ND-18-0298, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.04.01 (Index Number 556)

From kanterella
(Redirected from ML18059A162)
Jump to navigation Jump to search
Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.04.01 (Index Number 556)
ML18059A162
Person / Time
Site: Vogtle  
Issue date: 02/28/2018
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of New Reactors
References
ITAAC 2.5.04.01, ND-18-0298
Download: ML18059A162 (7)


Text

k Southern Nuclear FEB 2 8 201B Docket Nos.:

52-025 52-026 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Michael J. Yox Regulatory Affairs Director Vogtie 3 & 4 7825 River Road Waynestjoro, GA 30830 706-848-6459 tei 410-474-8587 ceii myox@southernco.com ND-18-0298 10CFR 52.99(c)(3)

Southern Nuclear Operating Company Vogtie Electric Generating Plant Unit 3 and Unit 4 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.5.04.01 [Index Number 556]

Ladies and Gentlemen:

Pursuant to 10 CFR 52.99(c)(3), Southern Nuclear Operating Company hereby notifies the NRC that as of February 28, 2018, Vogtie ElectricGenerating Plant (VEGP) Unit 3 and Unit 4 Uncompleted Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item2.5.04.01 [Index Number 556] has not been completed greater than 225-days priorto initial fuel load. The Enclosure describes the plan for completing this ITAAC. Southern Nuclear Operating Company will, at a later date, provide additional notifications for ITAAC that have not been completed 225-days prior to initial fuel load.

Southern Nuclear Operating Company (SNC) previouslysubmitted, via letter ND-16-2091

[ML16301A131], a Unit 3 Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load for Item 2.5.04.01 [Index Number556]. This resubmittal supersedes the previous Unit 3 notice in its entirety.

This notification is informed by the guidance described in NEI 08-01, IndustryGuideline for the ITAAC Closure Process Under 10 CFR Part 52, which was endorsed by the NRC in Regulatory Guide 1.215. In accordance with NEI 08-01, this notification includes ITAACfor which required inspections, tests, or analyses have not been performed or have been only partially completed. All ITAAC will be fully completed and allSection 52.99(c)(1) ITAAC Closure Notifications will be submitted to NRC to support the Commissionfinding that all acceptance criteriaare met priorto plant operation, as required by 10 CFR 52.103(g).

This letter contains no new NRC regulatory commitments.

U.S. Nuclear Regulatory Commission ND-18-0298 Page 2 of 4 If there are any questions, please contact Tom Petrak at 706-848-1575.

Respectfully submitted, Michael J. Yox RegulatoryAffairs Dfrector Vogtle 3 &4

Enclosure:

Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.5.04.01 [Index Number 556]

MJY/KJD/amw

U.S. Nuclear Regulatory Commission ND-18-0298 Page 3 of 4 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. D. A. Bost (w/o enclosures)

Mr. M. D. Rauckhorst (w/o enclosures)

Mr. M. D. Meier Mr. D. H. Jones (w/o enclosures)

Mr. D. L. McKinney Mr. M. J. Yox Mr. D. L. Fulton Mr. J. D. Williams Mr. F. H. Willis Ms. A. L. Pugh Mr. A. 8. Parton Mr. W. A. Sparkman Mr. 0. E. Morrow Ms. K. M. Stacy Mr. M. K. Washington Mr. J. P. Redd Ms. A. 0. Chamberlain Mr. D. R. Culver Mr. T. G. Petrak Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Reoulatorv Commission Mr. W. Jones (w/o enclosures)

Ms. J. M. Heisserer Mr. C. P. Patel Mr. M. E. Ernstes Mr. G. J. Khouri Mr. T. E. Chandler Ms. S. E. Temple Ms. P. Braxton Mr. N. D. Karlovich Mr. A. J. Lerch Mr. C. J. Even Mr. F. D. Brown Mr. B. J. Kemker Ms. A. E. Rivera-Varona Ms. L. A. Kent Mr. P. B. Donnelly Oalethorpe Power Corporation Mr. R. B. Brinkman Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson

U.S. Nuclear Regulatory Commission ND-18-0298 Page 4 of 4 Dalton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)

Mr. D. C. Durham (w/o enclosures)

Mr. M. M. Corletti Ms. L. G. Iller Mr. D. Hawkins Ms. J. Monahan Mr. J. L. Coward Ms. N. E. Deangelis Other Mr. J. E. Hesler, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., CDS Associates, inc.

Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Baich Bingham

U.S. Nuclear Regulatory Commission ND-18-0298 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-18-0298 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.5.04.01 [Index Number 556]

U.S. Nuclear Regulatory Commission ND-18-0298 Enclosure Page 2 of 3 ITAAC Statement Desion Commitment

1. The functional arrangement of the DOS is as described inthe Design Descriptionof this Section 2.5.4.

Insoections/Tests/Analvses Inspection of the as-built system will be performed.

Acceptance Criteria The as-built DDS conforms with the functional arrangement as described in the Design Description of this Section 2.5.4.

ITAAC Completion Description An inspection of the as-built Data Display and Processing System (DDS) is conducted after completion of construction to confirmthat the functional arrangement of the DDS is as described in the Design Descriptionof Combined License (COL) Appendix C, Section 2.5.4. This inspection encompasses the structures, systems, and components (SSCs) identified inthe COL Appendix C, Section 2.5.4, "Design Description".

The inspection (walkdown) is completed in accordance with APP-GW-ITY-004, Functional Arrangement ITAAC Guideline (Reference 1), which requires the preparation of a detailed inspection plan. This inspection plan includes the use of detailed drawings such as Pipingand Instrumentation Drawings (P&IDs) or Single Line Elementary Drawings to perform visual observations and compare the as-built system to the Design Description.

The inspection results are documented inthe Unit 3 and Unit 4 Principal Closure Documents XXX and YYY (References 2 and 3, respectively) supporting the Unit3 and Unit4 ITAAC 2.5.04.01 Completion Packages (References 4 and 5, respectively) and verifythat the SSCs are physically arranged and located to perform the functions described inthe Design Description. The inspection results confirm that the as-built DDS conforms with the functional arrangement as described in the COL Appendix C, Section 2.5.4, Design Description.

The Unit3 and Unit4 Principal Closure Documents XXX and YYY are available for NRC inspection as part of the Unit3 and Unit4 ITAAC 2.5.04.01 Completion Packages.

List of ITAAC Findings In accordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant ITAAC findings associated with this ITAAC.

U.S. Nuclear Regulatory Commission ND-18-0298 Enclosure Page 3 of 3 References ^available for NRG inspection) 1.

APP-GW-ITY-004, Functional Arrangement Guideline 2.

Principal Closure Document XXX (Unit3) 3.

Principal Closure Document YYY (Unit 4) 4.

ITAAC 2.5.04.01 Completion Package (Unit3) 5.

ITAAC 2.5.04.01 Completion Package (Unit4) 6.

NEI 08-01, "Industry Guideline forthe ITAAC Closure Process Under 10 CFR Part 52"