawing APP-PV03-Z0D-111, Rev. 0 SV0-PV03-V2-109001 - 109004, AP 1000 Manually Operated Gate Valve 4" Class 150 Assembly Drawing APP-PV03-Z0D-109, Rev. 1 Procedures APP-GW-VH-001, AP1000 Site Receiving Inspection and Storage Requirements for System Materials and Equipment, Rev. 2 26139-000-4MP-T81C-N6201, Field Material Storage Control, Rev. 3 Design Specifications APP-PL02-Z0-102, AP1000 Class 2, 3 Piping and B31.1 Extensions Design Specification, Revision 4 APP-PV02-Z0-001, 2 and Smaller Manually Operated Globe and Check Valves, ASME Boiler and Pressure Vessel Code,Section III, Class, 1, 2 and 3, Revision 13 APP-PV03-Z0-001, Design Specification for 3 and Larger Manually Operated Gate, Stop Check, and Check Valves, ASME Boiler and Pressure Vessel Code,Section III, Class, 1, 2, and 3 for Various Systems, Revision 9

29 Fabrication Specifications APP-GW-VLR-002, Technical Requirements of Stainless Steels, Nickel-Base Alloys, Carbon and Low Alloy Steels, and Welding Materials for the AP1000, Revision 2 APP-GW-VLR-010, AP1000 Supplemental Fabrication and Inspection Requirements, Revision 2

Nonconformance Reports APP-KB36-GNR-850078, dated February 1, 20 17 APP-KB36-GNR-850079, dated February 1, 20 17 APP-KB36-GNR-850128, dated May 4, 20 17 Fabrication Records for QADP SV4-PV02-VQQ-012, Valve PCS-V050 (Serial No. SF1401-008),

Rev. 3 QR-14-1440, Westinghouse Quality Release & Certificates of Conformance, Revision 3 DN-PV02-VG-017, Quality Assurance (QA) Records Data Package Index, Revision 0 Form NPV-1 Certificate Holders Data Report for Nuclear Pumps or Valves, Manufactured and certified by Samshin Limited, Manufactured for Westinghouse Electric Company, Valve Serial No. SF1401-0008, dated May 9, 2014 CMTR-PV02-VG-1402-009, ASME SA182-F304L, Heat No. 1BF-1/1 (Source Material Heat No.

N03280), dated February 25, 2014 CMTR-PV02-VG-1402-008, ASME SA182-F304L, Heat No. 1BE-1/1 (Source Material Heat No.

N02212), dated February 25, 2014 CMTR-PV02-VG-1402-010, ASME SA479-304L, Heat No. 1BJ-1 (Source Material Heat No.

S10122), dated February 25, 2014 HTR-5-0108--003, Heat Treatment Record, Heat Nos. 1BE-1/1 & 1BF-1/1, dated January 8, 2014 14-SSV-P2091, Liquid Penetrant Examination Report, Heat Nos. 1BE-1/1, 1BF-1/1 & 1BJ-1, On Root Pass of Weldments, dated March 4, 2014 14-SSV-P2093, Liquid Penetrant Examination Report, Heat Nos. 1BE-1/1, 1BF-1/1 & 1BJ-1, On Hardfaced Surface & Adjacent Base Material, dated March 13, 2014 PTR-VG4-1404-134-01, Production Test Report (Pressure Test), dated April 9, 2014 Fabrication Records for QADP SV4-PV03-VQQ-017, Valve PCS-V020 (Serial No. BO650), Rev.

3 QR-14-1102, Westinghouse Quality Release & Certificates of Conformance, Revision 3 Certificate of Compliance/Conformance, Westinghouse Electric Co LLC, 3-150-FW (CF3M) S/N BO650, dated March 31, 2014 IMQP 91176-QA-03, Integrated Manufacturing & Quality Plan, Manually Operated Valves Drawing Numbers 09-91176-01 thru 30 & 71, Rev. 7 Form NPV-1 Certificate Holders Data Report for Nuclear Pumps or Valves, Manufactured and certified by Flowserve Corporation, Manufactured for Westinghouse Electric Company, Valve Serial No. BO650, dated March 16, 2014 CMTR No. M1318/SUP-4, ASME SA351 GR CF3M, Heat No. M1318 Serial No. 4, dated March 9, 2011 CMTR No. 4598261 (Larson Internal Heat No. 2634), ASME SA182 Gr F-316SS, Heat Code 251277 (2634), dated June 5, 2012 Exova Test Certificate T21684, Heat 251277, dated August 21, 2012 Liquid Penetrant Examination Report 91176-12 PT of Rough Casting, Heat No M1318, dated November 7, 2012 Weld Repair Data Sheet, 145554, dated April 2, 2013

30 Liquid Penetrant Examination Report of Base Cavities (Reject Ticket 145554), dated April 2, 2013 Weld Process Report 145554, Heat No. 1318-4, dated April 11, 2013 Liquid Penetrant Examination Report PT Hardfacing &1/4 in. Base Metal, dated April 12, 2013 Visual Examination Report 91176-12, Heat No. M1318-4, SA351 GR CF3M, dated October 19, 2012 Flowserve Assembly & Test Data Sheet, 36-Q-1129, Sales Order 91176, dated November 15, 2013 Fabrication Records for QADP SV4-PV03-VQQ-037, Valve PCS-V044 (Serial No. BS252), Rev.

0 QR-16-725, Westinghouse Quality Release & Certificates of Conformance, Revision 0 Certificate of Compliance/Conformance, Westinghouse Electric Co LLC, 4-150-FW (CF3M) CL 3 S/N BS252, dated March 28, 2016 IMQP 91176-109-1, Flowserve Flow Control Division Integrated Manufacturing & Quality Plan, Valve Assembly 4" 150 Flex Wedge Gate (CF3M Austenitic Stainless) ASME Class 3, Rev. 7 Form NPV-1 Certificate Holders Data Report for Nuclear Pumps or Valves, Manufactured and certified by Flowserve Corporation, Manufactured for Westinghouse Electric Company, Valve Serial No. BS252, dated March 28, 2016 CMTR No. M0897/SUP-2, ASME SA351 GR CF3M, Heat No. M0897, dated March 22, 2016 CMTR No. T210067, ASME SA182 Gr F-316SS, Heat Code 159 (G16674), dated June 5, 2012 Exova Test Certificate T210667, Heat G16674, dated May 21, 2012 Liquid Penetrant Examination Report, Heat No M0897, dated February 5, 2013 Visual Examination Report, Heat No. M0897, SA351 GR CF3M, dated January 10, 2013 Weld Process Report 91154, Serial No. M0897 1, dated February 12, 2013 Ultrasonic Examination Report 91176-02, Heat No. 159, May 21, 2013 Liquid Penetrant Examination Report 91176-02, Heat No. 159, dated June 18, 2013 Weld Process Report 91176-02, Heat No. 159, dated June 25, 2013 Flowserve Assembly & Test Data Sheet, 36-Q-1129, dated March 10, 2016 Pipe Spool SV4-PCS-PLW-10X-1A/1B Form N-5 Certificate Holders' Data Report for Installation or Shop Assembly of Nuclear Power Plant Components, Supports, and Appurtenances, Serial No. SV4-PCS-PLW-10X-1A & SV4-PCS-PLW-10X-1B, dated July 1, 2016 Form NPP-1 Certificate Holders' Data Report for Fabricated Nuclear Piping Assemblies, Serial No. SV4-PCS-PLW-10X-1A, dated July 1, 2016 Form NPP-1 Certificate Holders Data Report for Nuclear Pumps or Valves, Serial No. SV4-PCS-PLW-10X-1B, dated July 1, 2016 Sketch No. 891700-40-01-00008, Pipe Spool Serial No SV4-PCS-PLW-10X-1A/1B, Revision 3 CMTR No. 0YYU5536 (mechanical properties), Heat No. F119136, dated January 11, 2012 CMTR No. 2011-9-2 (chemical properties), Heat No. F119136, dated September 30, 2011 Pipe Spool SV4-PCS-PLW-10F-1A/1B Form N-5 Certificate Holders' Data Report for Installation or Shop Assembly of Nuclear Power Plant Components, Supports, and Appurtenances, Serial No. SV4-PCS-PLW-10F-1A & SV4-PCS-PLW-10F-1B, dated April 8, 2016 Form NPP-1 Certificate Holders' Data Report for Fabricated Nuclear Piping Assemblies, Serial No. SV4-PCS-PLW-10F-1A, dated April 8, 2016 Form NPP-1 Certificate Holders Data Report for Nuclear Pumps or Valves, Serial No. SV4-PCS-PLW-10F-1B, dated April 8, 2016 Sketch No. 891700-40-01-00005, Pipe Spool Serial No SV4-PCS-PLW-10F-1A/1B, Revision 3

31 CMTR No. 201431975, Heat No. 539325, dated September 23, 2014 CMTR No. 201431973, Heat No. 539325, dated September 23, 2014 Pipe Spool SV4-PCS-PLW-10E Form N-5 Certificate Holders' Data Report for Installation or Shop Assembly of Nuclear Power Plant Components, Supports, and Appurtenances, Serial No. SV4-PCS-PLW-10E-1A, dated June 10, 2016 Form NPP-1 Certificate Holders' Data Report for Fabricated Nuclear Piping Assemblies, Serial No. SV4-PCS-PLW-10E-1A, dated June 10, 2016 Sketch No. 891800-40-01-00005, Pipe Spool Serial No SV4-PCS-PLW-10F-1A/1B, Revision 3 CMTR No. 0YYU5541R1, Heat No. F12A044 (mechanical properties), dated December 09, 2011 CMTR No. 2011-10-2, Heat No. F12A044 (chemical properties), dated October 11, 2011 Valve Data Sheets APP-PV03-Z0D-109, PV03 Datasheet 109, Rev. 3 APP-PV03-Z0D-111, PV03 Datasheet 111, Rev. 2 APP-PV02-Z0D-134, PV02 Datasheet 134, Rev. 3 Purchase Orders Purchase Order 132176-G230.04 (01/10/18)

Purchase Order 132175-G230.04 (08/15/17)

Receipt Inspection Records Material Receiving Instruction (MRI) 26139-SV4-MRI-18-00163-01, Unit 4 PCS Pump/Valve Module 1231-KB-36, Rev. 0 Q445-18-10069, Receipt Inspection - Non ASME, 1 (1/6/18)

Q445-18-109447, Receipt Inspection: WECTEC Procured ASME III Items, (4/30/18)

CB&I Laurens Valve Installation Weld Records Shop Travelers for Sketch numbers: 891700-40-01-00005, 891700-40-01-00008, 891800 01-00005 Weld Filler Metal CMTRs for heat numbers: CF0140 (1/30/15), CT9686 (6/20/12), AT9460 (3/28/12), CT9742 (11/16/12)

Welding Procedure AP1000803 Revisions 7 and 8 Welding Procedure Qualification records: PRN 070 (6/15/1990), PRN 072 (4/14/1993), PRN 076 (12/11/1991)

Welder Performance Qualification Records for welder IDs: B8 (2/2/15) and B1 (10/6/11)

Liquid Penetrant Test Reports for sketch numbers: 891700-40-01-00005 (1/11/16), 891700 01-00008 (6/15/16), 891800-40-01-00005 (4/22/16)

Aecon Pipe Weld Records Drawings: SV4-KB36-PCS-PLW-03 Rev. 0 and Rev. 1 Weld Data Sheets: SV4-KB36-PCS-PLW-03-Y36-W61 Rev. 0, SV4-KB36-PCS-PLW-03-Y36-W54 Rev. 0 CMTRs for weld filler metal heat numbers: 1290S (9/30/16), 1254K (8/11/15)

Welding Procedure: 88-200-N28, Rev. 2 Welding Procedure Qualification Records: 88-20-715 (3/11/15), 88-200-712 (1/6/15)

Welder Qualification Records for welder IDs: 197 (8/17/16), 155 (8/11/16)

PT reports: PT-Y36-014 (9/29/17), PT-Y36-014 (9/29/17)

VT Reports: VT-Y36-056 (7/24/17), VT-Y36-060 (7/26/17), VT-Y36-224 (9/29/17)

32 Section 1A34 V-18-RT-302-0267, "Computed Radiography Examination Report, field weld SV4-PXS-PLW-020-3, 5/31/2018 V-18-RT-302-0281, "Computed Radiography Examination Report, field weld SV4-PXS-PLW-01V-8, 6/05/2018 V-18-RT-302-0330, "Computed Radiography Examination Report, field weld SV4-PXS-PLW-01V-10, 7/10/2018 WEC isometric drawing APP-PXS-PLW-020, "Passive Core Cooling System Containment Building Room 11207 ISOL Valves to Common Injection HDR", Rev. 5 WEC isometric drawing APP-PXS-PLW-01V, "Passive Core Cooling System Containment Building Room 11206 Core Makeup Tank Discharge Piping", Rev. 3 ASME Section III, Subsection NB, "Class 1 Components", 1998 Edition including 2000 Addenda MISTRAS 521-RT-302, "Radiographic Examination using Computed Radiography in Accordance with ASME Section V, Article 2", Revision 0 Section 1A35 Drawings and Procedures:

Drawing APP-PXS-PLW-01K, "Passive Core Cooling System Containment Bldg. Room 11206 CMT-A Discharge Piping," Revision 3 Drawing SV4-PXS-PLK-870305, "Material Identification for SV4-PXS-PLW-01K," Revision 0 Engineering & Design Coordination Report No. APP-PXS-GEF-850244, "PXS ISO Conditioning," Revision 0 MISTRAS 100-QC-005.2, "Qualification and Certification of Nondestructive Test Personnel,"

Revision 4.1 MISTRAS Procedure 100-PT-301, "Liquid Penetrant Examination in Accordance with ASME Section V, Article 6," Revision 12 WECTEC Quality Inspection Plan, IP No. F-S562-005, "Piping-Weld Joint Inspection ASME Section III Code Classes 1, 2 & 3," Revision 06.00 Weld Material Requisition Sheet 420755 Weld Procedure WPS1-8.8T01, "Manual and Machine GTAW of P-No. 8 to P-No. 8, ASME III All Subsections & Non-ASME III," Revision 10 Welding & NDE Records:

MISTRAS Certification Record No. 20159 for Level II Liquid Penetrant-Solvent Removable process certified on January 26, 2017, due January 13, 2020 MISTRAS Nondestructive Examination Report No. V-18-PT-301-2884 for liquid penetrant examination of pipe to valve butt weld # SV4-PXS-PLW-01K-1 on Check Valve PXS-PL-V017A, dated August 15, 2018 S&W Record of Welder Performance Qualification Test ASME Section IX Groove Welds for welders: TDM5366, and JCR9662 Weld Data Sheet for Work Package No. SV4-PXS-P0W-851001 for Weld No. SV4-PXS-PLW-01K-1 Material Certification Records:

CMTR 4931885 dated February 16, 2017 for weld wire 3/32" x 36" ER316L, ASME SFA 5.9, Heat/Lot No. 1030C CMTR 4974203 dated February 16, 2017 for weld wire 1/8" x 36" ER316L, ASME SFA 5.9 Heat/Lot No. 1030D Magnaflux Certification for Spotcheck Cleaner, SKC-S, Batch No. 17H01K, dated August 8, 2017

33 Magnaflux Certification for Spotcheck Developer, SKD-S2, Batch No. 14K01K, dated October 10, 2014 Magnaflux Certification for Spotcheck Penetrant, SKL-SP2, Lot No. 14C08K M&TE Records:

MISTRAS Flashlight Verification Log for White Maglite Model No. LED PRO, Serial No.

PG002769558, performed on August 14, 2018 using White Light Meter Serial No. 110703174 WECTEC Calibration Checklist No. V-AE-0101-2 for Oxygen Analyzer, calibrated on May 9, 2018 due May 9, 2019 WECTEC Calibration Checklist No. V-AP-0177-4 Digital Thermometer, calibrated January 20, 2018 Certificate of Calibration No. 2334966 dated May 11, 2018, for Magnaflux White Light Meter Serial No. 110703174, calibrated on May 11, 2018 due November 11, 2018 Section 1A36 Drawings and Procedures Drawing APP-PXS-PLW-014, "Passive Core Cooling System Containment Building Room 11206 Accumulator Discharge to DVIA," Revision 4 Engineering & Design Coordination Report No. APP-GW-GEF-454, "Administrative Closure of Piping Isometric Open Items," Revision 0 Weld Procedure WPS1-8.8T01, "Manual and Machine GTAW of P-No. 8 to P-No. 8, ASME III All Subsections & Non-ASME III," Revision 10 Procedure Qualification Record (PQR) PQ574, "Manual GTAW of P-NO. 8 A/SA-240 TP 304/304L Material to P-NO. 8 A/SA-240 TP 304/304L Material with ER308/308L, As-Welded,"

Revision 1 PQR 595, "Manual GTAW OF P-NO. 8 A/SA-240 TP 304/304H Material to P-NO. 8 A/SA-240 TP 304/304H Material, As-Welded, With ER308L," Revision 0 MISTRAS 100-QC-005.2, "Qualification and Certification of Nondestructive Test Personnel,"

Revision 4.1 MISTRAS Procedure 100-PT-301, "Liquid Penetrant Examination in Accordance with ASME Section V, Article 6," Revision 12 Welding & NDE Records Weld Data Sheet for Work Package Number SV4-PXS-P0W-800059 for Field Weld No. SV4-PXS-PLW-014-06 Weld Data Sheet for Work Package Number SV4-PXS-P0W-800059 for Field Weld No. SV4-PXS-PLW-014-10 MISTRAS Nondestructive Examination Report No. V-18-PT-301-2406 for liquid penetrant examination of butt weld of valve to pipe weld No. SV4-PXS-PLW-014-6 dated June 28, 2018 MISTRAS Nondestructive Examination Report No. V-18-PT-301-2414 for liquid penetrant examination of butt weld of valve to pipe weld No. SV4-PXS-PLW-014-10 dated June 28, 2018 Material Certification Records Certificate of Material Test Report No. 4931885 dated February 16, 2017 for ES-ZBES 3/32" x 18" length Lincoln ER316/316L weld wire ASME SFA 5.9 Lot No. 1030C Certificate of Material Test Report No. 7341122 dated August 31, 2015 for ES-ZBES 1/8" x 18" length Lincoln ER316/316L weld wire ASME SFA 5.9 Lot No. 1243V Certificate of Material Test Report No. 6338965 dated April 10, 2015 for ES-RAXM 1/8" x 18" length Lincoln ER308/308L weld wire ASME SFA 5.9 Lot No. 1203E

34 Certificate of Material Test Report No. 6338965 dated April 14, 2015 for ES-RAXL 3/32" x 18" length Lincoln ER308/308L weld wire ASME SFA 5.9 Lot No. 1203F Magnaflux Certification for Spotcheck Penetrant, SKL-SP2, Lot No. 14C08K, dated April 4, 2014 Magnaflux Certification for Spotcheck Developer, SKD-S2, Batch No. 17H08K, dated August 16, 2017 Magnaflux Certification for Spotcheck Cleaner, SKC-S, Batch No. 18A23K, dated February 6, 2018 M&TE Records MISTRAS Flashlight Verification Log for White Maglite Model No. LED PRO, Serial No. FL-19, performed on July 13, 2018 using White Light Meter Serial No. 110703066 ATS Certificate of Calibration No. 2288442 dated February 2, 2018 for Magnaflux White Light Meter Serial No. 110703066, calibrated on February 1, 2018 due on August 1, 2018 Qualification Records MISTRAS NDT Certification Record 21433 Level II Computed Radiography certified on August 1, 2017 due July 12, 2020 MISTRAS NDT Certification Record 20584 Level II Liquid Penetrant -Solvent Removable certified on March 24, 2017 due March 21, 2020 MISTRAS Visual Acuity Record dated November 17, 2017 due November 17, 2018 S&W Record of Welder Performance Qualification Test-ASME Section IX Groove Weld for three welders Section 1A37 Design Specification SV4-MT02-Z0-101, "Design Specification for AP1000 Accumulator Tank for PXS," Revision 2 Rigging Plan SV4-MT02-MHH-003, "Installation of Unit 4 Accumulator Tanks (MT-01A / MT-01B)"

Technical Manual SV4-MT02-VHM-001, "AP1000 Accumulator Tank Technical Manual:

Instruction for Receipt Inspection, Storage, and Assembly," Revision 0 Technical Manual SV4-MT02-VNM-001, "AP1000 Accumulator Tank Technical Manual:

Instruction for Operation and Maintenance," Revision 0 Section 1A38 Design Specification, Drawings and Purchase Order WEC Design Specification APP-PV03-Z0-001, "Design Specification for 3-inch and larger Manually Operated Gate, Stop Check and Check Valves, ASME Boiler & Pressure Code Section III, Class 2 and 3, for Various Systems" Revision 9 WEC Data Sheet APP-PV03-Z0D-186, "PV03 Data Sheet 186," Revision 4, Enertech Design and Seismic Analysis Report MA23182, "Design and Seismic Analysis Report for 8-inch ANSI 1707 TYPE ERV-Z Nozzle Check Valve," Revision F, dated August 29, 2017 Enertech MAA23182, "As-Built Design Report Addenda for Design Report MA23182 Revision F," Revision H, Enertech Drawing MD23164, "Nozzle Check Valve 8-inch Class 1707, ERV-Z, N.O With Position Indicator," Revision D Enertech Drawing MC24479, "Reducer, 8-1707, ERV-Z," Revision D WEC Purchase Order 4500328840 dated December 30, 2008 with Change Notice 23, issued to Curtiss-Wright Nuclear Division Brea Operation for procurement of 8-inch check valve serial number 11907

35 Quality Assurance Documents WEC Quality Release & Certificate of Conformance No. QR-18-905, Revision 0, dated June 28, 2018, for AP1000 Document No. SV4-PV03-VQQ-049 Enertech Quality Inspection and Test Plan No. 960033-QP-3, "8-inch Nozzle check valves Class 1500 INT Butt Weld Ends, Quantity 8," Revision 3, dated April 8, 2011 Enertech Quality Inspection and Test Plan No. 390269-3-QP, "Reducer Weldment Valve 8-inch Class 1707 BW Ends Schedule 160 PV03 Nozzle Check valve S/N 11907 with Reducer S/N 85064," Revision 1, dated April 17, 2018 Enertech Certificate of Compliance for June 26, 2018, for Reducer weldment of Nozzle Check valve, S/N 11907, Reducer S/N 85064 Enertech Equipment Qualification Certificate of Conformance dated June 26, 2018 ASME Form NPV-1, "Certificate Holders' Data Report for Nuclear Pumps or Valves," for 8" x 8 "

Check Valve," June 25, 2018 ASME Form N-2, "Certificate Holder's Data Report for Identical Nuclear Parts and Appurtenances," for Reducer S/N 85064 Heat Code PUH, certified date June 13, 2018 Material Records CMTR for 0.035" spool of ARCOS ER316/316L Heat No. E140778, Lot No. XF0140, dated December 4, 2015 CMTR for 1/16" AWS A5.13, ERCoCr-A Cobalt-6 weld wire Heat No. 08-1817. Heat Code NBC, dated June 11, 2011 CMTR for 1/16" x 36" ER316/316L ASME SFA 5.9, weld wire Heat No. 740574, Lot No.

AT9349, dated September 28, 2017 CMTR for 1/16" x 36" filler metal ER316/316L ASME SFA 5.9 No. 735354, Lot No. AT8700, dated March 16, 2009 CMTR for 3/32 x 36" Arcos ER316/316L ASME SFA 5.9, weld wire Heat No. 741358, Lot No.

CT9460, dated June 23, 2011 CMTR for 3/32" x 36" AWS A5.21, ERCoCr-A weld wire Heat No. 10-10930, Heat Code NBE, dated January 4, 2011 CMTR for pipe fittings P/N E0246D, S/Ns 53334-1 through 53334-8, Heat #11482, Heat Code NHU, dated February 7, 2014 CMTR for Reducer 8-1500 ERV-Z, P/N D7985N S/N 85064 Heat Code PUH, dated June 12, 2018 CMTR for valve body P/N D7982D S/Ns 4011 through 40118 E2203, Heat # 2H246, Heat Code NHV, dated February 7, 2014 CMTR for valve disk P/N D7983D S/Ns 53018 through 53025, Heat # 50869, Heat Code NMC, dated December 3, 2013 Energy & Process CMTR for 2" round bar for weld sleeve P/N E1333D, Heat No. 425031 dated March 6, 2013 Me-L-Chek Batch Certification for Cleaner E-59A, Batch No. 6900D13, dated April 30, 2013 Met-L-Chek Batch Certification for Developer D-70, Batch No. 6891D13, dated April 26, 2013 Met-L-Chek Batch Certification for Visible Penetrant VP-30, Batch No. 6607K11, dated October 12, 2011 NDE and Hydrostatic Test Records Test Report (hydrostatic shell test, seat leakage, operability (manual) and operability (push rod) and jet test) on original 8-inch DRV-Z Nozzle Check valve assembly P/N D8753N, S/N 11907 dated January 31, 2014 Test Report (hydrostatic shell test) for Reducer 8-inch 1707 ERV-Z P/N D7985N S/N 85064, dated June 12, 2018

36 Test Report (hydrostatic shell test, seat leakage, operability (manual) and operability (push rod) and jet test) for Post Weldment of 8-inch DRV-Z Nozzle Check valve assembly P/N D8753N, S/N 11907 dated June 21, 2018 Visual Examination Test Report performed of weld repair weld lip of Reducer P/N D7985N S/N 85064, dated May 30, 2018 NDE Liquid Penetrant Examination Report of Reducer P/N D7985N S/N 85064 100%; dated June 12, 2018 NDE Liquid Penetrant Examination Report of Disc S/Ns 53018 through 53025, dated September 10, 2013 NDE Liquid Penetrant Examination Report of pipe fitting P/N E0264D, S/Ns 53334-1 through 53334-8, dated June 17, 2013 NDE Liquid Penetrant Examination Report of weld sleeve P/N D8965D, Heat No. 53484, Heat Code OAW, dated April 15, 2013 NDE Liquid Penetrant Examination Report of Completed weld joint S/N 58110, Valve Assembly S/N 11907, dated September 10, 2013 NDE Liquid Penetrant Examination Report of Butt Weld End Preparation on Reducer Weldment Valve Assembly S/N 11907, dated May 2, 2018 NDE Liquid Penetrant Examination Report of 100% LP of inner surfaces of Body S/N 40115, dated May 21, 2018 NDE Liquid Penetrant Examination Report of root pass on Reducer to Valve Assembly S/N 11907, dated June 14, 2018 NDE Liquid Penetrant Examination Report of LP inspection of all accessible surface on the outer fitting and cap assembly for Connector Male on 8-inch Valve Assembly S/N 11907, dated February 8, 2017 ELEMENT Radiograph Examination Report 37663 of Reducer Weldment to Valve Assembly S/N 11907, dated June 19, 2018 Dimensional Inspection Reports Dimensional Inspection Report for Reducer P/N D7985N, S/N 85064, dated June 12, 2018 Visual Examination Test Report for Welding of Pipe Fitting to Body P/N D8753N S/N 11907 Lot No. 58110, dated September 10, 2013 Visual Examination Test Report for Welding of Disc Overlay P/N D7983D, S/N 53018, dated April 22, 2013 Nozzle Check Wall Thickness Report for Body P/N D7982D, S/N 40115, dated November 15, 2012 Nozzle Check Wall Thickness Report for Reducer P/N D7985N, S/N 85064 Heat Code PUH dated May 3, 2018 Dimensional Inspection Report for Body, Disc, Diffuser, and Spring for Valve S/N 11907, dated January 30, 2014 Inspection Record Sheet for Weldment Assembly P/N E6574N S/N 11907, dated June 25, 2018 Weld Records Weld Repair Report for Reducer Item No. D7985N, S/N 85064, Heat Code PUH repaired on nonconformance material report 10838, dated May 30, 2018 Welding and Hardfacing Record dated June 14, 2018 Deviation Notices WEC DN APP-PV03-GNR-020, "Deviation Notice for Weld End "C" Bore for PV03 Data Sheet 186, Enertech DN 6," Revision 0 WEC DN APP-PV03-GNR-013, "Deviation Notice for PV03-Z0D-186 Butt Weld End dimensions," Revision 0

37 WEC DN APP-PV03-GNR-026, "Deviation Notice for PV03 for Liquid Penetrant Testing for Data Sheet 186, Enertech DN 7," Revision 0 Section 1A39 Drawings and Procedures Isometric Construction Drawing No. APP-PXS-PLW-02L, Passive Core Cooling System Containment Bldg. Room 11207, From Containment Recirc. To DVI-B, Revision 3 Construction Drawing SV4-PXS-PHK-875294, Weld Map for Support SV4-PXS-PH-11R0142, Revision 0 WECTEC Inspection Plan F-S562-008, "Supports-Welding Inspection ASME Section III Code-Subsection NF (Classes 1, 2 & 3)", Revision 04.00, June 21, 2018 Stone & Webster Welding Procedure Specification WPS1-1.1GTSM-NF-2, Revision 5, January 30, 2018 MISTRAS procedure 100-QC-005.2, "Qualification and Certification of Nondestructive Test Personnel," Revision 4.1 MISTRAS procedure 100-MT-301, Magnetic Particle Examination In Accordance with ASME Section V, Article 7, Revision 2, November 28, 2011 CB&I Inspection Plan F-S562-006, "Pipe Welding/Brazing ASME B31.3, Power Piping-Visual Weld Inspection (Condenser, Internal Pipe Welds)," Revision 2, Change 0, August 17, 2015 Weld and NDE Records Weld Data Sheet for field weld SV4-PXS-PH-11R0142-7, in work package SV4-PXS-PHW-800004 Weld Material Requisition No. 421530 for weld SX4-PXS-PH-11RO142-1, 2, 4, 7, 8, using E7018 electrodes of 3/32-inch diameter, Lot-No. 1351X, August 22, 2018 MISTRAS NDE Report - Magnetic Particle Examination Report No. V-18-MT-301-4224, August 27, 2018, of Weld SV4-PXS-PH-11R0142 Material Test Records Lincoln Certificate of Conformance and Certified Material Test Report No. 8105586 for 3/32 x 14-inch E7018 weld electrodes of SFA-5.1, Lot-No. 1351X, November 22, 2017 Lincoln Certificate of Conformance and Certified Material Test Report No. 8527218 for 1/8 x 14-inch E7018 weld electrodes of SFA-5.1, Lot-No. 1231G, September 13, 2016 Magnaflux Certificate of Certification for 8A Red Powder Batch No. 14J108, September 26, 2014 Measuring and Test Equipment Records ATS Certificate of Calibration No. 2334906, dated July 17, 2018, for Mistras Group Magnaflux White Light Meter Serial No. 110703174 calibration due November 11, 2019 WECTEC Calibration Checklist No. V-AP-0203-3, dated July 24, 2018, for Fluke digital thermometer S/N V-AP-0203 calibrated on July 24, 2018 WECTEC Calibration Checklist No. V-M-0030-4, dated March 15, 2018, for digital light meter S/N V-M-0030 calibrated on March 15, 2018 MISTRAS Infrared Thermometer Verification Report dated July 18, 2018, for IR S/N E4092014490, Model No.22-171, calibrated on July 18, 2018 due January 18, 2019 MISTRAS Flashlight Verification Form for Model Q5 Serial No. FL-01, verified using Light Meter Serial No. 110703066 on September 29, 2017

38 Qualification Records Stone & Webster Record of Welder Performance Qualification Test ASME Section IX Groove Weld Record Test No. 1CS-03 for GTAW/SMAW, 6G position for P1-P1 material, June 4, 2018 MISTRAS NDT Certification Record No. 20271 for Level II Magnetic Particle Yoke Technique certified on February 17, 2017 due February 7, 2020 MISTRAS Visual Acuity Record for Level II MT inspector to Jaeger Number 1 method, August 8, 2018 Section 1A40 Drawings SV4-1230-CCK-840392, "Unit 4 Auxiliary Building Walls Placements from El. 100'-0" to El. 117'-

6", Revision 0 SV4-1230-CC-919, "Auxiliary Building Concrete Outline Area 1 El. 100'-0" Sections I & J,"

Revision 4 SV4-1200-CR-914, "Auxiliary Building Area 1 Concrete Reinforcement Walls P & Q Elevations,"

Revision 8 Engineering and Design Coordination Reports (E&DCRs)

APP-1240-GEF-850059, "Concrete Hold at El. 117'-6" to 135'-3" on Wall L Due to CAP IR-2018-8808," Revision 0 Nonconformance and Disposition Reports (N&Ds)

SV4-CR01-GNR-000402, "Missing U-Bands on M-Line," Revision 0 SV4-CR01-GNR-00334, "Rebar and Conduit Interference," Revision 0 SV4-CR01-GNR-00319, "Wall 53 Rebar Failed Minimum Concrete Cover," Revision 0 Section 1A41 Drawings:

SV4-0000-C9-001, "AP1000 Concrete General Notes," Revision 7 SV4-0000-C9-002, "AP1000 Concrete General Notes," Revision 8 SV4-0000-C9-002A, "AP1000 Concrete General Notes," Revision 2 SV4-1200-CR-991, "Auxiliary Building Concrete Reinforcement Typical Opening Detail,"

Revision 4 SV4-1200-CR-992, "Auxiliary Building Concrete Reinforcement Typical Opening Detail (Sheet 2)," Revision 6 SV4-1200-CR-910, "Auxiliary Building Areas 1 & 2 Concrete Reinforcement Wall 11 Elevation,"

Revision 7 SV4-1230-CR-910, "Auxiliary Building Areas 1 & 2 Concrete Reinforcement Wall 11 - Sections

& Details El 100'-0" El 109'-0" & El 117'-6"," Revision 8 APP-1200-CE-994, "Auxiliary Building Non-Standard Embedment Plates NSP-11, 1P-12a, NSP-14, NSP-16, NSP-17, NSP-18, NSP-19 & NSP-20," Revision 3 SV4-1231-CE-917, "Auxiliary Building Area 1 Embedments Wall 11 Elevation 100-0 South View," Revision 7 SV4-1231-CEX-917, "Auxiliary Building Area 1 Wall 11 Embedments Index EL 100-0 South View Sheet 1," Revision 6 SV4-CE01-CE-001, "Standard Embedment Plates Headed Anchor (HA) Type (Sheet 1),"

Revision 6

39 Procedures and Specifications:

APP-GW-GAP-420, "Engineering and Design Coordination Reports," Revision 14 APP-GW-GAP-428, "Nonconformance and Disposition Report," Revision 15 SV4-CC01-Z0-026, "Safety Related Mixing and Delivering Concrete," Revision 7 SV4-CC01-Z0-027, "Safety Related Concrete Testing Services," Revision 6 SV4-CC01-Z0-031, "Safety Related Placing Concrete and Reinforcing Steel," Revision 8 SV4-CR01-Z0-011, "Furnishing of Safety Related Steel," Revision 4 Work Packages:

Work Package SV4-1230-CRW-800030, Revision 0 Work Package SV4-1230-CRW-800032, Revision 0 Work Package SV4-1230-CCW-800030, Revision 0 Work Package SV4-1230-CCW-800032, Revision 0 Engineering and Design Coordination Reports:

APP-1240-GEF-850060, "Wall 11 Constructability Changes," Revision 0 APP-CR01-GEF-850465, "EL 100' 11 and I-Wall CJ Changes," Revision 0 SV3-CC01-GEF-000021, "Eliminate CJ in Col. Line 11 Wall," Revision 0 APP-CE01-GEF-850173, "UNC Threads on Nelson Stud," Revision 0 Section 1A42 Design Specifications SV3-CC01-Z0-031, Safety Related Placing Concrete and Reinforcing Steel, Rev. 8 Design Drawings SV4-1230-CC-913, Auxiliary Building Concrete Areas 1 & 2 EL. 100'-0" Sections G & H, Rev. 7 SV4-1240-CC-913, Auxiliary Building Concrete Outline Areas 1 & 2 EL. 117'-0" Sections G & H, Rev. 5 SV4-1200-CR-913, Auxiliary Building Areas 1 & 2 Concrete Reinforcement Walls L & M Elevations, Rev. 9 SV4-1230-CC-913, Auxiliary Building Areas 1 & 2 Concrete Reinforcement Walls L & M Sections and Details EL. 100'-0", Rev. 8 SV3-0000-C9-002A, AP1000 Concrete General Notes, Rev. 2 Nonconformance & Disposition Reports SV4-CR01-GNR-000400, NI4 Additional Bars SP-17, Rev.0 SV4-CR01-GNR-000335, Clear Cover on L and M Line Headers, Rev. 0 Engineering & Design Coordination Reports APP-CR01-GEF-850496, Wall L EL. 117'-6" Header, Rev. 0 SV0-CR01-GEF-000397, Aux. Bldg. Bars Developing in Shield Building Wall, Rev.0 Procedures APP-GW-GAP-420, Engineering and Design Coordination Reports, Rev. 12 APP-GW-GAP-428, Nonconformance and Disposition Report (N&D), Rev. 15 Section 1A43 Design Specifications SV4-CC01-Z0-031, "Safety Related Placing Concrete and Reinforcing Steel," Rev. 8 SV4-CC01-Z0-026, "Safety Related Mixing and Delivering Concrete," Rev. 7

40 SV4-CC01-Z0-027, "Safety Related Concrete Testing Services," Rev. 6 Drawings SV4-0000-C9-001, "AP1000 Concrete General Notes," Rev. 8 SV4-1200-CR-959, "Auxiliary building Area 6 Concrete Reinforcement Wall N Elevation," Rev. 8 SV4-1230-CR-959, "Auxiliary Building area 6 Concrete Reinforcement Wall N Sections and Details," Rev. 8 SV4-1236-CC-603, "Auxiliary Building Concrete Outline Area 6 Floor EL. 100'-0"," Rev. 4 Engineering & Design Coordination Reports SV0-CR01-GEF-001082,"Rebar Design Issues in Walls Around Room 12374", Rev. 0 SV0-CR01-GEF-001101,"Wall N Vertical Construction Joints Near Column Lines 1 and 2", Rev.

0 SV4-CC01-GEF-000065,"Altered Construction Joint Location in N-Line", Rev. 0 SV4-CR01-GEF-000342,"Additional Formsavers at N-Line", Rev. 0 Pour Card 4029, "Unit 4 CL N (Wall 90)", Date: 8/10/2018 Batch Tickets 76751, Date: 8/10/2018 76756, Date: 8/10/2018 76776, Date: 8/10/2018 Section 1P01 SNC CAR 211074, (NRC Identified) Clarification to Westinghouse on Boron Precipitation Concern CR 815684, generated on 3/24/2017 Westinghouse CAPAL 100025998, SNC ICAP CR 815684 Boron Precipitation RFI response lacks adequate technical detail, submitted on 6/23/2014 SNC CR 771303, (NRC Identified) Boron precipitation analysis during ES-1.3, entered on 2/10/2014 SNC CR 778445, Boron precipitation analysis does not take into account operator action during ES-1.3, entered on 2/24/2014 SNC CR 794478, Consortium Input Needed for NRC Question, entered on 3/31/2014 SNC CR 815684, Boron Precipitation RFI response lacks adequate technical detail, entered on 5/20/2014 SNC CR 835207, (NRC Identified) Clarification to Westinghouse on Boron Precipitation Concern CR 815684, entered on 7/02/2014 SNC TE 771978, Action to perform: Engineering to validate adequate core flow exists to prevent Boron precipitation, entered on 2/11/2014 SNC TE 794935, Generate an RFI for WEC input into the boron precipitation analysis, entered on 4/01/2014 SNC TE 816058, Track Consortium response and resolution, entered on 5/21/2014 SNC TE 913919, Provide additional detail to WEC to obtain justification for ES-1.3, entered on 3/03/2015 APP-RNS-M3C-506, RELAP5 Evaluation of Boron Concentration Inside the Core During RNS Hold-Up of ADS-4 Actuation, Rev. 0, approved on 9/01/2016 3-EOP-ES-1.3, ADS Stage 1-3 Actuation Response, Version A=0.0, approved on 11/17/2014 ND-LI-VNP-002, Version 8, Applicability Determination and 50.59/Departure Screening for VEGP 3&4, effective date 5/30/2014

41 ND-LI-VNP-002-F01, Version 8, Applicability Determination for VEGP Units 3&4, for Activity/Document No.: 3-EOP-ES-1.3 and 3-EOP-ES-1.3-B, review completed on 9/19/2014 ND-LI-VNP-002-F06, Version 2, 50.59 / Departure Screening for Vogtle 3&4, for Activity/Document No.: 3-EOP-ES-1.3 and 3-EOP-ES-1.3-B, review completed on 9/19/2014 ND-AD-002, Nuclear Development Corrective Action Program, Rev. 26, effective date 4/20/2017 Section 1P02 ND-AD-002, Nuclear Development Program Corrective Action Program, Rev. 27.0 APP-GW-GAP-428, "Nonconformance and Disposition Report," Revision 15 APP-GW-GAP-420, "Engineering and Design Coordination Reports," Revision 14 Section 1P03 NEI 08-01, Industry Guideline for the ITAAC Closure Process Under 10CFR Part 52, Revision 5 Corrected Regulatory Guide 1.215, "Guidance for ITAAC Closure Under 10 CFR Part 52," dated 07/2015 Procedure ND-RA-001-008, ITAAC Principal Closure Document review and Development, Version 11 Review Form, ND-RA-001-008-F01, ITAAC Principal Closure Document, Version 9.0 Procedure ND-RA-001-006, Development and Approval of ITAAC Submittals (ICN, UIN, PCN),

Version 5.2 & 6 ND-DC-001, Records Management, Version 20 Procedure ND-RA-001-009, NRC Notifications Including Requirements for ITAAC Maintenance, Version 9.0 Procedure ND-RA-001-005, Screening, Evaluating, and Reporting Conditions Related to ITAAC, Version 7 ND-AD-002, Nuclear Development Corrective Action Program, Version 27.0 ICNs and PCD Review Forms for Unit 3 ITAACs 31, 34, 672, and 757 ICNs and PCD Review Forms for Unit 4 ITAACs 8, 31, 89, 335, and 426 Focused Area Self-Assessment (FASA) Plan and Report, Topic: ITAAC Lifecycle, Dated 10/10/17 FASA Plan and Report, Topic: ITAAC Program, Dated 8/24/2018 Check-In Self Assessment (CISA) Plan and Report, Topic: CAR 272225 Apparent Cause Determination - Effectiveness Review of CAPR, CA1 and CA2, Dated 3/29/18 TE 1004771, "CAPR: Revise Procedure ND-RA-001-006 to Denote CAPR Commitments," entry date 2/19/2018 CR 50005254, "ITAAC Principal Closure Document (PCD) Revision Control and Review Issues," reported date 9/19/2018 IR-2018-15991, Rev. 4, "WEC ITAAC Maintenance Evaluation not performed on revised vendor document," origination date 9/18/2018 IR-2018-15990, Rev. 4, "WEC ITAAC Maintenance Evaluation Forms for APP-OCS-GER-302 Revisions 1, 2, and 3 was not completely filled out as required by the process at the time of approval," origination date 9/18/2018 IR-2018-15988, Rev. 4, "WEC ITAAC Maintenance Evaluation Forms not completed before the loading of Primary Closure Document revision to SNC documentum system," origination date 9/18/2018 SM1-1100-GNR-100012, Rev. 0, "The coating issues nearby MY03 circulation screen in 1#NI Containment Building," dated 6/20/2017 HY1-1100-GNR-000029, Rev. 0, "Paint Issues Nearby PXS Circulation Filter of Containment Building in 1#NI," dated 6/12/2017

42 TE 1008527, "ITAAC Applicable Tracking TE for CR 10478501/CAR273314," entry date 4/04/2018 CAR 273314, "Condition identified in C/R 10414220 not fully addressed," entry date 3/20/2018 CRs 10414220, 10453326, 10461189, and 50001771 Section 1P04 Purchase Orders PO# WSV3B00044, "Blanket Order/Master Agreement: 132175-D500.06", Rev. 0 to ENERGY AND PROCESS CORP Issued by: WECTEC GLOBAL PROJECT SERVICES INC. Dated:

7/17/2017 PO# WSV3B00050, "Blanket Order/Master Agreement: 132175-D500.06", Rev. 0 to ENERGY AND PROCESS CORP Issued by: WECTEC GLOBAL PROJECT SERVICES INC. Dated:

8/1/2017 PO# WSV3B00095 Item 17-1, "Blanket Order #WSV 3SH2503 Rev. 0", Rev. 1 to DuBose National Energy Services, Inc. Issued by: WECTEC. Dated: 8/27/2018.

PO# WSV3ER0106, Rev. 1 to NOVA Machine Products Corp. issued by WECTEC Global Project Services, Inc. Dated: 1/22/2018 PO# WSV3B00075, Rev. 0 to NOVA Machine Products issued by WECTEC Global Project Services, Inc. Dated: 3/15/2018 PO# WSV3B00063, Rev. 0 to GERDAU, Inc. issued by WECTEC Global Project Services, Inc.

Dated: 1/23/2018 PO# WSV3SS0149, Rev. 0 to Mackson Nuclear, LLC issued by Georgia Power Company.

Dated: 10/12/2017 PO# WSV3D50058 (18041-SUB-003, Rev. 2) Commercial Grade Dedication Plan provided by Mackson Nuclear, LLC for Carolina Fabricators, Inc. Dated: 4/10/2018 Evaluations Chicago Bridge & Iron (CB&I) Initiation/Review/Evaluation Form (10CFR21 / 10CFR50.55 (e)

Evaluation ID: 15-0047 Vogtle Unit 3 / CAR No.: 2015-0560 Item: CA01-38 Tolerance Nonconformances. Dated 7/15/2015.

CB&I Initiation/Review/Evaluation Form (10CFR21 / 10CFR50.55 (e) Evaluation ID: 15-0090 Vogtle Unit 3 / CAR No.: 2015-1361, 2015-1399, 2015-2368, 2015-4015 Item: CA01-36 RCS Pipe Gouges and Grinder Marks. Dated 10/29/2015.

CB&I Initiation/Review/Evaluation Form (10CFR21 / 10CFR50.55 (e) Evaluation ID: 15-0196 Vogtle Unit 3 / CAR No.: N/A Item: Passive Core Cooling System (PXS) Pipe Supports Nonconformances. Dated 3/22/2016.

WECTEC - Initiation/Review/Evaluation Form (10CFR21 / 10CFR50.55 (e) Evaluation ID: 16-0080 Vogtle Unit 4 / CAR No.: 2016-1984, CAPAL No.: 100386517 Item: CA20 Submodule Unsatisfactory Embed Welds. Dated 8/31/2016 WECTEC - Initiation/Review/Evaluation Form (10CFR21 / 10CFR50.55 (e) Evaluation ID: 17-0001 Vogtle Units 3 & 4 / N&D No.: APP-PH01-GNR-850000 CAPAL No.: 100440646 Item:

Failure to perform testing to validate Post Weld Heat Treatment (PWHT). Dated 6/13/2017 Procedures APP-GW-GAP-428, Nonconformance and Disposition Report (N&D), Rev. 15, dated: 6/28/2018 ND-LI-001, 10 CFR Part 21 and 10 CFR 50.55 (e) Evaluating and Reporting of Defects and Noncompliance for Nuclear Development, Version 13.0, dated: 2/22/2016 ND-SC-VNP-001, Procurement of Materials and Services for Vogtle 3&4 Construction, Version 2.0, Dated: 7/2/2018

43 SVPP 05-02, Identifying and Reporting Defects and Failures to comply under 10 CFR 21 and 10 CFR 50.55 (e), Rev. 0, dated: 10/25/2017 ND-DC-001-017, Accelerated Team Vision (ATV) Records Management, Version 2.0, dated:

7/18/2018 QS 17.01, Quality Assurance Records System, Rev. 8, dated: 3/22/2018.

Drawings SV0-654-A0-800000, Vogtle Electric Generating Plant Engineering & Admin. Building 302 First and Second Floor Life Safety Plans / Code Review, Rev 3, dated: 2/1/2015.

Section 4OA5.01 Calculations APP-RCS-M3C-046, "AP1000 PRHR Inlet and ADS 4th Stage B - Thermal Stratification Analysis," Revision 5 Corrective Action Documents CAPAL 100478099, "ADS-4 Transient," 6/20/2017 CAPAL 100481984, "Squib Valve Transient Assumptions," 7/7/2017 CAR 270354, "IOC 17-027 - ASME Inspection URI; NRC Potential NCV - Thermal transient Analysis," 6/23/2017 CAR 270683, "NRC ASME Inspection Squib Valve Transient Undocumented Assumptions,"

7/20/2017 CR 10379762, "IOC 17-027 - ASME Inspection URI; NRC Potential NCV - Thermal transient Analysis," 6/22/2017 CR 10389193, "NRC ASME Inspection Squib Valve Transient Undocumented Assumptions,"

7/20/2017 Design Documents APP-PV70-VDR-101001, "Design Report for PV70 Datasheet 101," Revision 2 Engineering & Design Coordination Reports APP-PV70-GEF-088, "Squib Valve Transient Update," Revision 0 APP-PV70-GEF-092, "ADS-4 Squib Valve Thermal Transient Update," Revision 0 Transient Documents APP-PV70-Z0Y-001, "Plant and System Transients Applicable to PV70 Valves," Revision 3 APP-PV70-Z0Y-002, "Thermal Transients Applicable to ADS-4 Squib Valve," Revision 1 Section 4OA5.02 Corrective Action Documents CAPAL 100436977, "Performance deficiency CR 10308295 and CR 10308213, IOC 16-062/IOC 17-012 (CR 10336421)," 12/15/2016 CAR 268223, "Incomplete fusion present on the ends of baseplates for CA01 and CA02,"

12/13/2016 CAR 268236, "IOC 16-062, Performance deficiency, Potential More than Minor Violation,"

12/13/2016 CAR 268972, "IOC 16-062, Performance deficiency, Green Non Cited Violation," 2/27/2017 CR 10308295, "IOC 16-062, Performance deficiency, Potential More than Minor Violation,"

12/13/2016

44 CR 10308213, "Incomplete fusion present on the ends of baseplates for CA01 and CA02,"

12/13/2016 CR 10336421, "IOC 16-062, Performance deficiency, Green Non Cited Violation," 2/27/2017 Nonconformance & Disposition Reports (N&Ds)

SV3-CA01-GNR-000958, "CA01 B-Plates Welds / Supercede N&D SV3-CA01-GNR-000952,"

Revision 0 SV3-CA02-GNR-000069, "SV3-CA02 B-Plate Welds," Revision 0 SV4-CA01-GNR-000127, "SV4-CA01-03/04 B-Plates," Revision 0 SV4-CA05-GNR-000034, "SV4-CA05 B-PLATES," Revision 0 Nondestructive Examination (NDE) Reports V-17-MT-302-0246, Magnetic Particle Examination Report, 4/11/2017 V-17-MT-302-0650, Magnetic Particle Examination Report, 4/17/2017 V-17-PT-304-0246, Liquid Penetrant Examination Report, 4/28/2017 V-17-PT-304-0259, Liquid Penetrant Examination Report, 3/29/2017 V-17-PT-304-0262, Liquid Penetrant Examination Report, 3/29/2017 V-17-PT-304-0299, Liquid Penetrant Examination Report, 3/31/2017 V-17-PT-304-0301, Liquid Penetrant Examination Report, 6/19/2017 V-17-PT-304-0726, Liquid Penetrant Examination Report, 5/16/2017 V-17-PT-304-0788, Liquid Penetrant Examination Report, 5/22/2017 V-17-UT-311-0444, Ultrasonic Examination Report, 9/5/2018 V-17-UT-311-0788, Ultrasonic Examination Report, 5/23/2017 Procedures 100-PT-304, "Liquid Penetrant Examination in Accordance with the AWS Structural Welding Code," Revision 8 100-UT-311, "Ultrasonic Examination of Welds in Accordance with AWS Structural Welding Code D1.6," Revision 5 521-MT-302, "Magnetic Particle Examination of Welds in Accordance with the AWS Structural Welding Code," Revision 1 F-S561-004, "Structural Weld Inspection - Modules, and Fabrication and Submodule Assembly Tolerances," Revision 23 WCP-1, "Welding Control Procedure," Revision 10 Qualification Records CB&I Certification of Qualification Special Process, 1344833, 9/30/2014 CB&I Certification of Qualification Special Process, 1344833, 7/25/2016 CB&I Certification of Qualification Special Process, 1354334, 10/30/2014 CB&I Certification of Qualification Special Process, 1354334, 10/19/2016 CB&I Certification of Qualification Special Process, 1355423, 1/26/2014 CB&I Certification of Qualification Special Process, 1370643, 1/20/2016 CB&I Certification of Qualification Special Process, 1370643, 1/5/2017 Mistras NDT Certification Record, MT Level II, Certification No. 19639, 11/17/2016 Mistras NDT Certification Record, PT Level II, Certification No. 18791, 7/18/2016 Mistras NDT Certification Record, PT Level II, Certification No. 19736, 12/2/2016 Mistras NDT Certification Record, UT Level II, Certification No. 19303, 4/11/2017 Mistras Visual Acuity Record, 511749, 8/25/2016 Mistras Visual Acuity Record, 512873, 6/30/2016 Mistras Visual Acuity Record, 513125, 8/16/2016 Mistras Visual Acuity Record, 513317, 9/28/2016

45 Weld Records WECTEC Weld Data Sheets for weld CV8123-B-046-RW1 WECTEC Weld Data Sheets for weld CV8123-B-083-RW1 WECTEC Weld Data Sheets for weld CV8123-B-194-RW1 WECTEC Weld Data Sheets for weld CV8124-B-082-RW1 WECTEC Weld Data Sheets for weld CV8124-B-084-RW1 WECTEC Weld Data Sheets for weld CV8124-B-178-RW1 WECTEC Weld Data Sheets for weld CV8124-B-184-RW1 WECTEC Weld Data Sheets for weld CV8124-B-185-RW1 WECTEC Weld Data Sheets for weld CV8243-6-RW1 WECTEC Weld Data Sheets for weld CV8243-8-RW1 WECTEC Weld Data Sheets for weld CV8243-9-RW1 WECTEC Weld Data Sheets for weld CV8243-10-RW1 WECTEC Weld Data Sheets for weld CV8243-11-RW1 WECTEC Weld Data Sheets for weld CV8246-6-RW1 WECTEC Weld Data Sheets for weld CV8246-7-RW1 WECTEC Weld Data Sheets for weld CV8246-14-RW1 WECTEC Weld Data Sheets for weld CV8246-15-RW1 WECTEC Weld Data Sheets for weld CV8246-16-RW1 WECTEC Weld Data Sheets for weld CV8246-23-RW1 WECTEC Weld Data Sheets for weld CV10892-5-RW WECTEC Weld Data Sheets for weld CV10892-6-RW WECTEC Weld Data Sheets for weld CV10892-7-RW WECTEC Weld Data Sheets for weld CV10892-8-RW WECTEC Weld Data Sheets for weld CV10892-9-RW WECTEC Weld Data Sheets for weld CV10892-14-RW WECTEC Weld Data Sheets for weld CV10892-15-RW WECTEC Weld Data Sheets for weld CV10892-16-RW WECTEC Weld Data Sheets for weld 881476-11-RW-1 WECTEC Weld Data Sheets for weld 881476-12-RW-1 WECTEC Weld Data Sheets for weld 881476-13-RW-1 WECTEC Weld Data Sheets for weld 881476-14-RW-1 WECTEC Weld Data Sheets for weld 880191-15 WECTEC Weld Data Sheets for weld 880191-16 WECTEC Weld Data Sheets for weld 880191-17 WECTEC Weld Data Sheets for weld 880191-18 WECTEC Weld Data Sheets for weld 880191-19 WECTEC Weld Data Sheets for weld 880191-21

46 LIST OF ACRONYMS ACI American Concrete Institute ADS Automatic Depressurization System ANI Authorized Nuclear Inspector ASME American Society of Mechanical Engineers, 1998 Edition including 2000 Addenda ASTM American Society for Testing and Materials AWS American Welding Society BPVC Boiler and Pressure Vessel Code CAP Corrective Action Program CAPAL Corrective Action Prevention and Learnings CFR Code of Federal Regulations CMT Core Makeup Tank CMTR Certified Material Test Report CNS Containment System COL Combined License CR Condition Report DTI Direct Tension Indicator DVI Direct Vessel Injection E&DCR Engineering and Design Coordination Reports FCAW Flux-Cored Arc Welding FTT Fuel Transfer Tube GTAW Gas Tungsten Arc Welding HX Heat Exchanger ICN ITAAC Closure Notice IMC Inspection Manual Chapter IP Inspection Procedure IR Inspection Report IRWST In-Containment Refueling Water Storage Tank ITAAC Inspections, Tests, Analysis, and Inspection Criteria M&TE Measuring & Test Equipment MT Magnetic Particle Testing N&D Nonconformance and Disposition Report NCV Non-Cited Violation NDE Non-Destructive Examination No.

Number NQA Nuclear Quality Assurance NRC Nuclear Regulatory Commission PCD Principal Closure Document PCS Passive Containment Cooling System PNQAM Project Nuclear Quality Assurance Manual PNQCM Bechtel Project Nuclear QC Manual PQR Procedure Qualification Record

47 PRHR Passive Residual Heat Removal PRHR HX Passive Residual Heat Removal Heat Exchanger PT Liquid Penetrant Testing QC Quality Control RC Reinforced Concrete RCS Reactor Coolant System RT Radiographic Testing SC Steel Composite SGTIS Steam Generator Temporary Installation System SMAW Shielded Metal Arc Welding SNC Southern Nuclear Operating Company SSC Structure, System, and Component UFSAR Updated Final Safety Analysis Report UT Ultrasonic Testing VT Visual Testing WEC Westinghouse Electric Company WPS Welding Procedure Specification

48 ITAAC INSPECTED 13 2.1.02.02a 2.a) The components identified in Table 2.1.2-1 as ASME Code Section III are designed and constructed in accordance with ASME Code Section III requirements. 2.b)

The piping identified in Table 2.1.2-2 as ASME Code Section III is designed and constructed in accordance with ASME Code Section III requirements. 3.a)

Pressure boundary welds in components identified in Table 2.1.21 as ASME Code Section III meet ASME Code Section III requirements. 3.b)

Pressure boundary welds in piping identified in Table 2.1.2-2 as ASME Code Section III meet ASME Code Section III requirements. 4.a)

The components identified in Table 2.1.2-1 as ASME Code Section III retain their pressure boundary integrity at their design pressure.

4.b) The piping identified in Table 2.1.2-2 as ASME Code Section III retains its pressure boundary integrity at its design pressure.

5.b) Each of the lines identified in Table 2.1.2-2 for which functional capability Inspection will be conducted of the as-built components and piping as documented in the ASME design reports. Inspection of the as-built pressure boundary welds will be performed in accordance with the ASME Code Section III. A hydrostatic test will be performed on the components and piping required by the ASME Code Section III to be hydrostatically tested. Inspection will be performed for the existence of a report verifying that the as-built piping meets the requirements for functional capability.

Inspection will be performed for the existence of an LBB evaluation report or an evaluation report on the protection from dynamic effects of a pipe break. Section 3.3, Nuclear Island Buildings, contains the design descriptions and inspections, tests, analyses, and acceptance criteria for protection from the dynamic effects of pipe rupture.

The ASME Code Section III design reports exist for the as-built components and piping identified in Tables 2.1.21 and 2.1.22 as ASME Code Section III. A report exists and concludes that the ASME Code Section III requirements are met for non-destructive examination of pressure boundary welds. A report exists and concludes that the results of the hydrostatic test of the components and piping identified in Table 2.1.21 and Table 2.1.22 as ASME Code Section III conform with the requirements of the ASME Code Section III. A report exists and concludes that each of the as-built lines identified in Table 2.1.2-2 for which functional capability is required meets the requirements for functional capability.

An LBB evaluation report exists and concludes that the LBB acceptance criteria are met by the as-built RCS piping and piping materials, or a pipe break evaluation report exists and concludes that protection from the dynamic effects of

50 is required is designed to withstand combined normal and seismic design basis loads without a loss of its functional capability. 6. Each of the as-built lines identified in Table 2.1.2-2 as designed for LBB meets the LBB criteria, or an evaluation is performed of the protection from the dynamic effects of a rupture of the line.

a line break is provided.

72 2.1.03.03

3. The components identified in Table 2.1.3-1 as ASME Code Section III are designed and constructed in accordance with ASME Code Section III requirements. 4.

Pressure boundary welds in components identified in Table 2.1.3-1 as ASME Code Section III meet ASME Code Section III requirements. 5.

The pressure boundary components (RV, CRDMs, and incore instrument QuickLoc assemblies) identified in Table 2.1.3-1 as ASME Code Section III retain their pressure boundary integrity at their design pressure.

Inspection will be conducted of the as-built components as documented in the ASME design reports. Inspection of as-built pressure boundary welds will be performed in accordance with the ASME Code Section III. A hydrostatic test will be performed on the components of the RXS required by the ASME Code Section III to be hydrostatically tested.

The ASME Code Section III design reports exist for the as-built components identified in Table 2.1.3-1 as ASME Code Section III. A report exists and concludes that the ASME Code Section III requirements are met for non-destructive examination of pressure boundary welds. A report exists and concludes that the results of the hydrostatic test of the pressure boundary components (RV, CRDMs, and incore instrument QuickLoc assemblies) conform with the requirements of the ASME Code Section III.

51 90 2.2.01.01

1. The functional arrangement of the CNS and associated systems is as described in the Design Description of this Section 2.2.1.

Inspection of the as-built system will be performed.

The as-built CNS conforms with the functional arrangement as described in the Design Description of this Section 2.2.1.

52 91 2.2.01.02a 2.a) The components identified in Table 2.2.1-1 as ASME Code Section III are designed and constructed in accordance with ASME Code Section III requirements. 2.b)

The piping identified in Table 2.2.1-2 as ASME Code Section III is designed and constructed in accordance with ASME Code Section III requirements. 3.a)

Pressure boundary welds in components identified in Table 2.2.1-1 as ASME Code Section III meet ASME Code Section III requirements. 3.b)

Pressure boundary welds in piping identified in Table 2.2.1-2 as ASME Code Section III meet ASME Code Section III requirements. 4.a)

The components identified in Table 2.2.1-1 as ASME Code Section III retain their pressure boundary integrity at their design pressure.

4.b) The piping identified in Table 2.2.1-2 as ASME Code Section III retains its pressure boundary integrity at its design pressure.

Inspection will be conducted of the as-built components and piping as documented in the ASME design reports. Inspection of the as-built pressure boundary welds will be performed in accordance with the ASME Code Section III. i) A hydrostatic or pressure test will be performed on the components required by the ASME Code Section III to be tested. A hydrostatic or pressure test will be performed on the piping required by the ASME Code Section III to be pressure tested.

The ASME Code Section III design reports exist for the as-built components and piping identified in Table 2.2.1-1 and 2.2.1-2 as ASME Code Section III. A report exists and concludes that the ASME Code Section III requirements are met for nondestructive examination of pressure boundary welds. i) A report exists and concludes that the results of the pressure test of the components identified in Table 2.2.1-1 as ASME Code Section III conform with the requirements of the ASME Code Section III. A report exists and concludes that the results of the pressure test of the piping identified in Table 2.2.1-2 as ASME Code Section III conform with the requirements of the ASME Code Section III.

53 109 2.2.01.08

8. Containment electrical penetration assemblies are protected against currents that are greater than the continuous ratings.

An analysis for the as-built containment electrical penetration assemblies will be performed to demonstrate (1) that the maximum current of the circuits does not exceed the continuous rating of the containment electrical penetration assembly, or (2) that the circuits have redundant protection devices in series and that the redundant current protection devices are coordinated with the containment electrical penetration assemblys rated short circuit thermal capacity data and prevent current from exceeding the continuous current rating of the containment electrical penetration assembly.

Analysis exists for the as-built containment electrical penetration assemblies and concludes that the penetrations are protected against currents which are greater than their continuous ratings.

54 120 2.2.02.02a 2.a) The components identified in Table 2.2.2-1 as ASME Code Section III are designed and constructed in accordance with ASME Code Section III requirements. 2.b)

The pipelines identified in Table 2.2.2-2 as ASME Code Section III are designed and constructed in accordance with ASME Code Section III requirements. 3.a)

Pressure boundary welds in components identified in Table 2.2.2-1 as ASME Code Section III meet ASME Code Section III requirements. 3.b)

Pressure boundary welds in the pipelines identified in Table 2.2.2-2 as ASME Code Section III meet ASME Code Section III requirements. 4.a)

The components identified in Table 2.2.2-1 as ASME Code Section III retain their pressure boundary integrity at their design pressure.

4.b) The pipelines identified in Table 2.2.2-2 as ASME Code Section III retain their pressure boundary integrity at their design pressure.

5.b) Each of the pipelines identified in Table 2.2.2-2 for which functional Inspection will be conducted of the as-built components and piping as documented in the ASME design reports. Inspection of the as-built pressure boundary welds will be performed in accordance with the ASME Code Section III. A hydrostatic test will be performed on the components and piping required by the ASME Code Section III to be hydrostatically tested. Inspection will be performed for the existence of a report concluding that the as-built pipelines meet the requirements for functional capability.

The ASME Code Section III design reports exist for the as-built components and piping identified in Table 2.2.2-1 and 2.2.2-2 as ASME Code Section III. A report exists and concludes that the ASME Code Section III requirements are met for non-destructive examination of pressure boundary welds. A report exists and concludes that the results of the hydrostatic test of the components and piping identified in Table 2.2.2-1 and 2.2.2-2 as ASME Code Section III conform with the requirements of the ASME Code Section III. A report exists and concludes that each of the as-built pipelines identified in Table 2.2.2-2 for which functional capability is required meets the requirements for functional capability.

55 capability is required is designed to withstand combined normal and seismic design basis loads without a loss of its functional capability.

56 159 2.2.03.02a 2.a) The components identified in Table 2.2.3-1 as ASME Code Section III are designed and constructed in accordance with ASME Code Section III requirements. 2.b)

The piping identified in Table 2.2.3-2 as ASME Code Section III is designed and constructed in accordance with ASME Code Section III requirements. 3.a)

Pressure boundary welds in components identified in Table 2.2.3-1 as ASME Code Section III meet ASME Code Section III requirements. 3.b)

Pressure boundary welds in piping identified in Table 2.2.3-2 as ASME Code Section III meet ASME Code Section III requirements. 4.a)

The components identified in Table 2.2.3-1 as ASME Code Section III retain their pressure boundary integrity at their design pressure.

4.b) The piping identified in Table 2.2.3-2 as ASME Code Section III retains its pressure boundary integrity at its design pressure.

5.b) Each of the lines identified in Table 2.2.3-2 for which functional capability is required is Inspection will be conducted of the as-built components and piping as documented in the ASME design reports. Inspection of the as-built pressure boundary welds will be performed in accordance with the ASME Code Section III. A hydrostatic test will be performed on the components and piping required by the ASME Code Section III to be hydrostatically tested. Inspection will be performed for the existence of a report verifying that the as-built piping meets the requirements for functional capability.

Inspection will be performed for the existence of an LBB evaluation report or an evaluation report on the protection from dynamic effects of a pipe break. Section 3.3, Nuclear Island Buildings, contains the design descriptions and inspections, tests, analyses, and acceptance criteria for protection from the dynamic effects of pipe rupture.

The ASME Code Section III design reports exist for the asbuilt components and piping identified in Table 2.2.31 and 2.2.3-2 as ASME Code Section III. A report exists and concludes that the ASME Code Section III requirements are met for non-destructive examination of pressure boundary welds. A report exists and concludes that the results of the hydrostatic test of the components and piping identified in Table 2.2.31 and 2.2.3-2 as ASME Code Section III conform with the requirements of the ASME Code Section III. A report exists and concludes that each of the as-built lines identified in Table 2.2.3-2 for which functional capability is required meets the requirements for functional capability.

An LBB evaluation report exists and concludes that the LBB acceptance criteria are met by the as-built RCS piping and piping materials, or a pipe break evaluation report exists and concludes that protection from the dynamic effects of a line break is provided.

57 designed to withstand combined normal and seismic design basis loads without a loss of its functional capability. 6. Each of the as-built lines identified in Table 2.2.3-2 as designed for LBB meets the LBB criteria, or an evaluation is performed of the protection from the dynamic effects of a rupture of the line.

176 2.2.03.08b.02 8.b) The PXS provides core decay heat removal during design basis events.

2. Inspection of the elevation of the PRHR HX will be conducted.
2. The elevation of the centerline of the HXs upper channel head is greater than the HL centerline by at least 26.3 ft.

186 2.2.03.08c.iv.04 8.c) The PXS provides RCS makeup, boration, and safety injection during design basis events.

iv) Inspections of the elevation of the following pipe lines will be conducted: 4.

PRHR HX outlet line to SG connection iv) The maximum elevation of the top inside surface of these lines is less than the elevation of: 4. PRHR HX lower channel head top inside surface 187 2.2.03.08c.v.01 8.c) The PXS provides RCS makeup, boration, and safety injection during design basis events.

v) Inspections of the elevation of the following tanks will be conducted: 1.

CMTs v) The elevation of the bottom inside tank surface is higher than the direct vessel injection nozzle centerline by the following: 1. CMTs 7.5 ft

58 597 2.6.03.02.i

2. The seismic Category I equipment identified in Table 2.6.31 can withstand seismic design basis loads without loss of safety function.

i) Inspection will be performed to verify that the seismic Category I equipment identified in Table 2.6.31 is located on the Nuclear Island. ii)

Type tests, analyses, or a combination of type tests and analyses of seismic Category I equipment will be performed. iii)

Inspection will be performed for the existence of a report verifying that the as-built equipment including anchorage is seismically bounded by the tested or analyzed conditions.

i) The seismic Category I equipment identified in Table 2.6.31 is located on the Nuclear Island. ii)

A report exists and concludes that the seismic Category I equipment can withstand seismic design basis loads without loss of safety function. iii) A report exists and concludes that the as-built equipment including anchorage is seismically bounded by the tested or analyzed conditions.

760 3.3.00.02a.i.a 2.a) The nuclear island structures, including the critical sections listed in Table 3.3-7, are seismic Category I and are designed and constructed to withstand design basis loads as specified in the Design Description, without loss of structural integrity and the safety-related functions.

i) An inspection of the nuclear island structures will be performed.

Deviations from the design due to as-built conditions will be analyzed for the design basis loads.

i.a) A report exists which reconciles deviations during construction and concludes that the as-built containment internal structures, including the critical sections, conform to the approved design and will withstand the design basis loads specified in the Design Description without loss of structural integrity or the safety-related functions.

59 761 3.3.00.02a.i.b 2.a) The nuclear island structures, including the critical sections listed in Table 3.3-7, are seismic Category I and are designed and constructed to withstand design basis loads as specified in the Design Description, without loss of structural integrity and the safety-related functions.

i) An inspection of the nuclear island structures will be performed.

Deviations from the design due to as-built conditions will be analyzed for the design basis loads.

i.b) A report exists which reconciles deviations during construction and concludes that the as-built shield building structures, including the critical sections, conform to the approved design and will withstand the design basis loads specified in the Design Description without loss of structural integrity or the safety-related functions.

762 3.3.00.02a.i.c 2.a) The nuclear island structures, including the critical sections listed in Table 3.3-7, are seismic Category I and are designed and constructed to withstand design basis loads as specified in the Design Description, without loss of structural integrity and the safety-related functions.

i) An inspection of the nuclear island structures will be performed.

Deviations from the design due to as-built conditions will be analyzed for the design basis loads.

i.c) A report exists which reconciles deviations during construction and concludes that the as-built structures in the non-radiologically controlled area of the auxiliary building, including the critical sections, conform to the approved design and will withstand the design basis loads specified in the Design Description without loss of structural integrity or the safety-related functions.

60 763 3.3.00.02a.i.d 2.a) The nuclear island structures, including the critical sections listed in Table 3.3-7, are seismic Category I and are designed and constructed to withstand design basis loads as specified in the Design Description, without loss of structural integrity and the safety-related functions.

i) An inspection of the nuclear island structures will be performed.

Deviations from the design due to as-built conditions will be analyzed for the design basis loads.

i.d) A report exists which reconciles deviations during construction and concludes that the as-built structures in the radiologically controlled area of the auxiliary building, including the critical sections, conform to the approved design and will withstand the design basis loads specified in the Design Description without loss of structural integrity or the safety-related functions.

820 3.3.00.14

14. The external walls, doors, ceiling, and floors in the main control room, the central alarm station, and the secondary alarm station are bulletresistant to at least Underwriters Laboratory Ballistic Standard 752, level
4. 15. Deleted Type test, analysis, or a combination of type test and analysis will be performed for the external walls, doors, ceilings, and floors in the main control room, the central alarm station, and the secondary alarm station.

A report exists and concludes that the external walls, doors, ceilings, and floors in the main control room, the central alarm station, and the secondary alarm station are bulletresistant to at least Underwriters Laboratory Ballistic Standard 752, level 4.